Loading...
HomeMy WebLinkAboutM000_Symbols & AbbreviationsK-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUSCHINA T TTTTTTT10 9 86 3 7 2 6 6 6 1 1 1 1 1 1 1 1 5 9 9 1 4 1 1 1 1 3 3 3 11 12 12 ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS2 WEST MAIN STREET O: 317.810.1502CARMEL, IN 460322101 10-26-2022 BID DOCUMENTS MD101FIRST FLOORDEMOLITIONMECHANICAL PLANCLAY TOWNSHIPCENTER10701 North CollegeAvenueCarmel, INN 1/8" = 1'-0" FIRST FLOOR DEMOLITION MECHANICAL PLAN1 GENERAL NOTES A REFER TO SHEET M-000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. SHEET KEYNOTES 1 REMOVE DIFFUSER AND DUCT TO THIS POINT. PREPARE FOR NEW CONNECTION. 2 REMOVE DIFFUSER AND DUCT TO THIS POINT. PATCH WITH A DUCT ENDCAP. 3 REMOVE DIFFUSER AND DUCT BACK TO MAIN. PATCH DUCT. 4 REMOVED DUCT TO THIS POINT. PREPARE FOR NEW CONNECTION. 5 REMOVE DUCT TO THIS POINT. PATCH WITH A DUCT ENDCAP. 6 REMOVE DUCT AND GRILLE COMPLETE. 7 REMOVE EXISTING FAN AND DUCTWORK. PATCH EXTERIOR WALL PENETRATION. 8 REMOVE EXISTING FAN AND DUCTWORK. PATCH ROOF PENETRATION. 9 REMOVE THERMOSTAT AND WIRING. PRESERVE FOR RELOCATION. 10 REMOVE AND PRESERVE REHEAT COIL FOR RE-USE. 11 REMOVE PIPING AND SUPPORTS BACK TO COIL SHUTOFF VALVE AND CAP. 12 REMOVE PIPE TO THIS POINT AND PREPARE FOR NEW CONNECTION. # DESCRIPTION DATE 03/10/23 K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA K-3427HIGHLINETOILETSVITREOUS CHINA RAMP UP RAMP UP RAMP UP TTTTTTTTT GIS TECH OFFICE 118 GIS DIRECTOR OFFICE 117 SYSTEM ADMIN OFFICE 116 DIRECTOR OFFICE 115 ADMIN OFFICE 114 EXIST. COFFEE/ BREAK ? WORK SPACE 105 CONFERENCE 112 RECEPTION 113 EXIST. OPEN CONFERENCE ? Room 11 Room 12 Room 13 Room 14 EXIST. RESTROOM ? EXIST. RESTROOM ? Room 17 Room 18 Room 19 Room 28 Room 29 Room 30 NEW BREAK ROOM 111 OFFICE 110 OFFICE 109 OFFICE 108 WORK SPACE 102 Room 37 Room 38 Room 39 EXIST. TRUSTEE ? Room 41 Room 42 IT DATA ROOM 106 CORRIDOR 107 STAGING/ STORAGE 104 PAINT BOOTH 101 STAGING/ STORAGE 103 EXIST. TRAINING ? NEW GARAGE 100 EX 30/18 EX 14/10 EX 11/10 EX 11/8 EX 11/5 EX 11/9 EX 11/7 EX 11/5 EX 17/9 EX 8/4EX 8/4 EX 8/4EX 8/4 EX 8/4EX 8/4 EX 8/4 EX 8/7 EX 13/7 EX 13/9 EX 20/15 EX RHC-10 EX RHC-12 EX RHC-13 EX RHC-14 EX RHC-15 EX RHC-16 EX 8/4 RHC-11 12/6 SD1SD1 -100 SD1SD1 -80 SD1SD1 -85 1 SD1SD1 -100 SD1SD1 -100 SD1SD1 -100 SD1SD1 -100 SD1SD1 -100 SD1SD1 -100 SD1SD1 -100 SD1SD1 -100 SD1SD1 -180 SD1SD1 -80 SD1SD1 -80 6ø 6ø 8/8 RG2 RG2 RG2 SD1SD1 -150 RG2 