HomeMy WebLinkAbout06060026 Misc. ;:; .. . Outside Air Kit Installation Instructions Model: AK~MST . cC~US LISTED The Outside Air Kit can be Instaiied to lI1e fOllowing CFM Specially Home Products Series fireplacas to bring combustion air to the fire chamber. 36/428AY CR36R1L MSF36/42 STR33/36/42 36/42CV CV36 MST36 TF36/42 36/421S CVR36/42 ODSHR42 TL36/42 36/42ST IS36 SC361421A TSH36/42152 BAY36 LST SH36/42 TST42 BC36/42 MR42A SHR36/42/N48/52 BR36142 MRC42A SR36/421A WMC36/42 C36R1L WMC36/421P The air that is drawn Inlo the nre chamber from outside the home or unheated area helps relieve the pressure In the home. Check Contents of Shipping Carton campara contents of carton In Figure 1 With. actuel - - parts received. If any parts are missing, or damaged, contact Your dealer before starting installation. NOTE: Four (4) inch Class 1 air duct, material or metal duct (not suppliad) may be used with AK-MST. (For Installation in Naw York State. only alumi- num, noncombustible flexible or type no" metal duetlng Is permissible.) Installation Precautions The duct termination shOUld be located so It Is exposed to an out-of-<loors opening at least 100 square inches. II tha duct termination must be localed in a crewl space or basement. be sure the termina- tion area has 100 square inches of ventilation open.. ing to outside air. The duct termination must be located So it does not compete for air flow with exhaust fans, gas vent hoods or other aIr consuming devices or appliances. It must not be obstructed by rafters, insulation materials Of other obstructions. The less restrictIve the air supply, the better the AK-MST will perform. It is a good practice to protect your hands and eyas during InstallatiOn by wearing work gloves and safety glassas. p. 001 Inlet Collar RaIn Cap Fig. 1 Carton contents. CAUTION: Do noflnstall tenminalion info a garage or other area that could contain flammable liquids or fumes, or into an attic space. Installation Instructions Determine lI1e location 01 the firaplace as described In the fireplace Installation Manual. Than plan locetion of the duct termination and the route of the duct rUn between tha fireplaca and the duct terminetion. Duct run must ba limited to a maximum distance 0140 leet from the fireplace pipe collar to duct terminalion. This will provida tfia least restriCtion to air flow. No more than four (4) 90. elbows can be used. Duct run * may be horizont",!.,y,e.rtical, inclined or any comb.i,,~.-.. tlD. n 01 tJ}~P.c8;;;Y:..WfJ.~ }.) iijil.i1l;. iWfiJtlKm.t!ir,1W.::,\~j.t J!1~.. ilq~rije..:;;)." !?l!~;~~~~~~:~~~:;C~~~~~~1~1~~~:ir~- Kit. 1. Remove and discard the outsida air knockout (or cover plata) locatad at the center left side Or bottom right side of the fireplace. Use cara not to rub ageinst the sharp edges of this opening to avoid cuts. 2. Attach the Inlet collar with four (4) #10 screws to the side or bottom of the fireplace. Slide the duct over the collar and attach the duct to the collar USing the plastic tie straps or three (3) screws (screws not provided). Continue attaching the dueling together using three (3) screws et each joint until you have installed sufficient duct to arrive at your duct termination location. 3. At the termination end, Install the duct termination. This should be installed Irom the outside of the home. Cut a hole in the desired location approxi- mately 411" in diameter, C@/k around the hole, and slide Ihe termination through the opening Irom outside the home. The ierrninationlrain cap should btl' ~QuIKetl i::lJuund h:;j fJtlIdlllt:ller [Q Bssure e tIght. seal. The rain cap opening should be positioned downward. (Fig. 3) . 7412:280 3/04 Rov.2 Extend panel sheathing (Interior and exterIOr) full height. 2. Double-2x4 Bloc~ng at sheathing panel JOint. Nail together With 3-1 Gd nails. ~ III ~ '" Header er Plan ID ~ Double-2x4 Blocking at mld-helqht and top of door opening. Nail together v.1th 3-1 Gd nails. 4 Structural Brace sheathing by Ludlow Coated Products on extenor surface.~' gypsum board on Intenor surface. Attach to framing and bloc~ng per notes. +I ~ NOTES: @ I. Attach Structural Brace sheathlnq to framing and bloc~ng v.1th 7/1 G' crown staples v.1th 1 1/4' leq (I G qage) spaced at 3' o.c. at panel edges and G' o.c. at Intermediate supports. Attach drywall to framing and blocking v.1th IG x I 1/4'Iong screws (f ype W or S Drywall Screws) at 4' o.c. at panel edges and I G' o.c. at Intermedlilte supports. @ 2. Shear Panel as shown IS re<iulred at both garage leqs (two shear panels per home). @ 3. NI constnJctlon not addressed by thiS detail shall stncty comp~ v.1th local and current bUilding codes. I'-<ll/Z' (MN) (1) <V ~>>." """" . IG'-3' Opening Width I~'-<l'! Overall Width Garage Slab Final Grade Garage Leg - Elevation View Scale: 1/2' - 1'-0' GARAGE LEG REINFORCEMENT FOR MODELS IN THE INDIANAPOLIS METROPOLITAN AREA Estridge Companies Cannel, Indiana @ CopYrltjht 200(; by Schwarz Entjlneenntj Group John D. Schwarz, r.E. Schwarz En':jlneerln':j Group 13023 Lockburn rlace, Fishers, Indiana 4G038 317.579.8927