Loading...
HomeMy WebLinkAboutElevations6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE:DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON DRAWINGS. DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF ARCHITECT IMMEDIATELY IN WRITING. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 10 PROJECT IMAGE DRAWING LIST ARCHITECTURE/DESIGN CONTACT PROJECT DESCRIPTION KEY PLAN AREA MAP STRUCTURAL CONSULTANT PROJECT GENERAL NOTES 3/2/2023 10:11:09 AMG-0 COVER SHEET 22.020 10.05.2022PORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032PORT COCHERE 12999 PENNSYLVANIA STREET CARMEL, INDIANA 46032 10.05.2022 Project Status MAJESTIC CARE GENERAL G-0 COVER SHEET G-1 OVERALL LIFE SAFETY PLAN G-2 LIFE SAFETY PLAN G-3 2021 ICC - ADA REQUIREMENTS ARCHITECTURE AD-1 EXISTING CANOPY DEMOLITION PLAN AND ELEVATION STRUCTURAL S0.01 GENERAL NOTES & SCHEDULES S1.02 FOUNDATION & FRAMING PLAN S3.01 BUILDING SECTIONS S5.01 TYPICAL SECTIONS AND DETAILS S8.01 SHEET SPECS S9.01 3D MODEL ARCHITECTURE A-0.1 REQUIRED WOOD COATING SYSTEMS A-0.2 REQUIRED WOOD COATING SYSTEMS A-1 PROPOSED PORTE COCHERE PLANS A-2 PROPOSED PORTE COCHERE REFLECTED CEILING PLAN & DETAILS A-3 PROPOSED PORTE COCHERE ELEVATIONS & SECTIONS A-4 EXTERIOR ELEVATIONS - EAST A-5 EXTERIOR ELEVATIONS - NORTH A-6 EXTERIOR ELEVATIONS - WEST A-7 EXTERIOR ELEVATIONS - SOUTH ARX 360, INC. 6018 ORCHARD HILL LANE INDIANAPOLIS, IN 46220 SCOTT PEREZ, AIA PHONE: 317.520.2550 SCOTT@ARX3SIXTY.COM MIDWEST DESIGN GROUP 3850 PRIORITY WAY S DR. #222 INDIANAPOLIS, IN 46240 DANIEL SWANSON, PE PHONE: 317.442.7062 DSWANSON@MIDWEST-DESIGNGROUP.COM THIS PROJECT CONSISTS OF A NEW, EXTERIOR CANOPY. GENERAL 1. IT IS THE BUILDING OWNERS AND OR TENANTS RESPONSIBI LITY TO REVIEW AND CHECK THE CONSTRUCTION DOCUMENTS PRIOR TO CONSTRUCTION AND VERIFY LOCATIONS, SIZES, QUANTITIES AND SPECIFIC MATERIALS USED IN CONJUNCTION WITH THE BUILDING OWNERS SPECIAL EQUIPMENT LAYOUT, USE OR FUNCTION. 2. THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE SPECIFIC DETAILS OF THEIR TRADE. 3. WORK SHALL BE IN ACCORDANCE WITH THE QUALITY STANDARDS OF THE TRADE AND SHALL BE INSTALLED IN COMPLIANCE, AS A MINIMUM STANDARD, TO APPLICABLE LOCAL, STATE, FEDERAL CODES AND MANUFACTURER'S RECOMMENDATIONS. 4. WORK SHALL BE WARRANTED SATISFACTORY, IN MATERIALS AND WORKMANSHIP IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 5. THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING AND MAJOR ARCHITECTURAL ELEMENTS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT INDICATE OR DESCRIBE THE WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE CONTRACTOR SHALL FURNISH THE ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 6. COMMENCING WORK BY A CONTRACTOR CONSTITUTES ACCEPTANCE OF THE CONDITIONS AND SURFACES CONCERNED. IF SU CH CONDITIONS OR SURFACES ARE UNACCEPTABLE, THE OWNER AND ARCHITECT SHALL BE NOTIFIED IMMEDIATELY AND WORK SHOULD CEASE UNTIL THE UNACCEPTABLE CONDITIONS CAN BE REMEDIED. 7. ITEMS NOTED "N.I.C." (NOT IN CONTRACT), "BY OWNER" OR "EXISTING" SHALL NOT BE INCLUDED IN THE CONTRACT. PROVISIONS SHALL BE M ADE BY THE RESPECTIVE TRADES TO ALLOW FOR THE INSTALLATION OR PRESERVATION OF THE ITEMS NOTED. FINISHES OF FLOORS, BASES. WAINSCOT, WALLS AND CEILINGS BEHIND, UNDER AND OR OVER THESE ITEMS SHALL BE INCLUDED IN THE GENERAL CONTRACT UNLESS OTHERWISE INDICATED. 8. THE COORDINATION OF THE MATERIALS, LABOR AND WORKMANSHIP IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR -TO INCLUDE ITEMS FURNISHED BY TENANT FOR CONTRACTOR INSTALLATION. 9. DIMENSIONS ARE TAKEN FROM THE FACE OF MASONRY WALLS, COLUMN CENTER LINES, FINISH FACE OF EXISTING WALLS AND/OR STUD FACE OF NEW WALLS UNLESS OTHERWISE INDICATED. 10. DO NOT SCALE DRAWINGS. REFER TO DIMENSIONS ILLUSTRATED ON DRAWINGS. NOTIFY THE ARCHITECT OF DISCREPANCIES OR FOR CLARIFICATION. 11. THE CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS AND AMPLE TIME TO AVOID DELAYS IN CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT WITHIN (7) DAYS OF CONTRACT AWARD IF ANY ITEM IS FOUND TO BE UNAVAILABLE OR HAVE A LONG LEAD TIME THAT IS NOT COMPLIANT WITH THE CONSTRUCTION SCHEDULE. 