HomeMy WebLinkAbout06080140 Site Plan
~.,
Schneider
The Scbneider Corporation
8901 QUI Avenue
Historic Fon Harrison
IndianllpollB. Indiana 46216-1037
317-626-7100
317-626-7200 FAX
Engineering
SUrveying
Landscape Architecture
GIS.IJS
Geology
This Plot Plan Prepared For: Beazer Homes
Lot # 1082,BLOCK "K"
The Village of West cloy
Section # 6001
INSTR. # 200500080672
PC 3, SUOE 790
Homiiton County, Cloy Township
See 29, T18N, R03E
12785 FORSYTH STREET (50' R/W)
Carmel, IN 46032
Prepared Date: 07/20/06: By: KAG
Community Restrictions:
Side Yard = 5' MIN (ONE SIDE)
Rear Yard = N/A
Aggregate = 20r. LOT !.lOlli, MiN. 5" ONE SIDE
Plot Plan Legend
1000.0 I Proposed Grades
000.0 Existing Grodes
_000.0-- Contour Grade
* Approx. lateral Location
- . - Sanitary Sewer lines
-11'- Storm Sewer Lines
- lJ - Waler Service Lines
- - - - - - - Sub-Surface Drain Lines
. Manhole (Sanitary or Storm)
. - Beehive Inlet (Storm)
IIIlI Curb Inlet (Storm)
D End Section (Storm)
..a. Fire Hydrant
- 0 0 0 _ 0 0 0 - Flow Line of swale
- Building Line (BL / BSL)
- - - - - - - Easement Line
Note:
The contractor is to maintain a minimum
distance of ten feet (10') between the
sanitary sewer and water line laterals.
Finished Floor Elevation Information
Pad Grade = 906.4 per plan
Edge of Pavement (E.O.P.) = 910.7 ( highpaint )
E.O.P, + 0.2' = Garage FFE (910.9)
Garage FFE + 0.67' = Residential FFE (911.6
Note: Sanitary Sewer
Top of Costing Information
Upstream Manhoie, TC= 908.62
Downstream Manhole, TC= 908.55
Per Record
I l-
I
I W
I W
I 0::::
I I
I l-
I c.n
I
:r::
I l-
I >--
I: c.n
0::::
I 0
l..L I
I
I
..
PER
29.0'
B-B
10.5'
PER PLAN
29.0'
B-6
10.5'
PER PLAN
!2~-:~:: a :;:
~~".l<~ !2
47.05' ~ 20.00
r :;: <l ~?6
p:~~~s: !2
'll _~_ ~ a ~
o~~:;:_ ,.
~ ~~~~ l:!i
.CJ>'" 45.0'
8
17.. L~n'
~
~
~ !! >
~I I
FLOOD HAZARD STATEMENT
CERllFICA 1l0N
,,\\\\\\\\\1111111/1/1/11/1.
&"~c:. L /l'~
~ ~"':) . vPv.; ~
~~'\ ......"......,/r,~~
~ ..' \ST€'.e.... ~
~.c.~ ......0 '-re-" /O~
;:::: <:::::)",..,<c-v No C/',.;<:>~
i ( 50303 \ i
? .... STATE OF.. ~
~ /.... ....<:\ tf
~ (.1,: '<,y01 A"!:'" \::i':'~
% '11J "S""U"R",i \'. -.l\ #'
~/j, "4"'",,#
1//f11/1/1I11I11\\\\\\\\\\~
~l.W()
This drawing IS not intet: to ~e :epresented os a retrocement or
original boundary survey. a route survey, or a Surveyor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of
Carmel, Indiana dated February 19, 2003.
Note:
This drawing is based on construction plans or record
drawings. and is not based upon a field survey. The
Schneider Corporation does not warrant th:e accuracy
or sufficiency of this information. Contractors should
verify existing conditions prior to any construction.
Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately.
failing to do so results in the contractorslassumption
of all liability. '
Note: Per Carmel zoning ordinance 26.1.1 : The
residential district limits height to twenty-five feet
(25'). however a dwelling may be increased in height
to thirty-five reet (35') pra~ded the side and rear
yards are increased on additional one foot (1') for
each one foot (1') the struelure exceeds the first
twenty-five feet (25') in height.
LOT # 1082
VB # 06.058388
o
~
=~=
o
~
TYPICAL SWALE SECTION
Assumed North
o 10 20
~ ~ I
SCALE I" . 20'
STR.# 141
TC=908.62
PER RECORD
DRA'MNG
STR.# 140
TC=908.55
PER RECORD
ORA\\1NG