Loading...
HomeMy WebLinkAbout06080086 Site Plan .~~ Schneider The Schnelder Corporation 6901 QUa AVIlIl\le w.t.rIc Fort _ IndW>4polia, Indiona <<.21'-1037 317-82'-7100 317-828-7200 FAX BaoInoorioo 3w...yIn& LandIo4po .lrchlloot.... GIS .IJS Geol"l1 I Plot Plan Legend This Plot Plan Prepared Fer: R.H. of IndlOna []QQ]] Proposed Grades Lot # 962 , containing 7,000 SJ.:!:, 'n 000.0 Existing Grades Vllago of Wostcloy ___ 000.0- COlltour Grade Soc&n # 6002 * Approx. Lateral LocatiOll - . - Sanitary Sewer lines INSTR. # 200500080673 -ar- Storm Sewer Unes PC 3 SUDE 791 - ~ - Water Ser~ce Unes . H I't Cou t - - - - - - - Sub-Surface Dram Lines am on n :y. Ooy Twp . Manh~e (Sanitary or Storm) See 19. 118N, R03E . 8eehive Inlet (Storm) 2495 Buckland Street (50'R ^'^ 1lIB. Curb Inlet (Storm) " ,,,, D End Section (Storm) Carmel, IN 46074 ..... Fire HjOrant Prepared Dote: 08/04/06: By. AMA - ... - ... - Flow Une of swale P osed 811....18): INVENTORY 8uilding Un, (8L / 8SL) rap 1fl4\ - - - - - ~ - Easement line Community Restrictions: Side Yard = 5' ~IN (ONE ~DE) Rear Yard::;: N/A Aggreg<1te = 20~ LOT '1110111, MIN. Zoning = SI Ground Cover Colculotjoos: Drive = 1,049SFt Pubiic Walk = 250 SF t Private Walk = 39 SFt HjOraseeding =N/A SFt Sod =325 Srt, entire l"rd. ORIII:WA Y SLOPE = 6,0~ 5' ONE ~DE Note: Sanitary Sewer Top of Cosling Information Upstream ~anh~e, TC= 903.58 Downstream Manhole. Te= 904.43 per pion. ~ ~ =1i3.= ~ , '" ~I ~< ~ TYPICAL SWALf SECTION Assumed North Scale: 1- '" 30' Note: The garage finished tloor eleV<ltiorl is 2.4' above middle of pavemeot at the drive, per plan. RH. of Indiana Finished Floor Elevation Information 1B~ at face of curb=905.0 1B~ at aliey=904.0 Note: Per Carmel zoning ordinance 26.1.1 : The r"~ential district limits height to twenty-fi", feet (25')'.:J however a dwelling may be increased in height to thirty-fi", feel (35') prolided the side and reor )Qrd, BUCKLAND ore increased an additional one foot (1') for each one , ~ roM foot (1') the structure exceeds the first twenty-five feet0 29.0 ELfV=905.0 (25') in heighl. B-B Sidewalk to be placed l' trom property line, 5.5' from back of curb, per plan. Proposed Grade at Swale=905.9 high side Garage FFE at weatheriip=908.9-2.54=9D6.36 Residential FFE=905.9+3.0=908.9 Basement FFE = 908,9 - 10.0 = 898,9 :.\\\\\\\\ll.tllIIWI/{IIJIII/, #\'\ S L C. Y/~ # ~ ,"''''':'''''.;P0~ :# <,,~,,';:'G\S TEFr~'",~....o~ ",~...",~ No 0'",.4" I { 50303 \ I % " STATE OF.. ff ~ /", I ... ."<':t. ffj ~{~;I>..tvOIA~~:"" ~~~ ~ 'm'S"'U'''R'~i \. '" ,# ~ijll. ., :.\\\'V:-" '/1/111/1/111111\\1\\\\\\\\\ Note ~ Tne contractor is to maintain a minimum ~, l dIStO(jC~ of ten feet (10') between the . \ -L-' samtury sewt:r and water line latel'ols. I'his drawing is not Intend d to be replesenled os a retrocernent or original boundary survey, 0 roule survey, or 0 Surveyor Location Report All service laterals crossing at curb ore stamped: SA= Sanitary Sewer SS= Subsurface Drain W= Water Area of water tap to be back filled with granular material to within 10- of Area 01 water top to be restored to its' original condition prior to construction. FLOOO HAZARD STATEMENT CERTIFICATION PIE:RS~ A ~ '" FRWMlSY i<i. .r; '" <!; RESIDENCE 0> ~ SCREEN 36.00' P CH 7.0' 7.0' - 13.58' a;iP .", 5.00 ~OO' 0 0 0 ,MAG[ '" 22.00 8. 0 l:R_CE .r; 10.00 "" DOOR '" I 0> N ,.. ~ ~ THREE CAR a. GARACE . N 32.00' p . 8 c~c. DRIly[ . .,' / ._-~--- 12' LLEY ESMT gO 17 Granular bock fiU suggested under driveway at sanitary sewer laleral trench, woter line trench and any other excavated areas. (U situation occurs) Location of utilities on plot plan are general locations per plan and should be verified in the field. Note: (secondary areas - Westday) Max. height 35' on lots 100' and larger (to eve line) 30' on less than 100' Max. coverage: 50% Note: (primary areas - Westdoy) Max. height: 30' Build-up line: 2 stories Mox. coverage: 501. Pod elevatioo shown is per plans and is not the os-built elevation. The information for the elevation difterence between the primary finished floor elevation to the top of basement Vlail and to the basement finished Iloor was provided by the client. Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporatioo does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any , discrepancy found on this drawing should be reported 10 The Schneider Corporation immediately; foiling to do so results in the controctors assumption of 011 liability. Note: The bosement elevation, depicted hereon, has been determined and based upon the pod grades and/or contours token from the construction plans for this subdiV'ision. Unless stated, no information about ftuctuating water tables, soU conditions, Of soil t)pes hos been provided or stated an said pions. It Is recommended that the basement flllished floor eleV<ltiOlls be at least two feet (2') above the normal pool eleV<ltion of any adjoining bodies of water, unless a study of focts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevutiOll should be raised two' feet (2') above the g(Qund water, and additional cOllstruction techniques should be incorporated to aUe'fiote future problems. Detail of Q-ound/ Storm Water flow pattern fO( individual lots Note: Sump pump(s) to be placed by builder os needed. Vb06,0059139 Lot # 962 I \ I I 1/01 1/1 \ I I 1 Note: Builder to ensure positivll drainage away from structure(s). 4~ STREET RCti aJRB ~ 40 Flood Hazard Statement: The accuracy of <my lJood hazard Llata :;>hown on Ihis report i:;> :;>ulJjecl 10 map scale uncertainty ancJ to any other uncerlainty in location or elevalion onlhe rcf8renced fjoocl insurance rate map. ALL of the within described land DOES NOT lie within thaI special flood hazard zone AE as said land plols by scal8 011 flood insurance rate map #180081 0205 F for 1118 City of Cannel Indiana dated February 19 2003 SGHA TURE : N(C REI'ISON 1 ADDED BASE~ENT FIE 8-10-06 SKN OATI': ~GHA TURE REPRESENTS CONRR~A nON OF RECEIPT OF PLOT PLAN BY CUSIQljER.