HomeMy WebLinkAboutE203B - THIRD FLOOR LIGHTING PLAN - AREA BMM M M M M M M M M M MECH U303 STAIR 2 ST2-3 UTILITY U302 H3 X1 X1 CORRIDOR C303 X1 X1 H2 H2 H3 H4 NL H4 NL H4H4H4H4 H4 H4H4 NL H4 H4 H4 NL H4 H4 H4 NL H4 NL H4 H4 H4 H4 H4 CORRIDOR C305 2H4-27 1 1H3-29 2H2-24 1 S2 S2S2S2 2H2-28 2H2-28 2H2-28 2H2-28 2H2-24 2 H5C 2H2-32 H5C 2H2-32 H5C 2H2-32 H5C 2H2-32 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H5C 2H4-29 H4 UNIT ? SEE ENLARGED PLANS. UNIT 2BR2C.1 SEE ENLARGED PLANS. UNIT 2BR2G.3 SEE ENLARGED PLANS. UNIT 1BR1B.2 SEE ENLARGED PLANS. UNIT 2BR2A.2 SEE ENLARGED PLANS. UNIT 2BR2E.1 SEE ENLARGED PLANS. UNIT 2BR2D.1 SEE ENLARGED PLANS. UNIT 1BR1B.1 SEE ENLARGED PLANS. UNIT 2BR2A.1 SEE ENLARGED PLANS. UNIT 1BR1B.2 SEE ENLARGED PLANS. UNIT 2BR2G.1 SEE ENLARGED PLANS. UNIT 2BR2G.4 SEE ENLARGED PLANS. DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BYPROJECT:CARMEL MIDTOWN05/16/23 PLR PLR 2020058 E203B THIRD FLOOR LIGHTING PLAN - AREA B CARMEL, IN1/8" = 1'-0" THIRD FLOOR - LIGHTING PLAN - AREA B1 NORTH A BC D KEY PLAN GENERAL NOTES A GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. B WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. C OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. D PROVIDE (6) EXTRA TYPE X1 EXIT SIGNS TO BE LOCATED AT DISCRETION OF AUTHORITY HAVING JURISDICTION OR BE PROVIDED AS ATTIC STOCK IF NOT USED. SHEET KEYNOTES 1 CORRIDOR NIGHTLIGHTING TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 2 FIXTURES IN STAIRWELL TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL. 3 CATENARY LIGHTING IN THIS AREA. SEE LANDSCAPING SHEETINGS L201, L205, AND L511 FOR MORE INFORMATION ON TYPE AND LOCATION. SEE E213D FOR ELECTRICAL CONNECTIONS TO LIGHTING. 4 THIS FIXTURE TO BE POWERED THROUGH AN EMERGENCY LIGHTING INVERTER TO BE LOCATED IN ACCESSIBLE LOCATION NEAR SOURCE PANEL.