Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Title Sheet
F4 TIER 5TIER 24 X 36 24 X 6024 X 6024 X 6024 X 6024 X 6024 X 6024 X 6024 X 48D DD 24 X 60 24 X 54 24 X 6024 X 6024 X 6024 X 6024 X 60 24 X 4836DR24 X 6024 X 6018 X 54DD24 X 48 24 X 48R RDAIR OUTAIR OUTAIR OUTAIR OUT20 X 36 20 X 3636"DR30DRD24 X 48DDCHCCWICWOG G GG G GG G G36DR24 X 6024 X 6021 X 4821 X 4818 X 42 18 X 3624 X 4824 X 6024 X 48 24 X 48 24 X 48 24 X 48 24 X 48 24 X 4818 X 4224 X 6024 X 6024 X 54 24 X 54 24 X 3024 X 36CCOWNER ROOTSTOCK HOSPITALITY 2602 RUTH DRIVE INDIANAPOLIS, IN 46240 CONTACT:ANDREW VUDIS PHONE:(317) 850-9578 E-MAIL:ANDREW@ROOTSTOCKHG.COM CONTACT:RYAN CRAIG PHONE:(317) 716-8391 E-MAIL:RCRAIG@ROOTSTOCKHG.COM ARCHITECT OF RECORD SHEA 10 SOUTH EIGHTH STREET MINNEAPOLIS, MN 55402 PHONE:(612) 339-2257 CONTACT 1:BRIAN ANDERSON E-MAIL:BRIANA@SHEADESIGN.COM CONTACT 2:KATIE LICHTENHELD E-MAIL: KATIE.LICHTENHELD@SHEADESIGN.COM CONTRACTOR STRUCTURAL ENGINEER M.E.P. ENGINEER FOOD SERVICE COMPANY NAME ADDRESS ADDRESS PHONE:(XXX) XXX-XXXX CONTACT:XXXX E-MAIL:XXXX@XXXX.COM DESIGN BUILD MOBILE FIXTURE & EQUIPMENT CO 1155 MONTLIMAR DRIVE MOBILE, AL 36609 PHONE:(251) 342-0455 CONTACT:CHRIS PACEY E-MAIL:C.PACEY@MOBILEFIXTURE.COM McCOMAS/ O'DONNELL & NACCARATO 450 E 96TH STREET #175 INDIANAPOLIS, IN 46240 PHONE:(317) 580-0402 CONTACT:TOM MILTNER E-MAIL:TMILTNER@O-N.COM PROJECT TEAM Name Elevation _____(SIM) XXX X ALIGN ROOM NAME XXX 150 SF101 1i 1A3 1 1 1 ?t PT-12 BS-13 CPT-14 ACT-11 BS-1 (EXST) DENOTES EXTENT OF FLOOR MATERIAL DENOTES EXTENT OF FLOOR MATERIAL 1 = CEILING FINISH TYPE 2 = WALL FINISH TYPE 3 = BASE FINISH TYPE 4 = FLOOR FINISH TYPE DENOTES FINISH REFERENCE SYMBOL (SEE FINISH PLAN) NOTE: SEE PROJECT MANUAL FOR ADDITIONAL INFORMATION. DENOTES FURNITURE TYPE (SEE FURNITURE SCHEDULE) DENOTES ELEVATION REFERENCE SYMBOL (SEE ELEVATIONS) _____(SIM) XXX X _____(SIM) XXX X _____(SIM) XXX X DENOTES SECTION/ DETAIL REFERENCE SYMBOL (SEE DETAILS AND SECTIONS) DENOTES DETAIL REFERENCE SYMBOL (SEE DRAWINGS) DENOTES DETAIL AND ENLARGED PLAN REFERENCE SYMBOL (SEE DETAILS AND ENLARGED PLANS) DENOTES REVISION DELTA REFERENCE SYMBOL (SEE DRAWINGS) DENOTES WINDOW TYPE REFERENCE SYMBOL (SEE DRAWINGS) DENOTES DEMOLITION PLAN KEY NOTE REFERENCE SYMBOL (SEE DEMOLITION PLAN) DENOTES PLAN KEY NOTE REFERENCE SYMBOL (SEE PLANS) DENOTES TO ALIGN FACE OF OBJECTS (SEE DRAWINGS) DENOTES ELEVATION REFERENCE SYMBOL (SEE INTERIOR ELEVATIONS) DENOTES PARTITION TYPE (SEE PARTITION SHEET FOR TYPES) DENOTES ROOM NAME AND NUMBER DENOTES AREA NOT IN CONTRACT DASHED LINES DENOTE EXISTING CONSTRUCTION TO BE REMOVED INCLUDING: PARTITIONS, DOORS, FRAMES, HARDWARE, ELECTRICAL, CABINETS, GLAZING AND FRAMES, ETC. DENOTES DOOR NUMBER (SEE DOOR SCHEDULE FOR TYPE AND DETAILS) DENOTES NEW DOOR AND FRAME (SEE DOOR SCHEDULE FOR TYPE AND DETAILS) NEW PARTIAL HEIGHT WALL CONSTRUCTION (SEE PARTITION SHEET FOR TYPES) NEW WALL CONSTRUCTION (SEE PARTITION SHEET FOR TYPES) DENOTES EXISTING DOOR TO REMAIN SHADED AREAS DENOTE EXISTING CONSTRUCTION AND STRUCTURAL ELEMENTS TO REMAIN, PATCH AND REPAIR SURFACES AFFECTED BY DEMOLITION AS REQUIRED FOR NEW FINISHES CPT-2CPT-1 PROJECT SYMBOLS #DENOTES ADD ALTERNATE / DEDUCTS SYMBOL (SEE DRAWINGS) SITE MAP 150 W. 96TH STREET INDIANAPOLIS, IN 46260 SITE NORTH A.F.F.ABOVE FINISHED FLOOR AC.ACOUSTICAL AC.T.ACOUSTICAL TILE ADJ.ADJACENT ADJT.ADJUSTABLE A/C AIR CONDITIONING ALT.ALTERNATE ALUM.ALUMINUM A.B.ANCHOR BOLT ANOD.ANODIZED APPROX.APPROXIMATE ARCH.ARCHITECT (URAL) AUTO.AUTOMATIC BSMT.BASEMENT BM.BEAM BRG.BEARING BET.BETWEEN B.L.BUILDING LINE BLK.BLOCK BLKG.BLOCKING BD.BOARD BOT.BOTTOM BLDG.BUILDING B.U.R.BUILT UP ROOFING CAB.CABINET CPT.CARPET (ED) C.I.CAST IRON C.I.F.CAST IN FIELD CLG.CEILING CLG.HT.CEILING HEIGHT CEM.CEMENT CTR.CENTER C.T.CERAMIC TILE CLR.CLEAR (ANCE) CLO.CLOSET COL.COLUMN CONC.CONCRETE (CAST IN PLACE) C.M.U.CONCRETE MASONRY UNIT CONST.CONSTRUCTION CONST.JT.CONSTRUCTION JOINT CONT.CONTINUOUS/CONTINUE C.J.CONTROL JOINT C.G.CORNER GUARD CORR.CORRIDOR C.W.COLD WATER/CURTAIN WALL D.DEEP/DEPTH DET.DETAIL DIAG.DIAGONAL DIA.DIAMETER DIF.DIFFUSER DIM.DIMENSION DISP.DISPENSER DR.DOOR DWR.DRAWER DWG.DRAWING E.EAST ELEC.ELECTRIC (AL) E.W.C.ELECTRIC WATER COOLER EL.ELEVATION ELEV.ELEVATION EMER.EMERGENCY ENC.ENCLOSE (URE) EQ.EQUAL EQUIP.EQUIPMENT EXH.EXHAUST EXIST.EXISTING EXP.JT.EXPANSION JOINT EXP.EXPOSED EXT.EXTERIOR F.R.P.FIBERGLASS REINFORCED PANEL FIN.FINISH (ED) F.A.FIRE ALARM F.H.S.FIRE HOSE STATION FP.FIREPROOFING F.P.S.C.FIRE-PROOF-SELF-CLOSING F.R.T.FIRE RETARDANT TREATED F.R.FIRE-RESISTANT FLR.FLOOR (ING) F.D.FLOOR DRAIN FLUOR.FLUORESCENT FT.FOOT FTG.FOOTING FND.FOUNDATION F.A.I.FRESH AIR INTAKE F.S.FULL SIZE FURR.FURRED (ING) FUT.FUTURE GA.GAGE, GLAZING GALV.GALVANIZED