HomeMy WebLinkAbout06080184 As Built
Note:
This drawing is based on construction plans or record drawings,
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this information.
Controctors should verify existing conditions prior to ony
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately; failing to do
so results in the contractors assumption of all liability.
10.5 10." I \ 10.5'
23.96 23.96 1.65 31.6~
TC=847.20
~ ooolS PFR PI~._
1 D. BUILDING SElBACK I' 848.3 ME
~~
Schneider
The Schneider Col'Jloration
8901 OW A.venue
IUnoric Fort Hmillon
IndianapoJiJ, Indiana 46216-1037
317-626-7100
317-826-7200 FAX
"'<in"""
_eying
Landscape Archilecture
GIS 'US
""""I)'
_.~-
This Plot Plan Prepared For: Pulte Homes
T ownhomes at GuDford
Instrument' 200500080749
SEe 36, TlaN, R3E
HarnDton County, aay Twp.
Carmel, IN 46032
Block 14
Prepared Date:
Plot Plan leqend
[]QQ]] Proposed Grades
000.0 Existing Grades
_000.0- Contour Grade
* Approx. lateral location
- . - Sanitary Sewer lines
D872S"72006 -'-B-:-KIiC-- -.----.., '" --Storm-Sew,r U~"
. .Y: - 1,/ - Water SerVIce lines
- - - - - - - Sub-Surface Drain lines
. Manhole (Sanitary or Storm)
. Beehive Inlet (Storm)
DIll Curb Inlet (Storm)
D End Section (Storm)
.... Fire Hydrant
- 0 0 . - . . . - Flow line of swale
- Building Une (BL ! BSL)
- - - - - - - Easement line
Pulte Hames
Finished Floor Elevation Information
PAD= 849.48
FFE= 849.98
LOT #
1401
1402
1403
1404
ADDRESS
773 Ivy Lane
767 Ivy Lane
761 Ivy Lane
755 Ivy Lane
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole. TC= 849.40
Downstream Manhole, TC=847.90
per plan.
I~
w
:z:
<(
-1
31.65
22.0'
17.0' 16'
DR''''
23.96' /i
TV<<> CAR T'MJ CAR TWO CAR '::::
~ ~I ..';~ :-"7 ~ ?~ ~
~ Wt6t1oW >- itI IJ^B' >- irIti/ 1-. ~.
~ 2391 --. ~ 2510 ~ 2391 co
...,. FRtr.I&J,lSY ... FRl.ldcMSY FRt.lkMSY
1-- RESIDENCE ;...... RESIDENCE r- RESIDENCE ~
g # 1403 g # 1402 ffi # 1401 ~
,
-'
,
<(
w
6:t:
<( 0
> :::;;
0::: :::;;
<( 0
::r:: U
5.0'
PER PlAN I
24.0'
8-8
# 1404
10.4' 1 '
I 849.4VlO."
I
34.68
I
I
I~~
I~
;l;
'I\~
00
U'1
"'"
N
\~ .1$00.
B48.2 [
III
B
;;j
NOTE: ~
IN THE RESIDENTIAL DISTRICTS LIMITING
HEIGHT TO TWENTY-FIVE (25) FEET, A
DWELLING MAY BE INCREASED IN
HEIGHT TO THIRTY-FIVE (35) FEET
PROVIDED THE SIDE AND REAR YARDS
ARE INCREASED AN ADDITIONAL FOOT
FOR EACH FOOT SUCH STRUCTURE
EXCEEDS TWENTY-FIVE (25) FEET IN
HEIGHT. PER CARMEL ZONING
ORDINANCE 26.1.1.
z
:>
\:,
,
"-
4: 1 SLOPE:
4'. \ s\.O?(
TYPICAL SWALE SECTION
Note: The contractor is to maintain a
minimum distance of ten feet (10')
between the sanitary sewer and water
linaloterals.
This drawing is not intended to be represented os a retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
FLOOD HAZARD STATEMENT: The accuracy of any flood hazard data shown on this report is subject to
mop scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map (FlRM). All of the within described land DOES NOT UE within that special flood hazard
zone A as said land plots by scale on flood insurance rate map , t8057C0209F for Hamilton County,
Indiana (map effective date February 19, 2003).
BLOCK 14
o
---U
=~=
o
Assumed North
Scale; 1. = 3D'
~
24.5'
239~
STR.# 408
TC=847.90
PER PLAN
ilL"
848.7
FLOOD HAZARD STATEMENT
CERTIFICATION
~\\\\\\\\\\IIIJJIIJIII!III/,
~\\\'\ t.. L /'I 11/0/;:
~ ~,.\.~ 'v;LJ/, ~
'*'.;:,.~' ............../TV,/,'%
$ ~...,..G\S TE"f?.t....~"'O%:
%~...,<>-'v No O....;G>'&
2;: . ". ~
I 50303 \ I
% "STATE OF,: fI
~ /", .: it
~("~"'.:.tvDrAt.\.!':'/~~
% '4() .S....U..R.';i~,--<:: ,#
~//, '1\.':.\\~~
'11/1/11/1/1/111\\\\\\\\\\\'1
~l~
/.:;