Loading...
HomeMy WebLinkAboutWoodview PR201LEFT 2010.300 CZ 0.10 Woodview BASE BUILDING CODE: . FIRE CODE: . ELECTRICAL CODE: . ENERGY CODE: . PLUMBING CODE: . MECHANICAL CODE: . MUNICIPAL CODE: . APPLICABLE CODES SHEET INDEX . . . . . . Mulhern & Kulp Engineers 300 Brookside Ave. Building 4, Suite 150 Ambler, PA 19002 215.646.8001 www.mulhernkulp.com MUNICIPALITYARCHITECT OF RECORD STRUCT. ENGINEER ZONING ORDINANCE: . USE GROUP: One & Two Family dwelling CONSTRUCTION CLASS: Unprotected Frame HEIGHT & AREA: . OTHER REQUIREMENTS: . MECH. ENGINEER BUILDING CODE ANALYSIS . . . . . . . . . . . . Sheet No. Sheet Description CZ 0.10 Cover Sheet / Project Information / Sheet Index CZ 0.20 Cover Sheet / General Notes / Abbreviations CZ 0.30 Cover Sheet / Revision Log ARCHITECTURAL DRAWINGS A0 S-1.1 Slab Utility Plan A0 SB-1.1 Slab Utility Plan w/ Masonry Wrap A0 B-1.1 Basement Foundation Plan - 9'-0" Basement A0 BB-1.1 Basement Foundation Plan w/ Masonry Wrap - 9'-0" Basement A1 0.1 Finished Basement Floor Plan A1 0.2 Finished Basement Floor Plan / Options A1 4-1.1 First Floor Plan / _ / 2x4 Exterior Walls A1 4-1.2 First Floor Plan / Options / 2x4 Exterior Walls A1 4-2.1 Second Floor Plan / _ / 2x4 Exterior Walls A1 4-2.2 Second Floor Plan / Options / 2x4 Exterior Walls A2 S.1 Building Section 1 / _ / Slab Foundation A2 S.2 Building Section 2 / _ / Slab Foundation A2 S.3 Building Section 3 / _ / Slab Foundation A2 B.1 Building Section 1 / _ / Basement Foundation A2 B.2 Building Section 2 / _ / Basement Foundation A2 B.3 Building Section 3 / _ / Basement Foundation A3 CR201 2FS.1 Craftsman 201 / 2 Car Rear Entry / Front, Side and Rear Elevations, Roof Plan and Ventilation Schedule A3 CR201 2FS.2 Craftsman 201 / 2 Car Rear Entry / Partial Slab Foundation Plan A3 CR201 2FB.2 Craftsman 201 / 2 Car Rear Entry / Partial Basement Foundation Plan A3 CR201 2FS4.3 Craftsman 201 / 2 Car Rear Entry / Partial Floor Plan - 2x4 Exterior Walls ****All Elevation Follow The A3 Sheet Numbering Used For The Craftsman 201 Elevations Above A4 CP4S.1 Covered Patio - Slab / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CP4I.1 Covered Patio - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4S.1 4' Garage Extension - Slab / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4I.1 4' Garage Extension - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4S.1 Covered Patio w/ 4' Garage Extension - Slab/ Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4I.1 Covered Patio w/ 4' Garage Extension - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls UTILITY DRAWINGS U0 B-1.10 Basement Utility Plan / _ / All Basement Walls U1 0.10 Finished Basement Utility Plans / _ / All Basement Walls U1 0.20 Finished Basement Utility Plans / Options / All Walls U1 0.21 Finished Basement Utility Plans / Options - Optional Lighting Package / All Walls U1 4-1.10 First Floor Utility Plan / _ / 2x4 Exterior Walls U1 4-1.11 First Floor Utility Plan / Optional Lighting Package / 2x4 Exterior Walls U1 4-1.20 First Floor Utility Plan / Options / 2x4 Exterior Walls U1 4-1.21 First Floor Utility Plan / Options - Optional