HomeMy WebLinkAbout170309003_L600SITE DETAILSL600 Revision Date Description Date: Project No: Drawn by: Checked by:21-1513AY, SG, SSDTF2023-01-275825 Lawton Loop E. Dr. | Indianapolis, IN 46216
317-485-6900 | www.context-design.com
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
Permit Documents for the
PARKWOOD CROSSING VILLAGE GREEN
550 E 96th St, Indianapolis, IN 46280CONCRETE PAVEMENTNot to scale4,000 PSI Concrete Paving(Ref: Spec. 321316)Compacted Aggregate BaseVaries (See Plan Sheets)4"Compacted SubgradeNOTES:1.Provide expansion joints at intersection with another sidewalk, betweenwalks and building slabs, and at other points as indicated on the drawings.2.Refer to plan drawings for locations of control and expansion joints.3.Various Finishes and Colors. Refer to Site Materials Plan.Welded Wire Mesh, asRequired by SpecicationsFinish Grade4"CONCRETE PAVING JOINT DETAILS1 1/2" = 1'-0"Concrete Paving(Refer to Spec. 321316 for Fiber Reinforcement,if Applicable)Sawcut JointSawcut Joint w/ Beveled Edge as Shown(Cut Profile based on ProEdge Beveled Blade'XL-V25', or Approved Equal)Concrete Paving(Refer to Spec. 321316 for Fiber Reinforcement,if Applicable)Thickened Edge Concrete Paving(Refer to Spec. 321316 for Fiber Reinforcement,if Applicable)Tooled Expansion Joint w/ 1/4" Exposed EdgeRadius, and w/ Pre-formed Joint Material, Zip-strip,and SealantTooled Contraction Joint w/ 1/4" Exposed EdgeRadiusConcrete Paving(Refer to Spec. 321316 for Fiber Reinforcement,if Applicable)Thickened Edge Concrete Paving(Refer to Spec. 321316 for Fiber Reinforcement,if Applicable)Tooled Expansion Joint w/ 1/4" Exposed EdgeRadius, and w/ Pre-formed Joint Material, Zip-strip,and Sealant1/2"Ø X 12"L Smooth Dowel, 18" O.C.,Centered in Concrete PavingConcrete Paving(Refer to Spec. 321316 for Fiber Reinforcement,if Applicable)Tooled Expansion Joint w/ 1/4" Exposed EdgeRadius, and w/ Pre-formed Joint Material, Zip-strip,and Sealant1/2"Ø X 12"L Smooth Dowel, 18" O.C.,Centered in Concrete PavingDrill Hole 1/8" Larger than Joint Dowel Ø to AllowFree Movement of DowelDrill Hole 1/8" Larger than Joint Dowel Ø to AllowFree Movement of Dowel1/4"1/4"1"1"1/4"1"EXPANSION JOINT WITHIN PAVING:EXPANSION JOINT @ VERTICAL CONSTRUCTION (FOR BUILDING ENTRY):EXPANSION JOINT @ VERTICAL CONSTRUCTION (NOT @ BUILDING ENTRY):CONTRACTION JOINT - SAWCUT:CONTRACTION JOINT - DOUBLE SAWCUT:CONTRACTION JOINT - TOOLED:Building Face atBuilding Entry thatRequires Protectionfrom Frost Heave ofConcrete PavingBuilding Face,Structure, Column,and/or Wall notRequiring JointDowel for ControllingFrost Heave1/2"1/2"1/2"NOTE:Brush out trowel marks either side of joint and do notretrace tooled joint after broom finish.NOTE:Brush out trowel marks either side of joint and do notretrace tooled joint after broom finish.NOTE:Brush out trowel marks either side of joint and do notretrace tooled joint after broom finish.NOTE:Sawcut joint as soon as possible after concretehardens. Concrete is hard enough when the bladedoes not dislodge aggregate and when the edges ofthe cut do not ravel. Complete sawcutting beforeshrinkage becomes sufficient to produce cracking.NOTE:Sawcut joint as soon as possible after concretehardens. Concrete is hard enough when the bladedoes not dislodge aggregate and when the edges ofthe cut do not ravel. Complete