12. THE CONTRACTOR SHALL PROVIDE SUBCONTRACTOR WITH COM PLETE ARCHITECTURE AND ENGINEERING DRAWINGS. THE CONTRACTOR SHALL NOTIFY ARCHITECT OR ENGINEER IN WRITING, OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO BID DATE FOR RESOLUTION. 13. THE CONTRACTOR SHALL PROVIDE AND EXECUTE A WASTE MANAGEMENT PLAN IN COMPLIANCE WITH CURRENT LOCAL JURI SDICTION REGULATIONS. AT A MINIMUM, THE CONTRACTOR SHALL REU SE OR RECYCLE AT LEAST 50% OF DEMOLITION AND CONSTRUCTION DEBRIS GENERATED AS PART OF COMPLETING THE SCOPE OF WORK. PURSUIT OF ALTERNATE COMPLIANCE PATHS OR EXEMPTIONS SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO COMMENCING WORK ON SITE. DOCUMENTATION OF RECYCLING REUSE AND LANDFILL QUANTITIES (BY WEIGHT) SHALL BE PROVIDED TO THE ARCHITECT AT REGULAR INTERVALS THROUGHOUT THE PROJECT, AND TO THE LOCAL JURISDICTION AS REQUIRED BY REGULATIONS. PROJECTS PURSUING LEED OR OTHER GREEN BUILDING CERTIFICATION HAVE ADDITIONAL REQUIREMENTS THAT MAY SUPPLEMENT THE MINIMUM REQUIREMENTS LISTED HERE. 14. THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WI TH ALL CONTRACT DOCUMENTS IN THEIR ENTIRETY. SURVEY THE PROJECT AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS IN SCOPE OF WORK. ALL COSTS SUBMITTED SHALL BE BASED ON THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY DISCREPANCY AND OR UNCERTAINTY AS TO WHAT MATERIAL OR PRODUCT IS TO BE USED SHOULD BE VERIFIED WITH THE ARCHITECT, IN WRITING. 15. CONSTRUCTION SHALL COMPLY WITH APPLICABLE FEDERAL, LOCAL, AND STATE CODES AND ASSOCIATED AMENDMENTS. 16. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES REQUIRED FOR SAFE EXECUTION AND COMPLETION OF WORK AND FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS IN PROGRAMS IN CONNECTION WITH WORK. 17. ERRORS, OMISSIONS, OR INCONSISTENCIES ON THESE DRAWINGS OR VARIATIONS OR AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS IN OUR REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING, IMMEDIATELY. 18. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED IN WRITING IMMEDIATELY. 19. CONTRACTOR SHALL VERIFY DIMENSIONS IN THE FIELD AND NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCI ES PRIOR TO CONSTRUCTION. 20. CONTRACTOR SHALL VERIFY MEASUREMENTS AT SITE AND BE RESPONSIBLE FOR ACCURACY AND CORRECTNESS OF SAME. 21. CONTRACTOR SHALL COORDINATE HIS WORK WITH E TRADES. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. 22. STORE MATERIALS IN CONDITIONS DESIGNATED BY MANUFACTURER SPECIFICATIONS. 23. REMOVE RUBBISH FROM PREMISES DAILY OR MORE FREQUENTLY AS DIRECTED. 24. WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. 25. THE CONTRACTOR SHALL VERIFY THE SIZE, LOCATION, OPENINGS, AND CHARACTERISTICS OF THE WORK AND EQUIPMENT FURNISHED BY THE OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER BEFORE STARTING ANY CONSTRUCTION RELATED TO SIDE WORK AND/OR EQUIPMENT. 26. MATERIALS SHALL BE NEW AND SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURERS INSTRUCTIONS AND/OR RECOMMENDATIONS UNLESS INDICATED OTHERWISE IN THE DRAWINGS AND SPECIFICATIONS. 27. BRACE WALLS BETWEEN WORKDAYS AS NECESSARY TO GUARANTEE STABILITY. 28. DO NOT SCALE DRAWINGS. BUILDING RULES 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CURRENT COPY OF THE BUILDING RULES AND REGULATIONS FROM THE BUILDING OWNER OR PROPERTY MANAGER. COMPLIANCE WITH THE BUILDING RULES AND REGULATIONS SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THIS PROJECT. 2. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR ACCESS TO THE SPACE FOR ONGOING CONSTRUCTI ON WORK. DISRUPTIVE OR POTENTIALLY HAZARDOUS CONSTRUCTION ACTIVITIES SHALL BE COORDINATED TO OCCUR AFTER NORMAL BUSINESS HOURS TO MINIMIZE THE DISTURBANCE TO BUILDING OCCUPANTS AND END USERS. THE CONTRACTOR SHALL REVIEW PROJECT PHASING AND DETAILED CONSTRUCTION SCHEDULE PLANS WITH BUILDING OWNER AND ARCHITECT PRIOR TO BID AND START OF CONSTRUCTION. 3. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER AND OR PROPERTY MANAGER FOR DELIVERY TO THE SPACE OF BUILDING MATERIALS. THE CONTRACTOR SHALL COORDINATE SUCH DELIVERIES IN A MANNER WHICH POSE NO HAZARD TO ANY PERSONNEL WITHIN OR AROUND THE BUILDING AND CONSTRUCTION SITE. 4. TRANSPORT TRASH, RUBBISH AND DEBRIS FROM THE SITE AND LEGALLY DISPOSE OF SAME. THE MANNER OF REMOVAL M UST BE CONFIRMED WITH THE BUILDING OWNER AND AS ALLOWED BY CITY AND STATE REGULATIONS. 5. REFERENCE BUILDING SCHEDULE FOR USAGE AS PART OF THESE CONTRACT DOCUMENTS. NORTH TRUE NORTH TRUE KEY PLAN SCALE: NOT TO SCALE PROJECT LOCATION DN LIFE SAFETY GENERAL NOTES A. SITE ELEMENTS SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE CIVIL DRAWINGS FOR SITE INFORMATION. B. STRUCTURAL ELEMENTS SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR FOUNDATION AND FRAMING INFORMATION & FRAMING DIMENSIONS. C. PLUMBING FIXTURES SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE PLUMBING DRAWINGS FOR INFORMATION CONCERNING PLUMBING FIXTURES AND PIPING SYSTEM(S). D. MECHANICAL ELEMENTS SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE MECHANICAL DRAWINGS FOR INFORMATION CONCERNING HVAC SYSTEM(S). E. ELECTRICAL AND LIGHTING FIXTURES SHOWN HERIN ARE FOR REFERENCE ONLY. SEE ELECTRICAL DRAWINGS FOR INFORMATION CONCERNING POWER, LIGHTING AND COMMUNICATION SYSTEM(S) AS WELL AS FIRE, SMOKE, AND EMERGENCY FIXTURES. F. REFER TO PARTITION TYPES ON G001 FOR FURTHER FIRE SEPARATION REQUIREMENTS. G. CONTRACTOR TO PROVIDE ALL ADDITIONAL FRAMING NECESSARY FOR ALL OPENINGS AND SUPPLEMENTAL FRAMING ABOVE PARTITIONS. H. ALL FIRE RATED ASSEMBLIES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH TESTED ASSEMBLIES INDICATED. I. EXTEND FIRE RATED PARTITIONS, BARRIERS, AND OTHER SEPARATIONS TO BOTTOM OF ROOF DECK ABOVE AND TO EXTERIOR WALL. SEAL JOINT BETWEEN EDGES OF PARTITION WITH FIRE RATED SEALANT AND/OR INTUMESCENT ASSEMBLY. J. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES SHALL BE FIRE-SEALED IN ACCORDANCE WITH APPROVED MANUFACTURER'S DETAIL FOR LOCATION, TYPE OF CONSTRUCTION, PENETRATING ITEM AND RATING REQUIRED. K. ALL DUCTWORK, DIFFUSERS AND GRILLES PENETRATING FIRE-RATED WALLS, CEILINGS AND FLOORS SHALL HAVE THE APPROPRIATE TYPE OF FIRE/SMOKE DAMPER IN ACCORDANCE WITH THE TYPE OF CONSTRUCTION BEING PENETRATED AND THE FIRE/SMOKE RATING REQUIRED. L. ALL LIGHT FIXTURES AND ELECTRICAL DEVICES PENETRATI NG FIRE-RATED ASSEMBLIES SHALL BE UL-LISTED FOR INSTALLATION IN THE ASSEMBLY OR SHALL BE INSTALLED SUCH THAT THE FIRE-RATING IS NOT COMPROMISED. M. SMOKE RESISTANT CONSTRUCTION SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE CODES. AREA SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING BE CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE OF SM OKE. THE PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF ASSEMBLY ABOVE. DOORS SHALL BE SELF OR AUTOMATIC CLOSING. DOORS SHALL NOT HAVE AIR TRANSFER OPENINGS AND SHALL NOT BE UNDERCUT IN EXCESS OF CLEARANCE PERMITTED WITH ACCORDANCE TO NFPA 80. N. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS IS UNDERSTOOD TO NOT BE WITHIN THE BUILDING. STORAGE OF ANY MATERIAL IS TO BE IN COMPLIANCE WITH ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDI CTION. CAPACITYCLR EXTERIOR EXIT 39"195 CAPACITYCLR EXTERIOR EXIT 33" 165 CAPACITYCLR EXTERIOR EXIT 68" 340 CAPACITYCLR EXTERIOR EXIT 33" 165 CAPACITYCLR EXTERIOR EXIT 80" 400 CAPACITYCLR EXTERIOR EXIT 32" 150 CAPACITYCLR EXTERIOR EXIT 45" 225 CAPACITYCLR EXTERIOR EXIT 80" 400 CAPACITYCLR EXTERIOR EXIT 80" 400 CAPACITYCLR EXTERIOR EXIT 80" 400 CAPACITYCLR EXTERIOR EXIT 39" 195 CAPACITYCLR EXTERIOR EXIT 68" 340 ABDC BCD CDE F EFFGG GHH 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:15 AMG-1 OVERALL LIFE SAFETY PLAN 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032RENOVATION (EXISTING BUILDING) PRIMARY OCCUPANCY: NA GENERAL CODE INFORMATION:CONSTRUCTION TYPE: IV (WITH FIRE RESISTANT COATING) 2012 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2009 INDIANA ELECTRICAL CODE 2009 AMERICAN NATIONAL STANDARDS INSTITUTE ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES STANDARD (ANSI A117.1-2009) 2010 AMERICANS WITH DISABILITIES ACT ACCESSIBLE GUIDELINES (ADAAG) FOR BUILDINGS AND FACILITIES 2012 INTERNATIONAL FIRE CODE APPLICABLE CODES:2012 INTERNATIONAL BUILDING CODE WORK DESCRIPTION:DEMOLITION OF EXISTING CANOPY AND CONSTRUCTION... CARMEL, INDIANA 46032 12999 PENNSYLVANIA STREET OWNED BY:MAJESTIC CARE CODE INFORMATION 0 2010 40 NORTH TRUE NORTH PLAN EGRESS PATH A TYPE EGRESS PATH LENGTH TRAVEL A 62' - 6" 62' - 6" SCALE: 1" = 20'-0"1 PORTE COCHERE LIFE SAFETY PLAN EGRESS PATH B TYPE EGRESS PATH LENGTH COMMON BCD 19' - 0" TRAVEL B 188' - 1" 207' - 1" EGRESS PATH C TYPE EGRESS PATH LENGTH COMMON BCD 19' - 0" COMMON CD 35' - 8" TRAVEL C 189' - 11" 244' - 7" EGRESS PATH D TYPE EGRESS PATH LENGTH COMMON BCD 19' - 0" COMMON CD 35' - 8" TRAVEL D 236' - 11" 291' - 7" EGRESS PATH E TYPE EGRESS PATH LENGTH COMMON EF 25' - 6" TRAVEL E 94' - 4" 119' - 10" EGRESS PATH F TYPE EGRESS PATH LENGTH COMMON EF 25' - 6" COMMON FG 50' - 8" TRAVEL F 49' - 10" 126' - 0" EGRESS PATH G TYPE EGRESS PATH LENGTH COMMON FG 50' - 8" COMMON GH 33' - 6" TRAVEL G 62' - 6" 146' - 8" EGRESS PATH H TYPE EGRESS PATH LENGTH COMMON GH 33' - 6" TRAVEL H 61' - 4" 94' - 10" DN LIFE SAFETY GENERAL NOTES A. SITE ELEMENTS SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE CIVIL DRAWINGS FOR SITE INFORMATION. B. STRUCTURAL ELEMENTS SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR FOUNDATION AND FRAMING INFORMATION & FRAMING DIMENSIONS. C. PLUMBING FIXTURES SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE PLUMBING DRAWINGS FOR INFORMATION CONCERNING PLUMBING FIXTURES AND PIPING SYSTEM(S). D. MECHANICAL ELEMENTS SHOWN HEREIN ARE FOR REFERENCE ONLY. SEE MECHANICAL DRAWINGS FOR INFORMATION CONCERNING HVAC SYSTEM(S). E. ELECTRICAL AND LIGHTING FIXTURES SHOWN HERIN ARE FOR REFERENCE ONLY. SEE ELECTRICAL DRAWINGS FOR INFORMATION CONCERNING POWER, LIGHTING AND COMMUNICATION SYSTEM(S) AS WELL AS FIRE, SMOKE, AND EMERGENCY FIXTURES. F. REFER TO PARTITION TYPES ON G001 FOR FURTHER FIRE SEPARATION REQUIREMENTS. G. CONTRACTOR TO PROVIDE ALL ADDITIONAL FRAMING NECESSARY FOR ALL OPENINGS AND SUPPLEMENTAL FRAMING ABOVE PARTITIONS. H. ALL FIRE RATED ASSEMBLIES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH TESTED ASSEMBLIES INDICATED. I. EXTEND FIRE RATED PARTITIONS, BARRIERS, AND OTHER SEPARATIONS TO BOTTOM OF ROOF DECK ABOVE AND TO EXTERIOR WALL. SEAL JOINT BETWEEN EDGES OF PARTITION WITH FIRE RATED SEALANT AND/OR INTUMESCENT ASSEMBLY. J. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES SHALL BE FIRE-SEALED IN ACCORDANCE WITH APPROVED MANUFACTURER'S DETAIL FOR LOCATION, TYPE OF CONSTRUCTION, PENETRATING ITEM AND RATING REQUIRED. K. ALL DUCTWORK, DIFFUSERS AND GRILLES PENETRATING FIRE-RATED WALLS, CEILINGS AND FLOORS SHALL HAVE THE APPROPRIATE TYPE OF FIRE/SMOKE DAMPER IN ACCORDANCE WITH THE TYPE OF CONSTRUCTION BEING PENETRATED AND THE FIRE/SMOKE RATING REQUIRED. L. ALL LIGHT FIXTURES AND ELECTRICAL DEVICES PENETRATI NG FIRE-RATED ASSEMBLIES SHALL BE UL-LISTED FOR INSTALLATION IN THE ASSEMBLY OR SHALL BE INSTALLED SUCH THAT THE FIRE-RATING IS NOT COMPROMISED. M. SMOKE RESISTANT CONSTRUCTION SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE CODES. AREA SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING BE CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE OF SM OKE. THE PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF ASSEMBLY ABOVE. DOORS SHALL BE SELF OR AUTOMATIC CLOSING. DOORS SHALL NOT HAVE AIR TRANSFER OPENINGS AND SHALL NOT BE UNDERCUT IN EXCESS OF CLEARANCE PERMITTED WITH ACCORDANCE TO NFPA 80. N. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS IS UNDERSTOOD TO NOT BE WITHIN THE BUILDING. STORAGE OF ANY MATERIAL IS TO BE IN COMPLIANCE WITH ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDI CTION. 1 2 3 A B 4 5 6 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:16 AMG-2 LIFE SAFETY PLAN 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032RENOVATION (EXISTING BUILDING) PRIMARY OCCUPANCY: NA GENERAL CODE INFORMATION:CONSTRUCTION TYPE: IV (WITH FIRE RESISTANT COATING) 2012 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2009 INDIANA ELECTRICAL CODE 2009 AMERICAN NATIONAL STANDARDS INSTITUTE ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES STANDARD (ANSI A117.1-2009) 2010 AMERICANS WITH DISABILITIES ACT ACCESSIBLE GUIDELINES (ADAAG) FOR BUILDINGS AND FACILITIES 2012 INTERNATIONAL FIRE CODE APPLICABLE CODES:2012 INTERNATIONAL BUILDING CODE WORK DESCRIPTION:DEMOLITION OF EXISTING CANOPY AND CONSTRUCTION... CARMEL, INDIANA 46032 12999 PENNSYLVANIA STREET OWNED BY:MAJESTIC CARE CODE INFORMATION SCALE: 1/4" = 1'-0"1 PORTE COCHERE LIFE SAFETY PLAN 0 2 4 8 NORTH TRUE NORTH PLAN EGRESS PATH A TYPE EGRESS PATH LENGTH TRAVEL A 62' - 6" 62' - 6" NORTH TRUE KEY PLAN SCALE: NOT TO SCALE MAX.0' - 0 1/2"MAX.0' - 0 1/4"0' - 0 1/4"0' - 0 1/4"0' - 0 1/2"2 1 CARPET PILE HT.VERTICAL LEVEL CHANGE BEVELED LEVEL CHANGE 60" GRATING ORIENTATION GRATINGS PREDOMINANT DIRECTION OF TRAFFIC LONG DIMENSION PERP. TO ROUTE OF TRAVEL 1/2" MAX.MIN.24" 36" MIN. 60" MIN. MIN. 12" 36" MIN. MIN. 12"60" MIN.FRONT APPROACH PARALLEL APPROACH 10" MAX 30" CLEAR FLOOR SPACE 48"30"48"30"PARALLEL APPROACH .30" X .48"NOTE: 1.X IS LESS THAN OR EQUAL TO 15". 2.IF X IS GREATER THAN 15", THEN AN ADDITIONAL MANEUVERING CLEARANCE OF 12" SHALL BE PROVIDED AS SHOWN BELOW X .48"MIN.12"..X.48"30" NOTE: 1.X IS LESS THAN OR EQUAL TO 24". 2.IF X IS GREATER THAN 24", THEN AN ADDITIONAL MANEUVERING CLEARANCE OF 6" SHALL BE PROVIDED AS SHOWN BELOW X.48".30".6" FRONT APPROACH 9" MINIMUM6" MAX. TOE CLEARANCES SECTION30" MIN.17" - 25" PLAN SECTION27" MIN.MIN. 8" 11" MIN.30" MIN.25" MAX. PLAN KNEE CLEARANCES 9" MINIMUMWALKING PARALLEL TO WALL Sign or Obstruction PROTRUDING OBJECTS AND HEAD ROOM IN PEDESTRIAN WAY (WALKS, HALLS, CORRIDORS, PASSAGE WAYS, AISLES INCLUDING CLASSROOMS, OFFICES, ETC. AND OTHER CIRCULATION SPACES.)80" MIN.4" MAX.HIGHERTHAN 27"ANY AMOUNTCLEAR WIDTH 27" ORBELOW4" MAX >27" AND <80"4" MAX MAX.27"X > 12" POST-MOUNTED PROTRUDING OBJECTS 80" MIN.X > 12"POST UNLIMITEDUNLIMITED FIGURE 307.3 UNOBSTRUCTED FORWARD REACH LIMIT MAXIMUM SIDE REACH OVER OBSTRUCTION HIGH AND LOW SIDE REACH LIMITS ITEMS WITHIN DASHED LINE ARE WITHIN REACH CLEAR FLOOR OR GROUND SPACE SHALL EXTEND NO MORE THAN 25 in. UNDER THE OBSTRUCTION MAXIMUM FORWARD REACH OVER AN OBSTRUCTION (SECTION) NOTE: 1.WHEN X <= 20", THEN Y SHALL BE 48" MAX. 2.WHEN X IS >20" TO 25", THEN Y SHALL BE 44" MAX. FORWARD AND SIDE REACH MOUNTING HEIGHT FOR SHELVES & DISPENSERS (TO CONTROL DEVICE ) SWITCHES AND CONTROLS AND TELEPHONES (MAXIMUM TO TOP DEVICE) AGE 46" MAX.34" MAX.30".>10" TO 24"48" MAX..15" MIN.10" MAX..30"YX .48"15" MIN.48" MAX.HIGH (MAXIMUM) LOW (MINIMUM) Ages 3 & 4 Ages 5-8 Ages 9-12 18" MIN. 16" MIN. 40" MAX. 44" MAX. ADULT REF. DIAGRAMS 20" MIN.36" MAX. REF. DIAGRAMS CLEAR WIDTH OF AN ACCESSIBLE ROUTE MAX. 24" MIN. 48" MAX. 24"36" MIN.32" MIN.36" MIN.32" MIN.42" MIN. X < 48" 42" MIN.48" MIN.36" MIN. X < 48" 36" MIN.60" MIN.180 DEGREE TURNS HINGED DOOR MAXIMUM DOORWAY DEPTH DETAIL SLIDING DOOR FOLDING DOOR 32" MIN. 32" MIN. 32" MIN. 32" MIN.24" MAX.36" MIN. BARN DOOR 32" MIN.MAX.43" AFFVISION PANEL GLAZING PANEL (no viewing permitted through door)MIN.66"MIRROR ABOVE LAVATORY OR COUNTERTOPTO BOTTOM OF40" MAX.REFLECTIVE SURFACE74" MIN.FULL-LENGTH MIRRORTO BOTTOM OF35" MAX.REFLECTIVE SURFACE74" MIN.SLIDE SIDE APPROACH SLIDING AND FOLDING DOORSFRONT APPROACH SLIDING AND FOLDING DOORS48" MIN.42" MIN.54" MIN.42" MIN.LATCH SIDE APPROACH SLIDING AND FOLDING DOORS NOTE: ALL DOORS IN ALCOVE SHALL COMPLY WITH THE FRONT APPROACHES CLEARANCES NOTE: CLEAR FLOOR SURFACES AT MANEUVERING CLEARANCES SHALL BE LEVEL WITH NO HEIGHT TRANSITIONS OR SLOPES. (EXCEPTIONS: THRESHOLDS AT EXTERIOR DOORS THAT ARE ACCEPTABLE BY STATE AND FEDERAL AGENCIES). HINGE SIDE APPROACHES - SWINGING DOORS PULL SIDE 60" MIN.18" MIN. FRONT APPROACHES - SWINGING DOORS PUSH SIDE 48" MIN.X NOTE: X = 12" IF DOOR HAS BOTH A CLOSER AND A LATCH PULL SIDE YX PUSH SIDE 42" MIN.YNOTE: 1.X = 36" MIN. IF Y = 60" 2.X = 42" MIN. IF Y = 54" NOTE: Y = 48" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER HINGE SIDE APPROACHES - SWINGING DOORS PULL SIDE 48" MIN.Y24" MIN. X PUSH SIDE 42" MIN.YNOTE: Y = 54" MIN. IF DOOR HAS CLOSER 24" MIN. X NOTE: Y = 48" MIN. IF DOOR HAS CLOSER 48" MIN. TWO