HomeMy WebLinkAbout06090139 Site Plan
PLOT PLAN
LOT # 14
DRAWING NOT TO BE SCALED. DIMENSIONS PREY ALENT
PROPOSED FINISHED FLOOR ELEVATION HOUSE: 906.9
SE AR
PROPOSED FINISHED FLOOR ELEV A nON BASEMENT: 898.4
PROPOSED ELEVATION OF LOWEST OPENING OF WINDOW WELLS: 901.6
000.0 - PRECONSTRUCTION GRADE
I 000.0 1- PROPOSED GRADE
Cass Estates
I
HAMILTON COUNTY, INDIANA
Section 1
4000 Andretti Drive
ZONING: SIDE 7' Min./19' Agg. REAR 20'
Model: 149.2124
SOD: 635:!: Sq. Y ds.
Hydroseccl Area: 5,115:!: Sq.!'t.
HOUSE WALK: 56:!: Sq. Y cis.
DRIVE/APRON: 713:!: Sq. Yds.
CITY WALK: 413 :!: Sq. Yds.
PATIO/STOOP: 11O:!: Sq. Yds. W/ Steps
SERVICE DOOR STOOP: 9:!: Sq. Yds.
NOTE:
VERWY SANTIARY LATERAL LOCATION
PRIOR TO DRIVE CONSTRUCTION.
NOTE:
REFERENCE CERTIFICATE OF
CORRECTION: INSTR. # 200500067046
FOR CORRECTED BEARINGS AND
EASEMENTS ON MONTOYA DRIVE.
CA#1
VAR. O.&U.E. &
L.MAE. & PAE.
Elevation "B"
Brick Per Elevation Plan & Options Sheet
Garage Storage Option
Standard Basement Patio
Garage Service Door WI 3'x3' Stoop
No Fireplace .
Front Porch~With Footings- ~ ,
Fun Basement Option ~'O1 ---
------
:> DRNG. FLOW
~ - WINDOW WELL
------
f,' AA"'C-______
\,\1~o~
------
'O'AA"t:..
\,\1~O\~
\ 'Ordi--
------ 903.5
903.5
100.72'
Lot 14
14,134 Sq. Ft.
~.D.~
903.6
'"
~
o
n
CAUTION:
~i
r-=
I
~I
INSTALL WATER LATERAL
PRIOR TO DRIVE CONSTRUCTION.
.r:
+'
...
o
Z
b
M
.
.
.
"'
E +
B
"'
i
I
I
-
I. m
*w
"m
Sump Pump
Connection
5' Sidew k
120" ood'
Sun' Deck ;:
Room" 3 :!
8'0"
o
If)
CD
",0
:..-m
......>
o Q)
-' -
W
'0
<1l
0..
Scale: 1" = 30'
Job No. 06-0464
Date: 9-19-06
Drawn By : JEC
Revision Date: 9-21-06
Revised: Sunroam, Deck, etc..,
.1
'"
18'6-112"
As. Built '
Location
\"') Proposed
Drive
'"
NOTE:
TIllS DRAWING IS NOT INfENDED TO BE REPRESENTED
AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY,
A ROtITE SURVEY OR A SURVEYOR LOCATION REPORT.
NOTE:
IT SHALL BE TIlE RESPONSffiILITY OF TIlE BUILDERlCQNTRAcrDR
TO VERIFY TIlE BUll..OING DIMENSIONS, BUll..OJNG LOCATIONS, THE
LOCA nON OF OTHER PERTINENT PEA TURES. ELBV A nONS, AND ALL
UNDER GROUND UTILITIES (HOLEY MOLEY 1-800-382-5544) PRIOR TO
TIlE START OF CONSTRUCTION. TIm INTENDED USE OF TJ-HS PLOT PLAN
IS POR SECURING BUILDING PERMITS ONLY AND SHALL NOT BE
USED FOR ANY OTHER PURPOSE. NOTE:
I. the undersigned. hereby certify IT (5 TIlE RESPONSIBILITY OF TIlE CONTRACfOR TO VERIFY
that the within Plot Plan was ALL HOUSE DIMENSION. CENTER LINES, PATIO/HOUSE
prepared under my supervision OmONS ETC... WITH THE START PACK. THE T. WRIGHT
utilizing information taken from CORPORATION HOLDS NO LIABILITY FOR CONFLICTING INFO.
the Development Plan prepared by
others for this subdivision and,
to the best of my knowledge and
belief. if the finished grades
are constructed as shown, the
surface drainage will be satisfactory
for residential construction.
,.
Andretti Drive
50' RIW
(30' Pvmt.)
M.H. # 717
T.C.: 904.36
Inv.: 897.24
Sanitary Sewer
Certified; September 19. 2006
:\\\\\\lIII/111II/.
#~ D.W:?/~
~ ~..~.,srr~('. ~ ~
::::::J...:.:" N D "."/- ~
_' o. ..-
- -
= 9700013 =
~
M.H. #716
T.e.: 907.68
Inv.: 896.43
o 15', 30'
~~...,.~
GRAPHIC SCALE IN FEET
-
~ STATE OF -' ~
~<: .!(-s
~"11-'~.D'..~~-\,O ~
~/. D SUR'-l~ #'
1'11111111\1\\\\\'\
T. WRIGHT CORP.
LAND SURVEYING SERVICES
360 S, Madison Avenue, Suite 108
Greenwood, Indiana 46142
Phone (317) 885-9900
Fax (317) 885-7076
twrightcorp.com