HomeMy WebLinkAboutP-221 - SLAB ROUGH-IN PLANNOTE OF SPECIAL IMPORTANCE:BELOW-SLAB BEVERAGE CONDUIT SHALL BE 6'' DIAMETER SCHED 40 DWV SOLID WALL, NO FOAM CORE ALLOWED. USE LONG RADIUS ELBOWS (A.K.A. SWEEPS) ON ALL BEVERAGE CONDUIT. PLEASE NOTE BEVERAGE CONDUIT ROUGH-IN LOCATIONS ARE MEASURED TO THE FRACTION OF AN INCH. CARE MUST BE TAKEN WHEN INSTALLING 6" DIAMETER CONDUIT LOCATED WITHIN A 2X8 WALL. THE MARGIN FOR ERROR IS ONLY 1/16TH INCH.EXERCISE CAUTION WHEN LOCATING ROUGH-INS AT: -DRIVE THRU AREA -CUSTOMER WAIT AREADO NOT PULL TAPE FROM THE SLAB EDGE AT THESE AREAS WITHOUTCOMPENSATING FOR DIFFERENCE IN OFFSETS. NOTE OFFSET AT BACKCORNER OF BUILDING.IMPORTANT NOTE TO INSTALLERIMPORTANT: INSTALL FLOOR DRAIN WITH TOP OF DRAIN 0'-7'' BFF. COORDINATE WITH GENERAL CONTRACTOR. SEE ARCHITECTURAL AND STRUCTURAL DRAWINGS.MOP SINK NOTECOORDINATE LEGENDVENTX=43'8"Y=14'7"EXAMPLECWX=43'8"Y=14'7"#2TYPE#1APPLIES TO DWV PENETRATION ONLY.PIPE COORDINATESAPPLIES TO WATER PIPING ROUGH-INPENETRATION ONLY. SEE P-101 FOR CONTINUATION.6'' BEV CONDX=43'8"Y=27'3"#3APPLIES TO 6'' BEVERAGE CONDUIT PENETRATIONONLY.NOTES ABOUT (0,0) BENCHMARK ORIGIN1.2.3.THE (X=0, Y=0) BENCHMARK ORIGIN IS LOCATED AT THE OUTSIDE FACE OF FRAMING FOR THE EXTERIOR WALL AT THE CORNER WHERE SHOWN ON THE ADJACENT PLAN.IT IS EXTREMELY IMPORTANT FOR THE PLUMBING INSTALLER TO BECOME COMPLETELY FAMILIAR WITH THE FACE-OF-FRAMING POSITION AND ITS RELATION TO THE FLOOR SLAB CONSTRUCTION PRIOR TO BEGINNING THE UNDERSLAB PLUMBING ROUGH-IN.. PLUMBING CONTRACTOR SHALL REVIEW STRUCTURAL DETAIL ''TYPICAL SECTION @ EXTERIOR WALL'' FOR PRECISE LOCATION OF FACE-OF-FRAMING WITH RESPECT TO THE SLAB INSTALLATION PRIOR TO LOCATING SLAB ROUGH-INS.SEE MOP SINKNOTE THIS SHEETBENCHMARK ORIGIN FOR ROUGH-IN COORDINATES IS LOCATED AT OUTSIDE FACE OF FRAMING. SEE NOTES ON BENCHMARK ORIGIN THIS SHEET.(-X)+XNO INTERIOR OR BELOW SLAB PLUMBING TO FORWARD OF THIS AREA.P-37X=99' - 0"Y=11' - 5"P-14X=68' - 8"Y=1' - 9"P-10X=71' - 8"Y=5' - 3"P-37X=83' - 8"Y=24' - 0"P-14X=66' - 1"Y=24' - 3"P-13BX=17' - 3"Y=21' - 9"P-13AX=35' - 0"Y=26' - 10"P-35X=5' - 7"Y=19' - 4"P-5X=26' - 4"Y=28' - 5"P-26X=5' - 11"Y=11' - 10"P-12X=8' - 9"Y=21' - 3"P-10X=28' - 4"Y=14' - 11"P-10X=28' - 4"Y=5' - 10"P-10X=38' - 3"Y=23' - 1"P-10X=49' - 10"Y=23' - 1"P-6X=63' - 3"Y=19' - 2"P-10X=47' - 9"Y=5' - 10"VENTX=21' - 8"Y=0' - 2"2" CWX=0' - 10"Y=12' - 6"VENTX=0' - 3"Y=19' - 4"VENTX=0' - 3"Y=20' - 1"P-14X=23' - 0"Y=4' - 7"FIREX=1' - 9"Y=1' - 6"DININGSERVINGDRIVE-THRUWOMENSMENSRR