HINGED DOORS IN SERIES 60" MIN. 22" MIN12" MIN 24" MIN 22" MIN 60" MIN60" MINCLEAR FLOOR SPACE 60" MIN.WHEELCHAIR ACCESSIBLE WATER CLOSETS 16" - 18"17" - 19" AMBULATORY ACCESSIBLE WATER CLOSETS WATER CLOSET LOCATIONS Clear Floor Space56" MIN.60" MIN. WATER CLOSET CLEARANCE NOTE: THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNI TS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE (INCLUDING LAVATORIES). LAVATORIES MAY OVERLAP THE REQUIRED CLEARANCE AT WATER CLOSETS AT PRIVATE RESIDENTIAL DWELLING UNITS ONLY. 21" MAX 42" MIN. 54" MIN.33" - 36"17" - 19"36" MIN. 16" - 18" SIDE WALL BACK WALL GRAB BAR (TYP.) WALL HUNG TYPE17" MAX.13 1/2" MIN. MIN. 24" MIN. 12" FLUSH CONTROLS TRANSFER SIDE SIDE WALL 18" MIN18" MINMAX.48"DISPENSER OUTLET LOCATIONGRAB BAR, FLUSH CONTROLS, & SEAT HEIGHT REQUIREMENTS 25" MAX. 17" MIN. 6" MAX.8" MIN.9" MIN.27" MIN.34" MAX.LAVATORY SINK OF TOE CLEARANCE 17" MIN. & 25" MAX. TO EDGE HOT WATER AND DRAIN PIPES UNDER LAVATORIES AND HANDICAP ACCESSIBLE SINKS SHALL BE INSTALLED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. STALL TYPE 13 1/2" MIN. URINALS NOTE: PROVIDE CLEAR FLOOR SPACE COMPLYING WITH FORWARD APPROACH (305) AT ACCESSIBLE URINALS TOILET COMPARTMENT CLEARANCES ADULT HUNG WC 56" MIN. AT ADULT FLOOR MOUNTED 59" MIN. AT WC AND ALL CHILDREN'S WC TOE CLEARANCE REQUIRED AT FRONT AND ONE SIDE EXCEPTION: TOE CLEARANCE NOT REQUIRED AT FRONT PARTITION IF 62" DEPTH AT WALL HUNG WC OR 65" DEPTH AT FLOOR MOUNTED WC. TOE CLEARANCE NOT REQUIRED AT SIDE PARTITION IF 66" CLEAR WIDTH IS PROVIDED. (REQUIRED IF TOTAL TOILET + URINAL FIXTURE COUNT IS GREATER THAN 6)MAX.0' - 4"MAX. 0' - 4"ALTERNATE DOOR LOCATION 42" MIN. DOORS AT TOILET COMPARTMENTS TO COMPLY WITH 404 (EXCLUDING LATCH SIDE APPROACH CLEARANCE WIDTH REQU IRED, WHICH SHALL BE AS SHOWN IN THE DIAGRAM TO THE LEFT). DOORS SHALL BE SELF CLOSING, WITH A DOOR PULL COMPLYING WITH 404.2.7 PLACED ON BOTH SIDES OF THE DOOR, NEAR THE LATCH. DOOR MAY NOT SWING INTO THE REQUIRED MINIMUM CLEAR FLOOR SPACE. COATS AND SHELVES (IF PROVIDED) SHALL BE INSTALLED WITHIN REACH RANGES AS SPECIFIED IN 308.37" MIN.60" MIN. 42" MIN. AMBULATORY ACCESSIBLE TOILET COMPARTMENT CLEARANCES MIN. 0' - 6"MIN.0' - 6"REQUIRED TOE CLEARANCE AT FRONT AND ONE SIDE PARTITION. TOILET COMPARTMENT TOE CLEARANCES ADULTS:0' - 9" MIN.0' - 6"12" MIN.CHILDREN:PARTITIONINSIDE STALL COUNTER MOUNTED SINK 30" MIN.PLANEQEQDASHED LINE REPRESENTS CLEAR FLOOR SPACE REQUIREMENTS, AS PER 305 PARALLEL APPROACH IS PERMITTED FOR LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN AGE 5 AND UNDER. 0' - 11" MIN. LAVATORY AND SINK REQUIREMENTS MAX. 0' - 6"MIN.0' - 9"MIN. 0' - 8" Dashed Line represents minimum Knee Clearance requirements, as per 306.3 TO RIM OF SINK34" MAX.25" Max. 17" Min. 11" MIN.27" MIN.NOTE: PROVIDE 24" CLEARANCE TO BOTTOM OF SINK/APRON AND 31" TO TOP RIM OF SINK FOR LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN AGED 6-12 39"-41"18" MIN39" - 41"24" MIN 36" MAX 42" MAX GRAB BAR HEIGHT 20" - 25" 25" - 27" TOILET SEAT HEIGHT 12" - 15" GRADE LEVEL/AGE AGES 3 AND 4 MOUNTING HEIGHTS FOR WATER CLOSETS SERVING AGES 3 THROUGH 12 15" - 17" WC CENTERLINE DISPENSER HEIGHT AGES 5 AND 8 AGES 9 AND 12 18" - 20"11" - 12" 14" - 17" 17" - 19" 14"12" 12 " - 15" 15" - 18" 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:18 AMG-3 2021 ICC - ADA REQUIREMENTS 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032CHAPTER 3: BUILDING BLOCKS TURNING SPACE - CIRCULAR GRATINGS T-SHAPED TURN SPACE CLEAR FLOOR SPACES CLEAR FLOOR SPACES IN ALCOVES KNEE AND TOE CLEARANCES PROTRUDING OBJECTS MOUNTING HEIGHTS PROPORTIONS OF INTERNATIONAL SYMBOL OF ACCESSIBILITY ACCESSIBLE ROUTE CHAPTER 4: ACCESSIBLE ROUTE CLEAR DOORWAY WIDTH & DEPTH VISION PANEL HEIGHTS MIRRORS MANEUVERING CLEARANCE AT DOOR WATER CLOSET AND TOILET COMPARTMENTS 1 2 3 4 5 6 3 AD-1 1 2 3 A B 4 5 6 1 5 6 6 3 TYP 1 TYP 4 TYP B 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:18 AMAD -1 EXISTING CANOPY DEMOLITION PLAN AND ELEVATION 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 460320 42 8 NORTH TRUE NORTH PLAN SCALE: 3/16" = 1'-0"1 EXISTING CANOPY DEMOLITION PLAN DEMOLITION KEYNOTES KEYNOTE DESCRIPTION 1 PROTECT EXISTING WALLS DURING CONSTRUCTION 2 PROVIDE PROTECTED EGRESS DURING CONSTRUCTION ACTIVITIES 3 DEMOLISH EXISTING CANOPY & STRUCTURE IN ITS ENTIRETY, TYP 4 REMOVE FOUNDATIONS & ASSOCIATED SUBGRADE, TYP PER COLUMN 5 REMOVE EXISTING SKYLIGHT SYSTEM COMPLETELY. PREPARE NEW WALLS AND CEILING FOR NEW GYP BOARD FRAMING INFILL, FIELD VERIFY EXTENTS 6 REMOVE EXISTING METAL ROOF & GUTTER SYSTEM AS REQUIRED SCALE: 1/4" = 1'-0"2 EXISTING CANOPY DEMOLITION ELEVATION 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:19 AMA-0.1 REQUIRED WOOD COATING SYSTEMS 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:20 AMA-0.2 REQUIRED WOOD COATING SYSTEMS 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032 DN 3 A-2 _____ A-2 2 1 A-3 _____ 2 A-3 _____ A-33 A-3 4 CONTROL JOINTS @ SLAB, TYP SLOPE 1:12 MAXSLOPE WALKWAY NO MORE THAN 1:20 IN ANY DIRECTION AWAY FROM BUILDING ENTRY AND ADA RAMP 1 2 3 A B 4 5 6 KYNAR COATING STANDING SEAM METAL ROOFING SYSTEM W/ CONCEALED FASTENERS CONTINUOUS METAL GUTTER & DOWNSPOUT SYSTEM, TYP KYNAR COATED STANDING SEAM RIDGE CAP NOTE: EACH WOOD ELEMENT SHALL BE COATED W/ FIRE RETARDANT COATING SYSTEM PRIOR TO INSTALLATION. REFERENCE SHEETS IN THIS PACKAGE, TYP. 1 2 3 A B 4 5 6 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:21 AMA-1 PROPOSED PORTE COCHERE PLANS 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 460320 2 4 8 NORTH TRUE NORTH PLAN SCALE: 1/4" = 1'-0"1 PORTE COCHERE - PROPOSED FLOOR PLAN SCALE: 1/4" = 1'-0"2 PORTE COCHERE - PROPOSED ROOF PLAN 0 2 4 8 NORTH TRUE NORTH PLAN 1 A-3 _____ 2 A-3 _____ A-33 A-3 4 TONGUE & GROOVE PANELS (ON SLOPED CEILING, TYP) PREFINISHED, METAL BOX GUTTER & DOWNSPOUT SYSTEM NOTE: 1. EACH WOOD ELEMENT SHALL BE COATED W/ FIRE RETARDANT COATING SYSTEM PRIOR TO INSTALLATION. REFERENCE SHEETS IN THIS PACKAGE, TYP. 2. COORDINATE LIGHTING & ELECTRICAL FAN LOCATIONS. NEW LIGHTING & FANS TO REUSE EXISTING ELECTRICAL SUPPLY. 1 2 3 A B 4 5 6 X # PRECAST CONCRETE CAP, 1"OVERHANG 8x8 HEAVY TIMBER WOOD COLUMN FULL BED STONE 1 A CONCRETE FOOTING, SEE STRUCTURAL CONCRETE SLAB ON GRADE 2-PIECE SS SLIP ANCHORS @ 16" OC MAX FULL BED STONE 8x8 HEAVY TIMBER WOOD COLUMN A-2 4 AIR CAVITY COAT WOOD W/ PRESERVATIVE TREATMENT STAINLESS STEEL FLASHING SOLID CONCRETE BLOCK FOOTERS COMPACTED FILL, TYP B ± 6" 1 1/4" 1"2 1/2"5"CONTINUOUS SEALANT 2-PIECE MASONRY TIE, HOT DIPPED GALVANIZED, TYP COVER WOOD W/ 40 MIL ICE & WATER SHIELD BEHIND MASONRY METAL STANDING SEAM ROOF SYSTEM 5/8" ICE & WATER SHIELD SYSTEM OVER TREATED PLYWOOD SHEATHING 2x6 WOOD PURLINS @ 16" OC MAX 1x6 WOOD SOFFIT (3x) HEAVY TIMBER TRUSS, SEE STRUCTURAL 4 METAL STANDING SEAM ROOF SYSTEM 5/8" ICE & WATER SHIELD SYSTEM OVER TREATED PLYWOOD SHEATHING 2x6 WOOD PURLINS @ 16" OC, MAX 1x6 WOOD SOFFIT HEAVY TIMBER TRUSS RIDGE CAP CONTINUOUS BUTYL TAPE PERFORATED VENT STRIP 2x6 WOOD PURLINS @ 16" OC, MAX 5/8" ICE & WATER SHIELD SYSTEM OVER TREATED PLYWOOD SHEATHING ZEE CLOSURE W/ NON- CURING BUTYL SEALANT AT ENDS, FILL GAPS LOCK CLIP, SEE MANUFACTURER RECOMMENDATIONS FOR SPACING AND LOCATION METAL STANDING SEAM ROOF PANEL WOOD TRUSS WHERE APPLICABLE, SEE STRUCTURAL SIMPSON HURRICANE CLIPS W/ SS DRIVE FASTENERS @ EA RAFTER, TYP SIMPSON HURRICANE STRAP @ EACH RAFTER1x12 RIM BOARD CONTINUOUS PREFINISHED METAL DRIP EDGE PREFINISHED CONTINUOUS 6"x8" ALUMINUM GUTTER SYSTEM TO MATCH EXISTING 3/8" BEAD NON-CURING BUTYL SEALAND LOCK CLIP, SEE MANUFACTURER RECOMMENDATIONS FOR SPACING AND LOCATION 2x6 WOOD PURLINS @ 16" OC, MAX 5/8" ICE & WATER SHIELD SYSTEM OVER TREATED PLYWOOD SHEATHING METAL STANDING SEAM ROOF PANEL WOOD TRUSS WHERE APPLICABLE, SEE STRUCTURAL CONTINUOUS BUTYL TAPE 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:22 AMA-2 PROPOSED PORTE COCHERE REFLECTED CEILING PLAN & DETAILS 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 460320 2 4 8 NORTH TRUE NORTH PLAN SCALE: 1/4" = 1'-0"1 PORTE COCHERE - PROPOSED REFLECTED CEILING PLAN SCALE: 1" = 1'-0"2 COLUMN DETAIL SCALE: 1" = 1'-0"3 COLUMN SECTION SCALE: 3" = 1'-0"4 PRECAST STONE CAP