Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A102B 2nd Floor Plan-Area B
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC 2nd Floor Plan- Area B THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A102B CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 2/3/23 Carmel Review Thursday, March 30, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSENOT FORCONSTRUCTION1 2 3 4 5 6 7 8 UP123456789 12345678UP12345678UP12345678912345678UP 1 2 3 4 5 6 7 8 9 NNC1 A415 C1 A414 D2 A407 B3 A507 B3 A507 B3 A507 B3 A507 G7.9 G4 G8 G7.5 G7 G2.3 G1 G5 G3 G2 G6 G6.7 GE GCGB GG GA.9 G.9A G7.6 G1.5 GF GH GI G1.1 GA GJ A4 A317 A2 A317 B2 A203 B1 A304 B2 A304 B3 A304 E3 A303 A2 A308 B1 A206 A1 A206 A1 A207 A3 A205 A3 A221 #DrgID #LayID C1 A413 C415'-5 1/2"10'-8 5/8"10'-8 7/8"83'-3"10'-9"10'-8 5/8"14'-7 3/4"7 5/8"15'-8"4'-1"7'-11 7/8"7'-11 5/8"3'-9"8'-7 1/4"7'-0 1/8"3'-9"7'-5"4'-8" 12'-0"3/4"12'-0" 1'-9" 12'-0 3/4"6'-0"8'-6"8'-6"8'-6"6'-8 1/4"8'-6"8'-6"8'-6"8'-6"2'-10 1/2"18'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"4'-5 5/8"18'-0"1'-0 1/4"1'-2 5/8"R 24'-0"R 2 4 ' - 0 " R 2 4 ' - 0 " #DrgID #LayID 240206207208209210211212202203201206A208A209A210A207A211A212A2ST32ST4 2422ST1 2ST2A W6Bi W6Bi W6Bi W6Bi W6Di W6Di W4Hi S5Hi W6Bi S5Hi S5Hi S5Hi W6Di W6Di W6Di W4Hi W6Di W4Hi W6Di W6Di W6Di W4Hi W4Mi W4Hi W6Bi W4Hi W6Di W6Di W6Di W6Di W6Bi W6Di W6Bi W6Fi W6Ai W4Ai W6Fi W6Bi W6Bi W4Hi S5Hi S5Hi M8 M8 M8 W6Bi M8 M8 M8 M8 W6Fi M8 M8 M8 M8 W1.5A W4Ai W6Fi2ST3A 2ST225 15 2424 24 24 24 24 32 24 13 13 13 13 KP KP KP KP 13 13 13 13 27 27 27 27 27 2ST1A241244B244A245 28 28 2828 2828 7 232 13 M8 M8 M8 M8 M8 13 13 13 M8 BRK 2 M82ST4A 24 S5Hi W4A W4A 11 1111 13 13 26 1 1 1 1 1 1 1 11 11 11 11 1 1 1 1 1 1 1 1 1 1 SF35SF35 SF35 SF36 SF37 33 26 26 26 26 26 MATCH LINE MATCH LINE FLOOR PLANAREA BFLOOR PLANAREA AMATCH LINE MATCH LINE FLOOR PLANAREA CFLOOR PLANAREA BRAMP UPRAMP DNFEC FEC Shaft 243 Trash 245 A:105 NA:105 Corridor 233 A:1,448 NA:1,448 IDF242A:33Stair STR3 A:201 NA:165 Stair STR2 A:201 NA:165 Stair STR1 A:205 NA:205 Stair STR4 A:227 NA:187 Apartment Type A4 210 A:785 PA:756 Apartment Type A4 209 A:788 PA:760 Apartment Type A4 208 A:788 PA:761 Apartment Type A4 207 A:782 PA:759 Apartment Type B5 206 A:963 PA:941 Elev. Lobby 241 A:189 NA:189 Trash Room 240 A:50 NA:44 Chute 50 Parking Garage 200 A:25,511 NA:25,511 Corridor 232 A:1,692 NA:1,692 Corridor 230 A:966 NA:966 Service Elev. 51 Public Elev. 52 Res. Elev. 53 Res. Elev. 54 Apartment Type A4 212 A:783 PA:759 Apartment Type A4 211 A:785 PA:756 Elev. Lobby 244B A:109 NA:109 Elev. Lobby 244A A:98 NA:98 B2 A415 A4 A308 KPKP11 A3 A308 SF37 A1 A307 A1 A306 A2 A306 A3 A306 123456789D1 A410 C2 A503 D1 A503 D1 A503 D1 A503 B2 A503 B2 C1 A503 C1 A503 B2 A503 D1 A503 A2 A503 E1 A407 30'-1 1/8"22'-9 3/8"25'-5 1/2"22'-9 1/4"25'-5 1/2"22'-9 3/8"25'-4 3/8"10'-10 7/8"12'-4"8'-5"5 1/2"3'-7 5/8"5'-3 7/8"2'-5 1/4"2'-4 7/8"5'-4 1/4"3'-7 1/2"5 1/2"6'-2 3/8"12'-4"6'-0 1/4"5 1/2"3'-7 5/8"5'-3 7/8"2'-5 1/4"2'-5 3/8"5'-3 3/4"3'-7 1/2"5 1/2"6'-2 1/4"12'-4"6'-0 1/4"5 1/2"9'-0 3/8"2'-4 3/8"2'-6 1/4"8'-10 3/8"5 1/2"6'-0 1/4"12'-4"6'-1 1/8"5 1/2"2'-3"5'-1 3/8"3'-6 1/2"5 1/2"9'-4 5/8"157'-6 7/8"8'-9"8"156'-3 1/4"7 5/8"3'-1 1/2"8 7/8"23'-4 1/4"8 7/8"23'-3 3/4"10 1/2"23'-3 3/4"24'-1 3/8"8 7/8"23'-4 5/8"8 7/8"8 7/8"23'-4 1/4"11'-10 1/2"11'-5 3/4"11'-5 3/4"11'-5 3/4"8 7/8"11'-5 3/4"11'-5 3/4"11'-5 3/4"11'-10 1/2"16'-6 3/4"11'-4 3/8"11'-10"6'-10"34'-4"6'-10 5/8"2'-0 7/8"4'-7 1/8"5'-9 3/4"18'-3 5/8"46'-9 3/4"14'-8 7/8"20'-11 1/8"24'-9 1/2"7'-1" 2'-2 3/8"4'-4 1/4"8'-9 7/8"11'-2 3/8"26'-8 1/4"9'-2 1/4"39'-0 1/4"9'-2 1/2"38'-7 3/8"9'-7 1/8"19'-7 1/4"10'-7 3/8"11'-5 5/8"18'-5 5/8"5'-7 1/2"7'-11 5/8" 8'-6 3/4"3'-0 7/8"24'-8 3/4"52'-1 1/2"3'-7 3/4"3'-7 3/4"51'-0 1/4"26'-4"2'-3 1/2"5 1/2"10'-10 7/8"5 1/2"24'-5 3/8"5 1/2"11'-4 5/8"11'-4 5/8"5 1/2"24'-6 1/2"5 1/2"11'-4 5/8"11'-4 5/8"5 1/2"24'-6 1/2"5 1/2"11'-4 5/8"11'-4 5/8"5 1/2"29'-2 1/8"KP KP Chute 51 GENERAL PLAN NOTES: 1. Dimensions are to face of studs unless noted otherwise. 2. Dimensions at Storefront are to inside of studs. See any Enlarged Details and Storefront Details, showing dimensions to masonry openings and face of returning exterior sheathing. 3. All gypsum board at the interior side of “Commercial” rooms are not included in this Bid Set, U.N.O.. 4. Refer to sheets A120 - A130 for interior layout of apartments and details. 5. See shaft sheet #LayID(ref) for enlarged drawings and dimensional clarifications. 6. Dimensions at door and window openings are to center of openings, U.N.O. 7. Spray all steel used for canopy and balcony attachment with SFRM (Spray-Applied Fire Resistive Material). Three hour for any 3rd floor locations and two hour for above 2nd floor. 8. Batt insulation (rock wool) are required inside CFS box headers and cripple studs. 9. Wall Types and interior wall layout are the same on the 2nd, 3rd, 4th, and 5th floors, UNO. 10. All walls are to deck above, at 1st and 2nd floors, UNO. Review all interior wall sections. 11. At all demising walls and corridor walls with additional furring indicated for plumbing and other rough-ins, continuation of the Corridor and Demising Wall type is implied in the drawings. Pre-rock of a hidden area will be required to accomplish the complete wall type and meet the code required fire barriers, regardless of the framing and sheeting sequence of work. 12. See sheets A510-A523 for balcony types and details. 13. For 3rd, 4th, and 5th floor plans see 2nd floor sheets (A102A - A102C) for dimensions, notes and detail markers pertaining to floors 3, 4 and 5, unless noted otherwise. All items shown on the 2nd floor applies to the 3rd and 4th floor, except for low roof. 14. All stairs are metal stair assemblies. Reference sheets starting with sheet A410. 15. Typical demising wall for apartment levels is A1/A306 16. All formed concrete stairs require embedded steel nosings like Wooster Products Type 241BF. FLOOR PLAN NOTES: 1 At commercial spaces, the concrete slab will be future. Only provide and install the compacted granular fill per the soils report to FINISH FLOOR elevation minus SLAB THICKNESS for the first floor. 2 Coordinate rough opening for doors in wall construction above CIP wall where special forming is required. 3 Horizontal bicycle racks, space 2'-10" on center. 4 Steel Stair: All steel platform, steel treads, open risers, with 42" high guardrail. Finish: Hot galvanized. Round railings and guardrails using horizontals 6" apart. Either core drill or bracket with bolts the vertical support members into the 6" concrete slab. 5 Meter locations, refer to E-Series sheets. 6 Knox box 7 Vertical bicycle racks. 8 Garage slab painted, car parking striping, handicapped symbols, and directional indicators. Striping 4" wide. 9 Mech, units above, refer to M-Series sheets. 