VEST.KITCHENSERVICEOFFICEVESTIBULEFREEZERCOOLERP-5X=95' - 10"Y=1' - 2"P-26X=94' - 6"Y=10' - 9"P-29X=92' - 6"Y=12' - 11"P-36X=75' - 9"Y=-0' - 9"(-Y)VENTX=5' - 7"Y=21' - 1"P-10X=1' - 7"Y=16' - 0"P-29X=44' - 3"Y=25' - 0"P-26X=45' - 9"Y=27' - 1"TECH CLOSETP-5X=49' - 6"Y=0' - 2"P-10X=47' - 9"Y=12' - 11"P-14X=2' - 4"Y=5' - 9"3/4" CWX=0' - 10"Y=15' - 11"P-5X=51' - 4"Y=28' - 6"P-13CX=94' - 9"Y=3' - 1"VENTX=95' - 10"Y=9' - 4"P-36X=81' - 4"Y=11' - 1"P-14X=92' - 0"Y=3' - 1"P-36X=76' - 9"Y=11' - 1"P-36X=93' - 6"Y=22' - 6"P-37X=99' - 7"Y=24' - 10"P-35X=55' - 0"Y=32' - 4"P-14X=60' - 10"Y=30' - 9"VENTX=60' - 10"Y=36' - 7"P-4AX=57' - 4"Y=36' - 6"P-3X=53' - 9"Y=38' - 5"P-14X=43' - 4"Y=38' - 2"P-35X=40' - 10"Y=34' - 9"P-2X=60' - 10"Y=35' - 3"P-4BX=49' - 10"Y=28' - 6"P-2X=35' - 8"Y=30' - 3"VENTX=34' - 3"Y=30' - 3"VENTX=34' - 3"Y=34' - 9"VENTX=34' - 3"Y=35' - 11"P-1X=35' - 8"Y=35' - 11"P-4BX=34' - 2"Y=39' - 9"P-35X=30' - 10"Y=39' - 2"P-4BX=34' - 3"Y=36' - 10"VENTX=34' - 3"Y=40' - 9"VENTX=34' - 3"Y=41' - 10"P-26X=3' - 1"Y=6' - 9"P-26X=1' - 5"Y=11' - 0"P-14X=92' - 0"Y=16' - 6"P-2X=32' - 9"Y=41' - 10"P-10X=85' - 4"Y=14' - 2"WCOX=34' - 3"Y=29' - 3"WCOX=34' - 3"Y=42' - 11"P-10X=3' - 1"Y=1' - 9"VENTX=3' - 1"Y=0' - 3"VENTX=95' - 11"Y=23' - 2"P-35X=58' - 11"Y=38' - 8"VENTX=58' - 11"Y=36' - 6"P-14X=50' - 6"Y=4' - 7"P-14X=98' - 9"Y=9' - 4"IMPORTANT: INSTALL THE FLOOR FIXTURE SUCH THAT THE TOP-OF-RIM ELEVATION IS AS FOLLOWS:P-10P-35P-35P-36P-37FLOOR DRAINRESTROOM FLOOR DRAINMOP SINK DRAININDIRECT WASTE RECEIVERFLOOR DRAINFIXTURE TYPERIM ELEVATION1/2'' BFF1/4'' BFF7'' BFF1/4'' BFF1/4'' BFFNOTE: FIXTURE RIM/GRATE SHALL SET BE FLUSH WITHADJACENT FLOOR. SEE ARCHITECTURAL PLANS FORFLOOR SLOPE AT SLAB DEPRESSION FOR FIXTURESINSTALLED BELOW FINISHED FLOOR ELEVATION. FLOOR FIXTURES NOT LISTED HERE SHALL BE INSTALLED FLAT AND FLUSH WITH FINISHED FLOOR ELEVATION.FLOOR FIXTURE ELEVATIONSChick-fil-A5200 Buffington Road Atlanta, Georgia 30349-2998Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives.CONSULTANT PROJECT #PRINTED FORDATESHEETSHEET NUMBERDRAWN BYREVISION SCHEDULEA1234BCDEABCDE1234CHICK-FIL-ABUILDING TYPE / SIZE:RELEASE:#1/12/2023 11:07:49 AMAutodesk Docs://IN_04978_West Carmel (IN) FSU_2022.7_FSR/04978_West Carmel (IN) FSU_PLB.rvtP-221SLAB ROUGH-IN PLANPERMIT01/12/23CACWest Carmel FSU049789965 N MICHIGAN ROADCARMEL, IN 4603240-LS-04978-P-221-SLAB ROUGH-IN PLAN22169.CD.S22.08P14 LS LRGFSRKurzynske & Associates2705 Lebanon Pike - Suite OneNashville, Tennessee 37214Telephone: (615) 255-52031/4" = 1'-0"1SLAB ROUGH-IN PLAN01/12/23NO.DATEDESCRIPTION