HomeMy WebLinkAboutT000 - SYMBOLS AND ABBREVIATIONSTECHNOLOGY GENERAL NOTES NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTA. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. B. CONTRACT DOCUMENTS CONSIST OF BOTH THE PROJECT MANUAL AND DRAWINGS, AND BOTH ARE INTENDED TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. C. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. D. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. E. THE TECHNOLOGY DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE ARCHITECTURAL AND ENGINEERING DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL AND ENGINEERING DRAWINGS BEFORE THE INSTALLATION OF ENGINEERING WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL AND ENGINEERING DRAWINGS AND THE TECHNOLOGY DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, THE DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL AND ENGINEERING DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. F. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING THE WORK. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. G. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING OR BEGINNING WORK ON THIS PROJECT. H. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. I. ANY DETAILS, SYSTEMS AND/OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST FIRST BE REVIEWED BY THE OWNER AND ARCHITECT/ENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS. J. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE -LATEST EDITION ADOPTED BY STATE HAVING JURISDICTION, AND THE STATE HAVING JURISDICTION ELECTRICAL CODE AMENDMENTS, LOCAL/MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. K. CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR INCORRECT WORK, OR FOR INFRINGEMENT UPON OTHERS WORK, DUE TO A LACK OF COORDINATION. L. COORDINATE LOCATION OF ALL DEVICES TO BE INSTALLED IN CEILINGS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. NOTIFY ENGINEER OF AN CONFLICTS PRIOR TO INSTALLATION. M. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING THEIR AREAS OF CONSTRUCTION. PROJECT AREAS SHALL BE THOROUGHLY CLEANED AND TRASH DISPOSED OF AT THE END OF EACH WORK DAY. THE OWNER'S FACILITIES SHALL NOT BE USED FOR TRASH DISPOSAL. N. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THEIR WORK FROM DUST AND DEBRIS. CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR ALL TECHNOLOGY EQUIPMENT AS REQUIRED TO PROTECT THE TECHNOLOGY EQUIPMENT. O. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL SURFACES AND FINISHED OF THE CONSTRUCTION SITE DURING THE INSTALLATION OF THE TECHNOLOGY SYSTEMS. DAMAGED SURFACES OR FINISHES RESULTING FROM THE PERFORMANCE OF THE WORK OR NEGLIGENCE SHALL BE REPAIRED AT NO COST TO THE OWNER BY THE RESPONSIBLE CONTRACTOR. FINISHES AND SURFACES SHALL BE MADE TO MATCH THE EXISTING FINISHES OR SURFACES TO THE SATISFACTION OF THE OWNER AND ARCHITECT/CONSTRUCTION MANAGER. TELECOMMUNICATIONS OUTLET. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. WHEN INDICATED WITH xV, x INDICATES THE QUANTITY OF COMMUNICATIONS COAXIAL CABLE. TECHNOLOGY SYMBOLS LEGEND SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. KEYNOTE INDICATOR:REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR:REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. EQUIPMENT INDICATOR:REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. DIFFUSER, GRILLE, REGISTER INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. TU-XL.