HomeMy WebLinkAboutE206C - SIXTH FLOOR LIGHTING PLAN - AREA CM MMM M M M M M M M H2 6H4 IDF/MECH U607 IDF U606 MECH U604 X1 X1 H3 H3H3 LA7 NL H2 H2 X1 X1 X1X1 X1 X1 H4 NL H4H4H4H4 H4 H4 H4 H4 NLNL6H1-21 H4 H4 H4 H4 H4 NL NL 6H1-21 H4 NL H4 NL H4H4H4H4H4 H4 H4 H4 H4 NL NL 1H1-48 1 6H1-21 6H4-17 1 6H4-17 6H4-17 CORRIDOR C605 CORRIDOR C606 CORRIDOR C607 STOR. U605 1 6H4-17 1H1-55 STAIR 3 ST3-6 1 2 3 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 H5B 6H4-19 UNIT 2BR2B.1 SEE ENLARGED PLANS. UNIT 2BR2A.1 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 1BR1A.3 SEE ENLARGED PLANS. UNIT 2BR2B.2 SEE ENLARGED PLANS. UNIT 1BR1C.1 SEE ENLARGED PLANS. UNIT 1BR1C.2 SEE ENLARGED PLANS. UNIT 2BR2B.1 SEE ENLARGED PLANS. UNIT 1BR1B.2 SEE ENLARGED PLANS. UNIT 2BR2A.3 SEE ENLARGED PLANS. UNIT 1BR1C.5 SEE ENLARGED PLANS. UNIT 1BR1C.3 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 2BR2F.1 SEE ENLARGED PLANS. DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR 2020058 E206C SIXTH FLOOR LIGHTING PLAN - AREA C CARMEL, IN1/8" = 1'-0" SIXTH FLOOR - LIGHTING PLAN - AREA C1 NORTH A BC D KEY PLAN GENERAL NOTES A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT USED. SHEET KEYNOTES 1 CORRIDOR NIGHTLIGHTING TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 2 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 3 FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL.