Loading...
HomeMy WebLinkAbout06090139 Site Plan PLOT PLAN LOT # 14 DRAWING NOT TO BE SCALED. DIMENSIONS PREY ALENT PROPOSED FINISHED FLOOR ELEVATION HOUSE: 906.9 SE AR PROPOSED FINISHED FLOOR ELEV A nON BASEMENT: 898.4 PROPOSED ELEVATION OF LOWEST OPENING OF WINDOW WELLS: 901.6 000.0 - PRECONSTRUCTION GRADE I 000.0 1- PROPOSED GRADE Cass Estates I HAMILTON COUNTY, INDIANA Section 1 4000 Andretti Drive ZONING: SIDE 7' Min./19' Agg. REAR 20' Model: 149.2124 SOD: 635:!: Sq. Y ds. Hydroseccl Area: 5,115:!: Sq.!'t. HOUSE WALK: 56:!: Sq. Y cis. DRIVE/APRON: 713:!: Sq. Yds. CITY WALK: 413 :!: Sq. Yds. PATIO/STOOP: 11O:!: Sq. Yds. W/ Steps SERVICE DOOR STOOP: 9:!: Sq. Yds. NOTE: VERWY SANTIARY LATERAL LOCATION PRIOR TO DRIVE CONSTRUCTION. NOTE: REFERENCE CERTIFICATE OF CORRECTION: INSTR. # 200500067046 FOR CORRECTED BEARINGS AND EASEMENTS ON MONTOYA DRIVE. CA#1 VAR. O.&U.E. & L.MAE. & PAE. Elevation "B" Brick Per Elevation Plan & Options Sheet Garage Storage Option Standard Basement Patio Garage Service Door WI 3'x3' Stoop No Fireplace . Front Porch~With Footings- ~ , Fun Basement Option ~'O1 --- ------ :> DRNG. FLOW ~ - WINDOW WELL ------ f,' AA"'C-______ \,\1~o~ ------ 'O'AA"t:.. \,\1~O\~ \ 'Ordi-- ------ 903.5 903.5 100.72' Lot 14 14,134 Sq. Ft. ~.D.~ 903.6 '" ~ o n CAUTION: ~i r-= I ~I INSTALL WATER LATERAL PRIOR TO DRIVE CONSTRUCTION. .r: +' ... o Z b M . . . "' E + B "' i I I - I. m *w "m Sump Pump Connection 5' Sidew k 120" ood' Sun' Deck ;: Room" 3 :! 8'0" o If) CD ",0 :..-m ......> o Q) -' - W '0 <1l 0.. Scale: 1" = 30' Job No. 06-0464 Date: 9-19-06 Drawn By : JEC Revision Date: 9-21-06 Revised: Sunroam, Deck, etc.., .1 '" 18'6-112" As. Built ' Location \"') Proposed Drive '" NOTE: TIllS DRAWING IS NOT INfENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROtITE SURVEY OR A SURVEYOR LOCATION REPORT. NOTE: IT SHALL BE TIlE RESPONSffiILITY OF TIlE BUILDERlCQNTRAcrDR TO VERIFY TIlE BUll..OING DIMENSIONS, BUll..OJNG LOCATIONS, THE LOCA nON OF OTHER PERTINENT PEA TURES. ELBV A nONS, AND ALL UNDER GROUND UTILITIES (HOLEY MOLEY 1-800-382-5544) PRIOR TO TIlE START OF CONSTRUCTION. TIm INTENDED USE OF TJ-HS PLOT PLAN IS POR SECURING BUILDING PERMITS ONLY AND SHALL NOT BE USED FOR ANY OTHER PURPOSE. NOTE: I. the undersigned. hereby certify IT (5 TIlE RESPONSIBILITY OF TIlE CONTRACfOR TO VERIFY that the within Plot Plan was ALL HOUSE DIMENSION. CENTER LINES, PATIO/HOUSE prepared under my supervision OmONS ETC... WITH THE START PACK. THE T. WRIGHT utilizing information taken from CORPORATION HOLDS NO LIABILITY FOR CONFLICTING INFO. the Development Plan prepared by others for this subdivision and, to the best of my knowledge and belief. if the finished grades are constructed as shown, the surface drainage will be satisfactory for residential construction. ,. Andretti Drive 50' RIW (30' Pvmt.) M.H. # 717 T.C.: 904.36 Inv.: 897.24 Sanitary Sewer Certified; September 19. 2006 :\\\\\\lIII/111II/. #~ D.W:?/~ ~ ~..~.,srr~('. ~ ~ ::::::J...:.:" N D "."/- ~ _' o. ..- - - = 9700013 = ~ M.H. #716 T.e.: 907.68 Inv.: 896.43 o 15', 30' ~~...,.~ GRAPHIC SCALE IN FEET - ~ STATE OF -' ~ ~<: .!(-s ~"11-'~.D'..~~-\,O ~ ~/. D SUR'-l~ #' 1'11111111\1\\\\\'\ T. WRIGHT CORP. LAND SURVEYING SERVICES 360 S, Madison Avenue, Suite 108 Greenwood, Indiana 46142 Phone (317) 885-9900 Fax (317) 885-7076 twrightcorp.com