Loading...
HomeMy WebLinkAboutE206D - SIXTH FLOOR LIGHTING PLAN - AREA DM M M MMM M M MMM 6H1 6H2 IDF U611 MECH U609 UTILITY U608 H3 X1 X1 X1 X1 H3 H3 X1 CORRIDOR C610 H4 NL H4 H4 H4 H4 NL H4 H4 H4 NL H4 H4 NL H4 NL H4 H4 H4 H4 NL H4H4H4 H4 H4 H4 NL H4 NL H4 H4 6H1-21 6H1-21 1 1 6H1-21 1 1 6H2-23 CORRIDOR C608 CORRIDOR C609 STOR. U610 6H2-23 6H2-23 6H2-23 3 3 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 H5B 6H2-17 UNIT 2BR2B.3 SEE ENLARGED PLANS. UNIT 2BR2B.4 SEE ENLARGED PLANS. UNIT 2BR2A.2 SEE ENLARGED PLANS. UNIT 1BR1B.2 SEE ENLARGED PLANS. UNIT 1BR1A.3 SEE ENLARGED PLANS. UNIT 1BR1A.4 SEE ENLARGED PLANS. UNIT 1BR1C.2 SEE ENLARGED PLANS. UNIT 1BR1C.1 SEE ENLARGED PLANS. UNIT 1BR1A.2 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 2BR2B.3 SEE ENLARGED PLANS. UNIT 3BR2A.1 SEE ENLARGED PLANS. UNIT 1BR1B.2 SEE ENLARGED PLANS. UNIT 1BR1C.1 SEE ENLARGED PLANS. UNIT 1BR1D.2 SEE ENLARGED PLANS. UNIT 1BR1C.6 SEE ENLARGED PLANS. DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR 2020058 E206D SIXTH FLOOR LIGHTING PLAN - AREA D CARMEL, INNORTH A BC D KEY PLAN 1/8" = 1'-0" SIXTH FLOOR - LIGHTING PLAN - AREA D1 GENERAL NOTES A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT USED. SHEET KEYNOTES 1 CORRIDOR NIGHTLIGHTING TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 2 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 3 FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL.