HomeMy WebLinkAboutP-101 - BELOW SLAB PLUMBING PLAN1.2.3.4.COORDINATE INSTALLATION OF SANITARY PIPING WITH FOOTINGS IN THE FIELD. SLEEVE PENETRATIONS IN FOOTINGS WITH PVC.COMBINATION WASTE AND VENT SYSTEM SHOWN HERE. WHERE REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION, PROVIDE SAFE-WASTE SYSTEM OR DEDICATED VENT SYSTEM AS OUTLINED IN STATE AND LOCAL CODE AMENDMENTS.ALL WATER PIPING INSTALLED WITHIN EXTERIOR WALLS SHALL BE LOCATED ON THE INTERIOR SIDE OF THE INSULATION.ALL VENT PIPING TO BE 2'' DIAMETER MIN U.N.O. SEE 1/P-301 FOR VENT LAYOUT.5. SHEET NOTES3/4" CW TO SERVICE ROOM. SEE 1/P-101 FOR CONTINUATION.METHOD OF DRAINAGE AT REFUSE PAD -WHEN AREA DRAIN IS SHOWN ON CIVIL PLANS, SEE FIXTURE P-32 SPECIFICATION ON DRAWING P-901 FOR MAKE AND MODEL OF DRAIN. DRAIN AND PIPING PROVIDED AND INSTALLED BY CHICK-FIL-A SITE CONTRACTOR. WHEN AREA DRAIN IS NOT SHOWN, REFER TO ARCHITECTURAL DRAWINGS FOR DESIGN OPTION SHOWING DRAINAGE THROUGH BACK OF DUMPSTER ENCLOSURE.3/4" NON-FREEZE POST HYDRANT, P-31, WITHIN PVC SLEEVES. SECURE BARREL TO WALL WITH SPLIT-RING HANGER AND THREADED ROD 2'-0" AFF. SET BASE OF HYDRANT BARREL IN ONE CUBIC FOOT OF PEA GRAVEL. WRAP BASE OF HYDRANT WITH SILT FENCE FABRIC TO PREVENT DRAIN HOLE FROM BEING OBSTRUCTED.4" DIA SCHED 40 PVC SLEEVE. EXTEND THROUGH FOOTING. TERMINATE 1'-0" AFF. FILL WITH PEA GRAVEL. SECURE TO CMU WALL WITH SPLIT RING HANGER 0'-10" AFF.0' - 8"0' - 6"REFER TO SITE UTILITY PLAN FOR CONTINUATIONNO INTERIOR OR BELOW SLAB PLUMBING FORWARD OF THIS AREA.3'' VENT WITH WCO 12'' AFF.2'' CW. SEE 1/P-201 AND 4/P-303 FOR CONTINUATION.3/4'' CW TO REFUSE PAD. SEE DETAIL 3/P-101 AND 4/P-303.MAIN 2'' WATER SERVICE TO BUILDING:REFER TO SITE UTILITY PLAN FOR CONTINUATION. MATERIAL USED FOR WATER SERVICE OUTSIDE BUILDING SHALL BE TYPE K. FIRE SPRINKLER LINE. SPRINKLER PIPING SHOWN ONLY FOR REFERENCE AND COORDINATION OF SPRINKLER RISER LOCATION. COORDINATE INSTALLATION WITH FIRE SPRINKLER CONTRACTOR AND SITE UTILITY CONTRACTOR.KITCHEN EQUIPMENT NO. SEE KITCHEN EQUIPMENT SCHEDULE ON DWG P-303 FOR EQUIPMENT DESCRIPTIONS.XXX3" VENT3703053654" FCO,P-144" FCO,P-14P-10P-37P-13AP-35P-5P-10P-13BP-10P-6P-10P-5P-10P-10P-153" VENT3" FCO,P-143843804" FCO,P-14DININGSERVINGDRIVE-THRUWOMENSMENSRR VEST.KITCHENTEAM MEMBER ROOMSERVICEOFFICEFREEZERCOOLERP-26P-29BP-36P-263083803813" FCO,P-14P-54" FCO,P-14P-10P-10P-5P-13CP-37P-36 P-364" FCO,P-14P-5P-4BP-35P-2P-4BP-1P-2P-4BP-35P-4AP-4AP-2P-3P-35P-26P-12P-37P-364" FCO,P-143" WCO3" WCOP-26P-103939393931163939393939P-29AP-1039363H367P-35P-2639393" FCO,P-14P-1930REFER TO SITE UTILITY PLAN FOR CONTINUATION1-1/2'' CW IRRIGATION STUB OUT. SEE SITE UTILITY PLAN AND 4/P-303.P-1516TRANSITION TO 6" AT BUILDING EDGE. SEE SITE UTILITY PLAN.ENSURE COs WITHIN 3' OF BUILDING EDGE. SEE SITE UTILITY PLAN. TYPICAL.Chick-fil-A5200 Buffington Road Atlanta, Georgia 30349-2998Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives.CONSULTANT PROJECT #PRINTED FORDATESHEETSHEET NUMBERDRAWN BYREVISION SCHEDULEA1234BCDEABCDE1234CHICK-FIL-ABUILDING TYPE / SIZE:RELEASE:#3/1/2023 10:57:58 AMAutodesk Docs://IN_04978_West Carmel (IN) FSU_2022.7_FSR/04978_West Carmel (IN) FSU_PLB.rvtP-101BELOW SLAB PLUMBINGPLANPERMIT03/01/23CACWest Carmel FSU049789965 N MICHIGAN ROADCARMEL, IN 4603240-LS-04978-P-101-BELOW SLAB PLUMBING PLAN22169.CD.S22.08P14 LS LRGFSRNOT TO SCALE2GREASE INTERCEPTORKEY NOTES16 6'' DOUBLE CO, P-15. SEE DETAIL SHEET FOR CLEANOUTS OUTSIDE BUILDING.30 GREASE TRAP - REFER TO DETAIL 2/P-101, REFER TO SITE UTILITY PLAN SHEETFOR EXACT LOCATION.31 INSTALL FLOOR DRAIN P-35 AT MOP SINK DEPRESSION WITH TOP OF STRAINER 0'-7''BFF.39 PROVIDE TRAP SEAL PROTECTOR P-26A.1/4" = 1'-0"3REFUSE PAD PLUMBING PLANKurzynske & Associates2705 Lebanon Pike - Suite OneNashville, Tennessee 37214Telephone: (615) 255-52031/4" = 1'-0"1BELOW SLAB PLUMBING PLAN03/01/23NO.DATEDESCRIPTION2 03/03/2023 SANITARYREVISIONS222