Loading...
HomeMy WebLinkAboutE203C - THIRD FLOOR LIGHTING PLAN - AREA CM M MMM M M M M M M M CORRIDOR C305 MECH U306 IDF U305 MECH U304 X1 X1 H3 H3H3 LA7 NL H2 H2 X1 X1 X1X1 X1 X1 X1 CORRIDOR C307 CORRIDOR C306 STAIR 3 ST3-3 H4 NL H4H4H4H4 H4 H4 H4 H4 NLNL2H4-20 H4 H4 H4 H4 H4 NL NL 2H4-20 H4 NL H4 NL H4H4H4H4H4 H4 H4 H4 H4 H4 NL NL 1H1-48 1 2H4-20 2H4-27 1 S2 S2 2H2-28 2H2-28 2H4-27 2H4-27 2 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 3 UNIT 2BR2B.1 SEE ENLARGED PLANS. UNIT 2BR2A.1 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 1BR1A.3 SEE ENLARGED PLANS. UNIT 2BR2B.2 SEE ENLARGED PLANS. UNIT 1BR1C.1 SEE ENLARGED PLANS. UNIT 1BR1C.2 SEE ENLARGED PLANS. UNIT 2BR2B.1 SEE ENLARGED PLANS. UNIT 1BR1B.2 SEE ENLARGED PLANS. UNIT 2BR2A.3 SEE ENLARGED PLANS. UNIT 1BR1C.3 SEE ENLARGED PLANS. UNIT 1BR1C.4 SEE ENLARGED PLANS. UNIT 1BR1C.5 SEE ENLARGED PLANS. UNIT 1BR1C.3 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 2BR2F.1 SEE ENLARGED PLANS. DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR 2020058 E203C THIRD FLOOR LIGHTING PLAN - AREA C CARMEL, INNORTH A BC D KEY PLAN 1/8" = 1'-0" THIRD FLOOR - LIGHTING PLAN - AREA C1 GENERAL NOTES A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT USED. SHEET KEYNOTES 1 CORRIDOR NIGHTLIGHTING TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 2 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 3 CATENARY LIGHTING IN THIS AREA. SEE LANDSCAPING SHEETINGS L201, L205, AND L511 FOR MORE INFORMATION ON TYPE AND LOCATION. SEE E213D FOR ELECTRICAL CONNECTIONS TO LIGHTING. 4 THIS FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL.