Verizon Indianapolis Permit and Construction Set_4-21-2023.pdf
Prepared for RENOVATION OF Issued information Verizon Indianapolis VERIZON 250 E. 96th Street, 3rd Floor Indianapolis, Indiana 4-21-2023 PERMIT & CONSTRUCTION Hellmuth, Obata & Kassabaum, Inc. FF AS P EPS MPS OS S F F F GENERAL PROJECT DESCRIPTION PROJECT SCOPE IS TO RENOVATE THE SOUTH HALF OF THE THIRD FLOOR OF AN EXISTING FIVE STORY BUILDING TO SERVE AS A DOWNSIZED SUITE FOR AN EXISTING BUSINESS-OCCUPANCY TENANT. SCOPE OF WORK INCLUDES SELECTIVE DEMOLITION OF EXISTING INTERIOR FIT-OUT TO COORDINATE WITH NEW PLAN. NEW INTERIOR CONSTRUCTION TO INCLUDE NEW LARGE CONFERENCE ROOM, AN ACCESSORY MEETING ROOM, AND A NEW WELLNESS ROOM. PROJECT SCOPE IS APPROXIMATELY 9,244 SQUARE FEET. SCOPE OF WORK DOES NOT ALTER EXISTING BUILDING EXTERIOR SKIN, EXISTING BUILDING HEIGHT, EXISTING BUILDING AREA, EXISTING BUILDING EXIT ACCESS / EXIT STAIRS / EXIT DISCHARGE CONFIGURATION OR CAPACITY. PROJECT DOES NOT CHANGE OCCUPANCY CLASSIFICATION AND USE GROUP. LOCATION MAP NOT TO SCALE 250 E. 96th Street, 3rd Floor, Indianapollis, Inidiana VIEW TITLE VIEW NUMBER VIEW TITLE GRAPHIC SYMBOLS CALLED NORTH TRUE NORTH SHEET REFERENCE SYMBOL VIEW NUMBER SHEET NUMBER CATEGORY DISCIPLINE ASSEMBLY SECTION REFERENCES SCOPE OF NEW WORK EXISTING WORK COLUMN CENTER LINE COLUMN GRID LABEL REFER TO THIS SHEET IDENTIFICATION ELEVATION DETAIL REFERENCES REFER TO THIS SHEET IDENTIFICATION MATCHLINE SEE: A/A201 ROOM NAME / NUMBER / FINISH SYMBOL ROOM NAME ROOM IDENTIFICATION ROOM NUMBER PARTITION TYPE, DOOR, AND MISC SYMBOLS PARTITION TYPE TAG KEY NOTE REVISION CLOUD INDICATES +/-FROM REF ELEVATION DIMENSION POINT ELEVATION DATUM ELEVATION SYMBOLS 1 TITLE 1/8" = 1'-0" VIEW SCALE N 1 A201 11 A301 2 A941 MATCHLINE SEE: A/A202 10 101 EL +12" DP FL EL 0' -0"45.00°1 7/32" 5' -0"23/32" R 3' -0"A 1 1.1 DIMENSION LINES 1A3A 101A 3 A701 (SYSTEM No. 1) DOOR NUMBER ANNOTATION SYMBOLS A601 2 1 4 3 INDICATES FINISHED SURFACES SHALL ALIGN DETAIL CALLOUT DETAIL SECTION REVISION NUMBER REFER TO THIS SHEET IDENTIFICATION ELEVATION REFERENCES P11 FINISH TAG REVISED AREA 1 A501 CENTERLINE ROOM FINISH GROUPO1.3 3 / A601 101A (SYSTEM No. 2) DOOR NUMBER ALIGN A3 10 HARDWARE GROUP OPENING CODE INDICATES FLUSH FLOOR BOX INDICATES TYPE AS OUTLINED BELOW "(F)" WHEN PRESENT INDICATES FLOOR BOX IS SERVING FURNITURE AND IS TO BE COORDINATED WITH SPECIFIC FURNITURE REQUIREMENTS FOR EXACT PLACEMENT. TYPE A: TYPE B: TYPE C: TYPE D:AV FB AV (F)ADUPLEX DEDICATED DUPLEX POWER / DATA RACEWAY TELE / DATA ROOM SCHEDULER SECURITY CARD READER D POWER AND DATA PLAN LEGEND WALL MOUNTED DEVICES INDICATES RECESSED COLLECTOR WALL BOX FOR AV INSTALLATION INDICATES TYPE AS OUTLINED BELOW TYPE A: TYPE B: TYPE C:AV AWB RR CR AV RECESSED WALL BOX FLUSH BOX RECESSED AT FLOOR FLOOR PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION, PARTITION TYPE AS INDICATED ON PLAN EXISTING ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS SCOPE OF WORK NEW RECESSED FIRE EXTINGUISHER CABINET -STEEL. PROVIDE ABC MULTI-PURPOSE DRY CHEMICAL PORTABLE FIRE EXTINGUISHER, 10LB, UON NEW CASEWORK/ MILLWORK, COORDINATE ALSO WITH POWER AND DATA PLAN NEW GLAZED OPENING WITH ALUM OR HM FRAME AS INDICATED NEW DOOR AND FRAME OPENING FEC 2 HR FIRE RATED CONSTRUCTION (Fire Rating = 2) 1 HR FIRE RATED CONSTRUCTION (Fire Rating = 1) 1 HR RATED GLAZED FIRE BARRIER (Fire Rating = 1-GL) 2 HR RATED GLAZED FIRE BARRIER (Fire Rating = 2-GL) 1 HR RATED GLAZED FIRE & SMOKE BARRIER (Fire Rating = 1S-GL) S S S S S 2' x 2' GRID AND TILE SYSTEM GYPSUM BOARD CEILING OPEN TO STRUCTURE ABOVE WITH PAINTED FINISH SPECIALTY CEILING [DOCUMENTER: DEFINE THIS] MATERIALS FINISHED CEILING HEIGHT, AFF8' -6" ANNOTATIONS SECURITY SECURITY CAMERA REFLECTED CEILING PLAN LEGEND LIGHT FIXTURES RECESSED DOWNLIGHT 4' RECESSED LINEAR WALLWASH 4' RECESSED LINEAR 2' x 2' RECESSED 2' x 4' RECESSED RECESSED WALL WASH DOWNLIGHT PENDANT WALL SCONCE PENDANT MOUNTED LINEAR UNDER CABINET UPLIGHT STRIP SEMI RECESS WALLWASH SURFACE MOUNTED STRIP LIGHT POWER & DATA FURNITURE FEED, POWER POLE AUDIO SPEAKER PROJECTOR PROJECTION SCREEN - ELECTRONIC PROJECTION SCREEN - MANUAL OCCUPANCY SENSOR LIFE SAFETY EXIT SIGN ARROW INDICATES PATH OF TRAVEL SMOKE DETECTOR LIFE SAFETY SPEAKER STROBE LIFE SAFETY SPEAKER LIFE SAFETY STROBE SCHEMATIC SPRINKLER HEAD LOCATION CLOSED-CIRCUIT TV A A/C AIR CONDITIONING AD AREA DRAIN ADA AMERICANS WITH DISABILITIES ACT ADAAG ADA ACCESSIBILITY GUIDELINES ADDL ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATE(LY) ARCH ARCHITECT / ARCHITECTURE AV AUDIO VISUAL B B/BOTTOM OF (see other word) BLDG BUILDING BSMT BASEMENT C CAB CABINET CAT CATEGORY CB CATCH BASIN CI CAST IRON CIP CAST IN PLACE CJ CONTROL JOINT / CONSTRUCTION JOINT CL CENTER LINE CLG CEILING CLR CLEAR CM CENTIMETER CMB CEMENT BOARD CMU CONCRETE MASONRY UNIT CO CLEANOUT COL COLUMN CONC CONCRETE CONT CONTINUOUS COORD COORDINATE CORR CORRIDOR CS CONCRETE SEALER CTR CENTER D DB DECIBEL DEG DEGREE DEMO DEMOLITION DEPT DEPARTMENT DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIFF DIFFUSER DIM DIMENSION DL DEAD LOAD DN DOWN DP DESIGN / DIMENSION POINT DR DOOR DRN DRAIN DW DISHWASHER DWG DRAWING E EA EACH EIFS EXTERIOR INSULATION AND FINISH SYSTEM EFS EXTERIOR FINISH SYSTEM EL ELEVATION ELEC ELECTRICAL EMERG EMERGENCY ENCL ENCLOSURE EP ELECTRICAL PANELBOARD EQ EQUAL EQUIP EQUIPMENT EWC ELECTRICAL WATER COOLER EXH EXHAUST EXIST EXISTING EXP EXPANSION EXT EXTERIOR F FA FIRE ALARM FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FEQ FOOD EQUIPMENT FF&E FURNITURE, FIXTURES & EQUIPMENT FF FLOOR FINISH FHC FIRE HOSE CABINET FIN FINISH FL FLOOR FLUOR FLUORESCENT F/FACE OF (see next word) FO FINISHED OPENING FRTW FIRE RETARDANT TREATED WOOD FS FIRE STOPPING FT FEET / FOOT FTG FOOTING FURN FURNITURE G GA GAUGE / GAGE GALV GALVANIZED GC GENERAL CONTRACTOR / GENERAL CONTRACT GFRC GLASS FIBER REINFORCED CONCRETE GFRG GLASS FIBER REINFORCED GYPSUM GFRP GLASS FIBER REINFORCED PLASTIC GR GRADE GWB GYPSUM WALLBOARD H HB HOSE BIB HC HANDICAPPED HM HOLLOW METAL HO HOLD-OPEN HORIZ HORIZONTAL HP HIGH POINT HRC HOSE REEL CABINET HR HOUR HSS HOLLOW STRUCTURAL SECTION HT HEIGHT HVAC HEATING, VENTILATING, AIR CONDITIONING HW HOT WATER I IBC INTERNATIONAL BUILDING CODE ICB INTEGRAL COVE BASE ICC INTERNATIONAL CODE COUNCIL ID INSIDE DIAMETER / DIMENSION IN INCH INFO INFORMATION INT INTERIOR INV INVERT J JC JANITOR'S CLOSET JST JOIST JT JOINT K K KIPI (1000 LB) KG KILOGRAM KIT KITCHEN L LAB LABORATORY LAT LATERAL LAV LAVATORY LB POUND LF LINEAR FOOT LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LOW POINT LT LIGHT LV LOW VOLTAGE STANDARD ABBREVIATIONS M M METER MAINT MAINTENANCE MAX MAXIMUM MCC MOTOR CONTROL CENTER MDF MEDIUM DENSITY FIBERBOARD MDO MEDIUM DENSITY OVERLAY MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, PLUMBING MER MECHANICAL EQUIPMENT ROOM MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINIMUM MISC MISCELLANEOUS MM MILLIMETER MTD MOUNTED MTL METAL N N NEWTON N/A NOT APPLICABLE NC NOISE CRITERIA NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NPS NOMINAL PIPE SIZE NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE O OA OUTSIDE AIR OC ON CENTER OCEW ON CENTER EACH WAY OD OUTSIDE DIAMETER / DIMENSION OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED OH OVERHEAD OPNG OPENING OPP OPPOSITE OPP HD OPPOSITE HAND OXY OXYGEN P PAF POWER ACTUATED FASTENER PBD PARTICLE BOARD PD PERIMETER DRAIN PERF PERFORATED PL PLATE PLAM PLASTIC LAMINATE P-LAM PLASTIC LAMINATE PLBG PLUMBING PLF POUNDS PER LINEAR FOOT PR PAIR PREFAB PREFABRICATED PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PTD PAINTED PTN PARTITION Q QTY QUANTITY R R RADIUS RA RETURN AIR RCP REFLECTED CEILING PLAN RD ROOF DRAIN RECEPT RECEPTACLE RECEPT RECEPTION REF REFERENCE REFR REFRIGERATOR REINF REINFORCED / REINFORCING REQ REQUIRE / REQUIRED REV REVISION / REVISED RM ROOM RO ROUGH OPENING S SA SUPPLY AIR SAFB SOUND ATTENUATING FIRE BLANKET / BATT SAN SANITARY SCHED SCHEDULE SD STORM DRAIN SECT SECTION SF SQUARE FEET / FOOT SHR SHOWER SHT SHEET SIM SIMILAR SM SQUARE METER SMS SHEET METAL SCREW SP STANDPIPE SPEC SPECIFICATION SPKR SPEAKER SPR SPRINKLER SQ SQUARE SST STAINLESS STEEL STD STANDARD STL STEEL STMS SELF-TAP SHEET METAL SCREW STRL STRUCTURAL SUSP SUSPENDED SYMM SYMMETRICAL T T/TOP OF (see other word) T&G TONGUE AND GROOVE TEL TELEPHONE or TELECOM TEMP TEMPERATURE TEMP TEMPORARY TGB TOGGLE BOLT THK THICK TP TOILET PARTITION TV TELEVISION TYP TYPICAL U UL UNDERWRITERS LABORATORY UNO UNLESS NOTED OTHERWISE UON UNLESS OTHERWISE NOTED V VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD W W/WITH W/O WITHOUT WC WATERCLOSET WDS WOOD SCREW WP WORK POINT WT WEIGHT WWR WELDED WIRE REINFORCING NSheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:31 PMSYMBOLS AND ANNOTATIONS LEGENDS AND STANDARD ABBREVIATIONS G001 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 Sheet Number SHEET NAME PERMIT & CONSTRUCTION 4-21-202301 GENERAL G000 COVER SHEET X G001 SYMBOLS AND ANNOTATIONS LEGENDS AND STANDARD ABBREVIATIONS X G002 GENERAL NOTES X G010 TYPICAL DEVICE MOUNTING DIAGRAMS X G020 ADAAG ACCESSIBILITY COMPONENTS - GENERAL X G101 LIFE SAFETY PLAN AND CODE OUTLINE X 02 ARCHITECTURE A101 DEMOLITION PLAN AND CONSTRUCTION PLAN- LEVEL 3 X A201 DEMO REFLECTED CEILING PLAN AND REFLECTED CEILING PLAN - LEVEL 3 X A301 POWER & DATA PLAN AND FINISH PLAN - LEVEL 3 X A501 SIGNAGE PLAN - LEVEL 3 X A610 PARTITION TYPES LEGEND AND DETAILS X A611 PARTITION DETAILS X A612 PARTITION FRAMING DETAILS X A620 DOOR, FRAME, HARDWARE LEGENDS, AND DETAILS X A801 ELEVATIONS AND DETAILS X 03 MECHANICAL M-1 LEVEL 3 FLOOR PLAN - MECHANICAL, DEMOLITION X M-2 LEVEL 3 FLOOR PLAN - MECHANICAL, NEW X 04 FIRE PROTECTION FP-1 LEVEL 3 FLOOR PLAN - FIRE PROTECTION SYSTEM X 05 ELECTRICAL E-1 LEVEL 3 FLOOR PLAN - ELECTRICAL LIGHTING, DEMOLITION X E-2 LEVEL 3 FLOOR PLAN -ELECTRICAL POWER, DEMOLITION X E-3 LEVEL 3 FLOOR PLAN - ELECTRICAL LIGHTING, NEW X E-4 LEVEL 3 FLOOR PLAN - ELECTRICAL POWER, NEW X E-5 ELECTRICAL SYMBOLS LEGEND AND DETAILS X 06 AUDIO/VISUAL AV-001 AUDIO VISUAL INSTRUCTIONS/NOTES,SYMBOLS AND DRAWING LIST X AV-103 AUDIO VISUAL LEVEL 3 FLOOR PLAN X AV-203 AUDIO VISUAL CEILING PLAN LEVEL 3 X AV-301 ROOM RESERVATION INTSALLATION DETAIL FOR NAVIGATOR SOLUTION X AV-401 AUDIO VISUAL ELEVATIONS ROOM 321 -SMALL CONFERENCE ROOM X AV-402 AUDIO VISUAL ELEVATIONS ROOM 322 -SMALL CONFERENCE ROOM X AV-403 AUDIO VISUAL ELEVATIONS ROOM 122 -MEDIUM CONFERENCE ROOM X AV-404 AUDIO VISUAL ELEVATIONS ROOM 305 -MEDIUM CONFERENCE ROOM X AV-405 AUDIO VISUAL ELEVATIONS ROOM 320 -EXTRA LARGE CONFERENCE ROOM X AV-501 AUDIO VISUAL SYSTEM DIAGRAM – SMALL CONFERENCE ROOM - 321 X AV-502 AUDIO VISUAL SYSTEM DIAGRAM – SMALL CONFERENCE ROOM - 322 X AV-503 AUDIO VISUAL SYSTEM DIAGRAM – MEDIUM CONFERENCE ROOM - 122 X AV-504 AUDIO VISUAL SYSTEM DIAGRAM – MEDIUM CONFERENCE ROOM - 305 X AV-505 AUDIO VISUAL SYSTEM DIAGRAM – EXTRA LARGE CONFERENCE ROOM - 320 X 07 LOW VOLTAGE TC-001 COMMUNICATIONS NOTES,SYMBOLS AND DRAWING LIST X TC-103 COMMUNICATIONS LEVEL 3 FLOOR PLAN X TC-103D COMMUNICATIONS LEVEL 3 DEMO FLOOR PLAN X TC-203 COMMUNICATIONS LEVEL 3 REFLECTED CEILING PLAN X TC-203D COMMUNICATIONS LEVEL 3 REFLECTED CEILING DEMO PLAN X TC-301 COMMUNICATIONS INSTALLATION DETAIL X TC-401 COMMUNICATIONS LEVEL 3 – IDF ROOM PART PLANS AND ELEVATIONS X 08 SECURITY SC-001 SECURITY NOTES,SYMBOLS AND DRAWING LIST X SC-103 SECURITY LEVEL 3 FLOOR PLAN X SC-103D SECURITY LEVEL 3 DEMO FLOOR PLAN X SC-203 SECURITY LEVEL 3 REFLECTED CEILING PLAN X SC-203D SECURITY LEVEL 3 REFLECTED CEILING DEMO PLAN X SC-301 SECURITY TYPICAL DOOR ELEVATIONS X SC-302 SECURITY TYPICAL INSTALLATION DETAILS X DRAWING INDEX 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 1. CONTRACTOR TO OBTAIN DEMOLITION PERMITS. 2. PARTITIONS INDICATED FOR DEMOLITION ARE TO COORDINATE WITH FINAL SPACE PLAN. PHASING OF FINAL PARTITION DEMOLITION TO BE DETERMINED BY CONTRACTOR TO ACCOMMODATE BUILDING USER SAFETY AND SECURITY. COORDINATE WITH TENANT REPRESENTATIVE FOR ADDITIONAL REQUIREMENTS AND RESTRICTIONS. VERIFY THAT CONSTRUCTION INDICATED FOR REMOVAL IS NOT LOAD BEARING. 3. IN ADDITION TO ILLUSTRATED PARTITIONS, REMOVE EXISTING RELATED MILLWORK, PLASTIC LAMINATE CABINETRY, FLOOR FINISHES, DOORS, FRAMES, INTERIOR GLASS, CEILINGS, LIGHTING AND RELATED ELEMENTS THROUGHOUT. ASSEMBLIES TO BE REMOVED COMPLETE, INCLUDING PREVIOUSLY CONCEALED FRAMING AND ANCHORS. AT PARTITIONS AND COLUMN ENCLOSURES SHOWN TO REMAIN, REMOVE WALL COVERINGS AND WALL BASE COMPLETE IN PREPARATION FOR NEW WALL FINISH AND WALL BASE. 4. AT AREAS OF FLOOR FINISH REMOVAL, ADDITIONALLY PREPARE SLAB SMOOTH AND FLUSH FOR PROPER INSTALLATION OF NEW FINISH FLOOR MATERIALS. REMOVE ALL EXISTING IRREGULAR MATERIALS SUCH AS FASTENERS, OUTLET CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET, CARPET PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, AND SIMILAR ITEMS. PREPARATION TO INCLUDE SELECTIVE FLOOR GRINDING, BEAD BLASTING, AND FLASH PATCHING AS REQUIRED TO YIELD A SMOOTH AND LEVEL SUB-SURFACE. 5. WHERE DEMOLITION EXPOSES OR RESULTS IN ABANDONED FLOOR SLAB PENETRATIONS, PROVIDE STEEL PLATE BELOW FLOOR SLAB TO MATCH GAUGE AND CONTOUR OF METAL DECK. PLATE TO OVERLAP EXISTING UNDERSIDE BY MIN 12" IN ALL DIRECTIONS. INFILL HOLE IWTH CONCRETE FLUSH WITH TOP OF EXISTING SLAB TO MAINTAIN EXISTING FIRE RATING OF FLOOR ASSEMBLY. 6. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN WRITING WITH THE ARCHITECT BEFORE PROCEEDING. 7. AT COMPLETION OF DEMOLITION WORK, CONSTRUCTION AREA(S) ARE TO BE LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL TO BE FULLY REMOVED. 8. WHERE ELECTRICAL DEVICES, DATA DEVICES, LIGHT FIXTURES, OR SIMILAR ITEMS EXIST AT PARTITIONS OR CEILINGS TO BE REMOVED, REMOVE CONDUITS, WIRES, AND CABLES COMPLETE BACK TO THE SOURCE. 