sawcutting beforeshrinkage becomes sufficient to produce cracking.NOTE:Brush out trowel marks either side of joint and do notretrace tooled joint after broom finish.UNIT PAVERSScale: 3/4" = 1'-0"3/4" Bituminous Setting Bed.Pre-Manufactured Unit Paving Edge Restraint,3/16" X 1-5/8" 'Structuredge' by Permaloc, MillFinishWelded Wire Mesh.Pedestrian Pavers, Sand Swept Joints.Basis of Design: Holland Paver, by MutualMaterials. Refer to Materials Plans.Concrete Paving Slab w/ Thickened Edge forUnit Paving Substrate1" Weep Hole at 10'-0" O.C., Both Ways, Drilled.Filled with Compacted Sand.#53 Stone, Compacted.#2 Stone, Compacted.Undisturbed or Compacted Subgrade.Thickened Concrete Slab.Provide SS DoweledExpansion Joint4"
2"
4"Varies (See Plan Sheets)Finish Grade; Pile Height Extends1/2" Above Adjacent HardscapeSYNTHETIC TURF (@ PLANTING AREA & FLUSH CURB)Scale: 1-1/2" = 1'-0"Synthetic Turf Surfacing;Refer to Materials Plan for Productsand Turf LocationsPlanting AreaTurn Down Synthetic Turf Surfacing @ Planting Areas and Extend12" Below Aggregate Base. Pin w/ 6" Nails per Manufacturer Rec.2 x 6 Buried Nailer Board, Contractor Option on Final Board Materialper Manufacturer's Recommendation for Radial Perimeter Application.NOTES:1.Slope subgrade to positively drain to underdrain system.2.Refer to materials plan for synthetic turf surfacing basis-of-design products.3.Synthetic turf blanket seams shall run in same direction.Compacted Subgrade to 90% Standard ProctorNon-woven Filter FabricPerimeter Nailer Board at Flush Curb(and at all Hardscape Conditions),Anchor Perimeter Nailer to Flush Curbper Manufacturer's WrittenInstructions. Contractor Option onFinal Board Material w/ Approval fromOwner6"Full Depth Aggregate Base Layer(s) for SyntheticTurf Surfacing to be Designed and Specified byTurf Manufacturer / Design Build Contractor(6" min. Depth)See Note 16"Perforated Underdrain with Non-woven GeotextileWrap in Aggregate Drainage Trench.(Ref: Civil Dwgs. for Connections)See Note 1Adjacent Conditions Vary; PlantingArea, Concrete Paving, Unit Paving, orFlush Curb (Ref: Materials Plan)Cast-in-Place Concrete Curb, Flush w/Relative Finish Grade. Reinforce w/Synthetic Fibers per Specifications8"REPURPOSED GRANITE UNIT PAVERSScale: 1" = 1'-0"Salvaged Granite Unit Pavers, hand tight andsand swept jointsSand Setting BedNon-woven geotextile fabric for first 12"of perimeter, turn up at sidwalk edgeConcrete pavement(adjacent), Refer toDetail 1/L500Compacted stone base;Contractor to ensurepositive drainageCompacted Subbase1"
4 3/4"
4"4"316" x 1 58" aluminum edging at all edgesnot against a rigid pavement.SYNTHETIC TURF (@ EXISTING PAVEMENT)1"=1'-0"Adjacent Conditions Vary, VIF Applicable Adjacencies forNailer Installation. Existing Concrete Paving or Unit Paving.Consult w/ Turf Manufacturer on Nailer InstallationRecommendationsCompacted SubgradeSubbase Layers will VaryDepending on HardscapeMaterial, VIFSynthetic Turf Surfacing Nailer alongTurf Perimeter. Anchor to ExistingHardscape System perManufacturer's Written InstructionsSynthetic Turf Surfacing;Refer to Materials Plan for Productsand Turf LocationsFull Depth Aggregate Base Layer(s)for Synthetic Turf Surfacing to beDesigned and Specified by TurfManufacturer / Design BuildContractor1762345NOT USED8NOT USED1 03.24.2023 City Comments