Loading...
HomeMy WebLinkAboutT101 - FIRST FLOOR TECHNOLOGY PLANK-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA RAMP UP RAMP UP RAMP UP VO WAP WAP WAP WAP CREL DC CR CR VO CR EL DC CR CRCRDCELVO VO VOVOVOVO PBDC CRELCRDC CR J SPCR DC DC EL DC EL DC WAP JJ J J 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 4D 2D +60" 2D 1 1 2 GIS TECH OFFICE 118 GIS DIRECTOR OFFICE 117 SYSTEM ADMIN OFFICE 116 DIRECTOR OFFICE 115 ADMIN OFFICE 114 EXIST. COFFEE/ BREAK ? WORK SPACE 105 CONFERENCE 112 RECEPTION 113EXIST. OPEN CONFERENCE ? Room 11 Room 12 Room 13 Room 14 EXIST. RESTROOM ? EXIST. RESTROOM ? Room 17 Room 18 Room 19 Room 28 Room 29 Room 30 NEW BREAK ROOM 111 OFFICE 110 OFFICE 109 OFFICE 108 WORK SPACE 102 Room 36 Room 37 Room 38 Room 39 EXIST. TRUSTEE ? Room 41 Room 42 IT DATA ROOM 106 Room 44 Room 45 CORRIDOR 107 STAGING/ STORAGE 104 PAINT BOOTH 101 STAGING/ STORAGE 103 EXIST. TRAINING ? NEW GARAGE 100 T401 1 MDF 1D +48" 1D 1D 1D 1D +15'-0" +15'-0" +15'-0" +12'-0" 2D 1 2D 1 2D 2D +44" +44" 2D 1D 2D 2D 2D +60" +60" +60" 4D4D +44" 2D2D2D2D RS 1D 3 2D 2D 2D 2D 2D+60" +60" +60" +60" 2D +60" 1V 1V 1V 1V 1V VC VC VC VC 1V 1V1V VC VC 1V 1V VC 1V 1V VC VC 6D 6D 6D 2D 2D +44" 2D 2D +44" 2D+44" 2D 2D 2D 2D 2D 2D 2D 2D TWO (2) 1-1/4" CONDUITS 4 5 5 5 5 5 5 5 5 5 ONE (1) 2" CONDUIT ROUTED BETWEEN JUNCTION BOXES. ROUTE CONDUIT UP AND ABOVE GARAGE DOOR. COORDINATE CONDUIT ROUTING WITH GARAGE DOOR INSTALLATION. VC +44" +60" +60" 2D +44" 5 5 +44" 1V 5 +60" 1V 5 +60" 1V 5 +60" 2D 2D 4 12D EXISTING DEMARC. LOCATION 5 VC VC TWO (2) 4" CONDUITS TWO (2) 4" CONDUITS ONE (1) 2" CONDUIT FOR FUTURE CAMERA LOCATIONS. ROUTE CONDUIT UP TO JUNCTION BOX LOCATED IN GARAGE. REFER TO CIVIL DRAWINGS FOR MORE INFORMATION. PROVIDE 12"x12"x6" JUNCTION BOX MOUNTED AT +10'-6" PROVIDE 12"x12"x6" JUNCTION BOX MOUNTED AT +10'-6" ONE (1) 2" CONDUIT ROUTED INTO ACCESSIBLE CEILING SPACE PROVIDE 12"x12"x6" JUNCTION BOX MOUNTED +9'-6" (ABOVE CEILING) PROVIDE 12"x12"x6" JUNCTION BOX MOUNTED AT +9'-6". PROVIDE ONE (1) 2" CONDUIT TO JUNCTION BOX ON INTERIOR OF BUILDING FOR ROUTING OF FUTURE CABLING INSTALL SO CENTER OF BOX IS LOCATED AT +7'-6" VC ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS2 WEST MAIN STREET O: 317.810.1502CARMEL, IN 460322101 10-26-2022 BID DOCUMENTS T101FIRST FLOORTECHNOLOGYPLANCLAY TOWNSHIPCENTER10701 North CollegeAvenueCarmel, INN 1/8" = 1'-0" FIRST FLOOR TECHNOLOGY PLAN1 SHEET KEYNOTES 1 PROVIDE CATEGORY 6A DROP(S) FOR THE WIRELESS ACCESS POINT. PROVIDE 20FT. SLACK LOOP COILED NEATLY AND SUPPORTED ABOVE THE CEILING. TERMINATE CABLES WITH RJ45 MODULAR JACKS AND TEST PER SPECIFICATIONS. NOTE LOCATION ON THE RECORD DRAWINGS AND MARK LOCATION ON THE CEILING WITH A GREEN DOT STICKER. 2 PROVIDE ROUGH-IN FOR ROUTING DATA CABLING INTO FURNITURE. SEE DETAIL ON 4/T501 FOR MORE INFORMATION. 3 NEW LOCATION OF EXISTING PANIC BUTTON. OWNER'S PREFERRED INTEGRATOR TO INSTALL NEW PANIC BUTTON. 4 EXISTING CARD READER TO REMAIN. 5 PROVIDE ONE (1) ORANGE RJ-45 JACK AND ONE (1) GREEN RJ-45 JACK AT THIS LOCATION. # DESCRIPTION DATE 03/10/23