SD1SD1 -100 RG2 SD2SD2 -220 SD1SD1 -175 SD1SD1 -170 SD1SD1 -170 RG2 RG2 RG2 8/8 SD1SD1 -200 SD1SD1 -200 SD1SD1 -200 SD1SD1 -200 SD1SD1 -200 SD1SD1 -200 SD1SD1 -200 SD1SD1 -200 RG1 RG1 EG1 6ø 6ø 6ø 6ø 6ø6ø 6ø6ø 6ø 6ø 8ø 8ø 14ø SG1SG1 -200 SG1SG1 -200 SG1SG1 -200 SG1SG1 -200 8ø8ø 8ø 8ø 10ø 14/10 26/10 8ø 8ø 14/10 10ø 8ø 8ø 14/10 12/18 RG3 RG2 SS-1 3/4" HHR 3/4" HHS TO RTU-1 EX 8/4 RG2 ø6 EX 20/18 EX 8/4 ø6 ø8 11/11 EX 11/4 1 1/4" HHR1 1/4" HHS2 2 2 ø8 ø8 10/5 8/6 3 10/10 RG4 24/18 4 5 6 7 8 8 8 8 8 8 8 8 8 8 88 8 8 7 7 9 10 ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS2 WEST MAIN STREET O: 317.810.1502CARMEL, IN 460322101 10-26-2022 BID DOCUMENTS M101FIRST FLOORMECHANICAL PLANCLAY TOWNSHIPCENTER10701 North CollegeAvenueCarmel, INN 1/8" = 1'-0" FIRST FLOOR MECHANICAL PLAN1 GENERAL NOTES A REFER TO SHEET M-000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. SHEET KEYNOTES 1 RELOCATED REHEAT COIL. 2 RELOCATED THERMOSTAT. 3 REROUTE PIPING TO AVOID THE NEW DATA ROOM. 4 MOUNT TRANSFER GRILLE ABOVE DOOR, CENTERED ON DOOR. 5 MOUNT RETURN GRILLE ABOVE DOOR, CENTERED ON DOOR. 6 MOUNT HIGH WALL SPLIT SYSTEM AS HIGH AS POSSIBLE. 7 CONNECT NEW PIPING TO EXISTING A THIS LOCATION. DUCTWORK GAUGE TO MATCH EXISTING. 8 CONNECT NEW DUCTWORK AT THIS LOCATION. DUCTWORK GAUGE TO MATCH EXISTING . 9 EXPOSED DUCTWORK BEYOND THIS POINT. 10 CONDENSATE DRAIN FOR DUCTLESS SPLIT SYSTEM. ROUTE THROUGH WALL AND TERMINATE 8-INCHES ABOVE FINISHED GRADE. # DESCRIPTION DATE 03/10/23 EF-1 RTU-1 SSCU-1 1 2 ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS2 WEST MAIN STREET O: 317.810.1502CARMEL, IN 460322101 10-26-2022 BID DOCUMENTS M102ROOFMECHANICAL PLANCLAY TOWNSHIPCENTER10701 North CollegeAvenueCarmel, INN 1/8" = 1'-0" ROOF MECHANICAL PLAN1 GENERAL NOTES A REFER TO SHEET M-000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. SHEET KEYNOTES 1 PACKAGED ROOFTOP HEATING/VOOLING UNIT IS TO BE INSTALLED A STANDARD 14-INCH ROOF CURB. 2 SPLIT SYSTEM CONDENSING UNIT TO BE INSTALLED ON CONDENSING UNIT PAD. # DESCRIPTION DATE 03/10/23 TYPICAL PACKAGED ROOFTOP UNIT PLUG VALVE UNION PIPE REDUCER PRESSURE REDUCING VALVE DIRT LEG PIPING BRANCH REFER TO PLANS FOR SIZE PIPE SUPPORT (TYPICAL) INSTALL GROMMET AT PENETRATION THRU CABINETRSRLEVAPORATOR COIL THERMAL EXPANSION VALVE SIGHTGLASS REFER TO MANUFACTURER FOR REFRIGERANT LINE SIZES AIR COOLED CONDENSING UNIT WITH FACTORY INSTALLED: 1. LIQUID LINE FILTER DRIER 2. SUCTION