HomeMy WebLinkAboutE203A - THIRD FLOOR LIGHTING PLAN - AREA AM M M M M M M M M M M M STAIR 1 ST1-3 LOUNGE-1 A300-1 H3 X1 X1 X1 X1 LA7 H4H4 X1 X1 X1 CORRIDOR C302 ELEVATOR LOBBY C301 CORRIDOR C311 H2 H2 X1 H4 NL H4 H4 H4 H4 H4 NL H4 H3 NL NL H4 NL H4 NL H4 NL H4H4H4 H4 H4 H4 H4H4H4H4 NL LA4 H4 LA13 LA14 LA14 LA13 LA13 LA2 LA2 LA2 LA2LA2 LA2 LA2 LA2 LA3 LA3 LA3 LA3 LA3 2H2-24 1 2H2-26 2H2-26 1H3-27 S2 S2 S2S2 S2 2H2-28 2H2-282H2-282H2-282H2-28 2H2-262H2-26 2H2-26 2H2-26 1 1 1 2 H3 2H2-26 H3 H5C 2H2-32 H5C 2H2-32 H5C 2H2-32 H5C 2H2-32 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 H5C 2H4-30 UNIT 2BR2G.3 SEE ENLARGED PLANS. UNIT 2BR2G.4 SEE ENLARGED PLANS. UNIT 1BR1C.1 SEE ENLARGED PLANS. UNIT 1BR1C.2 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 2BR2A.1 SEE ENLARGED PLANS. UNIT 1BR1A.1 SEE ENLARGED PLANS. UNIT 1BR1E.1 SEE ENLARGED PLANS. UNIT 2BR2H.1 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 1BR1A.5 SEE ENLARGED PLANS. LA6 4 4 LA3 LA3 LA4 H3 DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR 2020058 E203A THIRD FLOOR LIGHTING PLAN - AREA A CARMEL, IN1/8" = 1'-0" THIRD FLOOR - LIGHTING PLAN - AREA A1 NORTH A BC D KEY PLAN GENERAL NOTES A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT USED. SHEET KEYNOTES 1 CORRIDOR NIGHTLIGHTING TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 2 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 3 CATENARY LIGHTING IN THIS AREA. SEE LANDSCAPING SHEETINGS L201, L205, AND L511 FOR MORE INFORMATION ON TYPE AND LOCATION. SEE E213D FOR ELECTRICAL CONNECTIONS TO LIGHTING. 4 THIS FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL.