HomeMy WebLinkAboutA101_First Floor and Roof PlanUP
Dining
Seating
RR
RR
Kitchen
Walk-in
Walk-in
Dining
101
Back of House
102
A2011A2012
--
A202 1
2
A20221' - 3" 37' - 7''58' - 10 1/8"3' - 1 5/8"18' - 1"5' - 8"31' - 11 1/8" 58' - 3''
48' - 6 1/2"8' - 0" 54' - 3''17' - 0"71' - 3 3/4"37' - 1 5/8"33' - 8"14' - 0"0' - 3 1/2"22' - 4 5/8"4' - 6" 5' - 0" 4' - 6"
17' - 9"
16' - 6"
6' - 4"10' - 2"
10' - 3 1/4"
01
02
EW1
EW11' - 1 1/4" 12' - 0" 1' - 3 1/2" 12' - 0" 1' - 3 1/2" 12' - 0" 1' - 3 1/2" 12' - 0" 1' - 3 1/4"
102
103
Restroom
103
04
05
104
105
2
A400
1
A400
W1W1A400
3
EW1
EW1 EW1EXISTING
BUILDING
W1
EW1
EW111' - 3 5/8"11' - 4"10' - 10 1/4"24' - 0"3' - 6 1/4"
EW2
EW3
6' - 0"6' - 0"6' - 0"6' - 0"-
---
01
300
-
---
03
300
-
---
02
300
-
---
-
-
09
3
400
16
18
17
03
15EW4EW4EW4114
9' - 10 5/8"13' - 0 1/2"14' - 2 7/8"
30' - 3 1/8"
20' - 6 3/8"8' - 0" 1' - 8 3/4"3' - 0 7/8"18' - 0"10' - 0"
-
---
100
100
100
100
General Notes
1. THE GENERAL CONTRACTOR SHALL VERIFY
ALL CONDITIONS AT THE JOBSITE. NOTIFY
ARCHITECT OF ANY DEVIATIONS FROM THOSE
CONDITIONS AS THEY ARE NOTED ON THE
DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL
COORDINATE AND SCHEDULE ALL WORK WITH
THE OWNER.
3. THE GENERAL CONTRACTOR IS RESPONSIBLE
FOR COMPLIANCE WITH ALL STATE AND
LOCAL BUILDING CODES AND GOVERNMENT
REGULATORY AGENCIES.
4. THE GENERAL CONTRACTOR IS TO SUBMIT
SHOP DRAWINGS-PROJECT DATA AND
SAMPLES TO OWNER/ARCHITECT FOR
APPROVAL PRIOR TO FABRICATION OF ALL
MILLWORK AND WALL FINISHES.
5. DO NOT SCALE ANY DRAWING. ANY
DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECT IF NOT NOTED ON THE DRAWINGS.
REFER ALL QUESTIONS TO THE ARCHITECT
OR ENGINEER ON RECORD.
6. ALL DIMENSIONS ARE TO C.L. OF DEMISING
WALL OF UNITS AND FACE OF FRAMING.
7. THE GENERAL CONTRACTOR SHALL KEEP
ONE SET OF PLANS AT THE JOBSITE FOR THE
SPECIFIC PURPOSE OF RECORDING ACTUAL
CONSTRUCTION CONDITIONS. SUCH PROJECT
RECORD-DOCUMENTS SHALL BE PROVIDED
TO THE OWNER UPON COMPLETION OF THE
PROJECT.
8. THE GENERAL CONTRACTOR SHALL VERIFY
SIZE, LOCATION, AND CHARACTERISTICS OF
ALL WORKS AND EQUIPMENT SUPPLIED BY
THE OWNER OR OTHERS WITH THE
MANUFACTURER OR SUPPLIER PRIOR TO THE
START OF THE WORK.
9. THE GENERAL CONTRACTOR SHALL SEE THAT
ALL SUBCONTRACTORS RECEIVE COMPLETE
WORKING DRAWINGS AND ASSUME FULL
RESPONSIBILITY FOR COORDINATION OF
WORK.
Plan Key Notes
01 EGDGE OF SLAB
02 6'' CONDUIT, SEE PLUMBING
03
04 METAL RAILING
05 SMART PERGOLA BY OTHER
06 PREFINISHED VINLY FENCE
07 FLOOR DRAIN; SEE PLUMBING EQUIPMENT
08 MECHANICAL EQUIPMENT; SEE MECHANICAL
09 STUD BELOW
10 APPLY FRP FULL HEIGH
11 INSTALL NON ABSORTIVE WALL FINISH
TO EXTENTS SHOWN
ISTALL UP TO 6'' AFF.
12 ELECTRIC HAND DRYERS; SEE ELECTRICAL
13 JANITOR SINK; SEE PLUMBING
14 STAINLESS STELL GRAB BARS.
15 SEE CIVIL FOR WALK DETAILS.
16 GATE WITH LOCKING HARDWARE
MATCH VINYL FENCE STYLE+ FINISH.
1617 FIRE EXINGUISHER.
1618 20'' x 40'' ATTIC ACCESS PANEL
4'' STEP
1619 STANDING METAL SEAM SCREEN- COLOR
TO MATCH EXISTING ROOF
A2011A2012
A202 1
2
A202 6:126:126:121/4:1204
8:128:12 8:128:1219
19
-
---
-
---
-
---
03
300
01
300
02
300
08
DS GUTTER DS
RIDGE VENT
CONTRACTOR TO
CONFIRM ADEQUATE
FLASHING AT EXISTING BUILDING
05
DS
GUTTER
DS
GUTTER
DS
GUTTER
09
-
---
PATCH+ REPAIR
EXISTING ROOF AS NEEDED
FOR INSTALLATION
OF RAILING+ TO MAINTAIN
WATERPROOFING.
-
---ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS21078
12/05/2022
BID SET
A101First Floor andRoof PlansGOATAdditionSCALE: 3/16" = 1'-0"A101
1 First Floor Plan
SCALE: 3/16" = 1'-0"A101
2 Roof Plan
310
09
310
06
10
310310
10
#DESCRIPTION DATE
1 Addendum 1 03-03-2023
2 Permit Revision 04-06-2023
11
1
1
1
1
1
1
2
2