HomeMy WebLinkAboutA0.01 Project Data and Code SummaryGENERAL PROJECT NOTES
1. DO NOT SCALE DRAWINGS.
2. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN
TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE
BUILDING, AND THE MAJOR ARCHITECTURAL ELEMENTS. AS GRAPHIC
DOCUMENTS THE DRAWINGS DO NOT INDICATE OR DESCRIBE THE WORK
REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE
CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE
INDICATED OR DESCRIBED THE CONTRACTOR SHALL STUDY THE
DRAWINGS AND THEIR GENERAL INFERENCE TO FURNISH THE ITEMS
REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE
WORK.
3. EACH ITEM REPRESENTED IN THE DRAWING SET OR REFERRED TO IN
THE SPECIFICATIONS ARE TO BE PROVIDED BY, COORDINATED BY, AND
INSTALLED BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED
OTHERWISE.
4. DIMENSIONS ARE TAKEN TO FACE OF METAL STUD, FACE OF CONCRETE,
FACE OF MASONRY, FACE OF EXISTING FINISHES, AND COLUMN LINES
UNLESS NOTER OTHERWISE. CLEAR (CLR) DIMENSIONS INDICATE FINISH
SURFACE TO FINISH SURFACE SPANS BETWEEN WALL OR FROM FINISH
SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR OR
CENTERLINE OF PLUMBING FIXTURES.
5. LETTER DESIGNATIONS WITHIN A DIMENSION STRING (SUCH AS "A", "B",
"C" AND SO ON) INDICATE THAT THE DIMENSION IS TO BE FIELD
DETERMINED AND IT IS TO BE EQUAL TO OTHER DIMENSIONS OF THE
SAME LETTER THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT NOT
TO THE SAME DESIGNATION ON OTHER DRAWING SHEETS.
6. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING INDICATES A
DIMENSION THAT IS TO BE EQUAL ONLY RELATIVE TO OTHER EQUAL
CALLOUTS ON THE SAME DIMENSION STRING IN WHICH IT APPEARS.
DIMENSIONS CALLED OUT AS EQUAL ON TWO DIFFERENT DIM ENSION
STRINGS ARE NOT NECESSARILY EQUAL TO EACH OTHER.
7. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING
ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS,
DISCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK.
WRITTEN DOCUMENTATION SHALL BE PROVIDED BY THE CONTRACTOR
REGARDING SUCH ITEMS.
8. FLOORS SHALL SLOPE TO FLOOR DRAINS. SLOPES SHALL COMPLY WITH
ADA ACCESSIBILITY GUIDELINES.
9. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES SHALL EXTEND
FROM THE TOP OF SLAB TIGHT TO THE UNDERSIDE OF THE DECK ABOVE
UNLESS NOTED OTHERWISE.
10. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED W ITHIN THE
DRAWING SET.
11. WALL STUD FRAMING CONTRACTOR SHALL PROVIDE IN-WALL BLOCKING
FOR WALL MOUNTED OWNER PROVIDED AND CONTRACTOR PROVIDED
ITEMS REPRESENTED WITHIN THE DRAWINGS AND SPECIFICATIONS.
12. CONTRACTOR TO PROVIDE BACKER ROD AND SEALANT, OF A TYPE
APPROPRIATE TO EACH CONDITION, BETWEEN MATERIALS BOTH SIMILAR
AND DISSIMILAR THROUGHOUT THE INTERIOR AND EXTERIOR OF THE
BUILDING. (COLORS TO BE SELECTED BY ARCHITECT)
13. CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS AND PROMPTLY
NOTIFY THE OWNER AND THE ARCHITECT OF ANY CONDITIONS THAT ARE
IN CONFLICT WITH THE PROPOSED WORK OR ARE IN VARIANCE WITH
THE CONSTRUCTION DOCUMENTS.
14. CONTRACTOR SHALL PROTECT EXISTING MATERIALS, COMPONENTS,
AND FEATURES DESIGNATED TO REMAIN, BE SALVAGED, AND/OR
REUSED.
15. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND GOVERNING
AUTHORITIES TO ESTABLISH CONSTRUCTION TRAFFIC ACCESS TO THE
SITE AND DESIGNATED CONSTRUCTION ACCESS THROUGHOUT THE
BUILDING.
16. AT COMPLETION OF THE CONTRACT WALLS, CEILINGS, FLOORS, ETC.
ARE TO BE CLEAN OF DEBRIS AND DUST RELATED TO DEMOLITION AND
CONSTRUCTION.
