Loading...
HomeMy WebLinkAbout06080184 As Built Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Controctors should verify existing conditions prior to ony construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; failing to do so results in the contractors assumption of all liability. 10.5 10." I \ 10.5' 23.96 23.96 1.65 31.6~ TC=847.20 ~ ooolS PFR PI~._ 1 D. BUILDING SElBACK I' 848.3 ME ~~ Schneider The Schneider Col'Jloration 8901 OW A.venue IUnoric Fort Hmillon IndianapoJiJ, Indiana 46216-1037 317-626-7100 317-826-7200 FAX "'<in""" _eying Landscape Archilecture GIS 'US """"I)' _.~- This Plot Plan Prepared For: Pulte Homes T ownhomes at GuDford Instrument' 200500080749 SEe 36, TlaN, R3E HarnDton County, aay Twp. Carmel, IN 46032 Block 14 Prepared Date: Plot Plan leqend []QQ]] Proposed Grades 000.0 Existing Grades _000.0- Contour Grade * Approx. lateral location - . - Sanitary Sewer lines D872S"72006 -'-B-:-KIiC-- -.----.., '" --Storm-Sew,r U~" . .Y: - 1,/ - Water SerVIce lines - - - - - - - Sub-Surface Drain lines . Manhole (Sanitary or Storm) . Beehive Inlet (Storm) DIll Curb Inlet (Storm) D End Section (Storm) .... Fire Hydrant - 0 0 . - . . . - Flow line of swale - Building Une (BL ! BSL) - - - - - - - Easement line Pulte Hames Finished Floor Elevation Information PAD= 849.48 FFE= 849.98 LOT # 1401 1402 1403 1404 ADDRESS 773 Ivy Lane 767 Ivy Lane 761 Ivy Lane 755 Ivy Lane Note: Sanitary Sewer Top of Casting Information Upstream Manhole. TC= 849.40 Downstream Manhole, TC=847.90 per plan. I~ w :z: <( -1 31.65 22.0' 17.0' 16' DR'''' 23.96' /i TV<<> CAR T'MJ CAR TWO CAR ':::: ~ ~I ..';~ :-"7 ~ ?~ ~ ~ Wt6t1oW >- itI IJ^B' >- irIti/ 1-. ~. ~ 2391 --. ~ 2510 ~ 2391 co ...,. FRtr.I&J,lSY ... FRl.ldcMSY FRt.lkMSY 1-- RESIDENCE ;...... RESIDENCE r- RESIDENCE ~ g # 1403 g # 1402 ffi # 1401 ~ , -' , <( w 6:t: <( 0 > :::;; 0::: :::;; <( 0 ::r:: U 5.0' PER PlAN I 24.0' 8-8 # 1404 10.4' 1 ' I 849.4VlO." I 34.68 I I I~~ I~ ;l; 'I\~ 00 U'1 "'" N \~ .1$00. B48.2 [ III B ;;j NOTE: ~ IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1. z :> \:, , "- 4: 1 SLOPE: 4'. \ s\.O?( TYPICAL SWALE SECTION Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water linaloterals. This drawing is not intended to be represented os a retracement or original boundary survey, a route survey, or a Surveyor Location Report. FLOOD HAZARD STATEMENT: The accuracy of any flood hazard data shown on this report is subject to mop scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map (FlRM). All of the within described land DOES NOT UE within that special flood hazard zone A as said land plots by scale on flood insurance rate map , t8057C0209F for Hamilton County, Indiana (map effective date February 19, 2003). BLOCK 14 o ---U =~= o Assumed North Scale; 1. = 3D' ~ 24.5' 239~ STR.# 408 TC=847.90 PER PLAN ilL" 848.7 FLOOD HAZARD STATEMENT CERTIFICATION ~\\\\\\\\\\IIIJJIIJIII!III/, ~\\\'\ t.. L /'I 11/0/;: ~ ~,.\.~ 'v;LJ/, ~ '*'.;:,.~' ............../TV,/,'% $ ~...,..G\S TE"f?.t....~"'O%: %~...,<>-'v No O....;G>'& 2;: . ". ~ I 50303 \ I % "STATE OF,: fI ~ /", .: it ~("~"'.:.tvDrAt.\.!':'/~~ % '4() .S....U..R.';i~,--<:: ,# ~//, '1\.':.\\~~ '11/1/11/1/1/111\\\\\\\\\\\'1 ~l~ /.:;