AND DISCHARGE LINE REFRIGERATION CHARGING CONNECTIONS FIELD BRAZED CONNECTIONS ISOLATION VALVE, TYP. CLEAN OUTPITCH DOWN TOWARD DRAIN CLEAN OUT DRAIN SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN FLOOR DRAIN AIR HANDLING UNIT DRAIN PAN 1"BAP = NEGATIVE PRESSURE (IN OF WATER) A = 1/2P + 2 IN B = 1 1/2P + 2 IN P PITCH DOWN TOWARD DRAIN CLEAN OUT DRAIN SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN FLOOR DRAIN AIR HANDLING UNIT DRAIN PAN 1"P = POSITIVE PRESSURE (IN OF WATER) A = P + 2 IN P CLEAN OUT AAA. METALLIC FLEXIBLE DUCT SHALL BE ATTACHED USING A MINIMUM OF THREE #8 SHEET METAL SCREWS EQUALLY SPACED AROUND THE DUCT'S CIRCUMFERENCE; DUCTS LARGER THAN 12"∅ SHALL HAVE A MINIMUM OF FIVE #8 SHEET METAL SCREWS. SCREWS SHALL BE LOCATED AT LEAST 1/2" FROM THE DUCT END. B. NON-METALLIC FLEXIBLE DUCT SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCT COLLAR EXCEEDS 12"∅, THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. C. INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY-FABRICATED DUCTS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND. D. FLEXIBLE DUCT SEALING SHALL BE A CLASS "B" SEAL FOR LOW PRESSURE SUPPLY. JOINING AND ATTACHING FLEXIBLE DUCT SPECIFICATION: RECTANGULAR SUPPLY DUCT SPIN-IN FITTING W/VOLUME DAMPER FLEX DUCT-MAXIMUM 6'-0" LENGTH AND NO MORE THAN ONE (1) 90° BEND. SQUARE TO ROUND FITTING CEILING SUPPLY DIFFUSER 90° METAL ELBOW TYPICAL AT ALL DIFFUSER CONNECTIONS UPBLAST CENTRIFUGAL EXHAUST FAN BIRDSCREEN NEMA 3R DISCONNECT FACTORY WIRED FROM MOTOR TO DISCONNECT THROUGH THE BREATHER TUBE LIQUID TIGHT FLEXIBLE CONDUIT (BY OTHERS) PREFABRICATED ROOF CURB ROOF AUTO BACKDRAFT DAMPER SEE PLANS FOR DUCT SIZE PROVIDE HOLE THRU ROOF SEE ARCH PLANS FOR ROOF CONSTRUCTION 4' LONG 8"TYPE "AT" GRILLE-SEE FLOOR PLANS FOR SIZE. INTERNALLY LINED DUCTWORK SEE FLOOR PLANS FOR DUCT SIZE.ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS2 WEST MAIN STREET O: 317.810.1502CARMEL, IN 460322101 10-26-2022 BID DOCUMENTS M501MECHANICALDETAILSCLAY TOWNSHIPCENTER10701 North CollegeAvenueCarmel, INNOT TO SCALE ROOFTOP UNIT GAS PIPING DETAIL1 NOT TO SCALE REFRIGERATION PIPING DETAIL3 NOT TO SCALE NEGATIVE PRESSURE CONDENSATE DRAIN TRAP DETAIL4 NOT TO SCALE POSITIVE PRESSURE CONDENSATE DRAIN TRAP DETAIL5 NOT TO SCALE TYPICAL SUPPLY DIFFUSER INSTALLATION7 NOT TO SCALE TYPICAL EXHAUST FAN (UPBLAST) DETAIL6 NOT TO SCALE AIR TRANSFER DUCT DETAIL2 # DESCRIPTION DATE 03/10/23