Loading...
HomeMy WebLinkAbout06080142 Site Plan <~ .." Schneider The Schneider Corporation 8901 Otis Avenue Historic Fort. Harrison Indianapolis, Indiana 46216-1037 317-828-7100 317-828-7200 fAX Engineering Sun.Jln& Landscape Architecture GIS .lJS Geolo&y This Plot Plan Prepared For: Beozer Homes Lot # 1084, BLOCK "K" The Village of Westcloy Section # 6001 INSm. # 200500080672 PC 3, SUDE 790 Hamilton County , Clay Township See 29, T18N, R03E 128'09 FORSYTH STREET (50' R/WJ Carmel, IN 46032 Prepared Date: 07/20/06: By: KAG Community Restrictions: Side Yard = 5' MIN (ONE SIDE) Rear Yard = N/A Aggregat. = 20X LOT \\10TH, MIN. 5' ONE SIDE Note: The contractor Is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water line loterals. Finished Floor Elevation Information Pad Grade = 906.4 per plan Edge of Pavement (E.O.P.) = 910,7 ( highpoint ) E.O,P. + 0.2' = Garage FFE ( 910,9) Garage FFE + 0.67' = Residential FFE (911.6 ) Plat Plan legend [jjQ[[J Proposed Grades 000.0 Existing Grodes _000.0-- Contour Grade * Approx. Lateral location - . - Sanitary Sewer Lines -R- Storm Sewer Lines - 'W - Water Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) . _ _ Beehive Inlet (Storm) IIIB Curb Inlet (Storm) D End Section (Storm) ..... Fire H}':Irant - 000 _ 000 - Flow line of swole - Building line (BL / BSL) - - - - - - - Easement Line Note: Sanitary Sewer Tap of Casting Infanmatian Upstream Manhole, TC= 908.62 Downstream Manhole, TC= 908.55 Per Record I- '" w 1 ~ w ,. a PER f,;;j a:::: I ~ G; N I- :>~ !t U) 47.05' 29.0' '" in ~ B-B l' ... i!;, ~ ::r: m~~~~ I- ~ 14.0'1 88.00' 'li I ~ ~~-::il~ & >- I 0-1.00' ~~'1." U) I tx I e;;;; 1.00' lo.s' I 49.0" a:::: PER PLAN ;gi=:!~ --i:n1.00' I 0 I ~QJ e"'"i ~::IC::;;;:~ LL ." FLOOD HAZARD STATEMENT CERllFICA 1l0N "\\\\\\\\\Ilillllll/I/III/f, ~\\"ic. L f1 ~~ ~.,:,,':;) . V:"h~ ~ ~ ~ "................./r (/,,/../0- ~ <..~...~G\S TEIyi-......'-"....<>% "'ic--."..<<- No 0.. A'" ~ ---J/ . ..../""% I ( 50303 ) I % ':.... STATE OF ./ iff ~ /'. .' ~ ~ (" ~"...!.tyOI A~.!:"""~~ % ~ 'S"'U"'O\I\."-'-># ~4/, 1\' ':\# ~//IiIIiIIlIIiII1\\I\I\\\\' ~l.W() This drawing is not intet: to ~e :epresented as a retracement or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainly and 10 any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of Carmel, Indiana dated February 19, 2003. Nate: This drawing is based on construction pfa~s or record drawings, and is not based upon a field survey. The Schneider . Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found an this drawing should be reported to The Schneider Corporation immediately. failing to do so results in the contractors assumption of all liability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') pra~ded the side and rear yards are increosed an additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. LOT#-1084 VB # 06.0058390 ~ ~ =101= ~ . s ~I scO\'< ~ TYPICAL SWALE SEC110N Assumed North o 10 20 I I I SCALE I" = 20' STR.H 141 TC=90B.62 PER RECORD ORA\\1NG ' STR.H 140 TC=90B.55 PER RECORD DRA\\1NG