Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Summerfield CR201
LEFT 2009.300 CZ 0.10 Summerfield BASE BUILDING CODE: . FIRE CODE: . ELECTRICAL CODE: . ENERGY CODE: . PLUMBING CODE: . MECHANICAL CODE: . MUNICIPAL CODE: . APPLICABLE CODES SHEET INDEX . . . . . . Mulhern & Kulp Engineers 300 Brookside Ave. Building 4, Suite 150 Ambler, PA 19002 215.646.8001 www.mulhernkulp.com MUNICIPALITYARCHITECT OF RECORD STRUCT. ENGINEER ZONING ORDINANCE: . USE GROUP: One & Two Family dwelling CONSTRUCTION CLASS: Unprotected Frame HEIGHT & AREA: . OTHER REQUIREMENTS: . MECH. ENGINEER BUILDING CODE ANALYSIS . . . . . . . . . . . . Sheet No. Sheet Description CZ 0.10 Cover Sheet / Project Information / Sheet Index CZ 0.20 Cover Sheet / General Notes / Abbreviations CZ 0.30 Cover Sheet / Revision Log ARCHITECTURAL DRAWINGS A0 S-1.1 Slab Utility Plan A0 SB-1.1 Slab Utility Plan w/ Masonry Wrap A0 B-1.1 Basement Foundation Plan - 9'-0" Basement A0 BB-1.1 Basement Foundation Plan w/ Masonry Wrap - 9'-0" Basement A1 0.1 Finished Basement Floor Plan A1 0.2 Finished Basement Floor Plan / Options A1 4-1.1 First Floor Plan / _ / 2x4 Exterior Walls A1 4-1.2 First Floor Plan / Options / 2x4 Exterior Walls A1 4-2.1 Second Floor Plan / _ / 2x4 Exterior Walls A1 4-2.2 Second Floor Plan / Options / 2x4 Exterior Walls A1 4-2.3 Second Floor Plan / Options / 2x4 Exterior Walls A2 S.1 Building Section 1 / _ / Slab Foundation A2 S.2 Building Section 2 / _ / Slab Foundation A2 S.3 Building Section 2 w/ Bath 3 Extension / _ / Slab Foundation A2 B.1 Building Section 1 / _ / Basement Foundation A2 B.2 Building Section 2 / _ / Basement Foundation A2 B.3 Building Section 2 w/ Bath 3 Extension / _ / Basement Foundation A3 CR201 2RS.1 Craftsman 201 / 2 Car Rear Entry / Front, Side and Rear Elevations, Roof Plan and Ventilation Schedule A3 CR201 2RS.2 Craftsman 201 / 2 Car Rear Entry / Partial Slab Foundation Plan A3 CR201 2RB.2 Craftsman 201 / 2 Car Rear Entry / Partial Basement Foundation Plan A3 CR201 2RS4.3 Craftsman 201 / 2 Car Rear Entry / Partial Floor Plan - 2x4 Exterior Walls ****All Elevation Follow The A3 Sheet Numbering Used For The Craftsman 201 Elevations Above A4 CP4S.1 Covered Patio Option - Slab / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CP4I.1 Covered Patio Option - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4S.1 4' Garage Extension Option - Slab / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4S.2 4' Garage Extension Option - Slab w/ Masonry Wrap / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4I.1 4' Garage Extension Option - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4I.2 4' Garage Extension Option - In-Grade Basement w/ Masonry Wrap / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4S.1 Covered Patio w/ 4' Garage Extension Option - Slab / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4S.2 Covered Patio w/ 4' Garage Extension Option - Slab w/ Masonry Wrap / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4I.1 Covered Patio w/ 4' Garage Extension Option - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4I.2 Covered Patio w/ 4' Garage Extension Option - In-Grade Basement w/ Masonry Wrap / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls Sheet No.Sheet Description UTILITY DRAWINGS U0 B-1.10 Basement Utility Plan / _ / All Basement Walls U1 0.10 Finished Basement Utility Plans / _ / All Basement Walls U1 0.20 Finished Basement Utility Plans / Options / All Walls U1 0.21 Finished Basement Utility Plans / Options - Optional Lighting Package / All Walls U1 4-1.10 First