Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E101 Electrical Floor Plan
Engineer: I 11 ----- --- nFFIr _P COOLER 115 � o WOMENS 112 LA1 LA2 LB LC LID LE Zj� "DI I INK RAPK1q IRFAM■ IRV BAR VEST 00 114 WAITING 101 BAR DINING 113 FH O I I I I I I nAF=r -W ELECTRICAL FLOOR PLAN � IT F E DINING 102 FCU-6 PRIVATE 4 DINING -..-) 103 OUTDOOR nimimr; GENERAL NOTES A. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. B. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. C. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. D. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. E. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. F. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. O SHEET KEYNOTES 1. PROVIDE POWER TO FAN COIL UNIT FROM PANEL LC. FURNISH AND INSTALL NEW 50A 208V/3P BREAKER IN PANEL. MINIMUM WIRE SIZE (3) #8 W/ #10 GND IN 3/4"C. DISCONNECT SWITCH TO BE 60A/3P NEMA 1. 2. PROVIDE POWER TO FAN COIL UNIT FROM PANEL LC. FURNISH AND INSTALL NEW 60A 208V/3P BREAKER IN PANEL. MINIMUM WIRE SIZE (3) #6 W/ #10 GND IN 1"C. DISCONNECT SWITCH TO BE 60A/3P NEMA 1. 3. PROVIDE POWER TO FAN COIL UNIT FROM PANEL LA2. FURNISH AND INSTALL NEW 60A 208V/3P BREAKER IN PANEL. MINIMUM WIRE SIZE (3) #6 W/ #10 GND IN 1 "C. DISCONNECT SWITCH TO BE 60A/3P NEMA 1. 4. PROVIDE POWER TO FAN COIL UNIT FROM PANEL LA1. FURNISH AND INSTALL NEW 30A 208V/3P BREAKER IN PANEL. MINIMUM WIRE SIZE (3) #10 W/ #10 GND IN 3/4"C. DISCONNECT SWITCH TO BE 30A/3P NEMA 1. RE —CONFIGURE BREAKERS IN PANEL AS REQUIRED TO CREATE SPACE FOR NEW 3—POLE BREAKER. 5• FURNISH AND INSTALL 225A/3P BREAKER IN SPACE IN MDP. BREAKER TO POWER NEW PANEL LE. SEE PLAN NOTES 1 AND 2 ON E103 FOR ADDITIONAL WORK IN MDP. 6• FURNISH AND INSTALL NEW 42 CIRCUIT, 225A, 208V, 3P/4W PANELBOARD. PANELBOARD TO BE FILLED OUT WITH 20A SPARES FOR FUTURE USE. FEEDER SIZE TO BE 4#4/0 W/ #4 GND IN 2-1/2" C. FEED PANELBOARD FROM NEW BREAKER INSTALLED IN MDP. UACQUIS IN CONSULTING ENGINEERS Z 9229 DELEGATES ROW, SUITE 550 INDIANAPOLIS, IN 46240 317.706.2075 WWW.LACQUIS.COM L'Acquis Project No: 12056 By: Developer: P E D C O R ? P aeWA5�x DEVELOPMENT CO. Project: COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, 2010, 2011 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA Issue Date Drawn By Checked By 0812712021 MAS L Revisions: STATE RELEASE SET: 03/26/2012 fA COOLER Q ADDENDUM #1: 04/06/2012 105 Q CONSTRUCTION SET: 04/20/2012 QSTATE RELEASE ADDENDUM: 06/20/2012 APR#: 06/28/2012 ASYSTEM UPGRADE: 08/27/2021 Project Number: Sheet Title: Electrical Floor Plan Sheet Number: E=1 01