HomeMy WebLinkAboutGreenfield NC2GCZ 0.10 05/15/23 Northern Craftsman 2G-B ATTIC VENT SCHEDULE ROOF AREA "A" SQ FTG 1720 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 2.29 2.87 2.54 43.78 6 0 AT EAVE 3.44 2.87 3.26 56.22 0 47.00 TOTAL (MIN)5.73 5.73 5.81 100.00 HIGH - RIDGE VENT 2.29 2.87 0.00 ######0 0 0.00 AT EAVE 3.44 2.87 0.00 ####0 0.00 TOTAL (MIN) 5.73 5.73 0.00 ###### ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "B" SQ FTG 250 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.33 0.42 0.42 46.56 1 0 AT EAVE 0.50 0.42 0.49 53.44 0 7.00 TOTAL (MIN)0.83 0.83 0.91 100.00 HIGH - RIDGE VENT 0.33 0.42 0.00 ####0 0 0.00 AT EAVE 0.50 0.42 0.00 ######0 0.00 TOTAL (MIN) 0.83 0.83 0.00 ###### ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE AMBLESIDE: Grids 4 Sides are Required per PUD ~ 26' - 11 3/4''3053 3053 2030 2030 3053 3053 3060 3060 30503050 3053 3053 4010 3053 3053 3053 3053 3060 3060 3060 3040 3060 2040 4010 2020 2020 NC2G 05/15/23 BASE HOUSE - HEATED FIRST FLOOR 1272 SECOND FLOOR 1749 TOTAL BASE HEATED 3021 BASE HOUSE - UNDER ROOF GARAGE - 2 CAR FRONT ENTRY 616 BASEMENT 1179 TOTAL BASE UNDER ROOF 1888 BASE OPTIONS - HEATED SUNROOM 144 REAR 4FT EXTENSION 73 SUNROOM W/ 4FT EXTENSION 216 CAFE BAY 20 CAFE BAY 2 40 FINISHED BASEMENT OPTIONS FINISHED BASEMENT 788 FINISHED BASEMENT BATH 44 FINISHED BASEMENT BEDROOM 141 ADDITIONAL AREA W/ SUNROOM 129 ADDITIONAL AREA W/ 4FT EXTENSION 68 ADD. AREA W/ SUNROOM & 4FT EXT 201 ADDITIONAL AREA W/ CAFE BAY 2 36 ADDITIONAL AREA W/ OTHER 0 MECHANICAL and STORAGE 391 BASE OPTIONS BASEMENT / SUNROOM 1308 BASEMENT / 4' EXTENSION 1247 BASEMENT / SUNROOM/4 FT EXTENSION 1380 BASEMENT / CAFE BAY 2 1215 COVERED PORCH 144 SCREENED PORCH 144 2 CAR SIDE ENTRY GARAGE 646 3 CAR FRONT ENTRY GARAGE 616 3 CAR SIDE ENTRY GARAGE 0 2 CAR COURTYARD ENTRY 0 BASEMENT ------------------------------------------------------------------------------------------------------------------------------ --- CRAWL 923 256 WOOD DECK 158 CONCRETE PATIO 144 OTHER 0 ELEVATION NC2G-B 0 TOTAL 1ST FLOOR 1272 -45 TOTAL 2ND FLOOR 1704 TOTAL ELEV. HEATED 2976 40 TOTAL GARAGE 656 ADDITIONAL BASEMENT 0 TOTAL BASEMENT 1179 FRONT PORCH 128 2056 LIGHT & VENT SCHEDULE ROOM NAME AREA REQUIRED SUPPLIED LIGHT VENT LIGHT VENT BEDROOM 2 176.70 14.14 7.07 15.70 5.00 GAME ROOM 360.17 28.81 14.41 ** REFER TO LIGHT & VENT SCHEDULE ON COVER SHT. FOR INFORMATION NOT SHOWN HERE. 05/15/23