9. WHERE ELECTRICAL DEVICES, DATA DEVICES, LIGHT FIXTURES, OR SIMILAR ITEMS ARE TO BE REMOVED AT PARTITIONS OR CEILINGS TO REMAIN FOR REUSE, REMOVE JUNCTION BOXES, CONDUITS, WIRES AND CABLES COMPLETE BACK TO THE SOURCE. HOLES AT PARTITIONS AND CEILINGS TO BE PATCHED SMOOTH TO MATCH ADJACENT SURFACES IN PREPARATION FOR NEW FINISHES. 10. CONTRACTOR TO BE RESPONSIBLE FOR CLEANING, PATCHING AND/OR REPAIRING ANY DAMAGE CAUSED BY SUBCONTRACTORS TO EXISTING CONSTRUCTION IN BASE BUILDING ELEVATOR LOBBY, PUBLIC CORRIDORS, TOILET ROOMS OR ADJACENT TENANT SPACES. REFINISH TO MATCH EXISTING ADJACENT FINISH. 11. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING, TO BE DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, IF NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR TO BE COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN ITS INTENDED PURPOSE. 12. REMOVE TO SOURCE ALL PIPES, VENTS, APPLIANCE CONNECTIONS, AND DRAINS NOT TO BE REUSED. 13. PROTECT BASE BUILDING HVAC SYSTEM FROM DUST DURING ALL PHASES. SELECTIVELY REMOVE EXISTING DUCTWORK TO COORDINATE WITH NEW PLAN. 14. EXISTING SPRINKLER SYSTEM TO REMAIN FOR MODIFICATION AT FINAL PLAN. PROTECT DURING ALL PHASES. COORDINATE WITH ENGINEERING DOCUMENTATION AND BASE BUILDING REPRESENTATIVE FOR RESTRICTIONS. 15. PROTECT EXISTING WINDOW TREATMENTS FOR REUSE AT FINAL PLAN. PROVIDE BAGGED PROTECTIONS. 16. DO NOT CUT OR REMOVE STRUCTURAL STEEL, STRUCTURAL CONCRETE, OR LOAD BEARING UNIT MASONRY WITHOUT WRITTEN APPROVAL OF BASE BUILDING REPRESENTATIVE. 17. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE AFFECTED AREAS AT NO COST TO OWNER OR TENANT. 18. ENGINEER AND PROVIDE REQUIRED TEMPORARY SHORING AND SUPPORT TO COORDINATE WITH DEMOLITION. GENERAL DEMOLITION PLAN NOTES 1. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS. 2. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, CLEARANCE, AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND COMPONENTS. DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE DRAWINGS. 3. THE CONTRACTOR SHALL PROVIDE COMPLETE PROJECT SYSTEMS AND COMPONENTS AND COMPLY WITH ALL REQUIREMENTS INDICATED ON THE PROJECT DOCUMENTS. NOTHING IN THE DRAWINGS OR RELATED DOCUMENTS IS TO BE CONSTRUED AS REQUIRING OR PERMITTING WORK THAT IS CONTRARY TO APPLICABLE CODES. 4. WORK WITHIN THE AREA BOUNDARIES INDICATED IN THE PROJECT DOCUMENTS TO COMPLY WITH ALL APPLICABLE BUILDING CODE, REGULATION, AND ORDINANCE REQUIREMENTS. RESTRICT WORK, STAFF, MATERIAL, AND DEBRIS TO THE CONTRACT PREMISES AND AS AUTHORIZED BY BASE BUILDING REPRESENTATIVE. OCCUPANTS ADJACENT TO THE PROJECT BOUNDARIES TO CONTINUE UNINTERRUPTED OCCUPANCY AND ON-GOING BUSINESS ACTIVITIES DURING CONSTRUCTION OF THE PROJECT. MAINTAIN CONTINUOUS SERVICE TO ALL UTILITIES AND FEEDS SERVING ADJACENT OCCUPIED SPACES. 5. PLAN AND PROVIDE FOR TEMPORARY PARTITIONS, GUARDRAILS, HANDRAILS, AND ALL OTHER SAFEGUARDS FOR THE PROTECTION OF EXISTING BASE BUILDING EMPLOYEES AND BUILDING USERS FROM CONSTRUCTION HAZARDS DURING ALL PHASES OF DEMOLITION OR CONSTRUCTION. SEAL AREA WITH PLASTICS TO CONTAIN THE SPREAD OF DUST. MATERIALS, DEBRIS, AND RUBBLE FROM DEMOLITION TO BE PROMPTLY REMOVED FROM PREMISES. TEMPORARY PARTITIONS AND DOORS SHALL BE INSTALLED AS REQUIRED TO MAINTAIN A SECURE WORKPLACE. 6. PROTECT EXISTING PARTITIONS, FLOOR FINISHES, DOORS, ELEVATORS, PLUMBING FIXTURES, AND CEILING FINISHES BEYOND CONTRACT AREA FROM DAMAGE DURING ALL PHASES. 7. MAINTAIN ACCESS TO REQUIRED MEANS OF EGRESS BY TENANT EMPLOYEES AND BUILDING VISITORS DURING ALL PHASES. MAINTAIN IN OPERATING CONDITION EXISTING EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES AND ALARMS PER CODE. COORDINATE WITH BASE BUILDING REPRESENTATIVE. 8. PROVIDE FOR TEMPORARY FIRE EXTINGUISHERS DURING ALL PHASES. PROVIDE TEMPORARY LIGHTING AND POWER DURING ALL PHASES. 9. VERIFY FIELD CONDITIONS AND COORDINATE WITH PROJECT DOCUMENTS PRIOR TO PROCEEDING WITH THE WORK. INFORMATION SHOWN ON THESE DOCUMENTS IS BASED ON INFORMATION PROVIDED TO OR OBTAINED BY HOK INDICATING EXISTING CONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY FROM THOSE INDICATED ON THE DRAWINGS. SHOULD ACTUAL CONDITIONS DIFFER SUBSTANTIALLY FROM THOSE INDICATED ON THE DRAWINGS OR FROM THOSE ORDINARILY ENCOUNTERED IN RENOVATION OR FIT-OUT WORK OF THIS TYPE, PROMPTLY NOTIFY ARCHITECT AND OWNER BEFORE ANY OF THESE CONDITIONS ARE DISTURBED. 10. PERFORM THE WORK AT THE PROJECT SITE DURING NORMAL BUSINESS HOURS, UNLESS OTHERWISE NOTED. COMPLY WITH BASE BUILDING CONSTRUCTION RULES, RESTRICTIONS, REGULATIONS AND HOURS OF OPERATION. COORDINATE FREIGHT ELEVATOR SCHEDULING AND RESTRICTIONS WITH BASE BUILDING REPRESENTATIVE. 11. COORDINATE THE WORK WITH EQUIPMENT, FURNISHINGS AND SYSTEMS PROVIDED BY THE OWNER. 12. UTILIZE REBAR DETECTOR / X-RAY TECHNOLOGY TO LOCATE EXISTING POST-TENSION TENDONS AND REBARS WITHIN CONCRETE SLABS, COLUMNS, AND CONSTRUCTION. INSTALL ANCHORS AT MINIMUM 2 INCHES AWAY FROM EXISTING CONCEALED OR EXPOSED METAL ELEMENTS. 13. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM SHALL BE PROVIDED FOR EACH OCCURRENCE OF THE CONDITION NOTED. EVERY MATCHING OCCURANCE MAY NOT BE LABELED. 14. "SIMILAR" OR "SIM" INDICATES COMPLETE SYSTEM AND COMPONENTS SHALL BE PROVIDED COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. CONDITION MAY BE OPPOSITE-HAND, REVERSE DIRECTION, OR MAY VARY DIMENSIONALLY. 15. "AS REQUIRED" INDICATES COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS SHALL BE PROVIDED. 16. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE AND PLUMB RELATION TO ADJACENT MATERIALS. 17. "UNO" OR "UON" INDICATES "UNLESS NOTED OTHERWISE." 18. "AFF" INDICATES "ABOVE FINISHED FLOOR FACE." 19. DIMENSIONS ARE INDICATED TO THE FINISH FACE OF FULL PARTITION ASSEMBLY (INCLUDING APPLIED FINISH DEPTHS WHEN PRESENT), CENTERLINE OF PARTITION, CENTERLINE OF BASE BUILDING WINDOW MULLION, NOSE OF MILLWORK COUNTERTOP, EDGE OF FINISHED DOOR OPENING, OR FACE OF EXISTING BASE BUILDING ELEMENT SUCH AS ELEVATOR CORE OR COLUMN SURROUND. 20. ALIGNMENT OF PARTITIONS AND FINISHES TO BE STRAIGHT, TRUE, AND PLUMB. 21. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE COORDINATED AND MAINTAINED. 22. VERTICAL DIMENSIONS ARE INDICATED FROM FACE OF FINISH FLOOR TO FACE OF FINISHED MATERIAL, UNO. 23. CEILING HEIGHTS ARE INDICATED FROM THE FACE OF FINISHED FLOOR TO THE FACE OF SUSPENDED ACOUSTIC CEILING ASSEMBLY OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNO. 24. EACH DRAWING SHEET IS IDENTIFIED BY THE SHEET NUMBER IN THE LOWER RIGHT HAND CORNER OF THE DRAWING TITLE BLOCK. THE SHEET TITLE PROVIDES A GENERAL DESCRIPTION OF THE CONTENTS OF THE SHEET. SHEET NUMBER EXAMPLE: A201 A. "A" INDICATES THE DISCIPLINE THAT CREATED THE DRAWING B. "2" INDICATES THE DRAWING CATEGORY CONTAINED ON THE SHEET C. "01" INDICATES THE SHEET NUMBER, OR IN CASE OF PLANS, THE FLOOR NUMBER 25. SHEET NUMBERS MAY INCLUDE SUPPLEMENTAL CHARACTERS TO PROVIDE ADDITIONAL INFORMATION SUCH AS DRAWING CONTENT, PROJECT SECTOR OR PHASE. 26. "DRAWING SET INDEX" INDICATES THE COMPLETE LIST OF SHEETS CONTAINED IN THE DRAWING SET, INDEXED BY DISCIPLINE, SHEET NUMBER, AND SHEET TITLE IN SEQUENTIAL ORDER. NOTE THAT ALL SEQUENTIAL SHEET NUMBERS MAY BE NOT USED IN THE DRAWING SET. 27. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL NOTIFY HOK INTERIOR ARCHITECT TO PREPARE A PUNCHLIST OF CORRECTIONS AND UNSATISFACTORY AND/OR INCOMPLETE WORK. HOK SHALL PREPARE ONE PUNCHLIST AND SHALL PERFORM ONE SUBSEQUENT REVIEW OF COMPLETED WORK AS CONFIRMATION. SHOULD MORE THAN ONE PUNCHLIST REVIEW OR MORE THAN ONE SUBSEQUENT REVIEW BE NECESSARY BECAUSE OF UNTIMELY OR INCOMPLETE WORK BY THE CONTRACTOR, THE ADDITIONAL TIME AND PROJECT REIMBURSABLES INCURRED BY HOK SHALL BE AT THE CONTRACTOR'S EXPENSE. GENERAL PROJECT NOTESGENERAL CONSTRUCTION PLAN NOTES 1. SET FINISH DOOR OPENINGS 6" FROM ADJACENT PERPENDICULAR PARTITION, UNO. 2. ALL DOOR NUMBERS TO MATCH ROOM NUMBERS INTO WHICH THEY SWING, UNO. 3. UNDERCUT AT DOORS TO BE NO LESS THAN 1/4" AND NO GREATER THAN 1/2" UNLESS SPECIFICALLY NOTED OTHERWISE FOR HVAC CONSIDERATIONS. 4. SURFACE-MOUNTED OVERHEAD CLOSER ARMS AT DOORS TO BE "PARALLEL" ARM CONFIGURATION, TYP. 5. VERIFY FIELD DIMENSIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES PRIOR TO FRAMING COMMENCEMENT. 6. GWB PARTITIONS TO BE TAPED, SPACKLED AND SANDED WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. ALL SURFACES TO BE ALIGNED. GWB SHEETS OR PANELS BETWEEN VERTICAL METAL STUD FRAMING AT NEW PARTITIONS TO NOT BOW OR "SWAY" INWARD AT FINAL INSTALLATION. VERTICAL FRAMING LOCATIONS WITHIN PARTITIONS OR TAPING COMPOUND "HILLS" TO NOT BE VISIBLE OR "TELEGRAPH" TO FINAL FINISH FACE. 7. PARTITIONS TO BE "LEVEL 4" FINISH, UNO. SKIM-COAT AND PROVIDE HAND-TROWELLED AND SANDED "LEVEL 5" FINISH AT AREAS TO RECEIVE APPLIED VINYL GRAPHICS, SPECIALTY GRAPHICS, OR WRITABLE WALL PAINT OR VINYL. SPRAY OR ROLLED "LEVEL 5" COMPOUNDS WILL NOT BE ACCEPTED. 8. WHERE FURRED OR FRAMED PARTITIONS EXCEED MAXIMUM HEIGHT, BRACE METAL TO ADJACENT STRUCTURE. 9. ALL PENETRATIONS OR OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, AND WEATHER PROOFED. 10. MAINTAIN REQUIRED ACOUSTICAL RATINGS WHERE PARTITIONS ARE PIERCED BY CABLE TRAY, CONDUIT, DUCTS, PIPES, STEEL, OR SIMILAR ITEMS. 11. WHERE CABLE TRAY PENETRATES PARTITION, PROVIDE FULLY FINISHED EDGE TRIMS AND BRAKE METAL SLEEVE(S) TO YIELD CLEAN APPEARANCE. TAPE AND SPACKEL TRIMS INTO GWB. ALL TO BE PAINTED TO MATCH PARTITION. 12. PROVIDE ADDITIONAL METAL STUD ANCHOR BRACKETS, BLOCKING, AND FRAMING AT LOCATIONS INCLUDING, BUT NOT LIMITED TO, GRAB BARS, SHELVING, COAT RODS, OVERHEAD CABINETS, MILLWORK, RUNNING TRIMS, HANDRAILS, SIGNAGE, TOILET ROOM ACCESSORIES, DOOR FRAMES, DOOR HARDWARE, AND SIMILAR ITEMS. SEE FRAMING GUIDES AT A600-SERIES DRAWINGS. 13. DIMENSIONS TO THE EXTERIOR WALL ARE TO THE INSIDE FACE OF EXISTING SILL EDGE, UNO. 14. ALL CONCEALED WOOD TO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH CODES. 15. GWB PARTITIONS RECEIVING RESILIENT BASE TO BE FINISHED SMOOTH TO THE SLAB TO YIELD SMOOTH AND CONSISTENT BASE INSTALLATION. 16. PATCH AND REPAIR EXISTING SLAB FOR NEW FLOOR FINISHES. TO BE LEVELED AND SEALED FOR PROPER INSTALLATION OF FINISH FLOOR MATERIALS AND WALL BASES. 17. PATCH AND REPAIR EXISTING PARTITIONS FLAT AND SMOOTH IN PREPARATION FOR NEW WALL FINISHES. SKIM- COAT AND PROVIDE HAND-TROWELLED AND SANDED COMPOUNDS AS REQUIRED. PATCH SURFACES IN A MANNER TO ELIMINATE EVIDENCE OF PATCHING PROCESS. 18. DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES. DIMENSIONS TO BE ACCURATELY MAINTAINED AND SHALL NOT VARY MORE THAN +/-1/8" WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. 19. DIMENSIONS NOTED "HOLD" MUST BE ACCURATELY MAINTAINED AND SHALL NOT VARY MORE THAN +/-1/8" WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. 20. MILLWORK AND CASEWORK TO BE PREMIUM GRADE OR BETTER. MATERIAL AND FABRICATION OF MILLWORK TO BE IN ACCORDANCE WITH MOST CURRENT EDITION OF THE ARCHITECTURAL WOODWORKING STANDARDS (AWS) OF CONSTRUCTION FOR PREMIUM GRADE MILLWORK AS DEVELOPED BY THE ARCHITECTURAL WOODWORK INSTITUTE (AWI). MATERIAL TO BE FOREST STEWARDSHIP COUNCIL (FSC) CERTIFIED AND DOCUMENTED. 21. PROVIDE NEW CODE-REQUIRED IDENTIFICATION SIGNAGE. TO BE ADA-COMPLIANT. SIGNAGE TO INCORPORATE BRAILLE AND RAISED CHARACTERS AT ALL SIGNS. 22. PROVIDE FIRE PROOFING MATERIAL TO NEW CONSTRUCTION AS REQUIRED BY APPLICABLE CODES. RE-APPLY FIRE PROOFING TO MAINTAIN FIRE RATING WHEREVER NEW CONSTRUCTION IS ANCHORED FIRMLY AND DIRECTLY TO EXISTING FIRE RATED CONSTRUCTION. 23. REMOVE EXISTING ABANDONED DEVICES, RELATED CONDUITS, AND EQUIPMENT AT EXISTING PARTITIONS THROUGHOUT, UNO. ITEMS INCLUDE, BUT ARE NOT LIMITED TO, FIRE EXTINGUISHER CABINETS, WALL MOUNTED HVAC DIFFUSERS, ALARM DEVICES, NOTIFICATION DEVICES, LIGHT CONTROLS, SECURITY DEVICES, THERMOSTATS, AND POWER OR COMMUNICATION / DATA RECEPTACLES NOT TO BE REUSED. PATCH PARTITION SMOOTH TO ELIMINATE EVIDENCE OF REMOVAL PROCESS. 24. DASHED RECTANGLES AT DOOR LOCATIONS ILLUSTRATED ON PLAN INDICATE OPEN FLOOR CLEARANCES REQUIRED FOR ACCESSIBILITY. DASHED AREAS INDICATED ARE MINIMUMS. NO CONSTRUCTION, INCLUDING APPLIED WALL BASE OR PROTRUSIONS / ENCROACHMENTS RESULTING FROM "CONSTRUCTION TOLERANCES," WILL BE ACCEPTED WITHIN DASHED REGIONS. 25. PATCH OR PROVIDE NEW APPROVED ACOUSTICAL SEALANTS AND ASSEMBLIES OR FIRESTOPPING SEALANTS AND ASSEMBLIES AT PENETRATIONS IN ACOUSTICAL OR FIRE-RATED PARTITIONS, EXISTING AND NEW SHAFTWALLS, FLOOR SLABS, ROOF ASSEMBLIES, AND EXTERIOR WALLS. PENETRATIONS INCLUDE, BUT ARE NOT LIMITED TO, DUCTS, PIPES, CONDUITS, CABLE TRAYS, STRUCTURAL ELEMENTS, AND SIMILAR ITEMS. FIRE SAFE PENETRATIONS PER APPLICABLE UL ASSEMBLIES. 26. AT ABANDONED PENETRATIONS IN FLOOR SLAB, PATCH OPENING WITH METAL DECKING FROM BELOW TO MATCH EXISTING DECKING AND FILL FROM ABOVE WITH CONCRETE TO MATCH EXISTING CONCRETE MIX. DOWEL INFILL INTO EXISTING SLAB TO RESIST UPLIFT. PROVIDE A SMOOTH SURFACE FOR INSTALLATION OF NEW FLOOR FINISHES. PROVIDE ADDITIONAL FIRE-PROOFING OR SEALANTS AS REQUIRED TO RESTORE AND MAINTAIN SLAB FIRE RATING CONTINUITY. 1. SURVEY FIELD CONDITIONS AND VERIFY THAT WORK IS FEASIBLE AS SHOWN. VERIFY LOCATION OF ALL OUTLETS IN RELATION TO STRUCTURAL AND OTHER ELEMENTS AS REQUIRED. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 2. SEE TYPICAL DEVICE MOUNTING ELEVATION AT SYMBOLS AND ANNOTATIONS LEGEND SHEET FOR MOUNTING HEIGHTS AND ALIGNMENT REQUIREMENTS FOR WALL-MOUNTED DEVICES. POWER AND DATA RECEPTACLES TO BE MOUNTED VERTICALLY 18" AFF, UNO. RECEPTACLE CLUSTERS TO BE MOUNTED TIGHT TOGETHER WITH A MINIMUM OF SPACE BETWEEN. PROVIDE ADDITIONAL CONCEALED FRAMING TO ACCOMMODATE TIGHT SPACING. 3. CONTRACTOR TO COORDINATE FOR ARCHITECT APPROVAL OF DEVICE ALIGNMENTS. TO INCLUDE, BUT IS NOT LIMITED TO, ELECTRICAL, DATA, SECURITY, THERMOSTAT, AV, LIGHT CONTROL, MONITORING AND SIMILAR DEVICES. TO BE APPROVED PRIOR TO CABLING AND PARTITION CLOSING. 4. ELECTRICAL AND/OR DATA RECEPTACLES TO BE LOCATED EITHER CENTERED ON COLUMN ENCLOSURE WIDTH, CENTERED ON PARTITION LENGTH, OR TO BE 12" FROM NEAREST CORNER OR DOOR AS SHOWN ON PLAN. 5. COORDINATE INSTALLATION OF ADDITIONAL FRAMING, CONDUIT, JUNCTION BOXES, PULL STRINGS AND COVER PLATES WITH COMMUNICATIONS AND SECURITY PROVIDERS. TO BE PROVIDED BY CONTRACTOR. 6. PROVIDE REQUIRED POWER FOR SECURITY AND MONITORING DEVICES. COORDINATE WITH SECURITY VENDOR. 7. WHERE CARD READERS, SECURED ACCESS, OR MONITORING IS CALLED FOR, PROVIDE ELECTRICAL SERVICES, ADDITIONAL FRAMING, JUNCTION BOXES, AND CONTINUOUS CONDUIT RUNS AS REQUIRED TO ACCOMMODATE DEVICES AND TIE-INS FOR A FULLY OPERATIONAL SYSTEM. COORDINATE WITH SEPARATE SECURITY VENDOR. SYSTEMS COMPONENTS TO INCLUDE, BUT ARE NOT LIMITED TO, CARD READER, REQUEST TO EXIT BUTTON, CEILING MOUNTED MOTION SENSOR, ELECTRIFIED HARDWARE, AND DOOR CONTACTS. CONNECT TO BUILDING ALARM AND NOTIFICATION SYSTEM. 8. COORDINATE DEVICE MOUNTINGS WITHIN MILLWORK FOR CONCEALED CABLE ROUTING AND TO INSURE FLUSH FINAL INSTALLATION OR INSTALLATION CONFIGURATION AS INDICATED IN DETAILS. 9. PROVIDE GFI ELECTRICAL RECEPTACLES IN MOIST OR "WET" AREAS OR WHERE RECEPTACLES ARE CLOSER THAN 6 FEET FROM A SINK, WATER DISPENSER, ICE DISPENSER, OR DRINKING FOUNTAIN. 10. PROVIDE AND INSTALL WORK IN ACCORDANCE WITH THE NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITY COMPANIES, DATA / VOICE SUBSCRIPTION COMPANIES, AND ALL AUTHORITIES HAVING JURISDICTION. 11. ALL MATERIALS AND DEVICES SHALL CONFORM WITH THE STANDARDS OF UNDERWRITERS LABORATORIES, INC. (UL) IN EVERY CONDITION WHERE SUCH A STANDARD HAS BEEN ESTABLISHED FOR THE PARTICULAR TYPE OF MATERIAL. FURNISH AND INSTALL UL LABELED DEVICES THROUGHOUT. 12. COORDINATE AND VERIFY EQUIPMENT POWER REQUIREMENTS, RECEPTACLE TYPES, AND MOUNTING HEIGHTS WITH EQUIPMENT MANUFACTURERS' RECOMMENDATIONS, SPECIFICATIONS AND INSTRUCTIONS PRIOR TO POWER DISTRIBUTION AND RECEPTACLE INSTALLATION. 13. FURNITURE IS SHOWN FOR REFERENCE PURPOSES ONLY, UNO. 14. ARCHITECTURAL DRAWINGS DETERMINE LOCATION AND GENERAL TYPE OF DEVICES. ELECTRICAL ENGINEERS' DOCUMENTS SHALL GOVERN THE WIRING LAYOUT AND INSTALLATION IN COMPLIANCE WITH LAWS APPLICABLE AND ENFORCED BY GOVERNING AUTHORITIES. 15. OUTLETS SHOWN BACK TO BACK ON PARTITIONS SHALL BE OFFSET WITH A STUD BETWEEN. 16. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR CONDUIT OR PLUMBING LINES SHALL BE FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE BUILDING AND FIRE CODES. FIRE SAFE PENETRATIONS PER APPLICABLE UL ASSEMBLIES. 17. DIMENSIONS ARE TO CENTERLINE OF RECEPTACLE, DEVICE, OR GROUP OF RECEPTACLES, UNO. 18. MAINTAIN A MINIMUM 3 INCH HORIZONTAL CLEARANCE IN ALL DIRECTIONS FROM EDGE OF COVER PLATE FOR WALL MOUNTED OUTLETS. MAINTAIN A MINIMUM 4 INCH CLEARANCE IN PLAN FROM EDGE OF MONUMENT OR FLOOR DEVICE WHEN ADJACENT TO A WALL, COLUMN, OR SIMILAR ELEMENT, UNO. 19. ELECTRICAL, LIGHTING CONTROL, AND DATA COVER PLATES AS WELL AS SURFACE HARDWARE AND SIMILAR ITEMS SHALL BE INSTALLED AFTER PAINTING AND/OR APPLICATION OF WALL COVERINGS. 20. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR ELECTRICAL, DATA, CONTROL DEVICES AND LIGHT FIXTURES TO COORDINATE WITH DEPTH OF INTERIOR FINISHES AND MILLWORK OR CASEWORK. DEVICES AND FACE PLATES TO INSTALL FLUSH AND FLAT TO FINISH FACES. 21. ELECTRICAL RECEPTACLES, DATA OR COMMUNICATION RECEPTACLES, SWITCHING OR CONTROL DEVICES, AND SIMILAR ITEMS TO BE "DECORA-STYLE", UNO. 22. CONTRACTOR TO COORDINATE COLOR FINISH OF ELECTRICAL RECEPTACLE, DATA OR COMMUNICATION RECEPTACLE, SECURITY, OPERATING, MONITORING, SWITCHING DEVICES AND COVER PLATES WITH COLOR OF FINISH WALL OR SURFACE ON TO WHICH THEY ARE MOUNTED. DEVICES AND COVER PLATES TO BE BLACK AT "DARK" TONE WALLS OR SURFACES, TO BE GREY AT "MEDIUM" TONE WALLS OR SURFACES, TO BE BROWN AT WOOD PANEL WALLS OR SURFACES, AND TO BE WHITE ELSEWHERE. COORDINATE WITH INTERIOR ARCHITECT FOR "DARK" AND "MEDIUM" TONE WALL OR SURFACE FINISH CLASSIFICATIONS. PROVIDE FULL RANGE OF DEVICE AND COVER PLATE FACTORY FINISHES FOR EACH DEVICE TYPE FOR ARCHITECTS' COLOR SELECTION. 23. DATA OR COMMUNICATION RECEPTACLE COVER PLATES AND KEYSTONE FACE PLATES TO MATCH COLOR OF TYPICAL ELECTRICAL RECEPTACLE DEVICE AND COVER PLATES AT SAME AREA. WHITE IS TO MATCH WHITE. IVORY IS TO MATCH IVORY. GREY IS TO MATCH GREY. BROWN IS TO MATCH BROWN. BLACK IS TO MATCH BLACK. 24. ADJACENT WALL-MOUNTED RECEPTACLES TO BE GANGED WITH A COMMON FACE PLATE. IF RECEPTACLES CANNOT BE GANGED, INSTALL WITH A MINIMUM DISTANCE BETWEEN UNITS. PROVIDE ADDITIONAL FRAMING. 25. ADJACENT WALL-MOUNTED SWITCHES OR CONTROLS TO BE GANGED WITH A COMMON FACE PLATE. MAXIMUM FACE PLATE WIDTH TO ACCOMMODATE FIVE (5) SWITCHES OR CONTROLS. WHEN MORE THAN FIVE OCCUR, DIVIDE QUANTITY INTO TWO GANGED CLUSTERS THAT ARE STACKED. MAXIMUM HEIGHT OF TOP CLUSTER TO BE 48" TO TOP EDGE OF PLATE. SEE ALSO TYPICAL DEVICE MOUNTING ELEVATION GUIDE AT G0XX-SERIES SHEETS. 26. REMOVE EXISTING ABANDONED DEVICES, RELATED CONDUITS, AND EQUIPMENT AT EXISTING PARTITIONS THROUGHOUT, UNO. ITEMS INCLUDE, BUT ARE NOT LIMITED TO, ALARM DEVICES, NOTIFICATION DEVICES, LIGHT CONTROLS, SECURITY DEVICES, THERMOSTATS, AND POWER OR COMMUNICATION / DATA RECEPTACLES NOT TO BE REUSED. PATCH PARTITION SMOOTH TO ELIMINATE EVIDENCE OF REMOVAL PROCESS. 27. WHERE ELECTRICAL OR COMMUNICATION RECEPTACLES OCCUR IN FIRE-RATED OR ACOUSTICALLY RATED CONSTRUCTION, PROVIDE JUNCTION BOX AND 1-1/4" CONDUIT STUBBED TO 6" ABOVE FINISHED CEILING. WHERE CEILING IS OPEN TO SLAB ABOVE, CONDUIT TO BE RIGID AND TO BE STUBBED MAXIMUM 3" FROM UNDERSIDE OF STRUCTURAL SLAB ABOVE. PROVIDE PULL STRING FOR LOW-VOLTAGE PROVIDERS' USE. 28. FURNITURE SYSTEMS CONNECTIONS (WHIPS) TO BE PROVIDED BY SEPARATE FURNITURE VENDOR AND TO BE HARDWIRED BY CONTRACTOR. ELECTRICAL BASE FEED INSTALLATION WITHIN FURNITURE SYSTEMS TO BE BY SEPARATE FURNITURE INSTALLER. CONTRACTOR TO PROVIDE ELECTRICAL SERVICES, JUNCTION BOXES, AND CONDUIT AS REQUIRED FOR HARDWIRE CONNECTION. CONTRACTOR TO PROVIDE COORDINATION TIME AND OUT- OF-TYPICAL-SEQUENCE ACCOMMODATIONS. 29. WHERE ELECTRICAL, VOICE/DATA AND/OR AUDIO/VISUAL RECEPTACLES ARE TO BE INSTALLED WITHIN CONFERENCE FURNITURE AT TABLE TOP LEVEL, SEPARATE FURNITURE MANUFACTURER TO PROVIDE BLANK MOUNTING BOXES AT TABLE TOP. CONTRACTOR TO PROVIDE JUNCTION BOXES, DEVICES, DEVICE FACE PLATES, AND CONTINUOUS CABLE AND CONDUIT RUNS TO FIT WITHIN FURNITURE COMPONENTS. CONTRACTOR TO PROVIDE COORDINATION TIME AND OUT-OF-TYPICAL-SEQUENCE ACCOMMODATIONS. UNO, EACH TABLE TOP LOCATION TO HAVE DUPLEX ELECTRICAL RECEPTACLES, MULTI-PORT VOICE/DATA RECEPTACLES AND AV RECEPTACLE. COORDINATE FINAL QUANTITIES AND TYPES WITH OWNER. COORDINATE WITH SEPARATE FURNITURE PROVIDER, NEW FIRE-STOPPED POKE-THRU AT FLOOR LEVEL, AND TENANT REPRESENTATIVE. DEVICES AND FACE PLATES WITHIN TABLE BOXES TO BE BLACK. ALL CONDUITS, CABLES, AND FASTENERS TO BE CONCEALED FROM VIEW AT FINAL INSTALLATION. PROVIDE CLIPS AND FINISHED FASTENERS TO YIELD COMPLETE AND TIDY INSTALLATION. 30. PROVIDE ADJUSTABLE OCCUPANCY SENSORS FOR CONTROL OF LIGHTS AT ALL ENCLOSED AREAS OR ROOMS. SENSOR TO BE SET AND TESTED TO "15 MINUTE DURATION" UNO. COORDINATE WITH ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION. GENERAL POWER AND DATA PLAN NOTES 1. NEW CEILINGS TO MATCH EXISTING CEILING HEIGHT, UNO. 2. SEE TYPICAL DEVICE MOUNTING ELEVATION AT SYMBOLS AND ANNOTATIONS LEGEND SHEET FOR MOUNTING HEIGHTS AND ALIGNMENT REQUIREMENTS FOR WALL-MOUNTED DEVICES. 3. VERIFY CEILING HEIGHTS AND CEILING PLENUM CLEARANCES TO ASSURE FINISHED CEILING HEIGHTS CALLED OUT ON INTERIOR ARCHITECTURE DOCUMENTS CAN BE ACHIEVED. BRING DISCREPANCIES TO INTERIOR ARCHITECTS' ATTENTION PRIOR TO COMMENCEMENT OF WORK. 4. WALL-MOUNTED STROBES TO BE LOCATED AT 80" AFF TO VERTICAL CENTERLINE. HORIZONTAL CENTERLINE TO ALIGN WITH ELECTRICAL RECEPTACLE, LIGHT SWITCH, OR THERMOSTAT AT SAME PARTITION. SEE ENGINEER'S DRAWINGS FOR LOCATIONS AND SPECIFICATIONS. COORDINATE ALIGNMENTS WITH ARCHITECT ON SITE. 5. DETECTION AND NOTIFICATION DEVICE (SUCH AS SMOKE DETECTORS, FIRE STROBES, FIRE HORNS, ANTENNAE) LOCATIONS TO BE COORDINATED BY CONTRACTOR TO ALIGN WITH NEARBY DEVICES OR EQUIPMENT. SUBMIT TO INTERIOR ARCHITECT FOR FINAL ALIGNMENT APPROVAL PRIOR TO ROUGH-IN AND WIRING. 6. CONTRACTOR TO COORDINATE FOR ARCHITECT APPROVAL OF DEVICE AND EQUIPMENT LOCATIONS AND ALIGNMENTS TO BE INSTALLED AT GWB CEILINGS. TO INCLUDE, BUT IS NOT LIMITED TO, LOCATIONS OF SLOT DIFFUSERS, SPOT DIFFUSERS, SPRINKLERS, MONITORING DEVICES, NOTIFICATION DEVICES, LIGHT FIXTURES, ANTENNAE, AV ROUGH-INS, AND SIMILAR ITEMS. TO BE APPROVED PRIOR TO CABLING AND CEILING CLOSING. 7. INSTALL SUSPENDED CEILING GRID TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12'-0". CEILING HEIGHTS SHALL BE MEASURED FROM THE HIGH POINT OF PATCHED FLOOR SLAB. CEILINGS INDICATED TO BE THE SAME HEIGHT ARE TO ALIGN VERTICALLY FOR FULL PROJECT. COORDINATE WITH FULL-HEIGHT DOORS AND PERIMETER SOFFIT CONFIGURATION. CEILING ASSEMBLIES TO BE LATERALLY BRACED. 8. GRIDS AT OPPOSITE SIDES OF GLASS WALLS TO ALIGN FROM SIDE-TO-SIDE TO APPEAR AS-IF CONTINUOUS, UNO. 9. UNDERCABINET LIGHTING TO BE INDEPENDENTLY CONTROLLED AT EACH LOCATION. CONTINUOUS LENGTH OF UNDERCABINET LIGHTING AT SINGLE RUN TO BE CONTROLLED AS ONE. 10. INTERIOR ARCHITECTURE REFLECTED CEILING PLANS INDICATE: GENERAL TYPE AND SPECIFIC LOCATIONS OF LIGHT FIXTURES, GENERAL TYPE AND SPECIFIC LOCATIONS OF EXIT SIGNS, AND GENERAL TYPE AND GENERAL LOCATIONS OF AV EQUIPMENT. 11. ELECTRICAL ENGINEERING DRAWINGS INDICATE: A) CIRCUITING AND WIRING OF LIGHT FIXTURES AND CONTROLS, B) LIFE SAFETY EQUIPMENT, C) LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES, AND D) LIGHT FIXTURE SPECIFICATIONS. 12. MECHANICAL ENGINEERING DRAWINGS INDICATE: A) DUCTS AND AIR MOVEMENT REQUIREMENTS, AND B) GRILLE AND REGISTER SPECIFICATIONS AND SIZES. 13. DESIGN-BUILD FIRE PROTECTION DRAWINGS INDICATE: A) GEOMETRY, LOCATION, AND SIZE OF SPRINKLER LINES, B) SPRINKLER HEAD LOCATIONS IN SPECIALTY AREAS ONLY, C) PRESSURE REQUIREMENTS, AND D) SPRINKLER HEAD SPECIFICATIONS. 14. WHERE ACOUSTICAL CEILING PANELS OR TILES ARE REQUIRED TO BE CUT, CUT TO MAINTAIN SHARP, CLEAN AND NEAT EDGE. WHEN CUT EDGE IS EXPOSED TO VIEW AT FINAL INSTALLATION, REFINISH CUT EDGE TO MATCH FACE FINISH OF PANEL OR TILE. 15. INSTALL LIGHT FIXTURES, SPRINKLER HEADS, SPOT DIFFUSERS, MONITORING DEVICES, NOTIFICATION DEVICES, ANTENNAE, AND SIMILAR ITEMS CENTERED ON LAY-IN PANELS IN SUSPENDED CEILING AREAS, UNO. 16. EMERGENCY LIGHTING AND ILLUMINATED EXIT LIGHTING OR SIGNAGE SHALL BE WIRED TO THE BUILDING'S EMERGENCY WIRING SYSTEM AND KEPT INDEPENDENT OF OTHER WIRING SYSTEMS. 17. NO ACCESS PANELS TO OCCUR AT ANY GWB CEILINGS WITHOUT THE WRITTEN CONSENT OF INTERIOR ARCHITECT. WHEN PRESENT, ACCESS PANEL TO BE CENTERED ON CEILING FEATURES OR ADJACENT DEVICES. TO BE TRIMLESS GFRG-TYPE PANEL WITH TAPED-AND-SPACKLED FRAME EDGE AND NO EXPOSED FASTENERS. 18. WHEN MORE THAN ONE OPERATING OR MONITORING DEVICE OR SWITCH OCCURS IN ONE LOCATION, GANG DEVICES TOGETHER AND PROVIDE A COMMON SWITCH PLATE COVER. 19. DIMENSIONS ARE TO CENTERLINE OF VISIBLE FIXTURE OR DEVICE, UNO. 20. PROVIDE ADDITIONAL CONCEALED FRAMING, BLOCKING, AND ANCHORING ABOVE CEILINGS AS REQUIRED FOR SUPPORT OF CEILING-MOUNTED FIXTURES, EQUIPMENT, OR DEVICES. PROVIDE LATERAL BRACING. 21. CONTRACTOR TO COORDINATE COLOR FINISH OF OPERATING, SECURITY, MONITORING, ANTENNAE, SWITCHING DEVICES AND COVER PLATES WITH COLOR OF FINISH WALL OR SURFACE ON TO WHICH THEY ARE MOUNTED. WHEN INSTALLED AT OPEN CEILING AREAS, ITEMS TO BE COORDINATED WITH GENERAL OVEHEAD PAINT COLOR. DEVICES AND COVER PLATES TO BE BLACK AT "DARK" TONE SURFACES OR AREAS, TO BE GREY AT "MEDIUM" TONE SURFACES OR AREAS, TO BE BROWN AT WOOD PANEL WALLS OR SURFACES, AND TO BE WHITE ELSEWHERE. COORDINATE WITH INTERIOR ARCHITECT FOR "DARK" AND "MEDIUM" TONE WALL, SURFACE, OR AREA FINISH CLASSIFICATIONS. PROVIDE FULL RANGE OF DEVICE AND COVER PLATE FACTORY FINISHES FOR EACH DEVICE TYPE FOR ARCHITECTS' COLOR SELECTION, INCLUDING BLACK, GREY, BROWN AND WHITE. 22. IN ADDITION TO QUANTITY OF EXIT SIGNS SHOWN ON PLANS, PROVIDE FOR TEN PERCENT, BUT NO FEWER THAN FIVE (5), ADDITIONAL ILLUMINATED EXIT SIGNS PER FLOOR TO BE INSTALLED OR RELOCATED ON SITE AT THE DIRECTION OF ARCHITECT OR LOCAL JURISDICTIONAL INSPECTOR(S). TO MATCH PROJECT TYPICAL INTERNALLY ILLUMINATED EXIT SIGN AND MOUNTING FOR EACH LOCATION TYPE. 23. WALL MOUNTED FIRE STROBES OR HORNS HOUSINGS TO BE WHITE. CEILING MOUNTED FIRE STROBES OR HORNS HOUSINGS TO BE WHITE. GENERAL REFLECTED CEILING PLAN NOTES 1. SEE SHEET [A301] FOR FINISH LEGEND. 2. NEW PARTITIONS TO BE FINISHED PT-1, UNO. 3. EXISTING WINDOW TREATMENTS TO REMAIN FOR REUSE, UNO. INVENTORY AND TEST TO ASSURE ALL ARE COMPLETE WITH TRIMS AND ARE IN GOOD WORKING ORDER. REPAIR, AUGMENT, OR REPLACE WITH NEW TO MATCH EXISTING ANY WINDOW TREATMENTS FOUND TO BE DAMAGED OR NOT FULLY OPERATIONAL. ADDITIONALLY COORDINATE WITH BASE BUILDING REPRESENTATIVE. CLEAN PRIOR TO TENANT MOVE-IN. 4. RESILIENT BASE TO BE COVE PROFILE CONFIGURATION WITH HARD SURFACE FLOORING AND TO BE STRAIGHT PROFILE CONFIGURATION WITH CARPET. RESILIENT BASE TO BE INSTALLED IN 100 FOOT ROLLED LENGTHS, NOT 4'-0" OR 8'-0" LENGTHS. PROVIDE CONTINUOUS ADHESION BETWEEN PARTITION AND RESILIENT BASE. INSTALLED BASE TO BE SMOOTH WITH NO RIPPLES. NO SEAMS OR JOINTS IN BASE TO BE CLOSER THAN 4'-0" TO INSIDE OR OUTSIDE CORNERS. NO SEAMS OR JOINTS IN BASE AT OUTSIDE CORNERS WILL BE ACCEPTED. 5. CLOSETS TO BE FINISHED TO MATCH ADJOINING SPACES, INCLUDING FLOOR, PAINT(S), WALL BASE AND CEILING FINISHES. 