HomeMy WebLinkAboutS002 - GENERAL NOTESWF1 FOR WOOD CONNECTIONS NOT SPECIFICALLY NOTED OR DETAILED, FOLLOW THE REQUIREMENTS OF IBC 2012 TABLE 2304.9.1 OR ESR 1539. WF2 ALL NAILS ARE COMMON NAILS UNLESS NOTED OTHERWISE. ALL NAILS SHALL BE CAREFULLY DRIVEN AND NOT OVERDRIVEN. SUBMIT ALL PROPOSED FASTENERS FOR APPROVAL PRIOR TO CONSTRUCTION. INSALLATION OF ALL FASTENERS SHALL MEET THE REQUIREMENTS OF NDS AND ISANTA GUIDELINES, INCLUDING THOSE IN ESR 1539, AND SECTION 2303.6 OF IBC. WF3 REFER TO THE WALL SCHEDULES AND/OR FRAMING PLANS FOR SIZE, SPACING, AND SPECIES OF WALL STUDS. IF NOT SHOWN OTHERWISE, STUDS ARE TO BE #1 OR #2 SPRUCE-PINE-FIR (SPF) WITH STUD SPACING AT 16" O.C. MAXIMUM. IF NOT SHOWN OTHERWISE, BEARING WALL HEADERS ARE TO BE #2 SOUTHERN PINE (SP). SPRUCE-PINE-FIR (SOUTH) IS NOT SPRUCE- PINE-FIR AND MAY NOT BE USED. WF4 ALL WALL PLATES ARE TO BE ENGINEERED WOOD TO HELP CONTROL SHRINKAGE. ENGINEERED WOOD PLATES MUST BE LSL, PSL, OR LVL. IN ADDITION, ANY WOOD BLOCKING RUNNING HORIZONTALLY IN THE FLOOR SYSTEM SUCH AS BLOCKING BETWEEN THE ENDS OF TOP CHORD BEARING TRUSSES MUST BE ENGINEERED WOOD. ANY KNEE WALLS WITHIN THE FLOOR SYSTEM MUST HAVE ENGINEERED WOOD PLATES. WF5 TO CONTROL SHRINKAGE, FRAMING WILL BE DONE IN A MANNER THAT MINIMIZES HORIZONTAL WOOD. WHENEVER POSSIBLE, VERTICAL WOOD WILL BE USED AVOIDING THE STACKING OF HORIZONTAL BLOCKING. WF6 AT THE CONTRACTOR'S DISCRETION, STUDS IN NON-LOAD BEARING INTERIOR WALLS MAY BE SPACED AT 16" O.C. ON ALL LEVELS. WF7 FASTEN DOUBLE (DBL) STUDS TOGETHER WITH 0.131" x 3" NAILS AT 6" O.C. UNLESS NOTED OTHERWISE. FOR MORE THAN TWO STUDS, FASTEN IN THE SAME WAY, NAILING AS EACH STUD IS ADDED. WF8 SEE THE HEADER SCHEDULE FOR ALL HEADER SIZES AND MATERIALS. ALL HEADERS IN NON- LOAD BEARING INTERIOR WALLS ARE TO BE (2) 2x4 #2 SPF FOR OPENINGS UP TO 4'-0" AND (2) 2x6 #2 SPF FOR OPENINGS OVER 4'-0". ALL HEADERS IN NON-LOAD BEARING WALLS TO HAVE (1) JACK STUD AT EACH END. WF9 STUD SPACING AND HEADER TYPES ARE FOUND ON THE BEARING WALL AND HEADER FRAMING PLAN. WF10 REFER TO THE SHEAR WALL SCHEDULE FOR SHEATHING, NAILING, CTS HARDWARE REQUIREMENTS, ETC. REQUIRED FOR ALL SHEAR WALLS. WF11 USE DOUBLE TOP PLATES ON ALL WALLS, INCLUDING NON-LOAD BEARING WALLS, WITH ALL SPLICES AND CORNERS LAPPED. AT 'T' INTERSECTIONS DO NOT LAP TOP PLATE OF INTERSECTING WALL CUTTING THE TOP PLATE OF THE CONTINUOUS WALL, RATHER USE A METAL TIE PLATE AS DESCRIBED IN THE EXCEPTION TO SECTION 2308.9.2.1 OF THE IBC. WF12 UNLESS OTHERWISE NOTED ON PLAN OR DETAIL, ANCHOR WOOD WALL PLATES TO THE CONCRETE PODIUM SLAB USING HILTI X-U62 (0.157" DIA x 2 7/16" LONG) POWDER ACTUATED FASTENERS. SPACE PINS AT 24" O.C. FOR BOTH BEARING AND NON-LOAD BEARING WALLS. SEE SHEAR WALL TABLE FOR SPACING AT SHEAR WALLS. WF13 ON FRAMING PLANS, SPECIFIC INDIVIDUAL TRUSS LOCATIONS ARE ILLUSTRATIVE ONLY. IN ADDITION TO ARCHITECTURAL AND STRUCTURAL REQUIREMENTS, COORDINATE FINAL FLOOR AND ROOF FRAMING INCLUDING JOIST OR TRUSS LAYOUT AND TRUSS MEMBER CONFIGURATION WITH MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. OBTAIN ADDITIONAL MEP INFORMATION AS NEEDED FOR COMPLETE COORDINATION. KEEP ALL MECHANICAL CHASES FREE OF FRAMING. DO NOT LOCATE JOISTS OR TRUSSES AT PARALLEL PLUMBING WALLS. WF14 BEAR ALL FLOOR AND ROOF TRUSSES ON WOOD WALLS AND BEAMS OR WOOD PLATE ON STEEL BEAMS AS INDICATED. ALWAYS BEAR FLOOR AND ROOF JOISTS OR TRUSSES ON AVAILABLE INTERIOR AND EXTERIOR BEARING WALLS. DO NOT DO NOT CLEAR-SPAN FRAMING DISREGARDING AN AVAILABLE BEARING WALL WHERE SUCH A BEARING WALL IS IDENTIFIED. WF15 WHERE FLOOR TRUSSES ARE USED, USE A MINIMUM OF (2) 2x4 VERTICAL MEMBERS IN FLOOR TRUSSES AT ALL BEARINGS UNLESS NOTED OTHERWISE. ONE OF THESE VERTICALS MAY BE UNDER A RIBBON BOARD AT THE END OF THE TRUSS WHERE RIBBON BOARDS ARE ALLOWED. DO NOT ALLOW FOR, NOR USE RIBBON BOARDS AT THE END OF TRUSSES WHERE SOLID, CONTINUOUS FULL-HEIGHT BLOCKING OR CONTINUOUS WOOD-SHEATHED KNEE WALLS ARE INDICATED TO BE USED. WHERE RIBBON BOARDS ARE USED WITH FLOOR TRUSSES THEY ARE TO BE 2x6 MINIMUM. WF16 DESIGN ROOF JOISTS OR TRUSSES TO SUPPORT THE WEIGHT OF SNOW DRIFTING WHERE IT APPLIES, AS WELL AS ROOFTOP MECHANICAL UNITS, EXHAUST FANS, ACCESS HATCHES, ETC. CONFIRM WEIGHTS AND LOCATIONS BEFORE FINAL DESIGN AND SHOW THE LOADS FOR THESE UNITS/FIXTURES ON THE SEALED DRAWINGS. THE CONTRACTOR SHALL ENSURE THE UNITS ARE INSTALLED AT THEIR DESIGN LOCATIONS. WF17 WHERE FRAMING SUPPORTED BY A JOISTS OR TRUSS CAN CAUSE UPLIFT ON THAT JOIST OR TRUSS (SUCH AS AT CANTILEVERED BALCONY FRAMING) THE DESIGNER SHALL CONSIDER A LOAD CASE THAT MAXIMIZES THE UPLIFT LOAD IN COMBINATION WITH NO LIVE LOAD APPLIED TO THE JOIST OR TRUSS SUPPORTING THE UPLIFT. WF18 ALL EXPOSED FRAMING SHALL BE PRESSURE PRESERVATIVE TREATED WOOD (PPT) AS DESCRIBED IN THE SPECIFICATIONS. ALL PPT WOOD TO BE KILN DRIED AFTER TREATMENT (KDAT). HARDWARE USED WITH PPT WOOD TO BE HOT-DIP GALVANIZED OR STAINLESS STEEL. WF19 ALL HARDWARE TO BE SIMPSON STRONG-TIE OR APPROVED EQUAL. WHERE HARDWARE IS NOT SPECIFICALLY DESIGNATED, SUBMIT PROPOSED HARDWARE FOR APPROVAL. WHERE MORE THAN ONE TYPE OF FASTENER OR FASTENER PATTERN IS ALLOWED BY THE HARDWARE MANUFACTURER, HARDWARE FASTENERS ARE TO BE OF THE TYPE, SIZE, AND QUANTITY TO MAXIMIZE THE LOAD CAPACITY OF THE HARDWARE IN THE SPECIFIC APPLICATION SHOWN ON THESE PLANS, UNLESS NOTED OTHERWISE. WF20 WHERE A WOOD-FRAMED WALL BACKS UP A NON-STRUCTURAL MASONRY VENEER, TIES MUST BE FASTENED TO THE WOOD FRAMING MEMBERS USING SCREWS MEETING THE REQUIREMENTS OF THE TIE MANUFACTURER. WHERE THE TIE MANUFACTURER ALLOWS THE USE OF NAILS, RING SHANK NAILS MUST BE USED. SMOOTH SHANK NAILS MAY NEVER BE USED TO ATTACH MASONRY TIES TO WOOD FRAMING. WF21 REFERENCE THE ARCHITECTURAL PLANS FOR LAYOUT OF ALL WALLS, OPENINGS, WALL TYPES, ETC. VERIFY ALL DIMENSIONS PRIOR TO DESIGN OF WALL PANELS AND IMMEDIATELY NOTIFY THE ARCHITECT AND ENGINEER OF ANY DISCEPANCIES. WF22 WHERE A SPECIALTY STRUCTURAL ENGINEER (SSE) DESIGNS FLOOR AND/OR ROOF FRAMING, THE FLOOR AND/OR ROOF DESIGNER SHALL PROVIDE THE WALL PANEL DESIGNER THE LOADS/REACTIONS AND LOCATIONS OF ALL GIRDER OR BEAM BEARING POINTS. THE WALL PANEL DESIGNER SHALL SPECIFY AND THE WALL PANEL MANUFACTURER SHALL INSTALL SUFFICIENT COLUMNS/STUDS TO SUPPORT ALL SUCH LOADS FROM THE GIRDER OR BEAM BEARING LOCATION DOWN TO THE SUPPORTING FOUNDATION OR PODIUM FRAMING. THE CONTRACTOR SHALL ENSURE THE PRESENCE OF SUCH COLUMNS/STUDS. SIMILARLY, WHERE WALLS ARE FIELD-FRAMED, THE FRAMING CONTRACTOR SHALL INSTALL THE COLUMNS/STUDS FOR SUPPORT OF GIRDERS AND BEAMS. AS A MINIMUM, THE NUMBER OF STUDS SHOWN ON THE PLANS SHALL BE USED, WITH A MINIMUM OF (2) 2x6 OR (3) 2x4 STUDS. WF23 AT BEARING WALLS, BLOCKING MUST BE ADDED IN THE FLOOR SYSTEM TO CREATE CONTINUITY OF ALL WHEAR WALL CHORD STUDS, POSTS AND COLUMNS, JACK/KING STUDS AT HEADERS, ETC. SUCH BLOCKING SHALL BE PART OF THE SHEATHED SHEAR BLOCKING PANELS, OR KNEE WALLS WHERE THEY ARE USED. WHERE THERE ARE WOOD WALLS BELOW, THESE STUDS, COLUMNS, POSTS, ETC. MUST BE PRESENT IN THOSE WALLS AS WELL CREATING A CONTINUOUS LOAD PATH TO STRUCTURAL STEEL, THE FOUNDATION, PODIUM FRAMING, OR OTHER ADEQUATE SUPPORT. WF24 WHERE DECKS OR BALCONIES ARE WOOD-FRAMED, IF THE RAILING RELIES ON A CONNECTION TO THE WOOD BALCONY BEAMS OR RIM JOISTS FOR STABILITY AND LOAD RESISTANCE, THEN THE RAILING DESIGNER SHALL CHECK TORSION AND OTHER EFFECTS ON THE EDGE BEAMS OR JOISTS AND THEIR CONNECTIONS. WP1 ALL PLYWOOD AND ORIENTED STRAND BOARD (OSB) CONSTRUCTION SHALL BE IN ACCORDANCE WITH THR AMERICAN PLYWOOD ASSOCIATION (APA) SPECIFICATIONS AND DOC PS1 OR PS2 WP2 ALL ROOF SHEATHING FOR ROOFS WITH SLOPES GREATER OR EQUAL TO 3-IN-12 SHALL BE 5/8" APA-RATED EXTERIOR SHEATHING. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY USE OF PANEL CLIPS OR BLOCKING BETWEEN FRAMING, UNLESS OTHERWISE NOTED. FASTEN ROOF SHEATHING WITH 8D COMMON (0.131" x 2 1/2") NAILS SPACED AT 6" O.C. AT SUPPORTED EDGES AND AT 12" O.C. AT INTERMEDIATE SUPPORTS. FOR ROOFS WITH SLOPES LESS THAN 3-IN-12, ROOF SHEATHING SHALL BE 3/4" NOMINAL (23/32" ACTUAL) APA-RATED SHEATHING. FASTEN 3/4" NOMINAL SHEATHING WITH 10D COMMON (0.148" x 3") NAILS SPACED AT 6" O.C. AT SUPPORTED EDGES AND AT 12" O.C. AT INTERMEDIATE SUPPORTS. WP3 ALL FLOOR SHEATHING/SUBFLOOR SHALL BE 3/4" NOMINAL (23/32" ACTUAL) APA-RATED STURD-I-FLOOR WITH TONGUE AND GROOVE EDGES, UNLESS OTHERWISE NOTED. FASTEN FLOOR SHEATHING/SUBFLOOR WITH 10D COMMON (0.148" x 3") NAILS SPACED AT 6" O.C. AT SUPPORTED EDGES AND AT 12" O.C. AT INTERMEDIATE SUPPORTS. FIELD-GLUE USING ADHESIVES MEETING APA SPECIFICATION AFG-01 APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WP4 THE USE OF HEAVILY LOADED DRYWALL CARTS OR SIMILAR CONVEYANCES TO TRANSPORT BUILDING MATERIALS AND/OR DEBRIS CAN EXCEED THE APA PS2 CONCENTRATED LAOD TEST STANDARD CAPACITY. IN AREAS SUBJECT TO CONSTRUCTION CART TRAFFIC, THE CONTRACTOR SHALL PLACE A TEMPORARY LAYER OF DRY WOOD STRUCTURAL PANEL TO HELP AVOID FAILURES OF THE FLOOR PANELS. REFER TO TECHNICAL NOTE TT-024, FEB 2008. WP5 ALL STRUCTURAL WOOD PANEL SHEATHING SHALL BE 7/16" APA-RATED PS2 SHEATHING UNLESS OTHERWISE NOTED. FASTEN WALL SHEATHING WITH 8D COMMON (0.131" x 2 1/2") NAILS SPACED AT 6" O.C. AT SUPPORTED EDGES AND AT 12" O.C. AT INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE IN SHEAR WALL SCHEDULE. WP6 ALL GYPSUM WALL BOARD WALL SHEATHING TO BE 5/8" UNLESS OTHERWISE SHOWN OR NOTED ON THE ARCHITECTURAL DRAWINGS. FASTEN SHEATHING WITH 8D COOLER NAILS OR 0.120" x 2 3/8" WALLBOARD NAILS SPACED AT 6" O.C. AT SUPPORTED EDGES AND AT 12" AT INTERMEDIATE SUPPORTS, UNLESS OTHERWISE NOTED IN THE SHEAR WALL SCHEDULE. WP7 PROVIDE 2x BLOCKING WITH SPECIFIED EDGE NAILING AT UNSUPPORTED PANEL EDGES AS FOLLOWS: A. ROOFS AND FLOORS -NOT REQUIRED UNLESS INDICATED ON THE PLANS, NOTES, OR DETAILS B. WALLS -REQUIRED AT ALL WOOD PANEL JOINTS, UNLESS NOTED OTHERWISE WP8 UNLESS OTHERWISE NOTED OR SHOWN, INSTALL FLOOR AND ROOF SHEATHING WITH THE LONG DIMENSION OF THE PANEL ACCROSS SUPPORTS AND WITH THE PANEL CONTINUOUS OVER TWO OR MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING AT PANEL ENDS AND EDGES UNLESS OTHERWISE RECOMMENDED BY THE SHEATHING MANUFACTURER. WP9 WOOD STRUCTURAL PANELS USED IN SHEAR WALLS SHALL BE 4'x8' MINIMUM. THESE PANELS MAY ONLY BE CUT AT WALL OR WALL OPENING BOUNDARIES. ALL PANEL EDGES SHALL FALL ON FRAMING MEMBERS. BLOCK ALL HORIZONTAL JOINTS AND FASTEN WITH EDGE NAILING. WP10 IN ALL WOOD-FRAMED ROOF, FLOOR, CEILING, AND WALL AREAS WHERE WOOD SHEATHING AND/OR GYPSUM WALL BOARD SHEATHING IS APPLIED, ATTACH THE SHEATHING TO ALL WOOD FRAMING MEMBERS REGARDLESS OF THE CLOSENESS OF THEIR SPACING. WHERE GYPSUM WALL BOARD SHEATHING IS APPLIED OVER RESILIENT CHANNELS, ATTACH THE RESILIENT CHANNELS TO ALL FRAMING MEMBERS. WP11 INSTALLATION OF GYPSUM PANEL PRODUCTS MUST FOLLOW THE REQUIREMENTS OF THE GYPSUM ASSOCIATION. THE "FLOATING INTERIOR ANGLES" METHOD AS DESCRIBED IN GA-216 SHALL BE USED TO AVOID NEGATIVE EFFECTS FROM POTENTIAL TRUSS UPLIFT, WOOD SHRINKAGE, AND OTHER CAUSES OF FRAMING MOVEMENT. AN EXTENSIVE DISCUSSION OF THIS ISSUE CAN BE FOUND IN THE TTB "PARTITION SEPARATION PREVENTION AND SOLUTIONS" FROM THE STRUCTURAL BUILDING COMPONENTS ASSOCIATION. THE CONTRACTOR SHALL FAMILIARIZE HIMESLF WITH THE CONTENT OF THESE DOCUMENTS BEFORE BEGINNING THE INSTALLATION OF GYPSUM PANEL PRODUCTS. WP12 THE REQUIREMENTS SHOWN ON THE STRUCTURAL DRAWINGS FOR SHEATHING ARE THE MINIMUM REQUIREMENTS FOR THE STRUCTURAL NEEDS OF THE STRUCTURE. THEY DO NOT ACCOUNT FOR ALL POSSIBLE QUALITY, AESTHETIC, AND OTHER CONSIDERATIONS. THE CONTRACTOR IS EXPECTED