HomeMy WebLinkAboutRoof PlansA2021
A202 2
A201
2
A201
1
A
A
B
B
C
C
11
22
33
44
55
66
77
7.57.5
99
D
D
A1 1
Mechanical Area
701
6
6
7
8
8
EW9EW9881/4":1'1/4":1'1/4":1'1/4":1'1/4":1'1/4":1'
1/4":1'
1/4":1'
1/4":1'
GENERAL NOTES
1. THE GENERAL CONTRACTOR SHALL VERIFY ALL
CONDITIONS AT THE JOBSITE. NOTIFY ARCHITECT OF
ANY DEVIATIONS FROM THOSE CONDITIONS AS THEY
ARE NOTED ON THE DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL COORDINATE AND
SCHEDULE ALL WORK WITH THE OWNER.
3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR
COMPLIANCE WITH ALL STATE AND LOCAL BUILDING
CODES AND GOVERNMENT REGULATORY AGENCIES.
4. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP
DRAWINGS-PROJECT DATA AND SAMPLES TO
OWNER/ARCHITECT FOR APPROVAL PRIOR TO
FABRICATION OF ALL MILLWORK AND WALL FINISHES.
5. DO NOT SCALE ANY DRAWINGS. ANY DIMENSIONS ARE
TO BE OBTAINED FROM THE ARCHITECT IF NOT NOTED
ON THE DRAWINGS. REFER ALL QUESTIONS TO THE
ARCHITECT OR ENGINEER ON RECORD.
6. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.N.O.
7. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF
PLANS AT THE JOBSITE FOR THE SPECIFIC PURPOSE OF
RECORDING ACTUAL CONSTRUCTION CONDITIONS. SUCH
PROJECT RECORD DOCUMENTS SHALL BE PROVIDED
TO THE OWNER UPON COMPLETION OF THE PROJECT.
8. THE GENERAL CONTRACTOR SHALL VERIFY SIZE,
LOCATION, AND CHARACTERISTICS OF ALL WORKS AND
EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS WITH
THE MANUFACTURER OR SUPPLIER PRIOR TO THE START
OF WORK.
9. THE GENERAL CONTRACTOR SHALL SEE THAT ALL
SUBCONTRACTORS RECEIVE COMPLETE WORKING
DRAWINGS AND ASSUME FULL RESPONSIBILITY FOR
COORDINATION OF WORK.
10. ALL INTERIOR WALLS ARE TO DECK UNLESS NOTED
OTHERWISE.
PLAN KEY NOTES
1. 3500 LBS ELEVATOR SIMILAR TO SCHINDLER 3300 MRL
TRACTION
2. 4000 LBS ELEVATOR SIMILAR TO SCHINDLER 3300 XL MRL
TRACTION
3. (6) INVERTED "U" BIKE RACKS. COMPLY WITH CITY
STANDARDS
4. ELECTRIC CAR CHARGER. SEE ELECTRICAL.
5. BOTTLE FILLER. SEE PLUMBING.
6. ROOF DRAIN & OVERFLOW
7. ROOF HATCH -48" x 48"
8. MERCHANTS ROOF SIGNAGE BY SIGNAGE PROVIDER. SEE
STRUCTURAL FOR SUPPLEMENTAL FRAMING.
9. HANDLE IT CORNER COLUMN PROTECTOR. 24" HEIGHT.
10. PREFINISHED ALUMINUM DOWNSPOUT
11. PREFINISHED ALUMINUM GUTTER
12. PREFINISHED ALUMINUM SCUPPER
13. ALL FEC UNITS TO RECEIVE STAINLESS STEEL HOUSING U.N.O.
14. BUILT UP TAPERED INSULATION TO ACHIEVE POSITIVE
DRAINAGE
15. TEMPERED GLASS RAILING SYSTEM. MINIMUM OF 42" A.F.F. ARCHITECTCLIENTCONSTRUCTION MANAGERPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS22005
May 22, 2023
Permit Set
A106ROOF PLANMerchants BankHQ2420 3rd Ave. SWCarmel, IN 46032SCALE: 1/8" = 1'-0"A106
1 Roof Plan