6. PAINT FINISHING TO BE MINIMUM ONE COAT OF BASE PRIMER WITH TWO COATS OF FINISH PAINT. PRIMER COAT TO BE TINTED SIMILAR TO FINISH COAT COLOR. PROVIDE ADDITIONAL PRIMER COATS OR FINISH PAINT COATS TO FULLY CONCEAL EXISTING FINISHES OR SUBSURFACES AND TO YIELD CONTINUOUS COVERAGE WITHOUT BLEMISHES OR COLOR VARIATION. GWB SURFACES TO BE WIPED WITH A DAMP CLOTH PRIOR TO APPLICATION OF FIRST COAT OF PRIMER TO REMOVE DUST FROM SANDING PROCESS. FINISH SHEEN AT PARTITIONS TO BE EGGSHELL, UNO. FINISH SHEEN AT DOOR FRAMES, DOORS, RUNNING APPLIED TRIMS AND WALL BASE TO BE SEMI-GLOSS, UNO. FINISH SHEEN AT CEILINGS TO BE FLAT, UNO. 7. FLOOR FINISH TRANSITIONS BETWEEN ROOMS TO BE SEAMED AT CENTERLINE OF DOOR IN CLOSED POSITION, UNO. PROVIDE TRANSITION STRIPS, TRIMS, AND THRESHOLDS AS CALLED FOR IN A900-SERIES DETAILS FOR EACH MATERIAL INTERSECTION. 8. FLOOR FINISH TRANSITIONS BETWEEN CARPET AND HARD SURFACE TO INCLUDE CONTINUOUS METAL EDGE STRIP TO PROTECT HARD SURFACE EDGE. HARD SURFACE TO INCLUDE, BUT IS NOT LIMITED TO, STONE, CERAMIC, WOOD, CONCRETE TOPPING SLAB, FLUID-APPLIED RESINOUS FLOORING, FINISHED ACCESS FLOOR PANELS, AND SIMILAR SURFACES. SEE DETAILS FOR ADDITIONAL INFORMATION. 9. FINISHES TO BE "CLASS A" OR "CLASS 1" AS PER ASTM E 84 TESTING THROUGHOUT. 10. PROVIDE MINIMUM OF THREE (3) 8" X 10" BRUSH-OUTS OF EACH PAINT COLOR AND FINISH FOR INTERIOR ARCHITECT REVIEW AND APPROVAL PRIOR TO MATERIAL PURCHASE. AT INTERIOR ARCHITECT'S DISCRETION, PROVIDE 24" SQUARE ON-SITE PAINT SAMPLE APPLICATION WITH FINAL LIGHTING IN PLACE FOR COLOR REVIEW AND APPROVAL PRIOR TO MATERIAL PURCHASE. INTERIOR ARCHITECT RESERVES THE RIGHT TO ADJUST ANY COLOR/FINISH ONCE AN IN-PLACE WALL PAINT TEST HAS BEEN MADE. 11. MATERIAL AND FABRICATION OF MILLWORK TO BE IN ACCORDANCE WITH MOST CURRENT EDITION OF THE ARCHITECTURAL WOODWORKING STANDARDS (AWS) OF CONSTRUCTION FOR PREMIUM GRADE MILLWORK AS DEVELOPED BY THE ARCHITECTURAL WOODWORK INSTITUTE (AWI). MATERIAL TO BE FOREST STEWARDSHIP COUNCIL (FSC) CERTIFIED AND DOCUMENTED. 12. PAINT GRADE WOODWORK TO BE SHOP FINISHED WITH ON-SITE TOUCH-UP. ON-SITE INSTALLATION FINISH NAIL HEADS AND HOLES TO BE FILLED AND TOUCHED UP FOR CONTINUOUS APPEARANCE. 13. HIGH PRESSURE DECORATIVE LAMINATE (HPDL, ALSO TERMED "PLASTIC LAMINATE" IN DOCUMENTS) WORK TO COMPLY WITH AWI STANDARDS, CURRENT EDITION. SUBSTRATE TO BE MEDIUM DENSITY FIBERBOARD OR BETTER. HPDL TYPE "HGS" TO BE USED FOR HORIZONTAL SURFACES. HPDL TYPE "VGS" TO BE USED ON VERTICAL SURFACES. OPEN CABINETRY TO BE PLASTIC LAMINATE ON ALL EXPOSED SURFACES. CLOSED CABINETRY INTERIORS TO BE PLASTIC LAMINATE AT ADJUSTABLE SHELVES, INSIDE FACES OF SWING DOORS, AND BOTTOM SURFACES OF CABINETS. PROVIDE WHITE OR BLACK MELAMINE AT ARCHITECT'S DISCRETION TO ALL OTHER INTERIOR SURFACES, UNO. 14. PROVIDE 5% ADDITIONAL ATTIC STOCK OR FUTURE MAINTENANCE MATERIAL, BUT NOT LESS THAN ONE FULL BOX, BUCKET, OR ROLL, FOR EACH TYPE OF THE FOLLOWING MATERIALS: CARPET, RESILIENT FLOORING, RESILIENT BASE, CERAMIC TILE, WALL COVERING, UPHOLSTERY, EACH PAINT COLOR, AND ACOUSTICAL CEILING TILES. EACH TO BE NEATLY BOUND AND PROTECTED, READY FOR STORAGE. EACH TO BE CLEARLY LABELED IN ENGLISH, INDICATING PROJECT FINISH CODE, MANUFACTURER, AND COLORWAY. COORDINATE WITH TENANT REPRESENTATIVE FOR FINAL ATTIC STOCK DELIVERY LOCATION WHICH MAY BE DIFFERENT THAN PROJECT LOCATION. GENERAL FINISH PLAN NOTES Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:32 PMGENERAL NOTES G002 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. DOOR AND FRAME CARD READER, THERMOSTAT, or AV CONTROL PANEL WALL MOUNTED TELEPHONE LIGHT SWITCH, OCCUPANCY SENSOR, OR BANK OF DEVICES. 5 GANG MAX. FIRE STROBE OR SPEAKER ELECTRICAL DUPLEX OR QUAD VOICE / DATA RECEPTACLE 1'-6"3'-6"4' - 0" TO TOP EDGE6'-8" TO BOTTOM OF LENS6" MAX O.C.6". CENTERLINE OF ALL DEVICES TO ALIGN AS SHOWN. PROVIDE ADDITIONAL METAL STUD FRAMING AS REQUIRED FOR EXACT PLACEMENTS. CL NOTE: DIMENSIONS GIVEN ARE FROM EDGE OF FINISHED DOOR FRAME OR, IN INSTANCES WHERE A SIDELIGHT OR GLAZING IS DIRECTLY ADJACENT TO THE DOOR, EDGE OF DOOR IN FULL OPEN POSITION ON PERPENDICULAR PARTITION.5'-0"IDENTIFICATION SIGNAGE, WHEN NO BRAILLE IS INCLUDED 6". CL WHEN MORE THAN 5 SWITCHES OR CONTROLS OCCUR, GANG IN TWO BANKS AND STACK AS SHOWN. 4' - 0" TO TOP EDGE3"FIRE STROBE OR SPEAKER CL 1'-6"TOP OF FEC4'-6"6'-8"CENTER LINE OF FIRE EXTINGUISHER CABINET. CONVENIENCE ELECTRICAL RECEPTACLE CENTERLINE OF ALL DEVICES TO ALIGN AS SHOWN. PROVIDE ADDITIONAL CONCEALED METAL STUD FRAMING AS REQUIRED FOR EXACT PLACEMENTS.IDENTIFICATION SIGNAGE, WHEN BRAILLE IS INCLUDED 5" 9" MIN 3'-6" SWITCHES LINE OF DOOR WHEN OPEN AV CONTROL PANEL WHERE OCCURS STROBE FIN FLOOR SEE 1/G010 FOR TYP. MOUNTING HEIGHTS SWITCHES COLUMN STROBE EQ EQ VOICE/DATA/POWER DEVICES FIN FLOOR SEE 1/G010 FOR TYP. MOUNTING HEIGHTS1" FIN FLOOR 1'-0" SWITCHES EDGE OF WALL STROBE VOICE/DATA/POWER DEVICES 1"SEE 1/G010 FOR TYP. MOUNTING HEIGHTS PENDANT EXIT SIGN FRONT ELEVATION PENDANT EXIT SIGN SIDE ELEVATION DETAIL KEYNOTE LEGEND NOTE:SEE ALSO GENERAL OPEN CEILING NOTES AT SHEET G002 FOR ORGANIZATIONAL AND ALIGNMENT REQUIREMENTS. A. DATUM LINE FOR LIGHT FIXTURE AND DEVICE MOUNTING HEIGHT. COORDINATE WITH AV AND TECHNOLOGY CONSULTANTS. B. STRUCTURAL SLAB ABOVE. METAL DECKING SHOWN FOR REFERENCE. CONFIRM SLAB CONFIGURATION ON SITE. C. PROVIDE METAL BRIDGING PLATE AS REQUIRED ANCHORED TO DECKING TO ALLOW FOR EXACT PLACEMENT OF PENDANT FIXTURE OR DEVICE. DEVICE JUNCTION BOXES TO BE INSTALLED TIGHT TO UNDERSIDE OF DECK. D. NOMINAL 4" x 4" x 2" WELDED STEEL SQUARE JUNCTION BOX. E. NOMINAL 4" x 4" x 2" WELDED STEEL OCTAGONAL JUNCTION BOX. F. CONTINUOUS GALVANIZED RIGID CONDUIT BENT TO MOUNT TIGHT TO UNDERSIDE OF STRUCTURAL DECK ABOVE WITH CONDUIT STRAPS. G. LED EXIT SIGN WITH REFLECTIVE MYLAR INTERLAYER. TOP EDGE OF EXIT PLAQUE TO ALIGN WITH BOTTOM FACE OF LIGHT FIXTURE. H. SCHEMATIC LINEAR PENDANT LIGHT FIXTURE WITH AIRCRAFT CABLE SUSPENSION SYSTEM. J. PROVIDE CUSTOM POWER CABLE LENGTH AND ALIGNMENT CLIPS TO YIELD TIGHT VERTICAL INSTALLATION WITHOUT SAGS OR COILS. EXPOSED CABLES AND CLIPS TO BE BLACK WITH DARK PAINTED OVERHEADS AND WHITE WITH LIGHT PAINTED OVERHEADS. K. FINISH CANOPY BY LIGHT FIXTURE OR EXIT SIGN MANUFACTURER. B. C.TYP. D. F. K. G. F. HEIGHT DATUM LINE DEVICE MOUNTING L. SCHEMATIC PENDANT DOWNLIGHT WITH AIRCRAFT CABLE SUSPENSION SYSTEM. STANDARD CYLINDER SHAPE SHOWN FOR REFERENCE, THOUGH FIXTURE MAY BE ORNAMENTAL PROFILE. M. SCHEMATIC PENDANT WIFI, DAS, OR OTHER ANTENNA SYSTEM. EXPOSED CABLES TO BE BLACK WITH DARK PAINTED OVERHEADS AND WHITE WITH LIGHT PAINTED OVERHEADS. PROVIDE COLORED CABLE SLEEVES TO ACHIEVE COLOR MATCH WHEN CABLE COLOR CANNOT BE MANIPULATED. N. RIGID CONDUIT TO SERVE AS PENDANT STEM. PROVIDE FLUSH JUNCTION BOX CLOSURE PLATES WHEN NO MANUFACTURER CANOPY IS AVAILABLE. O. DEVICE, HOUSING, AND FITTINGS TO BE BLACK WITH DARK- PAINTED OVERHEADS AND WHITE WITH LIGHT-PAINTED