Floor Utility Plan / _ / 2x4 Exterior Walls U1 4-1.11 First Floor Utility Plan / Optional Lighting Package / 2x4 Exterior Walls U1 4-1.20 First Floor Utility Plan / Options / 2x4 Exterior Walls U1 4-1.21 First Floor Utility Plan / Options - Optional Lighting Package / 2x4 Exterior Walls U1 4-2.10 Second Floor Utility Plan / _ / 2x4 Exterior Walls U1 4-2.11 Second Floor Utility Plan / Optional Lighting Package / 2x4 Exterior Walls U1 4-2.20 Second Floor Utility Plan / Options / 2x4 Exterior Walls U1 4-2.21 Second Floor Utility Plan / Options - Optional Lighting Package / 2x4 Exterior Walls U1 4-2.30 Second Floor Utility Plan / Options / 2x4 Exterior Walls U1 4-2.31 Second Floor Utility Plan / Options - Optional Lighting Package / 2x4 Exterior Walls FLOORING DRAWINGS FL 0.1 Finished Basement Flooring Plan / _ / All Basement Walls FL 0.2 Finished Basement Flooring Plan / Options / All Basement Walls FL 4-1.1 First Floor Flooring Plan / _ / 2x4 Exterior Walls FL 4-1.2 First Floor Flooring Plan / Options / 2x4 Exterior Walls FL 4-2.1 Second Floor Flooring Plan / _ / 2x4 Exterior Walls FL 4-2.2 Second Floor Flooring Plan / Options / 2x4 Exterior Walls FL 4-2.3 Second Floor Flooring Plan / Options / 2x4 Exterior Walls TRIM OPTION LAYOUTS TR 4-1.1 First Floor Plan / Trim Option Layouts / 2x4 Exterior Walls TR 4-1.2 First Floor Plan - Options / Trim Option Layouts / 2x4 Exterior Walls TR 4-2.1 Second Floor Plan / Trim Option Layouts / 2x4 Exterior Walls TR 4-2.2 Second Floor Plan Options / Trim Option Layouts / 2x4 Exterior Walls ARCHITECTURAL DETAILS AD SHEETS Typical Architectural Details STRUCTURAL DRAWINGS S-0 Sheets Structural Notes S-1 Sheets Foundation & First Floor Framing Plans S-2 Sheets Second Floor Framing Plans S-3 Sheets Roof Framing Plans S-4 Sheets Framing Details S0-1 Sheets Plan Options S0-2 Sheets Plan Options S0-3 Sheets Deck Framing Plans STRUCTURAL DETAILS SD Sheets Structural Details NORTH AREA 1900 EAST GOLF ROAD - SUITE 300 - SCHAUMBURG, IL 60173 LEFT 2009.300 ATTIC VENT SCHEDULE CR201 2-CAR REAR ENTRY ROOF AREA 'A' ROOF AREA 'B' ROOF AREA 'C' ATTIC AREA (SF)2013 TOTAL NET FREE VENTED AREA REQ.966 IN2 LOW - REQUIRED (*) 483 IN2 LOW - ACTUAL w/ EAVE VENTS (**) 504 IN2 18 EAVE VENTS LOW - ACTUAL w/ CONTINUOUS VENTED SOFFITS (**) 490 IN2 49 LINEAR FEET HIGH - REQUIRED (*) 483 IN2 HIGH - ACTUAL w/ POT VENTS (***) 488 IN2 8 VENTS HIGH - ACTUAL w/ CONT. RIDGE VENTS (***) 486 IN2 27 LF * REQUIRED NET FREE VENTED AREA IS CALCULATED BY MULTIPLYING THE ATTIC AREA (FT 2) BY 1/300 AND THEN MULTIPLYING BY 144 (CONVERTING FT 2 TO IN2). 50% OF TOTAL NET FREE VENTED AREA IS REQUIRED NEAR THE RIDGE (HIGH) AND 50% IS REQUIRED AT THE SOFFIT (LOW). WHEN BOTH (HIGH) & (LOW) AREN'T PROVIDED, THE REQ'D NET FREE AREA IS 1/150 OF THE ACTUAL AREA INSTEAD. ** ACTUAL NET FREE VENTED SOFFIT AREA IS CALCULATED BY DIVIDING THE REQUIRED (LOW) AREA BY THE MFRS STATED ACTUAL VENTED NET FREE AREA PER VENT: LOW OPT 1: EAVE VENTS = 28.0 IN 2/VENT (OR) LOW OPT 2: CONT. VENTED SOFFITS = 10.0 IN 2/LINEAR FT *** ACTUAL NET FREE VENTED RIDGE AREA IS CALCULATED BY DIVIDING THE REQUIRED (HIGH) AREA BY THE MFRS STATED ACTUAL VENTED NET AREA PER VENT: HIGH OPT 1: POT ROOF VENTS = 61.0 IN 2/VENT (OR) HIGH OPT 2: CONT. RIDGE VENTS = 18.0 IN 2/LINEAR FT AMBLESIDE: Grids 4 Sides are Required per PUD 4:12 4 4 3060 3053 3053 3053 3060 2040 DO NOT Black Out Windows. Questions, Call ZBitt 3060 3060 3060 3060 2040 3040 4010 3053 3053 ~ 25' - 1 1/8''3060 3053 3060 3060 3060 2040 2040 2040 3053 CR 201 Architectural Style: CRAFTSMAN 12" 06/08/23