HomeMy WebLinkAbout06080063 Site Plan
~
~~
Schneider
The Schntidcr Corporf,UoD.
6001 OUS AveJlue
Hiatoric Fort &rriaoD
lodianapolii. lndWa -<<12111-1037
317-623-7100
317-626-7200 FAX
I
This Plot Plan Prepared for: R.H. of Indlono
Lot # 226 , contoining 11,200 S.F.:!:, in
Clo)boume
Section I 3
INSTR. I 2Q0.4{)(]()80247
P.C. I 3, Slide I 533
HomDlon Counly, aoy lllp
Sec 30. ll8N. R03E
13462 SALAMONE WAY
Cormel, IN 46074
Prepored Dole: 08/07/06: By KAG
Proposed Bu)'llf(s): YI SHI & WEiWEN WANG
(SO'R/W)
Community Restrictions:
Side Yard:: 5'
Rear Yard = 20'
Aggregate:: 10' (S,H.)
Zoning:: 51
R.H. of Indiana
Finished Floor Elevation Information
Pod Grode = 912.9 per plan
Pod GlOde t 0.7' = Garage FFE (913.6)
GOlOge FFE + 1.5' = Residential FFE (915.1 )
Residential FFE - 9.0' = Basement FFE (906.1 )
DRIVEWAY SLOPE = 3.7%
h&inecrWa
SlU1'cYln&
lA.ndJeope Architecture
GJS .lJS
GeololJ
Plot PIon Leqend
U!OO]] Proposed Grodes
000.0 Exisling Gfodes
_OClO.O- Contour Glade
* Approx. lateral Location
-. - Sanitary Sewer lines
-a- Storm Sl:wer lines
- v - Water Service Unea
- - - - - - - Sub-Surface Drain Lines
. Wanhole (SoniIOfY 0( Storm)
. Beehive Inlet (Storm)
III Curb Inlet (SIOfTJ1)
D End Section (Storm)
.... rlre HydrOI'll
-o.o-...-F1owLlneofsll'ole
- - Building Line (BL / BSL)
- - - - - - - Easement Line
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC=912.21
Downstream I.lanhole, TC= 910.51
per record drawing.
, %" f\\l,
\-~'i-\'-I"'O'j f\~\'\
\\",r:, \..\) \..'1"
\..i'S '1,p\- f:) \..\) :of\(J
!\i~\- \\-()\J \..+''0
",()~-,,~'I- ~ \..\)
~ote; flie garage finished floor elevation ~C) ,v f:)\\\J ~\)~
IS 2.6 above the cwb ot the drive, per plan. '\ ~ ~
Ground Cover Calculations: ,,{:.. \>-- ~\-~\
Drive = 1,199 SH \)":'i-, ~'I-<;'; ,-,,9)
Public Walk = 339 SF I \O\) M()'" rj!...."'- ,,-'"-'
Private Walk =169 SFI c,'0~ Q~'3',,~ '"',
H',;roseeding =3,910 SFi '- ,,'-" (,'- \: ,,\j\j /' /'
1" "of! >>1" '(,\J'
Sod = 431 SYI, from ii;'.)S \)...1" /'
Rear of residence. \..~ ~ n 0 S"'- /" /"
.'.)\)1<' /'
\'.) /'
~ /"/
'0./
Sidewalk to be placed
l' from property line.
4' fruln back of curb,
per plan.
FLOOD HAZARD STAIEMENT
CERTIFICA TION
\\\\\\\\\\\111111111/1///
\\\\\\\'\ L C 111/0/
'"" ,S 'LJ'~
o ~'\ ..,..........I'h...~
~ z~ ,';:'G\S TEiy';;-...;y A~
~ _~'V N ,. /Vy
j<::::,i<r O. 0,.<:>\
~ 50303 ~
% . 51 A TE OF : !2
\ <:';J;;":'~P.t"p;,~~,,::,'\.~:I
~ V SUD\I\ #'
i'1111/. \\.... \\\\"$.
/1//111111111111\\\\\\\\\
~ ,,~\,
..".,..,"~oP
\C7' '1;9
~ l . ,~>~"
Ihis druwiflg is no! intended to bt represented as 0 retrocernent or
original boundary survey, u route survey, or a Surveyor Location Report.
,/
Flood Hazard Staternent: The oCCLJracy of any flood hazard data shown on this report
is suujeGt tQ nWIJ ::lcdl", uncertainty alld to ,HlY other uncenainty in locatioll {j( elevOllion 011
\118 referenced noud illSllf,-Hlce r"lll; Illap. ALL of tile within de::lcritJed land DOE'S NOT lie
wiU\in ttlul specii:ll flood 11o:JZJld 20l\e AE as said land plots by scale on flood insurance
(<ill; Illal) #180081 ll2DS F for the City of Carrllet.lndiana dated Februar)/ 19, 2003,
Note:
This drawing is based on construction plans or record
drawings, and is not based upon a field survey. The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should verify
e~isting conditions prior to any construction. Any i
discrepancy found on this drawing should be reported to
The Schneider Corporation immediately. failing to dol so
results in the contractors assumption of aU liability.
,
Note; The basement elevation, depicted hereon, has been
determined and based upon the pad grades and/Of contours
token from the construction plans for this subdivision. Unless
slated. no in/amotion about fluctuating water tables, soU
conditions, or soil twes has been provided or stated on said
plans. It is recommended that the basement finished tloor
elevat!ons be at least two feet (2') above the normal pool
elevation of any adjoining bodies of water, unless a study of
facts reveals otherwise. If during the excavation process any
ground water is witnessed, The Schneider CorpOfation should be
notified immediately. The basement elevotion should be raised
two feet (2') above the ground water, and odditioilal !
construction techniques should be incorporated to oIleviate
tutureproblerns.
Note: Sump pump(s) to be Detail of Ground/ Storm
placed by bulldef as needed. Water flow patt(j(/l to(
individual lots.
Vb06.0059124
Lot # 226
~
D
=JS;'3, =
o
Assumed NOfth
Scale: 1- '4 30'
Note: Builder to ensure positive
drainage away from structure(s).
Note:
The contractor is to maintain a minimum
distance at ten feet (10') between the
sallitary sewer and water line loterals.
~
'ib
"
~'O'i'::
",~'h
~Q'?'-
~ .
~'%- -y; -1-.
"'~
q, 'il--"'9'
'"' c-
'11' V'
/~
~
'"
RE~~ON II I
~O\E HOUSE 105" fROM LOT LINE
\18 I 06.0059416 I
08-07-06 I.lBK
~s\
Note: Per Carmt:! zoning ordinance 26,1.1 ; file
residential district limits height to twenty-five feet (25'),
however a dwelling may be increased in height to
thirty-five fed (35') provided the side and rear yards
ole increased an additional one foot (1') for each one
toot (1') the structure exceeds the first twenty-five feet
(25') in height
SIGlATURE :
OATE,
~GNATURE REPRESENTS COllFlRMATION Of RECEIPT Of PLOT PlAN BY CUSTO~ER.
~
T'l'PICAl SWAlE SECTION