HomeMy WebLinkAbout04080055 Housewrap Info.
," . ~
-;
Superior moisture management Outstanding overall performance.
,=,~lnp!9P~
Patent Pending
Now there's a durable housewrap that works like no other to control moisture. New RainDroplM-
the advanced moisture-management housewrap that not only functions as an air and moisture
barrier but also has unique drainage channels built into the surface of the housewrap. When water
penetrates the siding, RainDrop's unique drainage channels provide space for the moisture to
drain to the base of the walls.. .and allow air movement between the exterior siding and the face of
the housewrap.
Drainage
Constructed wtth unique vertk:al fiber drainage
channels that allow water to drain to the base of
the wall system aoo air to move behind the
sidirg.
Easy Installation
. Translucen1so instaj~rscaneasify
seelhlOugh
. Green ",or rlidoces go..
. Great tear resistance
. UV-slable up 10 4 mooll<;
. Install with nails or staples
weight
(lbsJIIIIIIIM
w-B-1lI0A
. Grede.IIIT!ilOI5i !
RainDrop meeb the National Standard, UlJifoon, and International Buikllng Code requlnlmenlS for
ail barriers, moi$lure pmtection barrlenalld weather-resi~1Ne b:mien.
TnpriITemiIg ASIM 0 1117 2!il41
SIJenuUl(llltfn.MI1IIDI'
_8_ ASlM 0 m >fill
IIlIinumll
-\lop<< ASIM E 96 10
T_1lI1Il _A
iI&ml (I!i'E5IIl\RJl)
13
Iie_ ASIM E 84IIl
I1mDe Spnod 0
-1leveIopoI 15
""dilg
-1IIIBpiIr ASIM E 13D Pus
(miDimum IIr. @5IIDPoI6!im-" _A
, "" Ii'
Dimensipns/Packaging . . :'. ~ ~, " ''''. -<, ,
IlIIIISim
SquamFmltllloU
9'1100'
goO
. 9~15O. .
1350
23
40
4rxlll!r
20
RoIbIPalll
50
42'1.111!r
20
P&lIeIIITnltk
tllllPcint(.OlOirw;llesIl0mi'sj,f/lgIIl'Iml(.aZl1in!;l\a$lZl1111ilsl_
'\tathine DiltctionlCrm Direclion.
'TlIeaar\l,llllllricaIUillllelpnladandllllokerablll}SartJ'lOtilll.ndfljklrefl6clba.lard$""tul'lllldbylbi.!maltrial~MBr
acluolflltlConMIOflS.
WARMNG:lil:am,*an~~_II~maiDIi.Green&larlj~nr,OniluZbltnl~nclbe
I!I:llOStdlollmotCClltlignitionswrces.ThlllIIlEriaIml/presenlafrellaa'dl~UStlI_FiteanltxJikjj",cocIesslNllbe
--
Padi'l B~'din9l'fQclucbbelittQltIt infomlallOl'l andrecOlllm8flllaliofls nertinlo be ac(;Urale iIId f1Iliablt.llowa~er, tinco
~=~di:cl%~a:::: :m~ft, ':u1~oe::..~~ra:e ~8~:"=M~,~:~~r:~~~L~~,r ~~rr:~~on
"S TO TilE MERCH"m"BIUTV, FllltESS FOR PARTICULAR PURPOSE DR oTIIERW ISEWITIIRESPECTToTIlE
PRODUCTS REFERRED TO
;~~W~D is a regisltltd ~l!II'Iark 01 Pacti'! Bu~ding Produds. Q 2003 PaCti'l Building Producb, 10IGt
~NAHB
AJtCHI
~.\Trr",:,,1 c"">lCH III
OIL> "o~'..~" ,~,,~, ".l
.1:IS.ll1~:.til~'.lil'.lIS 1.1:1:1
III
II
ENERGY STAR-. ,
HOME SEALING
~
[ .
Pactiv Building Products
2100 RiverEdge Parkway
Suite 175
Atlanta, Georgia 30328
Toll Free: (800) 241-4402
Web Site: www.green-guard.com
G
Green
Guard"
Product Guide Specification
Specifier Notes: This product guide specification is written according to the Construction Specifications
Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, contained in the CSI
Manual of Practice.
The section must be carefUlly reviewed and edited by the Architect to meet the requirements of the project and
local building code. Coordinate this section with other specification sections and the drawings.
Delete all "Specifier Notes" when editing this section.
SECTION 07270
AIR BARRIERS
I
Specifier Notes: This section covers Pactiv Building Products GreenGuarri" "RainDrop" Housewrap. Housewrdp
is a weather-resistive barrier that provides protection against air infiltration and bulk moisture penetration inl
exterior wall applications involving siding, brick, stone, masonry, stucco, and concrete systems. Housewrap can
be used for added weather protection in exterior wall systems that incorporate wood and insulating sheathings.
Consult Pactiv Building Products for assistance in editing this section for the specific application.
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Housewrap to provide protection against air infiltration and management of bulk moisture that penetrates
exterior walls.
1.2 RELATED SECTIONS
Specifier Notes: Edit the following list of related sections as required for the project. List other sections with
work directly related to this section.
A. Section 07100 - Dampproofing and Waterproofing.
B. Section 07210 - Building Insulation.
C. Section 07260 - Vapor Retarders.
1.3 REFERENCES
Specifier Notes: List standards referenced in this section, complete with designations and titles. This article
does not require compliance with standards, but is merely a listing of those used.
07270 - I
:0 PACTIV
........... BuildirigProducts
r
A. ASTM 0 751 - Standard Test Methods for Coated Fabrics.
B. ASTM 0 779 - Standard Test Method for Water Resistance of Paper, Paperboard, and Other
Sheet Materials by the Dry Indicator Method.
C. ASTM D 882 - Standard Test Method for Tensile Properties of Thin Plastic Sheeting.
D. ASTM D 1117 - Standard Guide for Evaluating Nonwoven Fabrics.
E. ASTM 0 1777 - Standard Test Method for Thickness of Textile Materials.
F. ASTM D 3776 - Standard Test Method for Mass Per Unit Area (Weight) of Fabric.
G. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
H. ASTM E 96 - Standard Test Method for Water Vapor Transmission of Materials.
1.4 SUBMITTALS
A. Comply with Section 01330 - Submittal Procedures.
B. Product Data: Submit manufacturer's product data, including installation instructions.
C. Samples: Submit manufacturer's samples of house wrap.
D. Manufacturer's Certification: Submit manufacturer's certification that materials comply with specified
requirements and code compliance and are suitable for intended application.
1.5 QUALITY ASSURANCE
A. Code Compliance:
I. GreenGuard RainDrop Housewrap meets the weather-resistive/moisture protection barrier requirements
of the National, Standard, Uniform and International Building Codes.
2. HUD/FHA UU-B-790A, Equivalent to Grade D, Type 15.
3. ASTM D 226, Type I (Specification for Felt Building/Roofing Paper).
1.6 DELIVERY, STORAGE, AND HANDLING
A. Delivery: Deliver materials to site in manufacturer's original, unopened containers and packaging,
with labels clearly identifying product name and manufacturer.
B. Storage: Store materials in clean, dry area in accordance with manufacturer's instructions. Do not expose
to flame or other ignition sources.
C. Handling: Protect materials from damage during handling and installation.
1.7 ENVIRONMENTAL REQUIREMENTS
A. Do not install materials over surfaces that are wet, frozen, or that contain frost. Wet surfaces
should be allowed to dry before installing the siding material.
PART 2 PRODUcrs
2.1 MANUFACTURER
A. Pactiv Building Products, 2100 RiverEdge Parkway, Suite 175, Atlanta, Georgia 30328. Toll Free (800)
241-4402. Pbone (678) 589-7309 Fax (678) 589-7330. Web Site www.green-guard.com.
07270 - 2
-=-
Q ~~~uct;IV
;
2.2 MATERIALS
Specifier Notes: SpecifY the following housewrap Add weather-resistive barrier to the housewrap description
in exterior wall systems that incorporate wood and insulating sheathings. Consult Pactiv Building Products for
additional information.
A. Housewrap: GreenGuard RainDrop.
I. Description: Exterior wall air infiltration barrier and bulk moisture penetration barrier. [Weather-
resistive Barrier.]
2. Material: GreenGuard RainDrop consists of a polyolefin coated cross-woven polyolefin scrim with
filaments that form channels to allow for drainage of bulk moisture. RainDrop is designed to allow
moisture vapor to escape.