TO BE FAMILIAR WITH APA'S CONSTRUCTION GUIDELINES AND OTHER COMMON CONSTRUCTION PRACTICES NECESSARY TO AVOID QUALITY AND AESTHETIC ISSUES. THE USE OF PANEL EDGE GAPS TO AVOID PANEL BUCKLING IS AN EXAMPLE. ANOTHER IS THE ALLOWANCE OF THE APPLICATIONS OF WOOD SHEATHING TO WALLS WITH THE FACE GRAIN VERTICAL, WHICH CAN LEAD TO GREATER BUCKLING POSSIBILITIES. THE CONTRACTOR WILL NEED TO CONSIDER STUD SIZE, STUD SPACING, AND SHEATHING THICKNESS IN THESE SITUATIONS. WT1 WOOD TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURER TO SUPPORT THE FOLLOWING LOADS: A. ROOF TRUSSES: TOP CHORD LOADING: LIVE (SNOW) LOAD:20 PSF + DRIFT EFFECTS DEAD LOAD:10 PSF BOTTOM CHORD LOADING: DEAD LOAD:5 PSF TRUSSES SHALL MEET THE FOLLOWING DEFLECTION CRITERIA, UNLESS OTHERWISE NOTED. MAXIMUM LIVE LOAD DEFLECTION SHALL NOT EXCEED: A. ROOFS: L/360 (MAX TOTAL LOAD DEFLECTION = 1.75") B. FLOORS: L/480 (WHERE LL<60 PSF, ELSE L/360) C. ROOF & FLOOR: MAX LIVE LOAD DEFLECTION = 1.25" MAX TOTAL LOAD DEFLECTION = 1.75" WT2 WOOD TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURER IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE NATIONAL DESIGN SPECIFICATION OF THE AMERICAN FOREST & PAPER ASSOCIATION, THE DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES OF THE TRUSS PLATE INSTITUTE (TPI), WOOD STRUCTURAL BUILDING COMPONENTS ASSOCIATEION (SBCA), AND THE INDIANA BUILDING CODE. WT3 WOOD TRUSSES SHALL BE FABRICATED BY A TRUSS MANUFACTURER WHO MAINTAINS WRITTEN PROCEDURAL AND QUALITY CONTROL MANUALS AND ENGAGES IN PERIODIC AUDITING OF FABRICATION PRACTICES AND INSPECTIONS AS REQUIRED BY ANSI/TPI 1, CHAPTER 3. IN ADDITION, THE TRUSS MANUFACTURER SHALL ENGAGE IN PERIODIC, UNANNOUNCED AUDITING BY AN APPROVED THIRD-PARTY INSPECTION AGENCY SUCH AS TPI FOR REVIEW. IF THE TRUSS MANUFACTURER CANNOT FULFILL THESE REQUIREMENTS, THE SER MAY, AT HIS DISCRETION, REQUIRE OR ACCEPT FROM THE TRUSS MANUFACTURER, A LETTER SEALED BY A PROFESSIONAL ENGINEER (SSE) REGISTERED IN THE STATE OF INDIANA VERIFYING HIS INSPECTION OF THE MANUFACTURED WOOD TRUSSES SUPPLIED FOR THIS PROJECT. THE SSE SHALL VERIFY THAT THE TRUSSES ARE IN COMPLIANCE WITH THE QUALITY STANDARDS OF ANSI/TPI1, CHAPTER 3. THE SSE SHALL HAVE SIGNIFICANT PRIOR EXPERIENCE IN THE INSPECTION OF METAL PLATE-CONNECTED WOOD TRUSSES. WT4 WOOD MATERIALS SHALL BE SOUTHERN PINE, SPF, OR DOUGLAS FIR-LARCH AND SHALL BE KILN-DRIED AND USED AT 19% MAXIMUM MOISTURE CONTENT. PROVIDE GRADE NO. 2 OR BETTER AS REQUIRED TO SATISFY STRESS REQUIREMENTS. WT5 CONNECTOR PLATES SHALL BE NOT LESS THAN 0.036 INCHES (20 GAUGE) IN COATED THICKNESS, SHALL MEET OR EXCEED ASTM GRADE A OR HIGHER, AND SHALL BE HOT-DIP GALVANIZED ACCORDING TO ASTM A653 (COATING G60). MINIMUM YIELD STRESS SHALL BE 33,000 PSI. WT6 TRUSSES SHALL BE FABRICATED IN A PROPERLY EQUPPED MANUFACTURING FACILITY OF A PERMANENT NATURE. TRUSSES SHALL BE MANUFACTURED BY EXPERIENCED WORKMEN, USING PRECISION CUTTING, JIGGING, AND PRESSING EQUIPMENT UNDER THE REQUIREMENTS OF QUALITY CONTROL AS INDICATED IN ANSI/TPI 1, CHAPTER 3. WT7 SECONDARY BENDING STRESSES IN TOP AND BOTTOM CHORDS DUE TO DEAD, LIVE, AND WIND LOADS SHALL BE CONSIDERED IN THE DESIGN. OAD DURATION FACTORS SHALL BE PER THE "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". WT8 ALL GIRDER TRUSSES SUPPORTING OTHER TRUSSES OR 2x FRAMING MEMBERS SHALL BE A MINIMUM OF (2) PLIES, UNLESS OTHERWISE APPROVED. REFER TO THE MANUFACTURER'S TRUSS DESIGN DRAWING FOR GIRDER PLY-TO-PLY CONNECTION REQUIREMENTS. ATTACH FRAMING MEMBERS OR LOADS ONLY AFTER ALL GIRDER PLIES ARE IN PLACE AND PROPERLY FASTENED TOGETHER, AND THE TRUSS IS PROPERLY BRACED TO PREVENT LATERAL DISPLACEMENT. REFER TO BCSI-B9 "MILTI-PLY GIRDERS" AS PUBLISHED BY THE SBCA AND TPI FOR ADDITIONAL INFORMATION. WT9 TRUSS-TO-GIRDER CONNECTION INFORMATION SHALL BE SHOWN ON THE MANUFACTURER'S TRUSS DESIGN DRAWING OF THE CARRIED TRUSS OR GIRDER, OR THE MANUFACTURER'S TRUSS PLACEMENT DRAWING. UNLESS OTHERWISE APPROVED, ALL TRUSS/JOIST HANGERS, STRAPS, TIES, ETC. SHALL BE MANUFACTURED BY THE SIMPSON STRONG-TIE COMPANY. WT10 UNLESS OTHERWISE SHOWN OR NOTED, ALL TRUSSES SHALL BE ANCHORED AT EACH BEARING USING A MECHANICAL FASTENER. FOR ROOF TRUSSES, UNLESS OTHERWISE NOTED, PROVIDE A SDWC SCREW ANCHOR BY SIMPSON STRONG-TIE, INSTALLED AS SHOWN IN THE DETAILS IN THESE PLANS. WT11 WOOD TRUSSES SHALL BE ERECTED IN ACCORDANCE WITH THE TRUSS MANUFACTURER'S REQUIREMENTS. THIS WORK SHALL BE PERFORMED BY A QUALIFIED AND EXPERIENCED CONTRACTOR. TRUSS ERECTION BY AN INEXPERIENCED OR NON-QUALIFIED CONTRACTOR CAN RESULT IN CONSTRUCTION COLLAPSE AND/OR SERIOUS INJURY AND DAMAGE. WT12 WHERE LONG SPAN TRUSSES (GREATER THAN 60' SPAN) ARE USED, REFER TO BCSI SPECIAL RECOMMENDATIONS AND REQUIREMENTS FOR THE INSTALLATION AND TEMPORARY RESTRAINT/BRACING OF LONG SPAN TRUSSES. FOLLOW ALL BCI REQUIREMENTS FOR THE INSTALLATION AND TEMPORARY RESTRAINT/BRACING OF LONG SPAN TRUSSES INCLUDING CONSULTING A REGISTERED PROFESSIONAL ENGINEER FAMILIAR WITH THE INSTALLATION AND TEMPORARY RESTRAINT/BRACING OF LONG SPAN TRUSSES. WT13 THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND PERMANENT BRACING/RESTRAINT AS REQUIRED FOR SAFE ERECTION AND PERFORMANCE OF THE TRUSSES. THE GUIDELINES SET FORTH BY THE FOLLOWING JOINT PUBLICATION OF THE TRUSS PLATE INSTITUTE (TPI) AND THE STRUCTURAL BUILDING COMPONENTS ASSOCIATION (SBCA) SHALL BE ADHERED TO UNLESS OTHERWISE SHOWN IN THE CONTRACT DOCUMENTS. BCSI-B1 GUIDE FOR HANDLING, INSTALLING, AND BRACING OF METAL PLATE CONNECTED WOOD TRUSSES BCSI-B2 TRUSS INSTALLATION AND TEMPORARY BRACING BCSI-B3 WEB MEMBER PERMANENT BRACING/ WEB REINFORCEMENT BCSI-B4 CONSTRUCTION LOADING BCSI-B5 TRUSS DAMAGE, JOBSITE MODIFICATIONS, AND INSTALLATION ERRORS BCSI-B6 GABLE END FRAME BRACING BCSI-B7 TEMPORARY AND PERMANENT BRACING FOR PARALLEL CHORD TRUSSES BCSI-B8 TOE NAILING FOR UPLIFT REACTIONS BCSI-B9 MULTI-PLY GIRDERS BCSI-B10 POST FRAME TRUSS INSTALLATION AND BRACING BCSI-B11 FALL PROTECTION AND WOOD TRUSSES WT14 UNLESS OTHERWISE SHOWN OR NOTED, PERMANENT BRACING/RESTRAINT SHALL CONSIST OF 2x4 MINIMUM STRESS-GRADED MEMBERS SPANNING A MINIMUM OF FOUR TRUSSES AND NAILED AT EACH INTERSECTION WITH A MINIMUM OF (2) 16D NAILS. LAP CONTINUOUS BRACING/RESTRAINT A MINIMUM OF 2'-0" (2 TRUSSES). WT15 REFER TO THE MANUFACTURER'S TRUSS DESIGN DRAWING FOR WEB MEMBERS REQUIRING WEB MEMBER PERMANENT WEB RESTRAINT OR REINFORCEMENT. CONTINUOUS LATERAL RESTRAINTS MUST ALWAYS BE DIAGONALLY BRACED FOR RIGIDITY. WT16 WHEREVER POSSIBLE, THE TEMPORARY ERECTION BRACING AS DESCRIBED IN BCSI-B2 SHALL BE LEFT IN PLACE TO FUNCTION AS PERMANENT BRACING. WT17 'T' OR 'L' REINFORCEMENT OF THE TYPE DESCRIBED IN BCSI-B3 SHALL BE USED AS THE MEANS OF RESISTING WEB MEMBER BUCKLING FORCES IN GIRDER TRUSSES AND SMALL- QUANTITY TRUSSES. GIRDER TRUSSES SHALL BE THOSE TRUSSES SUPPORTING OTHER TRUSSES, BEAMS, OR FRAMING, OR TRUSSES MORE THAN 24" O.C. SMALL QUANTITY TRUSSES SHALL BE THOSE WHERE BECAUSE OF THE SMALL QUANTITY OF SIMILAR TRUSSES WITH ALIGNED WEB MEMBERS REQUIRING BRACING/RESTRAINT, THE INSTALLATION OF CONTINUOUS LATERAL RESTRAINTS AND THE DIAGONAL BRACING FOR THE CONTINUOUS LATERAL BRACES IS IMPRACTICAL USING THE METHODS OF BCSI. SUCH 'T' OR 'L' REINFORCEMENT SHALL BE DESIGNED BY THE TRUSS DESIGN ENGINEER AND SHOWN ON THE SEALED TRUSS DESIGN DRAWINGS. WT18 DESIGN ALL WOOD TRUSS BEARINGS USING THE COMPRESSION PERPENDICULAR TO GRAIN VALUE OF THE TRUSS LUMBER OR THE WALL PLATE LUMBER/NAILER, WHICHEVER IS LESS. THE BEARING LENGTH OR AREA SHOWN ON THE SEALED TRUSS DRAWINGS SHALL BE BASED ON THIS LESSER VALUE. USE ADDITIONAL TRUSS PLIES OR TRUSS BEARING ENHANCEMENT DEVICES TO ACHIEVE THE REQUIRED BEARING AREA. IF THE BEARING ENHANCEMENT DEVICE HAS A VALID ESR REPORT, IT MAY BE SHOWN ON THE TRUSS PLACEMENT PLAN INSTEAD OF BEING SHOWN ON THE SEALED TRUSS DRAWINGS. WT19 TRUSSES WHICH ARE TOO TALL FOR DELIVERY TO THE JOBSITE IN ONE PIECE MAY BE MANUFACTURED IN TWO OR MORE SECTIONS AND "PIGGYBACKED" AT THE JOBSITE. THE CONTRACTOR MUST INSTALL ALL TEMPORARY AND PERMANENT BRACING FOR THE LOWER SUPPORTING TRUSSES AS SHOWN ON THE MANUFACTURER'S TRUSS DESIGN DRAWING AND/OR THE CONTRACT DOCUMENTS BEFORE INSTALLING THE CAP TRUSSES. THE CONNECTIONBETWEEN THE CAP AND BASE TRUSS SHALL BE SHOWN ON THE SEALED TRUSS DESIGN DRAWING. PROVIDE, AS A MINIMUM, 4x2 SLEEPERS LAID FLAT ON THE TOP CHORD OF THE SUPPORTING TRUSSES, SPACED AT 24" O.C. MAXIMUM AND NAILED TO THE TOP CHORD WITH A MINIMUM OF (2) 16D NAILS (SEE TRUSS DESIGN DRAWING FOR ANY OTHER OR ADDITIONAL REQUIREMENTS). PROVIDE 48" O.C. (BRACE TO BRACE) DIAGONAL BRACING AT 45-DEGREES TO BRACE THE SLEEPERS. INSTALL DIAGONAL BRACES ON THE BOTTOM SIDE OF THE TOP CHORD IN THE CAP AREA, UNLESS OTHERWISE