## REFERENCE SYMBOLS DRAWING BLOCK TITLE SECTION LOCATION IN DRAWING MODULE SECTION LOCATION AT SUBSET SHEET DETAIL LOCATION IN DRAWING MODULE DETAIL LOCATION AT SUBSET SHEET LARGE SCALE VIEW LOCATION IN DRAWING MODULE LARGE SCALE VIEW LOCATION AT SUBSET SHEET KEYNOTE INDICATORS EQUIPMENT TYPE NUMERIC CHARACTER RELATES TO ITEM ALPHANUMERIC CHARACTER RELATES TO ASSOCIATED AIR HANDLER (OPTIONAL) AREA LEADER LINE LEADER POINT LEADER DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) REVISION CLOUD REVISION INDICATOR NUMERIC SCALE SEE XXXX REFER TO ADDITIONAL SHEET FOR CONTINUATION FLOOR PLAN OVERLAP BEYOND AREA EXTENSION PLAN PLAN NUMERIC CHARACTER RELATES TO ITEM NORTH ARROW BEYOND AREA EXTENSION ALPHANUMERIC CHARACTER RELATES TO BUILDING LEVEL (OPTIONAL) SCALE: 1/8" = 1'-0" X XX X X X X X X X X N SCHEDULE TYPE AIRFLOW (CUBIC FEET PER MINUTE) XXX-XXX TECHNOLOGY PATHWAY NOTES 1. ALL HORIZONTAL CABLING RUNS SHALL BE SUPPORTED NEATLY WITH CABLE TRAY, CONDUITS, OR J-HOOKS. ALL HORIZONTAL CABLING THAT IS NOT INSTALLED IN CABLE TRAY OR CONDUIT SHALL BE SUPPORTED WITH J-HOOKS. CABLES SHALL NOT LIE ON THE STRUCTURAL STEEL OR SYSTEMS OF THE FACILITY. 2. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL AND SHALL MATCH FIRE RATING OF BARRIER BEING PENETRATED. 3. FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. 4. WHEN CABLE TRAY IS SHOWN ON THE PLANS AND PORTIONS OF CABLE TRAY CANNOT BE INSTALLED DUE TO CONFLICT WITH STRUCTURE, THE CONTRACTOR SHALL PROVIDE (2) 4" C. WITH INSULATED BUSHINGS THAT OVERLAP 1" INTO THE TRAY. 5. CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL USE LINK-SEALS. 6. DEVICES IN GENERAL SHALL BE CENTERED IN WALL SPACE IN WHICH THEY ARE INSTALLED OR THEY SHALL BE SPACED SYMMETRICALLY (FOR EXAMPLE, CENTER DEVICES WHEN MOUNTED ON FACE OF COLUMNS). 7. COORDINATE AND VERIFY LOCATIONS OF DEVICES WITH BLOCK COURSING, FINISH MATERIALS, CASEWORK, ETC. PRIOR TO ROUGH-IN. 8. ALL DEVICE BOXES SHALL BE FLUSH MOUNTED AND ALL RACEWAYS SHALL BE CONCEALED UNLESS NOTED OTHERWISE. CONTRACTOR SHALL CUT AND PATCH EXISTING WALLS WITH EXTREME CAUTION, SO AS TO MINIMIZE INVASIVENESS OF INSTALLATION. ROUTE RACEWAYS SO AS TO MINIMIZE THE AMOUNT OF CUTTING AND PATCHING REQUIRE. PATCHING SHALL COMPLY WITH ALL BID DOCUMENT REQUIREMENTS. 9. CONDUIT RUNS SHALL HAVE NO MORE THAN 180 DEGREES OF BENDS WITHOUT A PULL BOX. WHERE CONDUIT IS SHOWN AND/OR SPECIFIED, CONTRACTOR SHALL PROVIDE ALL PULL BOXES SHOWN ON THE DRAWINGS AND ADDITIONAL PULL BOXES AS FOLLOWS: A. EVERY 180 DEGREES OF CONDUIT BEND B. EVERY 100 FEET OF CONDUIT PATH 10. PROVIDE PLASTIC INSULATED BUSHINGS ON ALL CONDUIT STUB'S. BUSHINGS SHALL ALSO BE PROVIDED FOR ALL CONDUITS WHETHER ABOVE OR BELOW CEILING OR AT FLOOR LEVEL. IT IS THE COMMUNICATIONS CABLING CONTRACTORS RESPONSIBILITY TO ENSURE BUSHINGS HAVE BEEN PROVIDED ON ALL CONDUITS PRIOR TO PULLING CABLES. IF CONDUITS ARE FOUND TO BE WITHOUT BUSHINGS, COMMUNICATIONS CABLING CONTRACTOR SHALL REMOVE CABLING, PROVIDE BUSHINGS AND REPLACE WITH NEW CABLING. FIRESTOPPING NOTES 1. THE CONTRACTOR SHALL FIRESTOP ALL PENETRATIONS OF ALL FLOORS AND ALL WALLS WHICH EXTEND TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE.FIRESTOPPING SHALL BE ACCOMPLISHED AFTER ALL CABLES ARE PULLED (ALL SYSTEMS) USING UL CLASSIFIED SYSTEMS WITH FIRE RATING EQUAL TO OR GREATER THAN THE FIRE RATING OF THE FLOOR OR WALL ASSEMBLY PENETRATED. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS. THE CONTRACTOR SHALL SUBMIT A MANUFACTURER'S STANDARD DETAIL FOR EACH TYPE OF FLOOR AND WALL PENETRATION REQUIRED FOR THIS PROJECT. ALL OTHER PENETRATIONS OR OPENINGS IN NON-FIRE RATED WALLS SHALL BE REPAIRED AND SEALED WITH MATERIALS TO MATCH THE EXISTING CONSTRUCTION. SYMBOL DESCRIPTION ROUGH-IN REQUIREMENTS MOUNTING HEIGHT (UNO) ROUGH-IN DETAIL TECHNOLOGY DETAIL PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG OR DOUBLE GANG MUD RING. PROVIDE TWO (2) 1" C.'S STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. xD +18"1, 2, & 3/T501 1/T503 VIDEO OUTPUT LOCATION. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. INSTALL JACKS IN SURFACE MOUNT BISCUIT. WHEN INDICATED WITH xV, x INDICATES THE QUANTITY OF COMMUNICATIONS COAXIAL CABLE. xD +60" 5/T501 1/T503VO xD TELECOMMUNICATIONS OUTLET WITH WALL PLATE. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. +44" PROVIDE CHIEF PAC525W WALL BOX. PROVIDE ONE (1) 1-1/4" CONDUIT STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. FLOORBOX DATA LOCATION. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. xD PROVIDE FLOORBOX WITH TWO (2) 1-1/4"C'S STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. REFER TO ROUGH-IN DETAILS FOR MORE INFORMATION -6/T501 - CEILING MOUNTED WIRELESS ACCESS POINT LOCATION. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. PROVIDE 4" SQUARE BOX WITH BLANK METAL COVER PLATE. METAL BOX SHALL BE SUPPORTED FROM WALL ABOVE ACCESSIBLE CEILING), OR STRUCTURE, OR UNISTRUT. METAL BOX SHALL NOT BE INSTALLED LOOSE ON CEILING TILES. ---xD xD WALL MOUNTED WIRELESS ACCESS POINT LOCATION. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. +96" CARD READER. CARD READER PROVIDED BY OWNER'S PREFERRED CONTRACTOR. SECURITY SYMBOLS LEGEND SYMBOL DESCRIPTION ROUGH-IN REQUIREMENTS MOUNTING HEIGHT (UNO) ROUGH-IN DETAIL TECHNOLOGY DETAIL +42"1 & 2/T502 ELECTRONIC STRIKE.- DOOR CONTACT.- ELECTRONIC LATCH.- - WALL MOUNTED IP VIDEO SURVEILLANCE CAMERA LOCATION. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. CAMERA PROVIDED BY OWNER'S PREFERRED CONTRACTOR. PROVIDE 4" SQUARE BOX WITH BLANK METAL COVER PLATE. METAL BOX SHALL BE SUPPORTED FROM WALL ABOVE ACCESSIBLE CEILING), OR STRUCTURE, OR UNISTRUT. METAL BOX SHALL NOT BE INSTALLED LOOSE ON CEILING TILES. +96" COORDINATE ROUGH-IN AND CONDUIT INTO DOOR FRAME WITH DOOR HARDWARE MANUFACTURER. CEILING MOUNTED IP VIDEO SURVEILLANCE CAMERA LOCATION. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. CAMERA PROVIDED BY OWNER'S PREFERRED CONTRACTOR. xD xD COORDINATE ROUGH-IN AND CONDUIT INTO DOOR FRAME WITH DOOR HARDWARE MANUFACTURER. COORDINATE ROUGH-IN AND CONDUIT INTO DOOR FRAME WITH DOOR HARDWARE MANUFACTURER. TECHNOLOGY ADDITIONAL CABLING NOTE A. PROVIDE TEN (10) ADDITIONAL 200 FOOT COPPER COMMUNICATIONS COPPER HORIZONTAL CABLING RUNS. INCLUDE JACKS AT BOTH ENDS, LABELING, AND TESTING. THE ADDITIONAL DROPS ARE TO BE INSTALLED AS DIRECTED BY THE ENGINEER. - -- - - - - 1 & 5/T501 & AND EMT ELECTRICAL METALLIC TUBING ETR EXISTING TO REMAIN OD OUTSIDE DIAMETER °F