GL.GLASS, GLAZING GL.BLK.GLASS BLOCK G.T.GRANITE TILE G.GRANITE GYP.BD.GYPSUM WALLBOARD G.W.B.GYPSUM WALLBOARD HBD.HARDBOARD HDW.HARDWARE HDWD.HARDWOOD HDR.HEADER H.O.HIGH OUTPUT HTG.HEATING H.V.A.C.HEATING/VENTILATION/AIR COND. HT.HEIGHT H.HIGH H.P.HIGH POINT H.C.HOLLOW CORE H.M.HOLLOW METAL HORIZ.HORIZONTAL H.B.HOSE BIBB H.W.HOT WATER HR.HOUR HYD.HYDRANT IN.INCH INCL.INCLUDE (D) (ING) I.D.INSIDE DIAMETER INSUL.INSULATE (D) (ION) INT.INTERIOR JAN.JANITOR JT.JOINT KIT.KITCHEN K.O.KNOCK OUT LBL.LABEL LAB.LABORATORY LAD.LADDER LAM.LAMINATE (D) LAV.LAVATORY L.H.LEFT HAND L.LENGTH LT.LIGHT LT.WT.LIGHTWEIGHT LIN.LINEAR LVR.LOUVER L.P.LOW POINT MFR.MANUFACTURE (R) MATL.MATERIAL (S) MAX.MAXIMUM MECH.MECHANIC (AL) MED.MEDIUM MEMB.MEMBRANE MTL.METAL MEZZ.MEZZANINE MIN.MINIMUM MIR.MIRROR MISC.MISCELLANEOUS MLD.MOLDING, MOULDING M.R.MOISTURE RESISTANT MT.MOUNT (ED) (ING) MOV.MOVABLE MULL.MULLION NAT.NATURAL NOM.NOMINAL N.NORTH N.I.C.NOT IN CONTRACT N.T.S.NOT TO SCALE NO.NUMBER OFF.OFFICE O.C.ON CENTER (S) OPG.OPENING OPP.OPPOSITE O.D.OUTSIDE DIAMETER O.A.OVERALL PARQ.PARQUET FLOORING PTD.PAINT (ED) PNL.PANEL P.BD.PARTICLE BOARD PTN.PARTITION PERF.PERFORATE (D) P.PERSON (S) PLAS.PLASTER P.LAM.PLASTIC LAMINATE PL.PLATE PLGL.PLATE GLASS PLMG.PLUMBING PWD.PLYWOOD PT.POINT PVC.POLYVINYL CHLORIDE P.S.F.POUNDS PER SQUARE FOOT P.S.I.POUNDS PER SQUARE INCH P.L.PROPERTY LINE Q.T.QUARRY TILE RAD.RADIUS RECP.RECEPTACLE REF.REFERENCE REG.REGISTER REINF.REINFORCE (D) (ING) RESIL.RESILIENT RET.RETURN R.A.RETURN AIR REV.REVISION (S), REVISED RM.ROOM R.O.ROUGH OPENING SCH.SCHEDULE SEC.SECOND, SECTION SHT.SHEET SIM.SIMILAR S.C.SOLID CORE S.SOUTH SPK.SPEAKER SPEC.SPECIFICATION (S) SQ.SQUARE S.Y.SQUARE YARD S.S.STAINLESS STEEL STD.STANDARD STL.STEEL STOR.STORAGE S.D.STORM DRAIN STRUCT.STRUCTURAL SUSP.SUSPENDED SYM.SYMMETRY (ICAL) SYS.SYSTEM TEL.TELEVISION TEMP.TEMPERED TERR.TERRAZZO THK.THICK (NESS) THRES.THRESHOLD TOL.TOLERANCE T&G.TONGUE AND GROOVE T.O.C.TOP OF CURB T.O.S.TOP OF SLAB T.O.STL.TOP OF STEEL T.O.W.TOP OF WALL T.TREAD TX.TRANSFORMER TYP.TYPICAL UNF.UNFINISHED U.O.N.UNLESS OTHERWISE NOTED V.B.VAPOR BARRIER VAR.VARIES, VARNISH VNR.VENEER VERT.VERTICAL VEST.VESTIBULE V.VINYL V.C.T.VINYL COMPOSITION TILE V.I.F.VERIFY IN FIELD W.T.W.WALL TO WALL W.C.WATER CLOSET WP.WATERPROOFING WS.WEATHER STRIPPING WT.WEIGHT W.W.F.WELDED WIRE FABRIC W.WEST, WIDE, WIDTH W/WITH WDW.WINDOW W.GL.WIRED GLASS W/O WITHOUT WD.WOOD W.P.WORKING POINT ABBREVIATIONS CODE DATA APPLICABLE CODES: THE FOLLOWING IS AN ANALYSIS AND SUMMARY OF THE APPLICABLE BUILDING CODES: • INTERNATIONAL BUILDING CODE (IBC)2012 EDITION • INTERNATIONAL FUEL GAS CODE (IFGC)2012 EDITION • INTERNATIONAL FIRE CODE 2012 EDITION • INTERNATIONAL MECHANICAL CODE (IMC)2012 EDITION • INTERNATIONAL PLUMBING CODE 2006 EDITION • INDIANA BUILDING CODE 2014 EDITION (IBC 2012 EDITION, 1ST PRINTING) ANSI A117.1-2009 • INDIANA ELECTRIC CODE 2009 EDITION • NATIONAL ELECTRIC CODE + INDIANA AMENDMENTS 2008 EDITION OCCUPANCY / CONSTRUCTION TYPE: • OCCUPANCY TYPE:ASSEMBLY A-2 RESTAURANT • CONSTRUCTION TYPE:TYPE V-A FULLY SPRINKLERED • CHAPTER 5 ALLOWABLE STORIES/ HEIGHT/ AREA: 1. STORIES:2 + 1 INCREASE ACTUAL: 1 STORY 2. HEIGHT:50' + 20' INCREASE ACTUAL: 25' TOP OF PARAPET 3. FLOOR AREA:11,500 SF + 200% INCREASE ACTUAL: 8,309 INTERIOR 1,043 PATIO GENERAL PROJECT NOTES 1. AIA DOCUMENTS A201 AND A101 SHALL BE PART OF THE CONTRACT DOCUMENTS. 2. ALL WORK SHALL COMPLY WITH APPLICABLE FEDERAL, LOCAL AND MUNICIPAL BUILDING AND ZONING CODES, AS WELL AS ANY AND ALL REGULATORY AGENCIES, INCLUDING, BUT NOT LIMITED TO, ANSI, OSHA, ETC. GENERAL NOTES SHALL APPLY TO ALL DRAWINGS. 3. THE TERMS "CONSTRUCTION CONTRACTOR," "GENERAL CONTRACTOR, G.C., CONSTRUCTION MANAGER/MANAGEMENT" AND "CONTRACTOR" SHALL BE UNDERSTOOD TO BE THE SAME UNLESS SPECIFICALLY NOTED OTHERWISE. 4. G.C. SHALL PROVIDE ALL THE DRAWINGS, COMPLETED PAPERWORK AND CERTIFICATES OF INSPECTION AND SHALL PERFORM ALL THE CONTROLLED INSPECTIONS AS REQUIRED FOR BUILDING DEPARTMENT SIGN OFF. 5. THE ARCHITECT AND THE OWNER RESERVES THE RIGHT TO ALLOW OTHER CONTRACTS TO PERFORM WORK IN CONNECTION WITH THE PROJECT. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF WORK AND ESTABLISHING SCHEDULES FOR ALL TRADES; THEY SHALL AFFORD OTHER CONTRACTORS REASONABLE OPPORTUNITY FOR THE INTRODUCTION AND STORAGE OF THEIR MATERIALS AND EQUIPMENT AND THE EXECUTION OF THEIR WORK. 6. DRAWINGS ARE NOT TO BE SCALED; DIMENSIONS GOVERN. 7. ALL WORK IS TO CONFORM TO THE CONTRACT DOCUMENTS AND SHALL BE NEW AND OF THE BEST QUALITY OF THE KINDS SPECIFIED. 8. ALL MATERIALS AND EQUIPMENT SPECIFIED SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, CLEANED, AND CONDITIONED AS DIRECTED BY THE SUPPLIER/MANUFACTURER, IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARD PRACTICE AND IN COMPLIANCE WITH PRODUCT WARRANTY. 