HomeMy WebLinkAboutC801 UTILITY DETAILSCONCRETE CRADLE DETAIL
NOTE: TO BE USED WHEN CLEAR DISTANCE (FROM EXTERIOR PIPE DIAMETER TO EXTERIOR PIPE
DIAMETER) BETWEEN SANITARY SEWER PIPING (MAINS, LATERALS, FORCE MAINS, ETC.) AND ALL OTHER
PIPES IS 18" OR LESS, PER INSPECTOR'S DIRECTION, OR WHERE NOTED ON THE DRAWINGS. A MINIMUM
CLEAR DISTANCE OF 3" MUST BE PROVIDED TO MAINTAIN STRUCTURAL INTEGRITY OF THE CONCRETE.
CRADLE SHALL BEAR ON
UNDISTURBED EARTH
PERSPECTIVE VIEW
EARTH CUT AWAY
C801UTILITY DETAILSw190175-C801 util detBOTTOM OF TRENCH
(NO SCALE)
3500 PSI CONCRETE
(NO SCALE)
TYPICAL VALVE BOX INSTALLATION
SIMILAR INSTALLATION FOR CURB
BOX OR SERVICE LINE
COMPACTED BACKFILL
TO NATURAL GROUND
ADJUSTABLE
CAST IRON VALVE BOX
EAST JORDON NO. 6860
5.25" SHAFT
42" MIN."POSI-CAP"
VALVE COVER RUSSELL L . W EBST
E
R
I
I
PR
O
FESSION A L E N GINEERREG IS T ER
E
DIND I A N A
PE11900318
STATE OF
NO.REVISIONS AND ISSUESPart of the NW/4 of Section 26, Township 18 North, Range 3 East, Clay Township, Hamilton County, IndianaW19.0175PREPARED FOR:13285 ILLINOIS ST. CARMEL, IN 46032PROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:RLWDESIGNED BY:DWG NAME:PROJECT NO.:W19.0175DATEBY11.13.2019SSRDATE:RLWSAAMRAJYA, LLCPLANS SUBMITTED FOR REVIEW05.15.2019RLWENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMRUSSELL L. WEBSTER II, PE No. 11900318PLANS REVISED FOR TAC COMMENTS05.15.2019RLWPLANS REVISED FOR TAC COMMENTS11.13.2019RLWAPPROVAL PENDINGNOT F
OR C
O
NSTR
UCTI
O
N