Loading...
HomeMy WebLinkAboutE201B - FIRST FLOOR LIGHTING PLAN - AREA BM M M M M M CORRIDOR C105 TRASH ROOM G102 STAIR 2 ST2-1 H1E H1 H1E H1 H1E H1 H1E H1E H3 H3 H3 H3 H3 H3 H2 H2 H1 H1E RAMP TO SECOND FLOOR PARKING. SEE SECOND FLOOR FOR LIGHTING IN THIS AREA H4 NL X1 X1 2 RECYCLING G101 SEE CONTINUATION FOR CIRCUIT PARKING-1 G100-1 1H3-29 1H3-30 1H3-30 1H3-30 H4 NL H4 NL H4 H4 H4 H4 H4 H4 1H3-30 3 4 3 3 H5A 1H3-36 H5A 1H3-36 H5A 1H3-36 H5A 1H3-36 H5A 1H3-36 H5A 1H3-36 H5A 1H3-36 H5A 1H2-10 X1 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H5A 1H2-10 H1 UNIT 1BR2LW.1 SEE ENLARGED PLANS. UNIT 2BR3LW.1 SEE ENLARGED PLANS. UNIT 1BR2LW.2 SEE ENLARGED PLANS. UNIT 1BR2LW.1 SEE ENLARGED PLANS. UNIT 1BR2LW.3 SEE ENLARGED PLANS. H5B 1H2-10 H5B 1H2-10 X1 X1 X1 DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR 2020058 E201B FIRST FLOOR LIGHTING PLAN - AREA B CARMEL, IN1/8" = 1'-0" FIRST FLOOR - LIGHTING PLAN - AREA B1 NORTH A BC D KEY PLAN SHEET KEYNOTES 1 PROVIDE LIGHTS AND SWITCH IN ELEVATOR PIT. COORDINATE EXACT LOCATION OF DEVICES WITH ELEVATOR INSTALLER PRIOR TO ROUGH-IN. 2 CORRIDOR NIGHTLIGHTING AND EXIT SIGNS TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 3 FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 4 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. GENERAL NOTES A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT USED.