SPECIFIED BY THE TRUSS DESIGN ENGINEER. WT20 WHEN INDICATED ON THE PLANS OR WHEN A CAP TRUSS LENGTH EXCEEDS 20', IN LIEU OF THE SLEEPERS AND DIAGONAL BRACING INDICATED ABOVE, STRUCTURAL WOOD SHEATHING ON THE TOP CHORD OF THE BASE TRUSS IN THE CAP AREA SHALL BE USED AS THE MEANS OF BRACING/RESTRAINING THE BASE TRUSS IN THE CAP AREA. THE CONNECTION BETWEEN THE CAP AND THE BASE TRUSS, SHOWN ON THE SEALED TRUSS DESIGN DRAWING, SHALL TAKE THIS INTO ACCOUNT. CAP TRUSSES MUST BE DIRECTLY ABOVE BASE TRUSSES. WT21 TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, DRILLED, NOR OTHERWISE ALTERED IN ANY WAY WITHOUT THE WRITTEN APPROVAL OF THE TRUSS DESIGN ENGINEER. WT22 WHERE TRUSSES AND/OR WOOD JOISTS AND RAFTERS ARE TO BE SUPPORTED BY STEEL BEAMS, PROVIDE CONTINUOUS 2x NAILER(S) FIELD BOLTED TO THE TOP OF THE STEEL BEAM WITH 1/2" DIAMETER CARRIAGE BOLTS SPACED ATA MAXIMUM OF 24" O.C. AND STAGGERED EACH SIDE OF THE BEAM WEB. WIDTH OF NAILER TO EQUAL WIDTH OF BEAM FLANGE + 1/2"/-1/4", UNLESS OTHERWISE NOTED. CARRIAGE BOLTS MAY BE OVER-TIGHTENED TO COMPRESS THE ROUNDED HEAD IN THE NAILER TO FACILITATE INSTALLATION OF CONTINUOUS BAND/RIM JOISTS, RAFTERS, TRUSSES, ETC. WT23 COORDINATE FINAL TRUSS LAYOUT AND TRUSS WEB MEMBER CONFIGURATION WITH MECHANICAL, ELECTRICAL, AND PLUMBING TRADES. KEEP ALL MECHANICAL CHASES FREE OF TRUSSES. ALIGN FLOOR TRUSS WEB LAYOUT INCLUDING OPEN VIERENDEEL PANELS FOR ALL PARALLEL TRUSSES WITH SIMILAR SPANS TO PROVIDE MAXIMUM FLEXIBILITY OF MEP INSTALLATION. DO NOT LOCATE TRUSSES AT PARALLEL PLUMBING WALLS. WT24 SUBMIT COMPLETE SHOP DRAWINGS FOR ALL WOOD TRUSSES SHOWING MEMBER SIZES, SPECIES, GRADE, MOISTURE CONTENT, SPAN, CAMBER, DIMENSIONS, NUMBER OF PLIES AND TRUSS PLU-TO-PLY CONNECTIONS, REACTIONS AND BEARING REQUIREMENTS, CHORD PITCH, RESTRAINT/BRACING REQUIREMENTS, LOADINGS INCLUDING ANY GIRDER LOADS, FIELD ASSEMBLY OF MULTI-PART TRUSSES, AND REQUIRED CAP TRUSS TO BASE TRUSS CONNECTIONS. ALL REQUIRED INFORMATION MUST BE COMPLETE ON THE INDIVIDUAL TRUSS DRAWING. NO REFERENCE TO ANOTHER DRAWING SHEET, NOTE EXTERNAL TO THAT INDIVIDUAL TRUSS DRAWING, OR DETAIL NOT SHOWN ON THAT INDIVIDUAL TRUSS DRAWING MAY BE USED TO CONVEY ANY OF THIS REQUIRED INFORMATION. SHOP DRAWINGS SHALL BE SUBMITTED TO THE SER AND SHALL BEAR THE SEAL OF A PROFESSIONAL ENGINEER (SSE) REGISTERED IN THE STATE OF INDIANA. 1. 1 1/2" MINIMUM PENETRATION INTO FRAMING. 2. DIAPHRAGMS ARE UNBLOCKED UNLESS NOTED OTHERWISE. 3. ALL NAILS ARE COMMON NAILS -SEE SCHEDULE THIS SHEET LOCATION BOUNDARY 8d DIAPHRAGM NAILING SCHEDULES SIZE SPACING 6" PANEL EDGE 8d 6" FIELD 8d 12" ROOF DIAPHRAGM ARCHITECTCONSTRUCTION MANAGERPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONSBID DOCUMENTS 10-26-22 21011 CLIENTS002GENERAL NOTESCARMELTOWNSHIP BLDG.RENOVATION ANDEXPANSIONWOOD FRAMING NOTES STRUCTURAL WOOD PANELS AND SHEATHING NOTES PREFABRICATED METAL PLATE-CONNECTED WOOD TRUSSES 03/10/23