Loading...
HomeMy WebLinkAboutC720 - Site Utility Details - SU2.2COPYRIGHT 2022 BY FANNING/HOWEY ASSOCIATES, INC.WWW.FHAI.COMARCHITECTPROJECT NUMBER: 222063.00CARMEL HIGHSCHOOLGREYHOUNDACTIVITY CENTERCARMEL CLAY SCHOOLS520 E MAIN STREETCARMEL, IN 46032PROJECT ISSUE DATE: 12.01.2022CONSTRUCTION DOCUMENTSDRAWN BY: ARS317.848.0966350 E NEW YORK ST #300, INDIANAPOLIS, IN 46204REV.NO.DESCRIPTIONDATECONSULTANTPROJECT MANAGER: PMR19700317No.SU2.2SITE UTILITY DETAILSSTORM STRUCTURE TABLESTR.NO.101102103104105106107108109110111112113114115116117117A118119120121122123124125STRUCTUREInlet Type "A"Inlet Type "A"Type "C" ManholeType "C" ManholeType "C" ManholeCleanoutCleanoutCleanoutCleanoutCleanoutType "C" ManholeType "C" ManholeType "C" ManholeType "C" ManholeInlet Type "M"Type "C" ManholeInlet Type "A"Inlet Type "A"Type "K" ManholeType "J" ManholeType "J" ManholeType "J" ManholeAqua Swirl XC-11Type "J" ManholeType "J" ManholeEnd SectionSTRUCTUREDETAILREFERENCESHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.1SHEET SU2.2SHEET SU2.1SHEET SU2.1UndefinedCASTING TYPER-4342R-4342R-1772R-1772R-1772JR SMITH 4253JR SMITH 4253JR SMITH 4253JR SMITH 4253JR SMITH 4253R-1772R-4342R-1772R-3472R-3455-CR-3472R-4342R-4342R-1772R-4342R-1772R-1772PER MAN.R-1772R-1772N/ARIM816.50816.50816.72817.63817.72817.80817.35817.35817.35817.51816.35816.96816.40810.24809.72810.20811.97811.05811.49810.52811.13809.96809.95807.59805.60-1.00INCOMING PIPE DATA(DIRECTION) [FROM STR]12" HDPE Pipe 812.45 (E) [101]12" HDPE Pipe 812.08 (E) [102]15" HDPE Pipe 811.08 (N) [103]18" HDPE Pipe 809.58 (N) [104]12" HDPE Pipe 813.39 (N) [106]15" HDPE Pipe 813.10 (N) [107]15" HDPE Pipe 812.20 (N) [108]18" HDPE Pipe 811.65 (N) [109]18" RCP 808.30 (W) [105]18" HDPE Pipe 811.50 (N) [110]12" RCP 808.10 (N) []15" RCP 807.59 (NE) [112]15" RCP 806.27 (N) [113]15" RCP 805.04 (W) [114]24" RCP 804.58 (W) [115]12" RCP 807.76 (NW) [117]18" RCP 806.04 (W) [111]24" RCP 804.34 (SW) [116]12" RCP 807.54 (NW) [117A]30" RCP 803.73 (W) [118]30" RCP 802.90 (W) [119]30" RCP 802.55 (NW) [120]30" RCP 802.36 (NW) [121]30" RCP 801.45 (NW) [122]30" RCP 799.95 (N) [123]30" RCP 799.54 (NW) [124]OUTGOING PIPE DATA(DIRECTION) [TO STR]12" HDPE Pipe 812.78 (W) [102]12" HDPE Pipe 812.35 (W) [103]15" HDPE Pipe 811.98 (S) [104]18" HDPE Pipe 810.98 (S) [105]18" RCP 809.48 (E) [111]12" HDPE Pipe 813.61 (S) [107]15" HDPE Pipe 813.39 (S) [108]15" HDPE Pipe 813.10 (S) [109]18" HDPE Pipe 812.20 (S) [110]18" HDPE Pipe 811.65 (S) [111]18" RCP 808.20 (E) [118]15" RCP 807.73 (SW) [113]15" RCP 806.49 (S) [114]15" RCP 805.87 (E) [115]24" RCP 804.94 (E) [116]24" RCP 804.48 (NE) [118]12" RCP 808.28 (SE) [117A]12" RCP 807.66 (SE) [118]30" RCP 803.94 (E) [119]30" RCP 803.63 (E) [120]30" RCP 802.80 (SE) [121]30" RCP 802.45 (SE) [122]30" RCP 802.36 (SE) [123]30" RCP 801.35 (S) [124]30" RCP 799.85 (SE) [125]OUTGOINGPIPE L.F.105'83'180'281'236'54'76'159'114'38'108'48'73'165'183'67'86'20'71'242'83'25'262'400'88'OUTGOINGPIPE SIZE12"12"16"18"18"12"16"16"18"18"18"15"15"15"24"24"12"12"30"30"30"30"30"30"30"OUTGOINGGRADE0.32%0.32%0.50%0.50%0.50%0.40%0.38%0.57%0.48%0.40%2.00%0.30%0.30%0.50%0.20%0.20%0.60%0.60%0.30%0.30%0.30%0.35%0.35%0.35%0.35%CONNECT TOSTR.102103104105111107108109110111118113114115116118117A118119120121122123124125REMARKS-----HDPE Wye Fitting - 8"x12"x12"HDPE Wye Fitting - 8"x12"x15"HDPE Wye Fitting - 8"x15"x15"HDPE Wye Fitting - 8"x18"x18"HDPE Wye Fitting - 8"x18"x18"---------------NOT IN CONTRACTNOT IN CONTRACTADDENDUM #11-6-20231STORM WATER QUALITY BMP STRUCTURE (ST-122)2REGULATORY REVIEW1-18-202336-15-2023PR00646-16-2023PR007 & TAC RESPONSE