10 Use mold and very high impact resistant gypsum sheathing board at the interior side of elevator lobbies for walls and ceilings. 11 Steel handrails required at ramps & stairs. See typical details on sheet A501 12 Stairs - Ref. S-Series Drawings 13 4'-0" high, 6" diameter concrete filled bollard painted yellow. 14 At commercial spaces, provide vapor retarder and batt insulation penetrations. 18 Mailboxes. Frame opening in wall for recessed Mailboxes with CFS header or bulkhead above. Provide substrate as required. Fire retardant wood if wood is used. Reference interior elevation. 19 Semi-recessed 1-HR rated fire extinguisher cabinet and extinguisher. 20 Corner bumper guard, typical at all outside corners, unless otherwise noted. Reference detail C3/A503. At corners adjacent to apartment entry doors, not in proximity of an elevator or stair, the smaller specified guard is to be applied. 21 Control Joints in Corridor Walls see details and dimensions on sheet A507. 22 Vent stacks, reference P-Series drawings. 23 Roof drains, reference P-Series drawings. 24 Floor to wall expansion joints: A504. 25 Steel balcony assembly attached to structural steel tube outriggers. Reference sheets A501, A510-A523 and S-Series drawings. 26 Interior chase wall for roof drain plumbing. Reference Detail B3/A507. 27 Surface mounted fire extinguisher cabinet and extinguisher. 28 Down spout guards. Ref. C1/A502 29 Future wall/partition or door. Provided by unit price. 30 Align wall (finished sheathing) to face of column 31 Bike Maintenance Station. 32 FRP panels 4'-0" high over 33 Align face of CMU wall with face of column. 34 Ornamental metal guardrailing. FLOOR PLAN NOTES: 1 At commercial spaces, the concrete slab will be future. Only provide and install thecompacted granular fill per the soils report to FINISH FLOOR elevation minusSLAB THICKNESS for the first floor. 2 Coordinate rough opening for doors in wall construction above CIP wall wherespecial forming is required. 3 Horizontal bicycle racks, space 2'-10" on center. 4 Steel Stair: All steel platform, steel treads, open risers, with 42" high guardrail.Finish: Hot galvanized. Round railings and guardrails using horizontals 6" apart.Either core drill or bracket with bolts the vertical support members into the 6"concrete slab. 5 Meter locations, refer to E-Series sheets. 6 Knox box 7 Vertical bicycle racks. 8 Garage slab painted, car parking striping, handicapped symbols, and directionalindicators. Striping 4" wide. 9 Mech, units above, refer to M-Series sheets. 10 Use mold and very high impact resistant gypsum sheathing board at the interior side of elevator lobbies for walls and ceilings. 11 Steel handrails required at ramps & stairs. See typical details on sheet A501 12 Stairs - Ref. S-Series Drawings 13 4'-0" high, 6" diameter concrete filled bollard painted yellow. 14 At commercial spaces, provide vapor retarder and batt insulation penetrations. 18 Mailboxes. Frame opening in wall for recessed Mailboxes with CFS header or bulkhead above. Provide substrate as required. Fire retardant wood if wood is used. Reference interior elevation. 19 Semi-recessed 1-HR rated fire extinguisher cabinet and extinguisher. 20 Corner bumper guard, typical at all outside corners, unless otherwise noted. Reference detail C3/A503. At corners adjacent to apartment entry doors, not in proximity of an elevator or stair, the smaller specified guard is to be applied. 