9. CONSTRUCTION PERSONNEL MUST CARRY PROPER IDENTIFICATION AT ALL TIMES. 10. ALL CONSTRUCTION TOOLS AND EQUIPMENT SHALL MEET REQUIREMENTS OF OSHA AND ALL APPLICABLE REGULATORY AGENCIES. 11. GENERAL CONTRACTOR IS RESPONSIBLE TO PROTECT, AS REQUIRED, ALL OWNER OCCUPIED AREAS WHERE FINISH WORK OR GENERAL CONSTRUCTION IS TO BE PERFORMED. GENERAL CONTRACTOR TO INSTALL ADEQUATE PROTECTION OF BUILDING PAPER, MASONITE, OR OTHER APPROVED MATERIAL ON ALL FINISHED SURFACES AS DIRECTED BY THE ARCHITECT PRIOR TO THE OWNER'S MOVING DATE, AND SHALL REMOVE SAME FOLLOWING COMPLETION OF THE MOVE 12. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL COSTS INCURRED FOR DAMAGES CAUSED BY THEIR SUBCONTRACTORS. 13. ALL WORK SHALL CONFORM WITH THE REQUIREMENTS OF APPLICABLE CODES: RULES AND REGULATIONS ALL IN THEIR LATEST EDITION OF ALL AUTHORITIES HAVING JURISDICTION OVER WORK OF THIS TYPE, INCLUDING THE RULES AND REGULATIONS OF THE BUILDING MANAGEMENT. 14. SELECTION OF SUBCONTRACTORS IS SUBJECT TO THE OWNER'S REVIEW PRIOR TO AWARDING OF CONTRACT. THE GENERAL CONTRACTOR MUST SUBMIT A LIST OF THEIR PROPOSED SUBCONTRACTORS WITH THE SUBMISSION OF THIS BID, AS WELL AS EVIDENCE THAT THOSE SUBCONTRACTORS REQUESTED TO BE AFFORDED THE OPPORTUNITY TO BID HAVE HAD THAT OPPORTUNITY AND HAVE RESPONDED. 15. ALL WORK, COMPLETED OR OTHERWISE, SHALL BE PROPERLY PROTECTED AT ALL TIMES. CONTRACTOR SHALL FOLLOW ALL ACCEPTED METHODS OF SAFETY PRACTICE AND PROVIDE ALL FENCES, BARRICADES, ETC., AS MAY BE NEEDED TO PROTECT LIFE AND PROPERTY AND AS MAY BE REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER THIS WORK. THEY SHALL REPAIR, AT THEIR OWN COST, ANY DAMAGES TO THE PREMISES OR ADJACENT WORK CAUSED BY THEIR OPERATION. 16. BEFORE COMMENCING WITH ANY WORK, THE CONTRACTOR SHALL FILE WITH THE OWNER CURRENT INSURANCE CERTIFICATES IN THE AMOUNTS REQUESTED BY THE OWNER FOR WORKER'S COMPREHENSIVE GENERAL LIABILITY, BODILY INJURY AND PROPERTY DAMAGE. THE OWNER SHALL BE NAMED "ADDITIONAL INSURED" ON ALL CERTIFICATES OF INSURANCE, INCLUDING THE ARCHITECT. 17. THE CONTRACTOR SHALL GUARANTEE IN WRITTEN FORM, AS ACCEPTABLE TO THE OWNER, ALL LABOR AND MATERIALS INSTALLED BY THEM FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR AFTER DATE OF ACCEPTANCE OF THE WORK BY THE OWNER EXCEPT AS MODIFIED HEREIN OR ON OTHER DRAWINGS. SHOULD DEFECTS OCCUR, ALL WORK SHALL BE REPLACED OR PROPERLY REPAIRED AT NO ADDITIONAL COST TO THE OWNER. 