DETAIL SCALE: 1 1/2" = 1'-0"6 PORTE COCHERE TRUSS SECTION SCALE: 1 1/2" = 1'-0"5 PORTE COCHERE ROOF ASSEMBLY DETAIL SCALE: 1 1/2" = 1'-0"8 RIDGE VENT DETAIL SCALE: 1 1/2" = 1'-0"7 EAVE DETAIL, TYP INFILL SKYLIGHT AT EXISTING ROOF BEYOND 2 A-3 _____ 12 8 RIDGE VENT A-2 5 A-2 7 NEW STANDING SEAM METAL ROOFING A B 1 A-3 _____ EXISTING BUILDING 1x6 PREFINISHED METAL ROOF RIDGE CAP METAL GUTTER SYSTEM BEYOND WOOD TRUSS, TYPRIDGE BEAM 123456 1 A-3 _____ NEW STANDING SEAM ROOF SYSTEM RIDGE VENT NEW METAL GUTTER SYSTEM, MATCH EXISTING NEW METAL DOWNSPOUT, MATCH EXISTING EXTERIOR WALL BEYOND NEW METAL DOWNSPOUT, MATCH EXISTING EXISTING BUILDING NOTE: EACH WOOD ELEMENT SHALL BE COATED W/ FIRE RETARDANT COATING SYSTEM PRIOR TO INSTALLATION. REFERENCE SHEETS IN THIS PACKAGE, TYP. 2 A-3 _____ EXTERIOR WALL BEYOND NEW METAL DOWNSPOUT, MATCH EXISTING NEW METAL GUTTER SYSTEM, MATCH EXITING EXTERIOR WALL BEYOND INFILL SKYLIGHT AT EXISTING ROOF BEYOND 12 8 RIDGE VENT NEW STANDING SEAM METAL ROOFING METAL FASCIA 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:11:28 AMA-3 PROPOSED PORTE COCHERE ELEVATIONS & SECTIONS 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032SCALE: 1/4" = 1'-0"1 PORTE COCHERE - PROPOSED E/W SECTION SCALE: 1/4" = 1'-0"2 PORTE COCHERE - PROPOSED N/S SECTION SCALE: 1/4" = 1'-0"3 PORTE COCHERE - PROPOSED EAST ELEVATION SCALE: 1/4" = 1'-0"4 PORTE COCHERE - PROPOSED SOUTH ELEVATION (2 / A-4)(3 / A-4)(3 / A-4)(4 / A-4) (3 / A-4) (2 / A-4)(4 / A-4) (3 / A-4) 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:13:53 AMA-4 EXTERIOR ELEVATIONS - EAST 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 46032SCALE: 1" = 20'-0"1 OVERALL EXTERIOR ELEVATION - EAST 0 2010 40 SCALE: 1/8" = 1'-0"2 EXTERIOR ELEVATION - EAST (1) 0 4 8 16 SCALE: 1/8" = 1'-0"3 EXTERIOR ELEVATION - EAST (2) SCALE: 1/8" = 1'-0"4 EXTERIOR ELEVATION - EAST (3) 0 4 8 16 0 4 8 16 (2 / A-5)(3 / A-5) (3 / A-5) (2 / A-5) 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:14:09 AMA-5 EXTERIOR ELEVATIONS - NORTH 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 460320 2010 40 0 4 8 16 0 4 8 16 SCALE: 1" = 20'-0"1 OVERALL EXTERIOR ELEVATION - NORTH SCALE: 1/8" = 1'-0"2 EXTERIOR ELEVATION - NORTH (1) SCALE: 1/8" = 1'-0"3 EXTERIOR ELEVATION - NORTH (2) (4 / A-6)(3 / A-6)(3 / A-6)(2 / A-6) (3 / A-6) (2 / A-4)(4 / A-4) (3 / A-4) 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:14:26 AMA-6 EXTERIOR ELEVATIONS - WEST 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 460320 2010 40 0 4 8 16 0 4 8 16 0 4 8 16 SCALE: 1" = 20'-0"1 OVERALL EXTERIOR ELEVATION - WEST SCALE: 1/8" = 1'-0"2 EXTERIOR ELEVATION - WEST (1) SCALE: 1/8" = 1'-0"3 EXTERIOR ELEVATION - WEST (2) SCALE: 1/8" = 1'-0"4 OVERALL EXTERIOR ELEVATION - WEST (3) (3 / A-7)(2 / A-7) (3 / A-7) (2 / A-7) 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM DATE: DRAWING TITLE: SHEET NUMBER: JOB NO.: ISSUE: #DATE: DESCRIPTION: CONTRACTOR TO VERIFY IN FIELD DIMENSIONS ON ALL DRAWINGS. ALL DIMENSIONS EXPRESS DESIGN INTENT AND ANY DISCREPANCIES FOUND IN FIELD OR IN THE DRAWINGS ARE TO BE BROUGHT TO ATTENTION OF OWNER OR KOHLER IMMEDIATELY. STAMP: A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 K 1 2 3 4 5 6 7 8 9 103/2/2023 10:14:43 AMA-7 EXTERIOR ELEVATIONS - SOUTH 22.020 10.05.2022 10.05.2022 Project StatusPORT COCHEREMAJESTIC CARE12999 PENNSYLVANIA STREETCARMEL, INDIANA 460320 2010 40 0 4 8 16 0 4 8 16 SCALE: 1" = 20'-0"1 EXTERIOR ELEVATION - SOUTH SCALE: 1/8" = 1'-0"2 EXTERIOR ELEVATION - SOUTH (1) SCALE: 1/8" = 1'-0"3 EXTERIOR ELEVATION - SOUTH (2) EXISTING METAL COPING, RE-PAINTED PAINT COLOR 1 - EXISTING BRICK SOLDIER COURSES EXISTING BRICK MASONRY FIELD COLOR EXISTING WINDOWS - PREVIOUSLY REFINISHED EXISTING MECHANICAL VENTS - PREVIOUSLY REFINISHED PAINT COLOR 2 - BASE MASONRY HALFWAY UP FIRST FLOOR WINDOWS METAL ROOF, GUTTERS AND DOWNSPOUT - COLOR 3 EXISTING SHUTTERS NEW CANOPY SYSTEM WOOD STRUCTURAL SYSTEM - FINISH TO MATCH BRICK FIELD FIELD STONE COLUMN BASE W/ PRECAST STONE TOPS OPTION 2 This Wall to be one solid color to match the 5th floor Color and will wrap around to the right side