21 Control Joints in Corridor Walls see details and dimensions on sheet A507. 22 Vent stacks, reference P-Series drawings. 23 Roof drains, reference P-Series drawings. 24 Floor to wall expansion joints: A504. 25 Steel balcony assembly attached to structural steel tube outriggers. Reference sheets A501, A510-A523 and S-Series drawings. 26 Interior chase wall for roof drain plumbing. Reference Detail B3/A507. 27 Surface mounted fire extinguisher cabinet and extinguisher. 28 Down spout guards. Ref. C1/A502 29 Future wall/partition or door. Provided by unit price. 30 Align wall (finished sheathing) to face of column 31 Bike Maintenance Station. 32 FRP panels 4'-0" high over 33 Align face of CMU wall with face of column. 34 Ornamental metal guardrailing. FLOOR PLAN NOTES: 1 At commercial spaces, the concrete slab will be future. Only provide and install thecompacted granular fill per the soils report to FINISH FLOOR elevation minusSLAB THICKNESS for the first floor. 2 Coordinate rough opening for doors in wall construction above CIP wall wherespecial forming is required. 3 Horizontal bicycle racks, space 2'-10" on center. 4 Steel Stair: All steel platform, steel treads, open risers, with 42" high guardrail.Finish: Hot galvanized. Round railings and guardrails using horizontals 6" apart.Either core drill or bracket with bolts the vertical support members into the 6"concrete slab. 5 Meter locations, refer to E-Series sheets. 6 Knox box 7 Vertical bicycle racks. 8 Garage slab painted, car parking striping, handicapped symbols, and directionalindicators. Striping 4" wide. 9 Mech, units above, refer to M-Series sheets.10 Use mold and very high impact resistant gypsum sheathing board at the interiorside of elevator lobbies for walls and ceilings.11 Steel handrails required at ramps & stairs. See typical details on sheet A50112 Stairs - Ref. S-Series Drawings13 4'-0" high, 6" diameter concrete filled bollard painted yellow.14 At commercial spaces, provide vapor retarder and batt insulation penetrations.18 Mailboxes. Frame opening in wall for recessed Mailboxes with CFS header orbulkhead above. Provide substrate as required. Fire retardant wood if wood isused. Reference interior elevation.19 Semi-recessed 1-HR rated fire extinguisher cabinet and extinguisher.20 Corner bumper guard, typical at all outside corners, unless otherwise noted.Reference detail C3/A503. At corners adjacent to apartment entry doors, not inproximity of an elevator or stair, the smaller specified guard is to be applied.21 Control Joints in Corridor Walls see details and dimensions on sheet A507.22 Vent stacks, reference P-Series drawings.23 Roof drains, reference P-Series drawings.24 Floor to wall expansion joints: A504.25 Steel balcony assembly attached to structural steel tube outriggers. Referencesheets A501, A510-A523 and S-Series drawings. 26 Interior chase wall for roof drain plumbing. Reference Detail B3/A507. 27 Surface mounted fire extinguisher cabinet and extinguisher. 28 Down spout guards. Ref. C1/A502 29 Future wall/partition or door. Provided by unit price. 30 Align wall (finished sheathing) to face of column 31 Bike Maintenance Station. 32 FRP panels 4'-0" high over 33 Align face of CMU wall with face of column. 34 Ornamental metal guardrailing. SCALE: 1/8" = 1'-0" 1 2nd Floor Plan-Area B A102B 0 4'8'16' G001 Title Sheet.pdf