HomeMy WebLinkAboutE201A - FIRST FLOOR LIGHTING PLAN - AREA AM
M M
M M M M M M
M
M
M M M M
M
M
M
M
M
M
STAIR 1
ST1-1
H1
H1E
H1
H1E
H2
H2
H1E H1 H1E H1 H1E
H4
NL
X1X1
X1
H4H4
H2 H2
1
H2
H2
2
2
CORRIDOR
C105
H3 H3
H3
H3H3H3H3H3H3H3H3H3
1H3-25
BIKE STORAGE
G127 1H3
H3
H3
H3
MDF
U105
?
?
1H3-34
1H3-25
CORRIDOR
C103
PARKING-1
G100-1
SEE CONTINUATION
FOR CIRCUIT
1H3-27
1H3-32
E412
1
H4
H4
H4
NL
1H3-30
MAIN LOBBY
A108
1H3-34
2
LA7LA7
LA7
LA7
H4
H4 LA1
NL
NL
NL
1H3-25
2
2
NL
H4
NL
H4
NL
H4
NL
H4 H4 H4 H4 H4 H4 H4 H4
1H3-34
H4
NL
H4
H4
H4
LEASING/AMENITIES
A101
LOBBY LOUNGE
A107
COFFEE
LOUNGE
A102
MGR OFFICE
A103
OFFICE
A104
WORK ROOM
A105
MECH
A111 RR
A106
3
4
LA15
H4 H4
H4
H4 H4
H4
PARCEL
A109
LA15
H4
1H3-25
1H3-25
H5A
1H3-36
H5A
1H3-36
H5A
1H3-36
H5A
1H3-36
H5B
1H3-36
H5B
1H3-36
H5A
1H3-36
H5A
1H3-36
H5B
1H3-36
H5B
1H3-36
H1
1H3-25 1H3-25 1H3-25 1H3-25 1H3-25 1H3-25
H3
H4H4
H4 H4
X1
X1
DRAWING TITLE:
CERTIFIED BY:
DRAWING NUMBER
PROJECT NUMBER
REVISIONS:
SCOPE DRAWINGS:
These drawings indicate the general scope of the project
in terms of architectural design concept, the dimensions of
the building, the major architectural elements and the type
of structural, mechanical and electrical systems.
The drawings do not necessarily indicate or describe all
work required for full performance and completion of the
requirements of the Contract.
On the basis of the general scope indicated or described,
the trade contractors shall furnish all items required for the
proper execution and completion of the work.
ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR
2020058
E201A
FIRST FLOOR
LIGHTING
PLAN - AREA
A CARMEL, INNORTH
A
BC
D
KEY PLAN
1/8" = 1'-0"
FIRST FLOOR - LIGHTING PLAN - AREA A1
SHEET KEYNOTES
1 PROVIDE LIGHTS AND SWITCH IN ELEVATOR PIT. COORDINATE EXACT
LOCATION OF DEVICES WITH ELEVATOR INSTALLER PRIOR TO ROUGH-IN.
2 CORRIDOR NIGHTLIGHTING AND EXIT SIGNS TO BE POWERED THROUGH AN
EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION
NEAR SOURCE PANEL.
3 FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO
BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL.
4 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY
LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR
SOURCE PANEL.
GENERAL NOTES
A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF
HALLWAY.
B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE
CENTER AT 6'-0" AFF.
C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER
SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON
CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO
BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL.
D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF
AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT
USED.