Loading...
HomeMy WebLinkAbout06080143 Site Plan -' '--, Schneider The Schneider Corporation 6g01 008 Avenue HiBlorio Fort Hamrroo Indianapolis. IndlllI18. 48218-103'1 317-626-7100 317-626-7200 FAX This Plot Pion Prepored For: Beozer Homes Lot # 1085, BLOCK "K" The Villoge of Westcloy Section # 6001 INSTR. # 200500080672 PC 3, SLlOE 790 Homilton County, Cloy Township See 29, T18N, R03E 12815 FORSYTH STREET ~O' R/W) Cormel,-IN --46032 Prepared Date: 07/20/06: By: KAG Community Restrictions: Side Yard = S' MIN (ONE SIDE) Rear Yard = N/~ Aggregate = 20r. LOT \\lOTH, MIN. 5' ONE SIDE Zoning = SI Note; The contractor is to maintain 0 minimum distance of ten feet (10') between the sonitary sewer and water line laterals. Finished Floor Elevation Information Pad Grade = 906.4 per plan Edge of Pavement (LO.P.) = 910.7 ( highpoin! ) E.O.P. + 0.2' = Garage FFE ( 910.9) Garage FFE + 0.67' = Residential FFE (911.6 Engineerina SurveJlng Landscape Arclrlleeture CIS .IJS Geology Plat Pian legend I]Q[[J Proposed Grades 000.0 Existing Grades __ 000.0-- Contour Grode * Approx. Lateral Location - . - Sanitary Sewer Lines -" - Storm Sewer Lines - 'W - Waler Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) . Beehive Inlet (Storm) -1IlII -Curb-inlet (Storm) o End Section (Storm) .... Fire Hydrant - " " " - " " 0 _ Flow Line of swale - Building Une (Bl / BSL) - - - - - - - Easement Line Note: Sanitary Sewer Tap of Casting Information Upstream Manhole. TC= 908.62 Downstream Manhole, TC= 90B.55 Per Record Nate: This drawing is based on construction p'lans or record drawings. and is not based upon 0 field survey. The Schneider Corporation does not warrant Ithe accuracy or sufficiency of this information. Contr6ctors should verify existing conditions prior to any construction. Any discrepancy found an this drawing should be reported to The Schneider Corporation immediately. foiling to do so results in the contractors assumption of all liability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five reet (25'). however a dwelling may be Increased in height to thirty-five feet (35') provided the side and rear yards are Increased an additional one foot (1') far each one foot (1') the structure exceeds the first twenty-'five feet (25') in height. LOT # 1085 VB #.06.0058391 ~ ~ =~= ~ Assumed North o 10 20 I J I SCAlE 1" = 20' Note: Builder to ensure positive drainage away from structure(s). ~ TYPICAL SWALE SECTION " " " " " " .1 CONGRESS STREET 29.C' (909.09) ,- ~ B-B H ROll CURB ' PER ~ > FLOOD HAZARD STATEMENT CERTiFICATION ~\IIIIII\I\IIIIIIIII/fllll/, #"~<: L /l ~"'~ ~~':J . IJ/J/,~ #~~~>;:'.'\S'T"ii?'{:'V.{..-~ ~ ..~.."u N ... .."".""", ~ ~~ ..,~v 0 O"';o~ ~~/ ".... % ~ l S0303 \ ~ ~ . . ~ % \. STATE OF..... If ?: /". ,.' [f! ~ ~ ~ ....(,IVOI A\'\!":.... ~~ ~ '#; ..S....U..R..,i I: ~ # ~ij/, , \. ~~~ ~IIIIIIIIIIIIIIII\\\\\\\\\\ Oc-lrv I- W w 0:::: l- V) :c I- >- V) 10.5' 0:::: PER P~ 21 10.5' PERP~ -- I 29.0' 6-B 45.0' ~ fa~~~.: OJ ~~~ n~h ~ ~ !:l & I;i 47.05' 't 20.00' ~ ~ O. ~j~~~ ." !il in This drawing is not intended to be represented as a retracement or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of Carmel, Indiana dated February 19, 2003. STR.# 140 TC=90B.55 PER RECORD DRAI\1NG