Lighting Package / 2x4 Exterior Walls U1 4-2.10 Second Floor Utility Plan / _ / 2x4 Exterior Walls U1 4-2.11 Second Floor Utility Plan / Optional Lighting Package /2x4 Exterior Walls Sheet No. Sheet Description U1 4-2.20 Second Floor Utility Plan / Options / 2x4 Exterior Walls U1 4-2.21 Second Floor Utility Plan / Options - Optional Lighting Package /2x4 Exterior Walls FLOORING DRAWINGS FL 0.1 Finished Basement Flooring Plan / _ / All Basement Walls FL 0.2 Finished Basement Flooring Plan / Options / All Basement Walls FL 4-1.1 First Floor Flooring Plan / _ / 2x4 Exterior Walls FL 4-1.2 First Floor Flooring Plan / Options / 2x4 Exterior Walls FL 4-2.1 Second Floor Flooring Plan / _ / 2x4 Exterior Walls FL 4-2.2 Second Floor Flooring Plan / Options / 2x4 Exterior Walls TRIM OPTION LAYOUTS TR 4-1.1 First Floor Plan / Trim Option Layouts / 2x4 Exterior Walls TR 4-2.1 Second Floor Plan / Trim Option Layouts / 2x4 Exterior Walls ARCHITECTURAL DETAILS AD SHEETS Typical Architectural Details STRUCTURAL DRAWINGS S-0 Sheets Structural Notes S-1 Sheets Foundation & First Floor Framing Plans S-2 Sheets Second Floor Framing Plans S-3 Sheets Roof Framing Plans S-4 Sheets Framing Details S0-1 Sheets Plan Options S0-2 Sheets Plan Options S0-3 Sheets Deck Framing Plans STRUCTURAL DETAILS SD Sheets Structural Details NORTH AREA 1900 EAST GOLF ROAD - SUITE 300 - SCHAUMBURG, IL 60173 LEFT 2010.300 ATTIC VENT SCHEDULE PR201 2-CAR REAR ENTRY ROOF AREA 'A' ROOF AREA 'B' ATTIC AREA (SF)1898 176 TOTAL NET FREE VENTED AREA REQ.911 IN2 84 IN2 LOW - REQUIRED (*) 456 IN2 42 IN2 LOW - ACTUAL w/ EAVE VENTS (**) 476 IN2 17 EAVE VENTS 56 IN2 2 EAVE VENTS LOW - ACTUAL w/ CONTINUOUS VENTED SOFFITS (**) 460 IN2 46 LINEAR FEET 50 IN2 5 LINEAR FEET HIGH - REQUIRED (*) 456 IN2 42 IN2 HIGH - ACTUAL w/ POT VENTS (***) 488 IN2 8 VENTS 61 IN2 1 VENTS HIGH - ACTUAL w/ CONT. RIDGE VENTS (***) 468 IN2 26 LF 54 IN2 3 LF * REQUIRED NET FREE VENTED AREA IS CALCULATED BY MULTIPLYING THE ATTIC AREA (FT 2) BY 1/300 AND THEN MULTIPLYING BY 144 (CONVERTING FT 2 TO IN2). 50% OF TOTAL NET FREE VENTED AREA IS REQUIRED NEAR THE RIDGE (HIGH) AND 50% IS REQUIRED AT THE SOFFIT (LOW). WHEN BOTH (HIGH) & (LOW) AREN'T PROVIDED, THE REQ'D NET FREE AREA IS 1/150 OF THE ACTUAL AREA INSTEAD. ** ACTUAL NET FREE VENTED SOFFIT AREA IS CALCULATED BY DIVIDING THE REQUIRED (LOW) AREA BY THE MFRS STATED ACTUAL VENTED NET FREE AREA PER VENT: LOW OPT 1: EAVE VENTS = 28.0 IN 2/VENT (OR) LOW OPT 2: CONT. VENTED SOFFITS = 10.0 IN 2/LINEAR FT *** ACTUAL NET FREE VENTED RIDGE AREA IS CALCULATED BY DIVIDING THE REQUIRED (HIGH) AREA BY THE MFRS STATED ACTUAL VENTED NET AREA PER VENT: HIGH OPT 1: POT ROOF VENTS = 61.0 IN 2/VENT (OR) HIGH OPT 2: CONT. RIDGE VENTS = 18.0 IN 2/LINEAR FT RIGHT AMBLESIDE: Grids 4 Sides are Required per PUD 4 4 4:12 4:12HORIZONTAL SIDING, PER SPEC HORIZONTAL SIDING w/ ACCENT COLOR, PER SPEC 2040 3060 3053 3053 3053 3053 3060 DO NOT Black Out Windows. Questions, Call ZBitt 3060 3060 3060 3053 3053 4020 30603060 3053 3053 ~ 23' - 8 1/4''PR 201 Architectural Style: PRAIRIE 2040 2040 3060 3060 3053 3053 3060 3060 3053 3053 06/08/23