17. EACH EXPOSED AND/OR VISIBLE SURFACE OF THE BUILDING IS TO BE
FINISHED. UNFINISHED EXPOSED MATERIALS ARE NOT ACCEPTABLE.
SITE LOCATION PLAN
14001 River Rd, Carmel, IN 46033 NORTH
BUILDING CODE SUMMARY
GOVERNING CODE:
2014 Indiana Building Code
2014 Indiana Mechanical Code
2014 Indiana Fire Code
2012 Indiana Plumbing Code
2009 Indiana Electrical Code
2010 Indiana Energy Conservation Code
2009 ICC/A117.1 Accessibility Standard
NFPA 13, 2010 Edition
NFPA 72, 2020 Edition
PROJECT SUMMARY:
The project includes a single building with toilet facilities separated by a custodial
room.
CONSTRUCTION TYPE:
Type V, B
OCCUPANCY TYPES:
U, Utility ( Sec. 312.1 )
BUILDING STORIES:
One (1) story ( Table 503 )
BUILDING HEIGHT:
Allowed Height = 40'-0" ( Table 503 )
Actual Height = 14'-2"
BUILDING AREA:
Allowable Area = 5,500 SF ( Table 503 )
Actual Area = 208 SF
OCCUPANCY COUNT:
TOTAL OCCUPANCY COUNT: 3
FIRE RESISTANCE RATINGS:
( Table 601 )
BUILDING STRUCTURE:0-HR
SHAFT ENCLOSURES:0-HR
STAIR ENCLOSURES:0-HR
FLOOR-CEILINGS ASSEMBLIES:0-HR
ROOF-CEILINGS ASSEMBLIES:0-HR
EXTERIOR WALLS:0-HR
INTERIOR NON-LOAD BEARING WALLS:0-HR
INTERIOR NON-LOAD BEARING WALLS:0-HR
SPRINKLERS:
Non-sprinklered
In accepting and utilizing any drawings or other data on any form of electronic
media generated and provided by Browning Day and their consultants, the
person and their organization covenants and agrees that all such drawings and
data are instruments of service of Browning Day and its consultants who shall
retain all common law, statutory law and other rights, including copyrights. The
drawings are scaled but are not intended for use in construction. The use of
electronic files submitted by Browning Day to the downloading party are
provided under the terms and conditions defined in the Construction Documents,
including, but not limited to Section 01 31 00 “Project Management and
Coordination,”Paragraph 1.6.
In accepting and utilizing the files it is further agreed not to use these drawings
and digital data, in whole or in part, for any purpose or project other than the
project which is subject to this Agreement. The downloading party agree to waive
all claims against Browning Day and its consultants resulting in any way from
any unauthorized changes or reuse of the drawings and date for any other project
by anyone other than Browning Day or its consultants.
In addition, the person and their organization agree, to the fullest extent permitted
by law, to indemnify and hold Browning Day and its consultants harmless from
any damage, liability or cost, including reasonable attorneys' fees and cost of
defense, arising from any changes made by anyone other than Browning Day and
its consultants from any reuse of the drawings and data without the prior written
consent of Browning Day.
Under no circumstances shall transfer of the drawings and other instruments of
service on electronic media for use by the downloading party be deemed a sale
by Browning Day. Browning Day makes no warranties, either expressed or
implied, of merchantability and fitness for any particular purpose. The person
making this agreement warrants that they have authority to enter into this
agreement on behalf of their organization and Browning Day can rely on said
authority.
USE OF ELECTRONIC FILES
ABBREVIATIONS
AFF ABOVE FINISH
FLOOR
AL ALUMINUM
B.O. BOTTOM OF
BOT BOTTOM
CIP CAST-IN-PLACE
CJ CONTROL
JOINT
CL CENTERLINE
CLR CLEAR
CMU CONCRETE
MASONRY
UNIT
CONC CONCRETE
CPT CARPET
CT CERAMIC TILE
DIA DIAMETER
DN DOWN
DWG DRAWING
EA EACH
EJ EXPANSION
JOINT
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EQ EQUAL
EWC ELECTRIC
WATER
COOLER
EXIST EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FE FIRE
EXTINGUISHER
FIN FINISH(ED)
SI SQUARE INCH
SIM SIMILAR
SPEC SPECIF-
ICATIONS
SOL SOLID
SURFACE
SS STAINLESS
STEEL
STD STANDARD
STOR STORAGE
STL STEEL
T TREAD(S)
T&G TONGUE AND
GROOVE
T.O. TOP OF
TOC TOP OF CURB
TOW TOP OF WALL
TYP TYPICAL
VCT VINYL
COMPOSITION
TILE
WC WALL-
COVERING
WD WOOD
FLR FLOOR
FT FOOT / FEET
GYP. BD. GYPSUM
BOARD
GL GLASS
HM HOLLOW
METAL
HR HOUR
IHM INSULATED
HOLLOW
METAL
JAN JANITOR
KIT KITCHEN
LAM LAMINATE
LF LINEAR FOOT
MAX MAXIMUM
MIN MINIMUM
MTL METAL
OPP OPPOSITE
P / PT PAINT
POR PORCELAIN
TILE
QT QUARRY TILE
R RISER(S)
RD ROOF DRAIN
RM ROOM
RO ROUGH
OPENING
SF SQUARE FOOT
SHT SHEET
46
1
U
300 1
Custodial
103
57
1
U
300 1
Restroom
102
57
1
U
300 1
Restroom
101
1
1.4
1.6
2
AA.8B
GENERAL LIFE SAFETY NOTES
1. THE MOST RESTRICTIVE FIRE RATING FOR WALLS AND
OTHER COMPONENTS WHICH ARE SUBJECT TO MULTIPLE
VARYING FIRE RATING REQUIREMENTS SHALL BE THE
FIRE RATING FOR THAT ASSEMBLY.
2. FIRE RATED ASSEMBLIES IDENTIFIED WITH A UL-
ASSEMBLY NUMBER SHALL COMPLY WITH THE FULL
CONSTRUCTION AND INSTALLATION REQUIREMENTS
DEFINED BY THAT DESIGNATED UL-ASSEMBLY.
3. SEE BUILDING CODE SUMMARY ON SHEET 0.01.
4. DIMENSIONS SHOWN ON THE LIFE SAFETY PLANS ARE
FOR MEANS-OF-EGRESS / LIFE-SAFETY REFERENCE ONLY
AND ARE NOT FOR CONSTRUCTION. CONTRACTOR IS TO
UTILIZE PRECISE DIMENSIONS PROVIDED ON A1-SERIES
DRAWINGS FOR FLOOR PLAN CONSTRUCTION
DIMENSIONS.
5. MAXIMUM ALLOWABLE TRAVEL DISTANCE FOR ( R ) and
( M ) OCCUPANCIES IS 250'. PER IAC SECTION 1016.
6. MAXIMUM ALLOWABLE TRAVEL DISTANCE FOR ( B )
OCCUPANCIES IS 300'. PER IAC SECTION 1016.
7. DIMENSIONS LABELED AS "TRAVEL" INDICATE THE EXIT
ACCESS DISTANCE ( TRAVEL DISTANCE ) FROM THE
MIDPOINT BETWEEN TWO EXITS TO EITHER OF THE
ASSOCIATED EXITS.
CODED NOTES OF VARYING
TYPES: SEE SCHEDULES ON THIS
SHEET
SYMBOL LEGEND
DENOTES EXIT ACCESS / PATH OF
EGRESS
OCCUPANCY GROUP
NOMINAL SQ. FT.
NUMBER OF EXITS REQUIRED
OCCUPANT LOAD FACTOR
NUMBER OF OCCUPANTS
150E
20 1
ROOM
101
9 See DrawingPer Indiana state Law IC8-1-26,Call Two Full Working DaysBefore You Dig.626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.browningday.com
Project #:Field Survey:Drawn By:Checked By:Scale:Date:7/30/2021SJCA Inc.CARMEL CLAY PARKS & RECREATIONHAMILTON COUNTY, INWHITE RIVER GREENWAYNORTH TRAIL EXTENSIONSHEET XX OF XX SHEETS100% BID SET6/16/2023 9:23:19 AM \\bdmd.local\UEM\UserShare\jfram\Documents\22A056_CarmelParksWR - Architectural (R21)_jframGQNKL.rvtBDay:22056CheckerJune 16, 20230.01Project Data and Code SummaryJEFOverlook
Restrooms
R iver R oadParking
0.01 1/4" = 1'-0"
Floor Plan1Life Safety
NORTH REVISION SCHEDULERev. #Revision DescriptionIssue Date