Loading...
HomeMy WebLinkAboutRoof PlansA2021 A202 2 A201 2 A201 1 A A B B C C 11 22 33 44 55 66 77 7.57.5 99 D D A1 1 Mechanical Area 701 6 6 7 8 8 EW9EW9881/4":1'1/4":1'1/4":1'1/4":1'1/4":1'1/4":1' 1/4":1' 1/4":1' 1/4":1' GENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS. 2. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE OWNER. 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENT REGULATORY AGENCIES. 4. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS-PROJECT DATA AND SAMPLES TO OWNER/ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OF ALL MILLWORK AND WALL FINISHES. 5. DO NOT SCALE ANY DRAWINGS. ANY DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS. REFER ALL QUESTIONS TO THE ARCHITECT OR ENGINEER ON RECORD. 6. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.N.O. 7. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD DOCUMENTS SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE PROJECT. 8. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORKS AND EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF WORK. 9. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK. 10. ALL INTERIOR WALLS ARE TO DECK UNLESS NOTED OTHERWISE. PLAN KEY NOTES 1. 3500 LBS ELEVATOR SIMILAR TO SCHINDLER 3300 MRL TRACTION 2. 4000 LBS ELEVATOR SIMILAR TO SCHINDLER 3300 XL MRL TRACTION 3. (6) INVERTED "U" BIKE RACKS. COMPLY WITH CITY STANDARDS 4. ELECTRIC CAR CHARGER. SEE ELECTRICAL. 5. BOTTLE FILLER. SEE PLUMBING. 6. ROOF DRAIN & OVERFLOW 7. ROOF HATCH -48" x 48" 8. MERCHANTS ROOF SIGNAGE BY SIGNAGE PROVIDER. SEE STRUCTURAL FOR SUPPLEMENTAL FRAMING. 9. HANDLE IT CORNER COLUMN PROTECTOR. 24" HEIGHT. 10. PREFINISHED ALUMINUM DOWNSPOUT 11. PREFINISHED ALUMINUM GUTTER 12. PREFINISHED ALUMINUM SCUPPER 13. ALL FEC UNITS TO RECEIVE STAINLESS STEEL HOUSING U.N.O. 14. BUILT UP TAPERED INSULATION TO ACHIEVE POSITIVE DRAINAGE 15. TEMPERED GLASS RAILING SYSTEM. MINIMUM OF 42" A.F.F. ARCHITECTCLIENTCONSTRUCTION MANAGERPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS22005 May 22, 2023 Permit Set A106ROOF PLANMerchants BankHQ2420 3rd Ave. SWCarmel, IN 46032SCALE: 1/8" = 1'-0"A106 1 Roof Plan