HomeMy WebLinkAboutES101 - ELECTRICAL SITE PLANJJJJ J J J J STAIR #1 ST1-1 STAIR #2 ST2-1 LEASE SPACE #1 101 LEASE SPACE #2 102 BREEZEWAY 003 WEST LOGGIA 001 UP T2 S1 S1 S1 S1S1S1 S2 S2 S2 S2 S3 S3 S3 S3 S3 S3 S3 S3 S4 S4 S3 S3 S3 S3 S3 S3 S3 S3 S3 S3 S3 1111 2 3 4 5 6 P1A-26,28P1A-27,29P1A-30,327 7 7 CT4 CT2 CT1 8 T12 3 1 P1A - 33 S3 S3 S3 S4 S4 S3 S3 S3 S3 S3 S3 P1A - 19 P1A - 13 S2S2S2 S2 S2 S2 S2 S2 P1A - 6 S2 ARCHITECTCLIENTCONSULTANTPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS19020 PERMIT SETOFFICE ON RANGELINE2023-06-02 ES101ELECTRICAL SITE PLAN3/32" = 1'-0" ELECTRICAL SITE PLAN1 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET E601 FOR LIGHT FIXTURE SCHEDULE. C ALL CONDUIT TO BE 4-INCH SCH 80 PVC UNLESS NOTED OTHERWISE AND BURIED A MINIMUM OF 24-INCHES DEEP. COORDINATE FINAL ROUTING LOCATIONS WITH OTHER TRADES PRIOR TO WORK. REFER TO FEEDER SCHEDULE ON SHEET E901 FOR CONDUIT SIZING. D CONDUIT ROUTING IS DIAGRAMATIC AND MAY SHIFT TO AVOID CONFLICT WITH STRUCTURES AND OTHER TRADES. COORDINATE WITH ALL TRADES ON-SITE BEFORE PERFORMING WORK. E ALL SITE LIGHTING CIRCUITS TO BE CONTROLLED BY DIGITAL CLOCK LOCATED NEAR SOURCE PANEL. SHEET KEYNOTES 1 PROVIDE JUNCTION BOX FOR FUTURE DECORATIVE LIGHTING. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO ROUGH-IN. 2 UTILITY TRANSFORMER PROVIDED BY UTILITY PROVIDER. TRANSFORMER IS TO BE MOUNTED ON PIT PAD. PROVIDE CONCRETE PAD ACCORDING TO UTILITY REQUIREMENTS. 3 SECONDARY CONDUIT AND FEEDERS TO BE FURNISHED AND INSTALLED BY CONTRACTOR. REFER TO SHEET E901 FOR FEEDER INFORMATION. 4 INSTALL 1200A CT CABINET FOR MAIN GEAR PROVIDED BY CONTRACTOR. PROVIDE SECONDARY CONDUIT AND FEEDERS FROM TRANSFORMER TO CT CABINET ACCORDING TO RISER DIAGRAM. PROVIDE FEEDER CONDUCTORS AND CONDUIT FROM CT CABINET TO MAIN GEAR ACCORDING TO RISER DIARAM. LEAVE 5-FEET OF CONDUCTOR FOR EACH PHASE COILED INSIDE CT CABINET. SECONDARY CONDUCTORS FROM TO CT CABINET AND FINAL TERMINATIONS BY CONTRACTOR. 5 PROVIDE SECONDARY CONDUIT AND FEEDERS FROM TRANSFORMER TO FUTURE 1200A CT CABINET FOR 1933 LOUNGE ACCORDING TO RISER DIAGRAM. PROVIDE FEEDER CONDUCTORS AND CONDUIT FROM CT CABINET TO RESTAURANT PANEL ACCORDING TO RISER DIARAM. LEAVE 5-FEET OF CONDUCTOR FOR EACH PHASE COILED INSIDE CT CABINET. SECONDARY CONDUCTORS FROM TO CT CABINET AND FINAL TERMINATIONS BY CONTRACTOR. 6 INSTALL 3000A UTILITY TERMINATION CABINET FOR TENANT SPACE PROVIDED BY CONTRACTOR. PROVIDE SECONDARY CONDUIT AND FEEDERS FROM TRANSFORMER TO TERMINATION CABINET ACCORDING TO RISER DIAGRAM. PROVIDE FEEDER CONDUCTORS AND CONDUIT FROM TERMINATION CABINE TO RESTAURANT PANEL ACCORDING TO RISER DIARAM. LEAVE 5-FEET OF CONDUCTOR FOR EACH PHASE COILED INSIDE TERMINATION CABINET. SECONDARY CONDUCTORS FROM TO CT CABINET AND FINAL TERMINATIONS BY CONTRACTOR. 7 PROVIDE 208V, 1-PH CIRCUIT FOR LEVEL 2 EV CHARGER. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. 8 PROVIDE SECONDARY CONDUIT AND FEEDERS FROM TRANSFORMER TO FIRE PUMP DISCONNECT ACCORDING TO RISER DIAGRAM ON SHEET E901 #DESCRIPTION DATE 1 Addendum - 01 06/08/2023