October 29, 2004
Kent Shaffer, Builder
2608 S. 875 E.
Zionsville, Indiana. 46077
re: WestClay #415
Kent:
Per our phone conversation, I inspected the 2"x 10" floor joists that were
drilled for the purpose of stringing wire in the Family Room.
The current code (R502.8) requires that no drilling shaH occur within 2"
of the bottom edge of the floor joists.
Please remove the wire and add a 2"x 4")1: 48" long the bottom edge of each joist
that does not meet the code. Center the 2"x 4" at each drilled h(11e.
. "
Attach the 2"x 4" with the appropliate adhesive and 10d X 3" minimum size nails
@6"o.c.
This letter replaces original letter, dated 10/28/04.