HomeMy WebLinkAboutA0.01-L ADA ANSI Diagrams3"33" MIN.12" MAX.42" MIN. GB
39" - 41" BOT. VERTICAL GB18" GB2" ( ALLOWS FOR 41" INSTALLATION )4"18" MIN.MIN.1 1/2"FINISH
16" - 18"
24"12" MIN.
36" GB ±
BACK WALL TYPICAL SIDE WALL TYPICAL36" MAX.4"36"±
46" MIN. BLOCKING
28 1/4"11"39 1/4"4"3"4"3"33" MIN.CL
DASHED LINE INDICATES THE MINIMUM REQUIRED
EXTENTS OF BLOCKING AS OUTLINED BELOW:
STUD CONTRACTOR TO PROVIDE IN-WALL BLOCKING
WHICH ALLOWS FOR THE INSTALLATION OF GRAB
BARS IN COMPLIANCE WITH CHAPTER 6 OF THE 2010
ADA AND CHAPTER 6 OF THE 2009 A117.1 ( ANSI ).
BLOCKING IS TO BE INSTALLED 4" MINIMUM PAST THE
FARTHEST CENTERLINE EXTENT OF THE 36" LONG
GRAB BAR MOUNTING PLATE.
IF THE GRAB BAR MOUNTING WALL IS CONCRETE,
CMU OR A TOILET PARTITION IN LIEU OF STUDS
VERIFY PROPER GRAB BAR ANCHORS ARE UTILIZED.
EACH TOILET IDENTIFIED IN THE CONSTRUCTION DOCUMENTS AS AN ACCESSIBLE TOILET SHALL COMPLY WITH THIS DETAIL. A MINIMUM OF ONE TOILET IN
EACH INDIVIDUAL ROOM WHERE TOILETS ARE PROVIDED, WH ETHER OR NOT IDENTIFIED AS SUCH, SHALL BE ACCESSIBLE AND PROVIDE GRAB BARS ( GB )
WITH IN-WALL BLOCKING AS SHOWN IN THE ABOVE DETAILS. VERIFY ADDITIONAL MANUFACTURER REQUIREMENTS FOR GRAB BAR BLOCKING.3"36" MAX.4"42"4"4"3"4"28 1/4"11"39 1/4"23 3/4"8"50" MIN. GB BLOCKINGFINISH FACE OF SIDE WALLFINISH FACE OF BACK WALL41" MAX. GB
39" MIN. GB 2"
4"2"4"
35"10" MIN. BLOCKING
63"HATCHED AREA INDICATES THE ALLOWABLE ZONE
FOR THE DISPENSING POINT OF A TOILET PAPER
DISPENSER. THE DISPENSER ITSELF MUST BE 1 1/2"
MINIMUM CLEAR BELOW THE GRAB BAR ABOVE.
DASHED LINE INDICATES THE MINIMUM REQUIRED
EXTENTS OF BLOCKING AS OUTLINED BELOW:
STUD CONTRACTOR TO PROVIDE IN-WALL BLOCKING
WHICH ALLOWS FOR THE INSTALLATION OF GRAB
BARS IN COMPLIANCE WITH CHAPTER 6 OF THE 2010
ADA AND CHAPTER 6 OF THE 2009 A117.1 ( ANSI ).
BLOCKING IS TO BE INSTALLED 4" MINIMUM PAST THE
FARTHEST CENTERLINE EXTENT OF GRAB BAR
MOUNTING PLATES.
IF THE GRAB BAR MOUNTING WALL IS CONCRETE,
CMU OR A TOILET PARTITION IN LIEU OF STUDS
VERIFY PROPER GRAB BAR ANCHORS ARE UTILIZED.
GENERIC REPRESENTATION OF TOILET SHOWN.
SEE PLUMBING DRAWINGS AND SPECIFICATIONS
FOR FIXTURE TYPE.
GENERIC REPRESENTATION OF TOILET SHOWN.
SEE PLUMBING DRAWINGS AND SPECIFICATIONS
FOR FIXTURE TYPE.
54" MIN. EXTENT
PLEASE NOTE
AS REQUIRED BY GOVERNING CODES HORIZONTAL
GRAB BARS ARE DIMENSIONED TO THE TOP OF
THEIR GRIPPING SURFACE.
THE TOP OF THE BACK WALL GRAB BAR AND THE
TOP OF THE SIDE WALL GRAB BAR ARE TO ALIGN.
PLEASE NOTE
AS REQUIRED BY GOVERNING CODES HORIZONTAL
GRAB BARS ARE DIMENSIONED TO THE TOP OF
THEIR GRIPPING SURFACE.
THE TOP OF THE BACK WALL GRAB BAR AND THE
TOP OF THE SIDE WALL GRAB BAR ARE TO ALIGN.TOP OF SEAT17" - 19"17" - 19"TOP OF SEATFLUSH CONTROLS ARE TO BE ON THE OPEN SIDE OF
THE TOILET OPPOSITE OF THE SIDE WALL.
24" MIN.
42" MAX.
EACH OBSTRUCTED BACK WALL MOUNTED ACCESSORY
SHALL BE MOUNTED TO COMPLY WITH DETAIL.
OBSTRUCTION44" MAX. TO OPERABLE LEVER OR SWITCHGENERIC ACCESSORY
SHOWN. SEE PLANS,
SCHEDULES AND
SPECIFICATIONS
OBSTRUCTIONEACH SIDE WALL MOUNTED ACCESSORY SHALL BE MOUNTED
TO COMPLY WITH DETAIL.
UNOBSTRUCTED WALL
MOUNTED ACCESSORIES
ARE TO BE MOUNTED WITH
THEIR OPERABLE LEVERS /
SWITCHES AT 48" MAX.
15" CLR FORWARD
24" CLR PARALLEL
15" CLR FORWARD
24" CLR PARALLEL
CLEAR FLOOR SPACE
30" FORWARD OR 48" PARALLEL APPROACH
X = OVERLAP
Z = OPERABLE MOUNTING HEIGHTOBSTRUCTIONCL
X= THEN Z=
.5" 48"
2" 46"
5" 42"
6" 40"
9" 36"
11" 34"
OBSTRUCTED WALL
MOUNTED ACCESSORIES
ARE TO BE MOUNTED
PER THE TABLE BELOW.
OBSTRUCTION FINISH FACE OF SIDE WALL48" MAX. TO TOP OF HOOK4" MAX.
HOOKS MOUNTED WITHIN SINGLE OCCUPANT RESTROOMS,
ACCESSIBLE TOILET COMPARTMENTS AND AMBULATORY
TOILET COMPARTMENTS SHALL COMPLY WITH THIS DETAIL
HOOKS NOT REQUIRED
TO BE MOUNTED AT AN
ACCESSIBLE HEIGHT ARE
TO BE MOUNTED AT 68"
UNLESS NOTED
OTHERWISE. VERIFY
MOUNTING HEIGHTS OF
UNSPECIFIED HOOKS
WITH ARCHITECT /
INTERIOR DESIGNER
PRIOR TO INSTALLATION.See DrawingPer Indiana state Law IC8-1-26,Call Two Full Working DaysBefore You Dig.626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.browningday.com
Project #:Field Survey:Drawn By:Checked By:Scale:Date:7/30/2021SJCA Inc.CARMEL CLAY PARKS & RECREATIONHAMILTON COUNTY, INWHITE RIVER GREENWAYNORTH TRAIL EXTENSIONSHEET XX OF XX SHEETS100% BID SET6/16/2023 9:23:20 AM\\bdmd.local\UEM\UserShare\jfram\Documents\22A056_CarmelParksWR - Architectural (R21)_jframGQNKL.rvtBDay:22056CheckerJune 16, 2023A0.01-LADA - ANSI DiagramsJEFA0.01-L 3/4" = 1'-0"
Accessibility Detail5( ADA-ANSI ) Accessible Toilet, Grab Bar and Blocking Requirements
A0.01-L 3/4" = 1'-0"
Accessibility Detail4( ADA-ANSI ) Back Wall Mounted Accessories
A0.01-L 3/4" = 1'-0"
Accessibility Detail3( ADA-ANSI ) Side Wall Mounted Accessories
A0.01-L 3/4" = 1'-0"
Accessibility Detail2( ADA-ANSI ) Wall and Door Hooks REVISION SCHEDULERev. #Revision DescriptionIssue Date