18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTAL TO THE AUTHORITY HAVING JURISDICTION ANY AND ALL REVISIONS POST PERMIT APPROVAL REQUIRING REVIEW AND INCORPORATION INTO THE APPROVED CONSTRUCTION DOCUMENTS. SHEET INDEX Service Sinks PLUMBING FIXTURE COUNT Drinking Fountains Bathtubs / ShowersMale*Female Male Female CODE REQUIREMENT: REQUIRED FIXTURES: PROVIDED FIXTURES: --- ------ ** * URINALS CAN NOT BE MORE THAN 67% OF THE FIXTURES REQUIRED. ** DRINKING FOUNTAINS NOT REQUIRED, WATER TO BE SERVED. HI/LOW DRINKING FOUNTAINS OR BOTTLED WATER SERVICE REQUIRED IF WATER IS NOT SERVED. 182.5 --- 3 3 1 1 182.5182.5 182.5 ---1 --- Water Closets (1/75)Lavatories (1/200) OCCUPANCY TYPE: ASSEMBLY - A2 LEVEL: 1ST FLOOR OCCUPANTS: 365 11:1-75 1:1-75 1:1-200 1:1-200 1:1-500 4 4 2 2 0 1 1 2006 IPC OCCUPANCY RATIO: (182.5 Male (50%) / 182.5 Female (50%)) STAIR WIDTH: EGRESS WIDTH:(365 OCCUPANTS) x (0.15 WITH SPRINKLER)55"236" (365 OCCUPANTS) x (0.2 WITH SPRINKLER)73" 116" BUILDING EGRESS: (Per 1005.3) MINIMUM NUMBER OF EXITS:2 6 EXIT CAPACITY: (Per 1015.1) MINIMUM DISTANCE (1/3 DIST. OF DIAGONAL DIST. WITH SPRINKLER [141'-3"])47'-1" 51'-3" EXIT SEPARATION DISTANCE: (Per 1015.2) 250'-0" 116'-2"(WITH SPRINKLER) TRAVEL DISTANCE MAXIMUM: (Per 1016.2) (WITH SPRINKLER)75'-0" 48'-5" COMMON TRAVEL PATH MAXIMUM: (Per 1014.3) PROV.REQ'DLEVEL NAME:FIRST FLOOR OCCUPANCY TYPE: A-2 REQUIRED EGRESS AND EXITING PROJECT INFORMATION PROJECT MAP or KEY PLAN PROJECT NAME: PROJECT SCOPE: PROJECT ADDRESS: ABERDEEN 150 W. 96TH STREET INDIANAPOLIS, IN 46260 THE PROJECT INCLUDES THE INTERIOR REMOVATION OF AN EXISTING RESTAURANT. THE EXTERIOR FINISHES ARE TO BE UPDATED AND NEW EXTERIOR SIGNAGED ADDED. THE EXISTING SOUTH FACING PATIO IS TO BE ENCLOSED WITH A ROOF AND SIDEWALLS WITH OPENINGS, TO RECEIVE RETRACTABLE SCREENS. 150 W. 96TH STREET INDIANAPOLIS, IN 46260 ABERDEEN DRAWING ISSUE DATA: PERMIT 2023-05-12 SHEETS DRAWINGS 2023-05-12 PERMIT 2023-04-28 PRELIMNARY PRICINGSHT. NO. NAME ■ ■G100 TITLE SHEET ■ ■G200 ACCESSIBLE DETAILS ■G300 LIFE SAFETY PLAN ■ ■A010 SITE PLAN ■ ■D110 DEMO FLOOR PLAN ■ ■D120 DEMO CEILING PLAN ■ ■A109 FLOOR SLAB PLAN ■ ■A110 FLOOR PLAN ■ ■A120 CEILING PLAN ■ ■A130 LIGHTING PLAN A131 LIGHTING