HomeMy WebLinkAbout06080183 Site Plan
Note:
This drawing is bosed on construction pions or record drawings, ,
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately; foiling to do
so results in the contractors assumption of all liability.
~.,
Schneider
This Plot Plan Prepared For: Pulte Homes
Townhomes at GuDford
Instrument I 200500080749
SEe 36, TlaN, RJE
HamDton County, Cloy T wp.
Conmel, IN 46032
Block 14
Prepored_DotLD8/28/2006 By: KAG
The Schneider Corporation
8901 0tiI Avenue
Historic Fort Harrison
lnd1anapollll, Indlana 482l6-1037
317-826-7100
317-826-7200 FAX
--..
-.,...
Landscape Architecture
GIS .IJS
Geology
Plot Pion legend
[]QQ]] Proposed Grades
000.0 Existing Grades
_000.0- Contour Grode
* Approx. Lateral Location
- . - Sanitary Sewer Lines
-IT - Storm Sewer Lines
-==---..:-.....-=::::....:.::.-Water Service lines- -
- - - - - - - Sub-Surface Drain lines
. Manhole (Sonitory or Storm)
. Beehive Inlet (Storm)
II1II Curb Inlet (Storm)
D End Section (Storm)
... Fire Hydrant
- " " " - " 0 " - Flow line of swole
- Building Line (BL ! BSL)
- - - - - - - Easement Line
Pulte Homes
Finished Floor Elevation Information
PAD= 849.48
FFE= 849,98
LOT #
1401
1402
1403
1404
ADDRESS
773 Ivy Lane
767 Ivy Lane
761 Ivy Lane
755 Ivy Lane
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 849.40
Downstream Manhole, TC=847.90
per pion.
II
B49,19
m
~
~
~
849,64
~
ROll CURB
w
:z:
<(
---.J
.
-'
.
<(
w
~t:
<( 0
> ::!E
0::: ::!E
<( 0
::r:: U
5,0'
PER PLAN I
24.0' -15.4'
B-B 1- 10.4'
: 1849.41/10,5'
I
: 34,68
# 1404
<Xi # 1403
<0
1-.
<Xi
<0
I
I
1>l:l'
I~~
I~~
23.96
10.510.5' I
23,96
BLOCK 14
~
~b
=~=
~
Assumed North
Scale : 1~ = 30'
2~
STR,# 408
TC=847,90
PER PLAN
,
"L"
848,7
\10,5'
31.65 31.6:
TC=847,20
is PFR PI~._
000-
r= B48,3 ME
~
""
'"
M
'I .11000
lMliJ [
10' BUILDING SETBACK
~
i3
;;i
NOTE: ~
IN THE RESIDENTIAL DISTRICTS LIMITING
HEIGHT TO TWENTY-FIVE (25) FEET, A
DWELLING MAY BE INCREASED IN
HEIGHT TO THIRTY-FIVE (35) FEET
PRO~DED THE ~DE AND REAR YARDS
ARE INCREASED AN ADDITIONAL FOOT
FOR EACH FOOT SUCH STRUCTURE
EXCEEDS TWENTY-FIVE (25) FEET IN
HEIGHT, PER CARMEL ZONING
ORDINANCE 26,1,1,
z
'"
'0
I
4',\ 51-OPt.
:...
TYl'ICAL SWALE SECTION
Note: The COIl tractor is to maintain 0
minimum distance of ten feet (10')
between the sanitary sewer ond woter
line laterals.
This drawing is not intended to be represented as a retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
FLOOD HAZARD STATEMENT: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rote map (FlRM). ALL of the within described land DOES NOT LIE within that special flood hazard
zone A os said land plots by scale on flood insurance rate map I 18057C0209F for Hamilton County,
Indiana (map effective date February 19, 2003).
FLOOD HAZARD STATEMENT
CERllFICA 1l0N
:>,\\\\\\\\\\1111111IJ1111/
0\\\\ L I///ij/.
'* ,C . />/) ~
~ ~ "-:),..,,.......,f.1/It'l.J'~
~ <..~~...'G\S TEri;;.... 0/ A~
~ "......., . ~ N "0''- ~
~ ~:.,"Q;- o. ......~,<:>~
:=: . ~
5 50303. 5
% '. STATE OF ,Y ~
~ '/'. ." ~
% (" ~.....:.'YOI A~,~"...~~
% '4tJ '5""U"0\1 C-::' #
~IIIJ. I\"'\..;..\\Y:;.~
rIIIIIII/I/IIIIIIII!!\\I\" I
~lfi1