HomeMy WebLinkAbout06080109 Site Plan
..,..
~)~.'..:.
" .1. (
~-.L":"."':~:.J:1_
~
n.. _ CorpcntIm>
IIlIOI ou. 4_
_POII_
,...11_""'.. IDdluiI 4I2l8-1037
8lHI28-71<1lf
8l7-lIlIlH'illO P.II
...-me
lIlunJIaI
Loodoeoj>o-
GIll.1Il
Clookv
Note:
This drowing Is bosed on construcllon pions or record
drowings, ond Is not bosed upon 0 field SUMY. The
Schneid... Cotporotlon does not warrlllt the accuracy or
suffICiency of this informallon. Contractors shouldl verify
existing conditions prior to any construction. My
discrepancy found on this drawing should be reported to
The Schneid... Cotporatlon immediately; faling to do so
results In the contractors assumption of 011 flablity.
Note::
Per ConneI zoning ordinonco 26.1.1 :
Th. residential district Ilmlla hekjlt to twenty-tIYo
teet (25'), ho_ 0 dwelIiIg moy bo increosocl in ~I
to thlrly-tIYo feel (351 proYlded the .Ide ond rear yard.
are increosocl on oddltlon~ one foot (11 for lOCh
one foot (1') the etructure exceeds the first
twenty-fl... feet (251 in h.kjll
This Plot PlIII PrIpGl eel For: R.H. of Indiana
Lol # 107 , conlaining 5,866 Sf.:!:, in
Stlllfard Perk
SectIan, 1
D<<iDt , 200500009385
P.c. , 3, Slide ~
CERlIJ:1CAlE of cn~
~ , 200500044195
- QoyT",,;-HcmltOn CoUnty
See 29, 118N, R3E
3493 WlNDY KNOLL LANE (70'R/W)
Ccnnel, IN 46074
Prepared Dale: 08/11/06 : By: KAG
Propoeed 1kl)W(8~ LLOYD C & BARABAR
E. Y/HITE
Community Restrictions:
Side Yard -3' min.
Rear Yard. N/A
Awogote - 6 (8.H.)
R.H. of Indiono
Finished Floor Ele",lIon Information
Pod Grode = 917.4 per plan
Pod Grode + O.r = Garage FFE (918.1 )
Garage FFE + 0.5' = Resldenll~ FFE (918.6)
ORlIEWAY SllPE- 10~
Nole : The garage finished ffoor el....tJon
Is 1.3' obo... the curb at the drM, per pion.
Ground Cover Calallotlons - 4 'I
onve = 609 Sft ~ , !;;
Public Walk = 130 Sft ,'.:!f- '"
Pri",le Walk = 48 sri' -:y.o;
Hydr....ding =n/a sri ,fSI. ~
Sod =349 SYi, from ~
entire )'CItd ~
~
~
1lH' 715
IC=9IS.eo
PER PlNl
FLOOD HAZARD STATEMENT
CERTlFICA TlON
~1I\\\\\\I\11II11I1/"I"lh
~\~ ~ L. (};~
#~~ ............. "..~ft;,
~ ...~G\S TE:~~.......A~
"'<::::, ..''1- No 0"';0'"
f ( S0303 ') j
% ..... STATE OF ..: iff
~ /.... .... ~
~~~ ...~"'DIA"'!:... ~~
~ ~ ..S....U..o,if.-I\: .#
~41/, 1\" \.'I\~~
W/f/fffl/"'IIIII\\\\\\\\~
O-o-l~
Plot P111l Legend
I]lIllI] Proposed Grades
000.0 ExIsting Grades
_000.0- Contour Grode
* Approx. Lateral location
- 8 - Sanitary Sewer Unes
- If- Storm Sewer Unes
- v - Water SerIIce I.i>..
- - - - - - - Sub-Surface Oraln Lines
. MlIIhole (Sanitary or Storm)
. BeOhive InleqStorm)
III Cum Inlet (Storm)
D End Section (Storm)
.... Fire H~ront
- . . . - . . . - Flow Une of swale
- Buldlng Une (BL / BSl)
------- Easement Line
Lot # 107
Vb06.0059636
o
~
=~=
Oetol of Ground/ Stonn
Water IIow potlem for
indMcll~ lob.
Note: Sanitary Sewer
Top of Costing Information
Upstream Monhole, TC= 916.60
Oownstream Manhole, TC= 917.50
per pion.
SIdewalk to bo placed
7' from prcperly line.
5' from bock of "'""
per pion.
o
A:ssumed North
Scale: 10... YJ'
Note: BuDder to ensure
positive dralnogo awoy
from sUucture(s).
1lH,71S
TC=917.50
PER PI.AH
Note:
The contractor is to maintain a minimum
distance of ten feet (10') botween the
sooitry sewer ond water lite laterals.
~
TYPICAl.. SWALE SECTlON
This drawing is not intended to be represented os a retracement or
original boundary survey, a route survey, or a Surveyor Location Report. '
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report Is subject to
map scale uncertainty and 10 any other uncertainty In location or elevaUon on the referenced flood
insurance rate map. ALL ollha within described land DOES NOT LIE within that special nood hazard
zone A as said land plots by scale on nood insurance rale map # 18057 Q205F for City of Carmel,
Indiana (maps dated February 19, 2003).
SIGNA lURE :
DATE:
S~AIURE REPRESENTS canwAnON Of RECEIPT Of PLOI PlAN BY WSIOllER.