ZONING PLAN ■ ■A140 FINISH PLAN ■ ■A150 FURNITURE-EQUIPMENT PLAN ■ ■A191 FINISH SCHEDULE AND SPECIFICATIONS ■ ■A210 EXTERIOR ELEVATIONS ■ ■A240 INTERIOR ELEVATIONS ■ ■A241 INTERIOR ELEVATIONS ■ ■A310 BUILDING SECTIONS ■A320 WALL SECTIONS ■ ■A410 ENLARGED BAR PLAN - ABERDEEN ■ ■A411 ENLARGED BAR PLAN - ASH ■ ■A460 ENLARGED RESTROOM PLAN AND ELEVATIONS ■ ■A510 BUILDING AND PLAN DETAILS ■A520 SECTION DETAILS ■A540 INTERIOR DETAILS ■ ■A551 MILLWORK (MW-1) PLAN, ELEVATIONS, SECTIONS AND DETAILS ■ ■A552 MILLWORK (MW-2 & MW-3) PLAN, ELEVATIONS, SECTIONS AND DETAILS ■ ■A553 MILLWORK (MW-4) PLAN, ELEVATIONS, SECTIONS AND DETAILS ■ ■A554 MILLWORK (MW-5 & MW-6) PLAN, ELEVATIONS, SECTIONS AND DETAILS ■A555 MILLWORK (MW-7) PLAN, ELEVATIONS, SECTIONS AND DETAILS A556 MILLWORK (MW-8) PLAN, ELEVATIONS, SECTIONS AND DETAILS ■ ■A557 MILLWORK (MW-9 & MW-10) PLAN, ELEVATIONS ■A610 PARTITION TYPES AND DETAILS ■A615 DOOR SCHEDULE AND DETAILS A616 WINDOW-OPENING SCHEDULE ■S-000 COVER SHEET ■S-100 FOUNDATION PLAN ■S-101 ROOF FRAMING PLAN ■S-200 GENERAL NOTES ■S-300 TYPICAL FOUNDATION DETAILS ■S-400 FRAMING SECTIONS ADD ALTERNATES / DEDUCTS NO.DESCRIPTION 1 SUBSTITUTE MIR-1b AS A SUBSTITUTE FOR MIR-1a. 2 SUBSTITUTE WD-2b AS A SUBSTITUTE FOR WD-2a. 3 SUBSTITUTE WLC-4 AS A SUBSTITUTE FOR WD-6. 4 SUBSTITUTE PT-5 AS A SUBSTITUTE FOR SPF-1. TRUE NORTH 1 ADD ALTERNATE OCCUPANCY CALCULATIONS SPACE FUNCTION AREA OLF OCC. LOAD INTERIOR ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 833 SF 300 3 ASSEMBLY - CONCENTRATED: CHAIRS ONLY 209 SF 7 30 ASSEMBLY - STANDING SPACE 37 SF 5 8 ASSEMBLY - UNCONCENTRATED: DINING SEATING AREA (TABLES AND CHAIRS) 1,830 SF 15 122 BUSINESS AREAS 130 SF 100 2 COMMERCIAL KITCHEN 2,321 SF 200 12 5,358 SF 177 EXTERIOR ASSEMBLY - UNCONCENTRATED: DINING SEATING AREA (TABLES AND CHAIRS) 996 SF 15 67 996 SF 67 TOTAL OCCUPANTS:6,354 SF 244 DATE ISSUED REG. NO. THIS DOCUMENT IS CERTIFIED BY consultant project title seal project no. sheet title drawn client issue date checked 10 South Eighth Street Minneapolis, MN 55402 t 612_339-2257 sheadesign.com AR00910059 David A. Shea, Architect 2023-05-12 5/16/2023 4:32:56 PMC:\Revit Projects\A22_8778.00-ROOTSTOCK HOSPITALITY_briana-SHEA.rvt8778.00 NC/ BA BA TITLE SHEET G100 © 2023 shea, inc. PERMIT 2023-05-12 1ROOTSTOCK HOSPITALITY ABERDEEN 150 W. 96TH STREET INDIANAPOLIS, IN 46260 no. date issued for