HomeMy WebLinkAboutA-F201 - FIRE SUPPRESSION PLANSM M M M M PROVIDE ALTERNATE PRICING FOR ARCHIVE SCOPE Foyer Entry Gallery Water UP Mercantile Gallery Bookstore UP ADA Restroom Janitor's Closet Restroom Archive M M M M M M M MDN White Box Space Future Gallery UP DN UP Mech. ADA Restroom Restroom Break Room Archive PROVIDE ALTERNATE PRICING FOR ARCHIVE SCOPE M M M M M M M M M M M M M M M Lift Depot Elec.Mech. Restroom UP UP +828.10 +828.10 +830.10 C D E.3 K E J 4 2 5 6 G H D.2 F A G.8 H.8 J.8 C.2A.9A.5A.1 1 3 H.2D.8 4 5 4 5 9 FP CONTROLLER JP CONTROLLER FP-1 JP-1 12 FDC TEST HEADERBID PACKAGE 2 BID PACKAGE 1 C D E.3 K E J 4 2 5 6 G H D.2 F A G.8 H.8 J.8 C.2A.9A.5A.1 1 3 H.2D.8 4 5 4 5 6 FM-200 TANK FM-200 CONTROLLER 9BID PACKAGE 2 BID PACKAGE 1 C D E.3 K E J 4 2 5 6 G H D.2 F A G.8 H.8 J.8 C.2A.9A.5A.1 1 3 H.2D.8 4 5 4 5 6 BID PACKAGE 2 BID PACKAGE 1 K L 4 2 5 6 M NJ.8 1 3 10 11 P BID PACKAGE 2 ARCHITECTOWNERCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS1344 S RANGELINE RD SUITE 202 CARMEL, IN 46032317-344-8044Carmel Clay History MuseumDepot Renovation and Archives Building03/02/202320081 March 2, 2023 Bid Documents F201FIRE SUPPRESSIONPLANS211 1st St SWCarmel, IN 460231/8" = 1'-0" FIRST FLOOR FIRE SUPPRESSION PLAN1 1/8" = 1'-0" SECOND FLOOR FIRE SUPPRESSION PLAN2 1/8" = 1'-0" THIRD FLOOR FIRE SUPPRESSION PLAN3 GENERAL NOTES A FIRE PROTECTION CONTRACTOR SHALL DESIGN A COMPLETE SPRINKLER SYSTEM ACCORDING TO THE CRITERIA OUTLINED ON THE DRAWINGS AND NFPA13, 13R, 14, 20, 24. AND INDIANA FIRE CODE. B REFER TO SHEET A-P000 FOR FIRE PROTECTION GENERAL NOTES. C PROVIDE CHROME PLATED SEMI-RECESSED SPRINKLER HEADS IN AREAS WITH FINISHED CEILINGS (I.E. GYP BOARD OR ACOUSTICAL CEILING TILE). D PROVIDE BRASS UPRIGHT SPRINKLER HEADS IN AREAS WITH NO CEILINGS (EXPOSED TO STRUCTURE). E PROVIDE CHROME PLATED SIDEWALL SPRINKLER HEADS IN AREAS WHERE IT IS IMPRACTICAL TO PROVIDE CEILING MOUNTED SPRINKLERS. F REFER TO PLAN NOTE 9 FOR ALTERNATE BID SCOPE FOR ARCHIVE SPACE. ALTERNATE BID FOR CLEAN AGENT FM-200 SYSTEM TO INCLUDE THE FOLLOWING PROVISIONS: FULLY SEAL AND FIRE CAULK ALL PENETRATIONS IN/OUT OF ROOM, ALL DRYWALL JOINS SHOULD BE CAULKED AT JOINTS OF WALLS, FLOOR, AND STRUCTURE ABOVE, SEALS ON DOOR JAMS AND THRESHOLDS, FLOOR DRAINS IN ARCHIVES TO HAVE TRAP PRIMERS, AND MOTORIZED DAMPERS ARE REQUIRED IN SUPPLY & EXHAUST DUCTWORK ON EACH FLOOR FOR SHUTTING OFF AIRFLOW (4 TOTAL). SHEET KEYNOTES 1 6" F DOWN THROUGH SLAB. 2 4" F TO FDC. 3 REFER TO CIVIL ENGINEERING DRAWINGS FOR CONTINUATION. 4 STANDPIPE RISER. 5 HOSE VALVE, CAP & CHAIN AT 42" ABOVE INTERMEDIATE STAIR LANDING. 6 FLOOR CONTROL VALVE, FLOW SWITCH, TEST, AND DRAIN. 7 HOUSEKEEPING PAD. REFER TO STRUCTURAL DRAWINGS. 8 PROVIDE DRAIN PAN ABOVE FP CONTROLLER AND PUMP TO PROTECT FROM ANY WATER LEAKS. 9 BASE BID FOR ARCHIVE TO BE WET FIRE SPRINKLER SYSTEM. ALTERNATE BID FOR ARCHIVE TO BE PROTECTED BY A COMPLETE WATERLESS CLEAN AGENT FIRE SUPPRESSION SYSTEM CONSISTING OF CLEAN AGENT TANK(S), CONTROL PANEL, BATTERY BACKUP, AUXILIARY ALARM FOR CONNECTION TO BAS, VENTILATION/PURGING SYSTEM, SMOKE/HEAT DETECTORS, AUDIBLE/VISUAL ALARMS & STROBES, BOTTLE SOLENOID VALVES, PRESSURE MONITORS OF BOTTLES, ABORT SWITCH, HOLD OFF SWITCH, REMOTE STATUS SWITCH, SIGNAGE, PIPING, NOZZLES, ETC. BY FIRE PROTECTION CONTRACTOR. DETECTORS, WIRING, WIRING TO FIRE ALARM PANEL BY THE FIRE ALARM CONTRACTOR. 10 DEPOT WILL NOT HAVE FIRE SUPPRESSION. FIRE PROTECTION CONTRACTOR TO PROVIDE A ROW OF SPRINKLER HEADS AT 6 FT MAXIMUM SPACING IN CEILING OF CONNECTOR ADJACENT TO EXISTING WALL OF DEPOT. 11 CONNECTOR TO HAVE FIRE SUPPRESSION FROM MAIN BUILDING. 12 TO FIRST FLOOR SPRINKLERS. 1/8" = 1'-0" FIRST FLOOR FIRE SUPPRESSION PLAN DEPOT4 #DESCRIPTION DATE