Loading...
HomeMy WebLinkAbout06080063 Site Plan ~ ~~ Schneider The Schntidcr Corporf,UoD. 6001 OUS AveJlue Hiatoric Fort &rriaoD lodianapolii. lndWa -<<12111-1037 317-623-7100 317-626-7200 FAX I This Plot Plan Prepared for: R.H. of Indlono Lot # 226 , contoining 11,200 S.F.:!:, in Clo)boume Section I 3 INSTR. I 2Q0.4{)(]()80247 P.C. I 3, Slide I 533 HomDlon Counly, aoy lllp Sec 30. ll8N. R03E 13462 SALAMONE WAY Cormel, IN 46074 Prepored Dole: 08/07/06: By KAG Proposed Bu)'llf(s): YI SHI & WEiWEN WANG (SO'R/W) Community Restrictions: Side Yard:: 5' Rear Yard = 20' Aggregate:: 10' (S,H.) Zoning:: 51 R.H. of Indiana Finished Floor Elevation Information Pod Grode = 912.9 per plan Pod GlOde t 0.7' = Garage FFE (913.6) GOlOge FFE + 1.5' = Residential FFE (915.1 ) Residential FFE - 9.0' = Basement FFE (906.1 ) DRIVEWAY SLOPE = 3.7% h&inecrWa SlU1'cYln& lA.ndJeope Architecture GJS .lJS GeololJ Plot PIon Leqend U!OO]] Proposed Grodes 000.0 Exisling Gfodes _OClO.O- Contour Glade * Approx. lateral Location -. - Sanitary Sewer lines -a- Storm Sl:wer lines - v - Water Service Unea - - - - - - - Sub-Surface Drain Lines . Wanhole (SoniIOfY 0( Storm) . Beehive Inlet (Storm) III Curb Inlet (SIOfTJ1) D End Section (Storm) .... rlre HydrOI'll -o.o-...-F1owLlneofsll'ole - - Building Line (BL / BSL) - - - - - - - Easement Line Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC=912.21 Downstream I.lanhole, TC= 910.51 per record drawing. , %" f\\l, \-~'i-\'-I"'O'j f\~\'\ \\",r:, \..\) \..'1" \..i'S '1,p\- f:) \..\) :of\(J !\i~\- \\-()\J \..+''0 ",()~-,,~'I- ~ \..\) ~ote; flie garage finished floor elevation ~C) ,v f:)\\\J ~\)~ IS 2.6 above the cwb ot the drive, per plan. '\ ~ ~ Ground Cover Calculations: ,,{:.. \>-- ~\-~\ Drive = 1,199 SH \)":'i-, ~'I-<;'; ,-,,9) Public Walk = 339 SF I \O\) M()'" rj!...."'- ,,-'"-' Private Walk =169 SFI c,'0~ Q~'3',,~ '"', H',;roseeding =3,910 SFi '- ,,'-" (,'- \: ,,\j\j /' /' 1" "of! >>1" '(,\J' Sod = 431 SYI, from ii;'.)S \)...1" /' Rear of residence. \..~ ~ n 0 S"'- /" /" .'.)\)1<' /' \'.) /' ~ /"/ '0./ Sidewalk to be placed l' from property line. 4' fruln back of curb, per plan. FLOOD HAZARD STAIEMENT CERTIFICA TION \\\\\\\\\\\111111111/1/// \\\\\\\'\ L C 111/0/ '"" ,S 'LJ'~ o ~'\ ..,..........I'h...~ ~ z~ ,';:'G\S TEiy';;-...;y A~ ~ _~'V N ,. /Vy j<::::,i<r O. 0,.<:>\ ~ 50303 ~ % . 51 A TE OF : !2 \ <:';J;;":'~P.t"p;,~~,,::,'\.~:I ~ V SUD\I\ #' i'1111/. \\.... \\\\"$. /1//111111111111\\\\\\\\\ ~ ,,~\, ..".,..,"~oP \C7' '1;9 ~ l . ,~>~" Ihis druwiflg is no! intended to bt represented as 0 retrocernent or original boundary survey, u route survey, or a Surveyor Location Report. ,/ Flood Hazard Staternent: The oCCLJracy of any flood hazard data shown on this report is suujeGt tQ nWIJ ::lcdl", uncertainty alld to ,HlY other uncenainty in locatioll {j( elevOllion 011 \118 referenced noud illSllf,-Hlce r"lll; Illap. ALL of tile within de::lcritJed land DOE'S NOT lie wiU\in ttlul specii:ll flood 11o:JZJld 20l\e AE as said land plots by scale on flood insurance (<ill; Illal) #180081 ll2DS F for the City of Carrllet.lndiana dated Februar)/ 19, 2003, Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify e~isting conditions prior to any construction. Any i discrepancy found on this drawing should be reported to The Schneider Corporation immediately. failing to dol so results in the contractors assumption of aU liability. , Note; The basement elevation, depicted hereon, has been determined and based upon the pad grades and/Of contours token from the construction plans for this subdivision. Unless slated. no in/amotion about fluctuating water tables, soU conditions, or soil twes has been provided or stated on said plans. It is recommended that the basement finished tloor elevat!ons be at least two feet (2') above the normal pool elevation of any adjoining bodies of water, unless a study of facts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider CorpOfation should be notified immediately. The basement elevotion should be raised two feet (2') above the ground water, and odditioilal ! construction techniques should be incorporated to oIleviate tutureproblerns. Note: Sump pump(s) to be Detail of Ground/ Storm placed by bulldef as needed. Water flow patt(j(/l to( individual lots. Vb06.0059124 Lot # 226 ~ D =JS;'3, = o Assumed NOfth Scale: 1- '4 30' Note: Builder to ensure positive drainage away from structure(s). Note: The contractor is to maintain a minimum distance at ten feet (10') between the sallitary sewer and water line loterals. ~ 'ib " ~'O'i':: ",~'h ~Q'?'- ~ . ~'%- -y; -1-. "'~ q, 'il--"'9' '"' c- '11' V' /~ ~ '" RE~~ON II I ~O\E HOUSE 105" fROM LOT LINE \18 I 06.0059416 I 08-07-06 I.lBK ~s\ Note: Per Carmt:! zoning ordinance 26,1.1 ; file residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five fed (35') provided the side and rear yards ole increased an additional one foot (1') for each one toot (1') the structure exceeds the first twenty-five feet (25') in height SIGlATURE : OATE, ~GNATURE REPRESENTS COllFlRMATION Of RECEIPT Of PLOT PlAN BY CUSTO~ER. ~ T'l'PICAl SWAlE SECTION