HomeMy WebLinkAboutE203C - THIRD FLOOR LIGHTING PLAN - AREA CM
M MMM
M
M
M
M
M M M
CORRIDOR
C305
MECH
U306
IDF
U305
MECH
U304
X1
X1
H3 H3H3
LA7
NL
H2
H2
X1
X1
X1X1
X1
X1
X1
CORRIDOR
C307
CORRIDOR
C306
STAIR 3
ST3-3
H4
NL
H4H4H4H4 H4 H4 H4 H4
NLNL2H4-20
H4
H4
H4
H4
H4
NL
NL
2H4-20
H4
NL
H4
NL
H4H4H4H4H4
H4
H4
H4
H4
H4
NL
NL
1H1-48
1
2H4-20
2H4-27
1
S2
S2
2H2-28
2H2-28
2H4-27 2H4-27
2
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
H5C
2H4-29
3
UNIT 2BR2B.1
SEE ENLARGED
PLANS.
UNIT 2BR2A.1
SEE ENLARGED
PLANS.
UNIT 1BR1B.1
SEE ENLARGED
PLANS.
UNIT 1BR1A.3
SEE ENLARGED
PLANS.
UNIT 2BR2B.2
SEE ENLARGED
PLANS.
UNIT 1BR1C.1
SEE ENLARGED
PLANS.
UNIT 1BR1C.2
SEE ENLARGED
PLANS.
UNIT 2BR2B.1
SEE ENLARGED
PLANS.
UNIT 1BR1B.2
SEE ENLARGED
PLANS.
UNIT 2BR2A.3
SEE ENLARGED
PLANS.
UNIT 1BR1C.3
SEE ENLARGED
PLANS.
UNIT 1BR1C.4
SEE ENLARGED
PLANS.
UNIT 1BR1C.5
SEE ENLARGED
PLANS.
UNIT 1BR1C.3
SEE ENLARGED
PLANS.
UNIT 1BR1B.1
SEE ENLARGED
PLANS.
UNIT 2BR2F.1
SEE ENLARGED
PLANS.
DRAWING TITLE:
CERTIFIED BY:
DRAWING NUMBER
PROJECT NUMBER
REVISIONS:
SCOPE DRAWINGS:
These drawings indicate the general scope of the project
in terms of architectural design concept, the dimensions of
the building, the major architectural elements and the type
of structural, mechanical and electrical systems.
The drawings do not necessarily indicate or describe all
work required for full performance and completion of the
requirements of the Contract.
On the basis of the general scope indicated or described,
the trade contractors shall furnish all items required for the
proper execution and completion of the work.
ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR
2020058
E203C
THIRD
FLOOR
LIGHTING
PLAN - AREA
C CARMEL, INNORTH
A
BC
D
KEY PLAN
1/8" = 1'-0"
THIRD FLOOR - LIGHTING PLAN - AREA C1
GENERAL NOTES
A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF
HALLWAY.
B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE
CENTER AT 6'-0" AFF.
C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER
SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON
CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO
BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL.
D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF
AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT
USED.
SHEET KEYNOTES
1 CORRIDOR NIGHTLIGHTING TO BE POWERED THROUGH AN EMERGENCY
LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR
SOURCE PANEL.
2 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY
LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR
SOURCE PANEL.
3 CATENARY LIGHTING IN THIS AREA. SEE LANDSCAPING SHEETINGS L201,
L205, AND L511 FOR MORE INFORMATION ON TYPE AND LOCATION. SEE E213D
FOR ELECTRICAL CONNECTIONS TO LIGHTING.
4 THIS FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING
INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL.