Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Ceiling Plan
ABCDEFGHJKLMNP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 15 16 17 18 19 20 2 A320 _____ 1 A320 _____2'-0"101 ENTRY VESTIBULE 102 HOST / WAITING 103 COATS 104 A / V 106 LIFT 111 DINING 107 BAR DINING 01 108 BACK BAR 121 PATIO 112 FLEX 114 WOMEN'S RESTROOM 115 MEN'S RESTROOM 119 PRIVATE DINING 109 BAR DINING 02 116 EXPO EXTG B.O.H. 117 OFFICE 110 WINE 02 EXTG LIQUOR STORAGE EXTG EMPLOYEE RESTROOM EXTG MECH/ELEC 7'-11 7/8"16'-1"6'-5"13'-7 1/2"+/-2'-1 7/8"3'-6 1/4"9'-0 1/2"3'-6 1/4"3'-6 1/4"6'-7"3'-6 1/4"+/- 3'-5 1/2"24'-1 1/2" 3'-6 1/4"17'-1"3'-6 1/4" 7'-2 1/2"15'-7 1/2"8'-8 1/8" 3'-6 1/4"8'-7"3'-6 1/4"2'-6 5/8"12'-0"5'-4 3/4"33'-5"3'-6 1/4"26'-4 1/2"3'-6 1/4"1 A540 _____ 1 A540 _____ 1 A540 _____1'-0"10'-0"1'-0"18'-0"3'-11 3/4" 1'-0"16'-0"1'-0" 2 A540 _____ 1'-11 1/4"20'-0"1'-11" 1'-0"18'-0"1'-0"1'-8 7/8"10'-0"1'-8 7/8"1'-0"8'-0"1'-0"2 A540 _____ ACT-1 11' -6" (AFF)11' -6" ACT-1 11' -6" (AFF)11' -6" ACT-1 11' -6" (AFF)11' -6" ACT-2 11' -6" (AFF)11' -6" PT-2 14' -6" (AFF)14' -6"6'-0"14'-0" 9' -8" (AFF)9' -8" PT-3 11' -6" (AFF)11' -6" PT-1 11' -0" (AFF)11' -0" 1'-7 3/8"EQ28'-0"EQ3 A540 _____ ACT-2 10' -0" (AFF)10' -0" PT-2 9' -0" (AFF)9' -0" PT-4 9' -0" (AFF)9' -0" PT-4 9' -0" (AFF)9' -0" ACT-2 8' -0" (AFF)8' -0" ACT-3 8' -0" (AFF)8' -0" ACT-2 8' -0" (AFF)8' -0" ACT-2 8' -0" (AFF)8' -0" ACT-2 8' -0" (AFF)8' -0" ACT-3 8' -0" (AFF)8' -0" 1'-0 1/2"3'-0"3'-0"3'-0"3'-0"3'-0"1'-0 1/2"1'-6 1/4"3'-0"3'-0"1'-6 1/4"1'-3 1/2"3'-0"3'-0"1'-3 1/2"1'-2 1/4"3'-0"3'-0"3'-0"3'-0"3'-0"3'-0"3'-0"3'-0"1'-2 1/4"TYPR 3'-6 3/4"R 11" TYPR 11" 11 2 3 3 4 5 5 5 5 5 TYPR 3'-6 3/4"5 4 6 6 6 7 113 HALLEXTG COOLER EXTG FREEZER EXTG FREEZER 120 BACK BAR 118 ENTRY EXTG DRY STORAGE EXTG COOKLINE EXTG WARE WASHING 7 7 88 8 10 10 11 SPF-1 12' -6" (AFF)12' -6" SPF-1 12' -6" (AFF)12' -6" SPF-1 13' -6" (AFF)13' -6" 12 16'-4"2'-0"13'-7"18'-7 1/2"3'-11 1/2"4'-8"20'-3"14'-5"1'-4"13'-4"5'-2"3'-0"4'-8"1'-4"3'-8"1'-4"2'-0"1'-0"5'-10"5'-3"9'-0"4'-10"5'-4"13'-11"3'-1"11'-11"11 1/2"5'-2 1/2"1'-4"5'-2"1'-4"9'-0"5'-0"86'-6"121'-4" 8 A510 _____ 7 A510 _____ 4 A615 _____ PT-6 15' -6" (AFF)15' -6" CEILING PLAN NOTES 1. DO NOT SCALE OFF OF PLANS. CONTACT ARCHITECT WITH DIMENSION QUESTIONS. 2. SEE M.E.P. DRAWINGS (OR DESIGN BUILD M.E.P. AS APPLICABLE) FOR SPECIFICATIONS AND CONFIGURATION OF MECHANICAL, ELECTRICAL AND PLUMBING ITEMS. 3. VERIFY ALL REQUIRED ACCESS PANEL SIZES AND LOCATIONS AT GYP. BD. CEILINGS. PROVIDE FLUSH ACCESS PANELS AT ALL EQUIPMENT, VALVES, DAMPERS, CONTROLS CLEAN OUTS, ETC. PAINT TO MATCH CEILING FINISH. 4. ALL CEILING MATERIAL MUST HAVE CLASS "A" FIRE RATING. 5. SUPPORT WIRES FOR CEILING SUSPENSION SHALL BE ANCHORED TO STRUCTURE ABOVE AND AS REQUIRED BY LANDLORD. SUPPORT WIRES SHALL NOT BE CONNECTED TO ANY MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT. 6. SPRINKLER HEADS AT GYPSUM BOARD CEILINGS MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. 7. CENTER SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, AND OTHER RECESSED OR SURFACE MOUNTED ITEMS IN CEILING TILES. 8. PAINT OUT ALL DIFFUSERS, SPEAKERS, TRIM RINGS, AND EXPOSED DUCTS TO MATCH CEILING FINISH. 9. ALL GYP. BD.. CEILINGS AND SOFFITS SHALL HAVE LEVEL 5 FINISH AND SHALL BE PAINTED. 10. WHERE PORTION OF EXISTING CEILING OR SOFFIT HAS BEEN IMPACTED BY DEMOLITION, PATCH, REFINISH OR REPLACE EXISTING CEILING AS REQUIRED TO MATCH EXISTING CONDITION, UNLESS NOTED OTHERWISE. 11. SEE FINISH PLAN FOR FINISH SPECIFICATIONS. 12. CENTER CEILING GRID IN ROOM UNLESS NOTED OTHERWISE. 13. FIRE SPRINKLER SYSTEM SHALL REMAIN OPERATIONAL THROUGHOUT THE BUILDING DURING THE PROJECT. WHEN TAKEN OUT OF SERVICE FOR TENANT WORK, A FIRE WATCH IS REQUIRED IN AREAS OF THE BUILDING AFFECTED BY THE SHUTDOWN. 14. G.C. TO FIELD VERIFY EXISTING CONDITIONS AND CLEARANCES ABOVE CEILINGS PRIOR TO ORDERING LIGHT FIXTURES. NOTIFY ARCHITECT OF ANY CONFLICT BETWEEN EXISTING CONDITIONS AND NEW LIGHT FIXTURES. CEILING PLAN NOTESCEILING PLAN SYMBOLS SEE A191 FOR INFO DESCRIPTION 48x96 GRIDACT-1 EXISTING TO REMAIN, PATCH/REPAIR AS REQ'D 24x48 GRID,WASHABLE/SCRUBBABLEACT-2 SYMBOL SEE A191 FOR INFO WOODEXT-12 EXISTING TO REMAIN, PATCH/REPAIR AS REQ'D 24x24 GRID,WASHABLE/SCRUBBABLEACT-3 LEVEL 5 FINISH, PAINT GYPSUM BOARDGYP. BD. (NOT ALL KEYNOTES MAY BE USED ON THIS SHEET) CEILING KEY NOTES NO.DESCRIPTION REV. 1 CANOPY OVER MAIN ENTRY DOORS. SEE DETAILS AND STRUCTURAL ENGINEERING. 2 EXISTING GYP CEILING TO REMAIN. PATCH ND REPAIR AS NEEDED AFTER INSTALLATIONS OF NEW LIGHTING. PREPARE FOR NEW PAINT FINISH. 3 WALLS AT HOST/ WAITING, COATS, LIFT, AND WINE ROOMS DO NOT EXTEND TO CEILING. ACT CEILING AND COFFER TO BE CONTINUOUS ACROSS THESE AREAS INTO BAR AND DINING SPACES. 4 COFFERED CEILING WITH WOOD TRIM. SEE DETAIL FOR TYPICAL CONSTRUCTION AND FINISHES. 5 ARCHED COFFER WITH WOOD RIBS AND TRIM AT CEILING. SEE DETAIL FOR TYPICAL CONSTRUCTION AND FINISHES. 6 OVERBAR SHELVING SYSTEM BELOW CEILING. SEE BAR PLAN FOR CONSTRUCTION DETAILS AND FINISHES. 7 NO FINISHED CEILING THIS AREA. CLEAR AREA OF ABANDONED UTILITIES DUE TO REMOVAL OF PREVIOUS EQUIPMENT. PREPARE SURFACES TO RECEIVE NEW FINISH. 8 EXISTING WOOD TRUSS AND STEEL BEAM STRUCTURE ABOVE TO REMAIN. PREPARE TO RECEIVE NEW FINISH. 10 EXISTING EXHAUST HOOD(S) TO REMAIN. 11 NO FINISHED CEILING IN EXISTING MECHANICAL ROOM. 12 NO FINISHED CEILING BETWEEN WALLS ABOVE SERVER NICHE SCALE: 1/4" = 1'-0"A120 1 CEILING PLAN DATE ISSUED REG. NO. THIS DOCUMENT IS CERTIFIED BY consultant project title seal project no. sheet title drawn client issue date checked 10 South Eighth Street Minneapolis, MN 55402 t 612_339-2257 sheadesign.com AR00910059 David A. Shea, Architect 2023-05-12 5/16/2023 4:29:36 PMC:\Revit Projects\A22_8778.00-ROOTSTOCK HOSPITALITY_briana-SHEA.rvt8778.00 NC/ JF BA CEILING PLAN A120 © 2023 shea, inc. PERMIT 2023-05-12 9ROOTSTOCK HOSPITALITY ABERDEEN 150 W. 96TH STREET INDIANAPOLIS, IN 46260 PROJECT NORTH TRUE NORTH no. date issued for