Loading...
HomeMy WebLinkAboutEP101 - FIRST FLOOR ELECTRICAL PLANK-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA RAMP UP RAMP UP RAMP UP JJJTTTS S S S S FTTJJJTTT T SFS SFSFS S H HS J G3 G2 G1 G5 G4 H1 L1 T1 1 2 EM1 3 3 4 4 4 CONFERENCE 112 RECEPTION 113 ADMIN OFFICE 114 DIRECTOR OFFICE 115 WORK SPACE 105 OFFICE 110 OFFICE 109 OFFICE 108 GIS DIRECTOR OFFICE 117 GIS TECH OFFICE 118 SYSTEM ADMIN OFFICE 116 STAGING/STORAGE 104 NEW GARAGE 100 SS-1 5 5 6 EM1-30 EM1-30 7 EM1- 24 EM1-26 EM1- 28EM1-28 G4-28,30 G4-31,33 G4-34,36 8 8 9 55 5 L1-1 +60" +60" +60" +60" +60" 10 +60" L1- 3 L1- 3 L1- 5 L1-3 L1- 7 L1-9L1- 9 L1- 9 L1- 9 L1- 9 L1- 9L1-11L1-11L1-11L1-11L1-13 L1-15 L1-17 L1-19 L1-19 L1-19 L1-19 L1-21 L1-7 L1-23 L1-23 11 11 L1-25 L1-25 L1-25 L1-25 L1-25 L1-27L1-27 L1-27 L1-27 L1-29 L1-29 L1-29 L1-29 L1-31 L1-31 L1-31 L1-31 L1-33 L1-33 L1-33 L1-33 L1-35 L1-35 L1-37 L1-37 L1-37 L1-37 L1-10,12,14 L1-16,18,20 ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS2 WEST MAIN STREET O: 317.810.1502CARMEL, IN 460322101 10-26-2022 BID DOCUMENTS EP101FIRST FLOORELECTRICAL PLANCLAY TOWNSHIPCENTER10701 North CollegeAvenueCarmel, INN 1/8" = 1'-0" FIRST FLOOR ELECTRICAL PLAN1 SHEET KEYNOTES 1 EXISTING RECEPTACLE BACK BOX AND CONDUIT WITHIN WALL SHALL BE REUSED FOR NEW MODULAR FURNITURE CONNECTIONS. 2 BACKBOX FROM EXISTING RECEPTACLE SHALL BE REUSED FOR NEW GFCI TYPE RECEPTACLE. 3 PROVIDE 1"CONDUIT DOWN COLUMN TO JUNCTION BOX AT 1'-6" TO PROVIDE POWER TO MODULAR FURNITURE AS SHOWN. 4 PROVIDE 1"CONDUIT DOWN WALL TO JUNCTION BOX AT 1'-6" TO PROVIDE POWER TO MODULAR FURNITURE. COORDINATE EXACT FURNITURE LOCATION WITH OWNER/ARCHITECT PRIOR TO ROUGH-IN. 5 RECEPTACLE TO BE INSTALLED IN TELEVISION RECESSED CHEIFBOX. 6 PROVIDE A 4" TALL PAD FOR TRANSFORMER MOUNTING. PAD DIMENSIONS TO BE 4" LARGER THAN TRANSFORMER FOOTPRINT IN ALL DIRECTIONS. 7 PROVIDE CEILING MOUNTED 14-30R FOR DATA RACK POWER. CIRCUIT SHALL BE FED BY (4) #10,#10 G. IN 3/4” CONDUIT. PROVIDE 2 POLE 30A BREAKER AT PANEL SPACES NOTED TO SUPPLY POWER. 8 PROVIDE CEILING MOUNTED CORD REEL WITH 45’ OF CABLE WITH DUPLEX RECEPTACLE MODULE. BASIS OF DESIGN HUBBELL HBLI45123GF220K. 9 PROVIDE 15A RATED TOGGLE SWITCH FOR ROOM EXAUST FAN CONTROL. 10 PROVIDE A MINIMUM OF A 6 GANG, ON GRADE RATED, RECESS ACCESS FLOORBOX. INSTALL TWO DUPLEX MODULES WITHIN FLOORBOX. ROUTE 1” CONDUIT ALONG SAME PATH AS DATA/AV CONDUIT THEN UP WALL AND BACK TO PANEL AS NOTED. PRIOR TO SLAB DEMOLITION FOR FLOORBOX AND CONDUITS CONTRACTOR SHALL X-RAY PROPOSE AREA TO ENSURE THAT EXISTING INFASTUCTURE WILL NOT BE DAMAGED. 11 PROVIDE POWER FOR OVERHEAD COILING DOORS. PROVIDE INTERCONNECTION BETWEEN DOOR CONTROLS AND DOOR MOTOR AS NOTED BY COILING DOOR MANUFACTURER. CIRCUITING SHALL BE BY (3) #10, #10 G IN 1” CONDUIT FOR COILING DOOR. COORDINATE COILING DOOR POWER (VOLTAGE, PHASE, AMPS) REQUIREMENTS PRIOR TO ROUGH IN, IF MANUFACTURER REQUIREMENTS DIFFER THAN SHOWN ON PLANS PROVIDE PLAN TO ACCOMIDATE TO ENGINEER FOR APPROVAL. # DESCRIPTION DATE GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. 03/10/23