HomeMy WebLinkAboutWestchester NC2GCZ
0.10
Northern Craftsman 2G
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 1796 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 2.39 2.99 2.97 48.69 7 0
AT EAVE 3.59 2.99 3.13 51.31 0 45.00
TOTAL (MIN)5.99 5.99 6.09 100.00
HIGH -
RIDGE VENT 2.39 2.99 2.75 45.21 0 0 22.00
AT EAVE 3.59 2.99 3.33 54.79 0 48.00
TOTAL (MIN)5.99 5.99 6.08 100.00
ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "B"SQ FTG 427 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.57 0.71 0.85 54.95 2 0
AT EAVE 0.85 0.71 0.69 45.05 0 10.00
TOTAL (MIN)1.42 1.42 1.54 100.00
HIGH -
RIDGE VENT 0.57 0.71 0.63 42.86 0 0 5.00
AT EAVE 0.85 0.71 0.83 57.14 0 12.00
TOTAL (MIN)1.42 1.42 1.46 100.00
ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE AMBLESIDE: Grids 4 Sides are Required per PUD ~ 26' - 0''3060 3060 3060 3060
2040
3053 3053 3053
4010
40104010
3053 3053 3053
2040
3050
3060
305330533053
9
12
9
12
9
12
9
12
9
12
9
12
4
12
NC2G
ELEVATION NC2G
ADDITIONAL 1ST FLOOR - HEATED 0
TOTAL 1ST FLOOR 1548
ADDITIONAL 2ND FLOOR - HEATED 31
TOTAL 2ND FLOOR 1783
TOTAL ELEV. HEATED 3331
ADDITIONAL GARAGE - 3 CAR FRONT 0
TOTAL GARAGE 640
ADDITIONAL BASEMENT 0
TOTAL BASEMENT 1448
FRONT PORCH 137
TOTAL ELEV. FOOTPRINT 2325
LIGHT & VENT SCHEDULE
ROOM NAME AREA
REQUIRED SUPPLIED
LIGHT VENT LIGHT VENT
LOFT 268.00 21.44 10.72
11.7 +
ARTIF.
5.0 +
MECH.
BEDROOM 4 171.00 13.68 6.84 23.4 10.0
FLEX 183.00 14.64 7.32 27.4 11.8
** REFER TO LIGHT & VENT SCHEDULE ON COVER SHT. FOR INFORMATION NOT
SHOWN HERE.
SCHEDULE of AREAS
BASE HOUSE - HEATED
FIRST FLOOR 1548
SECOND FLOOR 1752
TOTAL BASE HEATED 3300
BASE HOUSE - UNDER ROOF
GARAGE - 2 CAR FRONT ENTRY 640
BASEMENT 1448
TOTAL BASE UNDER ROOF 2188
BASE OPTIONS - HEATED
SUNROOM 144
REAR 4FT EXTENSION 69
SUNROOM W/ 4FT EXTENSION 196
CAFE BAY N/A
CAFE BAY 2 N/A
FINISHED BASEMENT OPTIONS
FINISHED BASEMENT 978
FINISHED BASEMENT BATH 55
FINISHED BASEMENT BEDROOM 128
ADDITIONAL AREA W/ SUNROOM 129
ADDITIONAL AREA w/ GATHERING ROOM
EXTENSION 58
ADD. AREA W/ SUNROOM & GATHERING
ROOM EXTENSION 191
ADDITIONAL AREA w/ CAFE BAY 2 N/A
MECHANICAL and STORAGE 470
BASE OPTIONS
BASEMENT / SUNROOM 1592
BASEMENT / GATHERING ROOM EXTENSION 1517
BASEMENT / SUNROOM/GATHERING ROOM
EXTENSION 1655
BASEMENT / CAFE BAY 2 N/A
COVERED PORCH N/A
SCREENED PORCH N/A
2 CAR SIDE ENTRY GARAGE 640
3 CAR FRONT ENTRY GARAGE 640
3 CAR SIDE ENTRY GARAGE N/A
2 CAR COURTYARD ENTRY N/A
BASEMENT =========================>>
-------------------------------------------------------------------------------------------------------------------
CRAWL =========================>>
N/A
N/A
WOOD DECK 144
CONCRETE PATIO 144
OTHER 0