3. Thickness, ASTM D 1777: 0.008 inch (0.2 mm).
4. Average Weight, ASTM D 3776: 16.0 pounds per 1,000 square feet (78.2 glm').
5. Water Resistance, ASTM D 779: 60 minutes.
6. Water Vapor Transmission Rate, ASTM E 96, Procedure A: 10.0 perms.
7. Water Vapor Permeance, ASTM E 96, Procedure A: 73 g/m'/24 hours.
8. Tensile Strength, ASTM D 882:
a. Machine Direction: 56 pounds per inch (10.0 N/mm).
b. Cross Direction: 30 pounds per inch (5.3 N/mm).
9. Burst Strength, ASTM D 751: 155 psi (1068.7 kPa).
10. Trapezoid Tearing Strength, ASTM D 1117:
a. Machine Direction: 25 pounds per inch (4.4 N/mm).
b. Cross Direction: 41 pounds per inch (7.3 N/mm).
II. Fire Characteristics, Flame Spread/Smoke Developed, ASTM E 84: Class A - 0115.
12. UV Resistance: 4 months.
2.3 ACCESSORIES
A. Fasteners: Attach Green Guard RainDrop Housewrap using common roofing nails, plastic cap nails, or
staples having a minimum I-inch (25 mm) crown. If smaller crown staples are used, then more fasteners
must be used. Fasteners must penetrate the underlying substrate or framing a minimum of 1/2 inch (13 mm).
B. Housewrap Tape: GreenGuard Contractor Tape (Enhanced Adhesion) or an equivalent.
PART 3 EXECUTION
3.1 EXAMINATION
A. Examine areas to receive housewrap. Notiry Architect of conditions that would adversely affect
installation. Do not proceed with installation until unsatisfactory conditions are corrected.
3.2 SURFACE PREPARATION
A. Ensure surfaces are clean, dry, and flat. Ensure surfaces are free of honeycombs, fins, and foreign
material that could damage housewrap.
3.3 INSTALLATION
Note I:
Note 2:
Do not use housewrap as a roofing paper or as a vapor retarder.
Contact Pactiv Building Products jOr special installation details, such as housewrap and flashing
integration, penetrations. and sealing techniques.
07270 - 3
e
'='
PACTIV
Buikli1gProdlKts
; <
.
I. Install housewrap over structural sheathing board or insulation board.
2. Begin by aligning the bottom edge of the roll with the base of the wall, approximately 2 feet (610 mm) from
a corner, with the print side facing out and the black strands ronnin!! verticallv down the wall. Fold
several inches (mm) of material under itself and fasten securely to a structural sheathing or through insulation
board to an underlying framing member.
3. Unroll the housewrap with the printed side out, wrapping the entire building, including door and window
openings. Common roofing nails, plastic cap nails, or staples with a minimum I inch (25 mm) crown may
be used for attachment of the housewrap to structural sheathing or through insulation to framing members. If
smaller crown staples are used, then more fasteners must be used. When installing housewrap over non-
structural sheathing such as insulation board, fas1eners should penetrate the underlying stud a minimum of
1/2 inch (13 mm). Fasteners should be spaced every 12 inches (305 mm) along every other stud location and
every 6 inches (152 mrn) around door and window openings.
4. For best results, a modified "I" pattern should be made through the housewrap at window openings. Fold
excess material inside the rough opening and fasten securely through all layers to a framing member. If
doors and windows are already in place when installing the housewrap, trim as close to them as possible and
tape housewrap edges. Use Pactiv Contractor Tape (Enhanced Adhesion) or equivalent tape to seal housewrap
seams and around openings, window flanges, door jambs, sill plates, pipes, ducts, etc. Use of window
flashing materials is encouraged. Refer to the Pactiv Building Products Housewrap Installation Guide for
detailed information.
5. When the end ofa roll is reached, fold the edge of the housewrap under itself and attach to the structural
sheathing or through insulation board to an underlying framing member. Vertical and horizontal seams must
be overlapped a minimum of6 inches (152 mm) unless other wise specified for a particular application.
Upper courses of housewrap must overlap lower courses (in water shedding fashion). All vertical and
horizontal seams must be taped using Pactiv Contractor Tape (Enhanced Adhesion) or equivalent tape.
3.4 PROTECTION
A. Protect installed housewrap from damage until covered by exterior wall material.
END OF SECTION
07270 - 5
as.RD
3103
~
e PACTIV
'=" lkaldingProducts