DEGREES FAHRENHEIT OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED EX EXISTING FLR FLOOR AFC ABOVE FINISHED COUNTER AFF ABOVE FINISHED FLOOR FT FOOT, FEET AFG ABOVE FINISHED GRADE G GROUND PVC POLYVINYL CHLORIDE CONDUIT/PIPE GC GENERAL CONTRACTOR ANSI AMERICAN NATIONAL STANDARDS INSTITUTE RGS RIGID GALVANIZED CONDUIT ARCH ARCHITECT GRD GROUND RM ROOM GND GROUND AVG AVERAGE BAS BUILDING AUTOMATION SYSTEM HORIZ HORIZONTAL SF SQUARE FOOT SPEC SPECIFICATION BLDG BUILDING HR HOUR(S) SQ SQUARE BMS BUILDING MANAGEMENT SYSTEM BSMT BASEMENT Hz HERTZ STD STANDARD C CONDUIT ID INSIDE DIAMETER TBD TO BE DETERMINED IN INCH, INCHES TBI TO BE INSTALLED INT INTERIOR TBR TO BE REMOVED TC TEMPERATURE CONTROLS TCC TEMPERATURE CONTROLS CONTRACTOR CLG CEILING TEMP TEMPERATURE LBS POUNDS TYP TYPICAL MAX MAXIMUM MC MECHANICAL CONTRACTOR UON UNLESS OTHERWISE NOTED MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS VERT VERTICAL MTD MOUNTED DWG DRAWING NA NOT APPLICABLE WP WEATHERPROOF EA EACH NEC NATIONAL ELECTRIC CODE W/ WITH EC ELECTRICAL CONTRACTOR NIC NOT IN CONTRACT W/O WITHOUT NOM NOMINAL EL ELEVATION NTS NOT TO SCALE ABBREVIATIONS AND TERMS WAP EL CR ES DC WAP PANIC BUTTON. PANIC BUTTON PROVIDED BY OWNER'S PREFERRED CONTRACTOR.+44"--PB PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. J xD JUNCTION BOX FOR FURNITURE FEED REFER TO FURNITURE FEED ROUGH-IN DETAILS FOR MORE INFORMATION ON EXACT ROUGH- IN REQUIREMENTS. PROVIDE PLASTIC BUSHING AND PULL STRINGS IN ALL CONDUITS.-4/T501 - HORIZONTAL DATA CABLING COLOR LEGEND SYSTEM TERMINATION (RJ-45) CABLE GRAYDATAORANGE PATCH CABLE BLACK GRAYWIRELESSORANGE PURPLE GRAYIP CAMERA ORANGE YELLOW 1 & 3/T501 1 & 3/T501 1/T503 - RS ROOM SCHEDULE LOCATION. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. COORDINATE TERMINATION REQUIREMENTS WITH AV CONTRACTOR. xD PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. COORDINATE EXACT ROUGH-IN LOCATION AND REQUIREMENTS WITH OWNER'S AV VENDOR PRIOR TO INSTALLATION. +44"1 & 3/T501 - W xDWP TELECOMMUNICATIONS OUTLET WITH WEATHER PROOF COVER. WHEN INDICATED WITH xD, x INDICATES THE QUANTITY OF COMMUNICATIONS COPPER HORIZONTAL CABLE. PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG OR DOUBLE GANG MUD RING. PROVIDE TWO (2) 1" C.'S STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. +18"1, 2, & 3/T501 1/T503 GRAYAVGREEN GREEN TELECOMMUNICATIONS CONDUIT SLEEVE. CONDUIT SIZE SHALL BE 2" UNLESS NOTED OTHERWISE.---- SP WALL MOUNTED VOLUME CONTROL. VOLUME CONTROL PROVIDED BY OWNER'S PREFERRED CONTRACTOR. SPEAKER SYMBOLS LEGEND SYMBOL DESCRIPTION ROUGH-IN REQUIREMENTS MOUNTING HEIGHT (UNO) ROUGH-IN DETAIL +44" WALL MOUNTED SPEAKER. SPEAKER PROVIDED BY OWNER'S PREFERRED CONTRACTOR.+96"PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. TECHNOLOGY DETAIL - - xV xV PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS. 1 & 2/T502 1 & 2/T502 1 & 2/T502 PROVIDE 2-GANG, 3.5" DEEP BOX WITH SINGLE GANG MUD RING. PROVIDE ONE (1) 1" C. STUBBED ABOVE ACCESSIBLE CEILING WITH PLASTIC BUSHING AND PULL STRINGS.1 & 3/T501VC 1 & 3/T501 ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS2 WEST MAIN STREET O: 317.810.1502CARMEL, IN 460322101 10-26-2022 BID DOCUMENTS T000SYMBOLS ANDABBREVIATIONSCLAY TOWNSHIPCENTER10701 North CollegeAvenueCarmel, IN# DESCRIPTION DATE 03/10/23