Loading...
HomeMy WebLinkAbout06090013 As Built ~~ Schneider This Pial Plan Prepared For: Pulle Homes Townhomes 01 GuDford Instrumenl # 200500080749 SEe 36. T1aN. R3E HomDlon Counly. Clay Twp. Clly of Carmel Block 8 Prepared Dole: 05/15/2006 : By: AMA The Schneider Corporation 8901 Otis AvenUll Historic Fort Harrison Indianapolis, Indiana 48216-1037 317-826-7100 317-826-7200 FAX -- Sun."", Landscape Arclrlleet.ure ms'Illl _'BY Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; foning to do so results in the contractors assumption of all liability. Plot Pion Legend []QQ]] Proposed Grades ' 000.0 Existing Grades __000,0- Contour Grode * Approx. Lateral Location - . - Sanitary Sewer Lines -IT - Storm Sewer Lines - 'W - Water Service Lines - - - ~ - - - Sub-Surface Drain Unes - - ~ -.~Manhole(Sonita-ry-or Sto-m) . Beehive Inlet (Storm) 11III Curb Inlet (Storm) D End Seclion (Storm) ..... Fire Hydrant - 000 - 000 - Flow Line of swale - Building Une (BL / BSL) - - - - - - - Easement Line BLOCK 8 Pulte Homes Finished Floor Elevation Information PAD=849.21 FFE=849.71 a _~_~- '~H =~= ~ Assumed North Scole : 1" = 30' Nate; Sanitary Sewer Top of Costing Information Upstreom Monhole, TC= 849.40 Downstreom Manhole, TC= 849.90 per plan. 24.15 SLAB 2510 # 801 ~mr&: t.lSY ~ .... RESIDENCE ~ SlAB LOT # - ADDRESS 801 - 772 Ivy Lane 802 778 Ivy Lane 803 784 Ivy Lane 804 790 Ivy Lane 1805 796 Ivy Lane ~ t ~ 26.00' COMMON AREA "A" DU&SE POND 3 NP=841.60 100 YR =845.17 23.96' 23.96' 23.96' t 10.5' 10.S' t 10.5' to 23.96 23.96 "23.96 ;;j SlAB StAB SLAB '2391 # 802 # 803 2391 # 804 v.rSTlEY 2510 Vt{STlEY fRld &: MSY ....... mER ....... FRId &: I.lSY t; RESIDENCE ~ FRM &: MSY ~ RESIDENCE C"l .... tJESlOENCE .... (0 .... <0 <0 TWO CAR ~ TWO CAR ~ GARAGE: GARAGE 23.58' ~ 24.33' 16' I ORIVE '::! '" 10.5' I TC=849.90 PER PLAN . <: 848. 3 TC-646.32 PER PLAN \ STR.# 408 6. 0 TC=849.40 PER PLAN ESI.lT. 10=846.32 ER PLAN .. NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1. :i " '0 I ;... FLOOO HAZARD STATEMENT CERTIFICATION ~\\\\\\\\\\111111J//1!11111//, #\'\ t. L j1llij~ i-\i .,:,.':~ . ,,;.0//'" ~ lo.~'\ ............. 'T(/L....~ ~ ~...~(,\S T~~~,...'Y;<:>% i ">....Qc SON3003 "\,-<') ~ ". STATE OF.. i2 '\ <;;~,,:,IyD' A~!':,""~f ~,~ "S""U'o';iCI.: 4' ~///, 1\ '( \..~\\"0..:s:. 11111II1II!1I11I\\\\\\\\\\\ ~L~ \.1 TYPICAL SWALE SECTlON Note; The contractor is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water line laterals. FlOOD HAZARD STATEMENT: The accuracy of any flood hazard data shown on this report is subject to mop scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rote map (FIRM), ALL of the within described land DOES NOT UE within that special flood hazard zone A as said land plots by scale on flood insurance rote map # 18057C0209F for Hamilton County, Indiono (mop effective dote Februory 19, 2003).