HomeMy WebLinkAbout06080143 Site Plan
-'
'--,
Schneider
The Schneider Corporation
6g01 008 Avenue
HiBlorio Fort Hamrroo
Indianapolis. IndlllI18. 48218-103'1
317-626-7100
317-626-7200 FAX
This Plot Pion Prepored For: Beozer Homes
Lot # 1085, BLOCK "K"
The Villoge of Westcloy
Section # 6001
INSTR. # 200500080672
PC 3, SLlOE 790
Homilton County, Cloy Township
See 29, T18N, R03E
12815 FORSYTH STREET ~O' R/W)
Cormel,-IN --46032
Prepared Date: 07/20/06: By: KAG
Community Restrictions:
Side Yard = S' MIN (ONE SIDE)
Rear Yard = N/~
Aggregate = 20r. LOT \\lOTH, MIN. 5' ONE SIDE
Zoning = SI
Note;
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sonitary sewer and water line laterals.
Finished Floor Elevation Information
Pad Grade = 906.4 per plan
Edge of Pavement (LO.P.) = 910.7 ( highpoin! )
E.O.P. + 0.2' = Garage FFE ( 910.9)
Garage FFE + 0.67' = Residential FFE (911.6
Engineerina
SurveJlng
Landscape Arclrlleeture
CIS .IJS
Geology
Plat Pian legend
I]Q[[J Proposed Grades
000.0 Existing Grades
__ 000.0-- Contour Grode
* Approx. Lateral Location
- . - Sanitary Sewer Lines
-" - Storm Sewer Lines
- 'W - Waler Service Lines
- - - - - - - Sub-Surface Drain Lines
. Manhole (Sanitary or Storm)
. Beehive Inlet (Storm)
-1IlII -Curb-inlet (Storm)
o End Section (Storm)
.... Fire Hydrant
- " " " - " " 0 _ Flow Line of swale
- Building Une (Bl / BSL)
- - - - - - - Easement Line
Note: Sanitary Sewer
Tap of Casting Information
Upstream Manhole. TC= 908.62
Downstream Manhole, TC= 90B.55
Per Record
Nate:
This drawing is based on construction p'lans or record
drawings. and is not based upon 0 field survey. The
Schneider Corporation does not warrant Ithe accuracy
or sufficiency of this information. Contr6ctors should
verify existing conditions prior to any construction.
Any discrepancy found an this drawing should be
reported to The Schneider Corporation immediately.
foiling to do so results in the contractors assumption
of all liability.
Note: Per Carmel zoning ordinance 26.1.1 : The
residential district limits height to twenty-five reet
(25'). however a dwelling may be Increased in height
to thirty-five feet (35') provided the side and rear
yards are Increased an additional one foot (1') far
each one foot (1') the structure exceeds the first
twenty-'five feet (25') in height.
LOT # 1085
VB #.06.0058391
~
~
=~=
~
Assumed North
o 10 20
I J I
SCAlE 1" = 20'
Note: Builder to ensure positive
drainage away from structure(s).
~
TYPICAL SWALE SECTION
" " " " " "
.1
CONGRESS STREET
29.C' (909.09) ,-
~ B-B H
ROll CURB ' PER
~ >
FLOOD HAZARD STATEMENT
CERTiFICATION
~\IIIIII\I\IIIIIIIII/fllll/,
#"~<: L /l ~"'~
~~':J . IJ/J/,~
#~~~>;:'.'\S'T"ii?'{:'V.{..-~
~ ..~.."u N ... .."".""", ~
~~ ..,~v 0 O"';o~
~~/ ".... %
~ l S0303 \ ~
~ . . ~
% \. STATE OF..... If
?: /". ,.' [f!
~ ~ ~ ....(,IVOI A\'\!":.... ~~
~ '#; ..S....U..R..,i I: ~ #
~ij/, , \. ~~~
~IIIIIIIIIIIIIIII\\\\\\\\\\
Oc-lrv
I-
W
w
0::::
l-
V)
:c
I-
>-
V) 10.5'
0:::: PER P~
21
10.5'
PERP~ --
I
29.0'
6-B
45.0'
~
fa~~~.: OJ ~~~
n~h ~
~ !:l & I;i
47.05' 't 20.00'
~ ~ O.
~j~~~ ." !il
in
This drawing is not intended to be represented as a retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of
Carmel, Indiana dated February 19, 2003.
STR.# 140
TC=90B.55
PER RECORD
DRAI\1NG