OVERHEADS. WHEN FACTORY FINISH IS NOT AVAILABLE, PROVIDE PRIMING AND CUSTOM FINISHING TO ACHIEVE. P. SCHEMATIC PENDANT FIRE STROBE AND/OR HORN. FACE OF DEVICE TO ALIGN WITH DATUM LINE. STROBE FEATURE TO EXTEND BELOW DATUM LINE. Q. STEEL ALL-THREAD TO SERVE AS PENDANT STEM. 3/8" MIN. PROVIDE SLEEVE ANCHOR FOR EMBED MOUNTING AT DECK ABOVE. R. RIGID CONDUIT, PARALLEL WITH ALL-THREAD STEM. PROVIDE GALVANIZED CONDUIT ALIGNMENT STRAPS / CLIPS FOR TIGHT INSTALLATION. S. SCHEMATIC PENDANT SECURITY CAMERA. FACE OF DEVICE HOUSING TO ALIGN WITH DATUM LINE. CAMERA DOME TO EXTEND BELOW DATUM LINE. T. SCHEMATIC AV AUDIO, SOUND MASKING, OR SIMILAR SPEAKER WITH AIRCRAFT CABLE SUSPENSION SYSTEM. TRIM CABLE SYSTEM CLEAN AND TIGHT. EXPOSED CABLES TO BE BLACK WITH DARK PAINTED OVERHEADS AND WHITE WITH LIGHT PAINTED OVERHEADS. U. CONTINUOUS GALVANIZED RIGID CONDUIT MOUNTED TIGHT TO UNDERSIDE OF STRUCTURAL DECK ABOVE WITH CONDUIT STRAPS. CONDUIT END TO BE WITHIN 12" OF SPEAKER SUSPENSION SYSTEM. V. UNISTRUT METAL CHANNEL FRAMING. TRAPEZE TIGHT AROUND DUCT OR OTHER OBSTRUCTIONS WHEN PRESENT. 3/8" MIN ALL- THREAD HANGER RODS. PROVIDE SLEEVE ANCHORS FOR EMBED MOUNTING AT DECK ABOVE. W. CONTINUOUS GALVANIZED RIGID CONDUIT TIGHT TO UNDERSIDE OF CHANNEL FRAMING, BENT TO BE PARALLEL WITH ALL-THREAD HANGER. PROVIDE CONDUIT ALIGNMENT STRAPS / CLIPS FOR TIGHT INSTALLATION. X. SCHEMATIC HORIZONTAL OBSTRUCTION. FIREPROOFING SHOWN WHEN OBSTRUCTION IS FIREPROOFED STEEL BEAM. Y. RIGID CONDUIT TO BE VERTICAL AND INSTALLED TIGHT TO OBSTRUCTION FACE. INSTALL 1/2" MAX FROM FIREPROOFING, WHEN PRESENT. CONDUITS TO BE CLUSTERED TIGHT AND PARALLEL WHEN MORE THAN ONE RUN IS PRESENT. Z. CONDULET CONDUIT BODY TO ACHIEVE 90 DEGREE TURN. RIGID CONDUIT AT UNDERSIDE OF OBSTRUCTION TO BE LEVEL AND TIGHT TO FACE OR 1/2" MAX FROM FIREPROOFING, WHEN PRESENT. CONDUITS TO BE CLUSTERED TIGHT AND PARALLEL WHEN MORE THAN ONE RUN IS PRESENT. O. COORDINATE PLACEMENT OF METAL STUD AT PARTITION TYPE TO ACCOMMODATE EXACT LOCATION OF RECEPTACLE CLUSTERS AS DIMENSIONED. FULL METAL STUD TO ISOLATE RECEPTACLE CLUSTERS ON OPPOSITE SIDES OF SAME PARTITION. AT RATED PARTITIONS, PROVIDE INSULATION PUTTY PADS TO MAINTAIN RATING. PROVIDE ADDITIONAL FRAMING AS REQUIRED TO YIELD TIGHT CLUSTER AS SHOWN. 5" 5" AS DIMENSIONED ON PLAN INDICATES FLUSH RECEPTACLE FACE PLATE AND BACK BOX. Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:33 PMTYPICAL DEVICE MOUNTING DIAGRAMS G010 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 3/8" = 1'-0"1 TYPICAL DEVICE MOUNTING DIAGRAMS 3/8" = 1'-0"2 TYP OFFICE-FRONT DEVICE LOCATIONS 3/8" = 1'-0"4 TYP COLUMN DEVICE LOCATIONS 3/8" = 1'-0"3 TYP CORNER DEVICE LOCATIONS 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 1 1/2" = 1'-0"5 TYPICAL OPEN CEILING DEVICE MOUNTINGS 1 1/2" = 1'-0"6 BACK-TO-BACK RECEPTACLE MOUNTING REF: ADA: 404.2.6 / ICC/ANSI: 404.2.5 / TAS: 404.2.624" PREFERRED18" MIN12" MINCBA 48" MIN48" MIN 60" MINDOOR WIDTH DOOR WIDTH DOOR WIDTH WITH PARTITION60" MINWITH PARTITIONS60" MINWITH PARTITIONS60" MIN24" PREFERRED18" MIN24" PREFERRED18" MIN12" MINREF: ADA: 404.2.4 / ICC/ANSI: 404.2.3.1 / TAS: 404.2.4.1 PULL SIDE PUSH SIDE PULL SIDE PUSH SIDE PULL SIDE PUSH SIDE 54" MIN. PROVIDE ADDITIONAL CLEARANCE IF DOOR IS EQUIPPED WITH BOTH A LATCH & CLOSER A.FRONT APPROACH B.HINGE APPROACH C.LATCH SIDE APPROACH *(42" MIN) IF CORRIDOR IS 54" 36" MIN 24" MIN 24" MIN 48" MINIMUM CORRIDOR, IF DOOR HAS BOTH HAS A LATCH & CLOSER 12" MIN 18" MIN CLEAR AT INTERIOR DOOR 24" MIN CLEAR AT EXTERIOR DOOR 48" MIN60" MIN*(54" MIN)60" MIN48" MIN42" MIN54" MINIMUM CORRIDOR, IF DOOR HAS CLOSER 42"48" MINIMUM CORRIDOR, IF DOOR HAS CLOSER 22" MIN NOTE:DASHED RECTANGLES AT DOOR LOCATIONS ILLUSTRATED ON PLAN INDICATE OPEN FLOOR CLEARANCES REQUIRED FOR ACCESSIBILITY. DASHED AREAS INDICATED ARE MINIMUMS. NO CONSTRUCTION, INCLUDING APPLIED WALL BASE OR PROTRUSIONS / ENCROACHMENTS RESULTING FROM "CONSTRUCTION TOLERANCES," WILL BE ACCEPTED WITHIN DASHED REGIONS. 12" MIN 12" MINIMUM, IF DOOR HAS BOTH HAS A LATCH & CLOSER REF: ADA: 304.3 / ICC/ANSI: 304.360" MINSPACE NEEDED TO TURN A WHEELCHAIR 60" MIN 12" MIN LESS THAN 60" 36" MIN 12" MIN 36" MIN60" MIN32" MIN 36" MIN 24" MAXA.MINIMUM TURNING T-SHAPED SPACE FOR 180 DEGREE TURNS B.MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE REF: ADA: 304.3.2, 403.5.1 / ICC/ANSI: 403.5 / TAS: 403.5.1 48" MIN32" MIN 24" MAX36" MIN REF: ADA: 307.2 / ICC/ANSI: 307.2 / TAS: 307.2 4" MAX WHEN HIGHER THAN 27"80" MIN27" MINCANE RANGE WALKING PARALLEL TO WALL WALKING PERPEN- DICULAR TO WALL 12" MAX REF: ADA: 305.7 / ICC/ANSI: 305.7 / TAS: 305.7.1, 305.7.2 30" MIN > 15"> 24"30" MIN FORWARD APPROACH SIDE APPROACH48" MIN12"60" MINREF: ADA: 404.2, 303.3 / ICC/ANSI: 404.2.2, 404.2.9 TAS: 303.3, 404.2.3 2 110" MINHINGED DOOR CHANGE IN LEVEL / DOOR BOTTOM RAIL DOOR PANEL CLEAR 32" MIN SLIDING DOOR CLEAR 32" MIN SMOOTH UNINTERRUPTED SURFACE 1/2" MAX OVERALL HEIGHT 1/4" MAX HEIGHT REF: ADA: 403.5.1 / ICC/ANSI: 403.5.1 / TAS: 403.5.236" MIN.> 48"36" MIN 90 DEGREE TURN 60" MIN36" MIN36" MIN X < 48" 180 DEGREE TURN 48" MIN42" MIN NOTE: DIMENSIONS SHOWN APPLY WHEN X < 48" 42" MIN X < 48" 180 DEGREE TURN REF: ADA: 306.1 / ICC/ANSI: 306.2 17" - 25" MAX 34" MAX27" MIN36" MIN 34" MAX27" MINELEVATION SECTION REF: ADA: 307.3 / ICC/ANSI: 307.3 / TAS: 307.3 A B MAX 1'-0" MAX 1'-0"27"-80"27" MAXX > 12" X > 12"80" MINREF: ADA: 404.2.4.2 / ICC/ANSI: 404.2.3.2 / TAS: 404.2.4.2 A.FRONT APPROACH B.POCKET OR HINGE SIDE APPROACH C.STOP OR LATCH SIDE APPROACH48" MIN42" MIN42" MIN24" MIN 32" MIN.32" MIN.32" MIN. 54" MIN 22" MIN NOTE:DASHED RECTANGLES AT DOOR LOCATIONS ILLUSTRATED ON PLAN INDICATE OPEN FLOOR CLEARANCES REQUIRED FOR ACCESSIBILITY. DASHED AREAS INDICATED ARE MINIMUMS. NO CONSTRUCTION, INCLUDING APPLIED WALL BASE OR PROTRUSIONS / ENCROACHMENTS RESULTING FROM "CONSTRUCTION TOLERANCES," WILL BE ACCEPTED WITHIN DASHED REGIONS. REF: ADA: 306.2, 306.3 / ICC/ANSI: 306.4 / TAS: 306.2, 306.3 ELEVATION PLAN2'-10"2'-3"11" 8"9"2'-1" MAX 6" 2'-6" MIN 2'-1" MAXSheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:34 PMADAAG ACCESSIBILITY COMPONENTS - GENERAL G020 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 3/8" = 1'-0"12 TWO HINGED DOORS IN SERIES 3/8" = 1'-0"9 SWINGING DOOR APPROACH NTS6WHEELCHAIR TURNING RADIUS NTS11MINIMUM CLEAR WIDTH NTS2PROTRUDING OBJECTS NTS7CLEARANCE AT ALCOVES NTS4DOOR OPENING 3/8" = 1'-0" CORRIDOR TURNING SPACE10 NTS3MIN COUNTER CLEARANCES NTS1POST-MOUNTED OBJECTS 3/8" = 1'-0" SLIDING & FOLDING DOOR APPROACH5 NTS8MIN KNEE CLEARANCES 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. DNUPUPDN 30x9030x9030x9024x9030x90 30x90 30x90 30x9030x9030x9030x9030x9030x9030x9030x9030x9030x9024x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x9030x90P47/24 E47/36 EP47/24 E47/36 EP47/24 E47/36 EPPPPI47/24 E47/36 E47/24 E47/36 E47/24 E47/36 EPI47/24 N 47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 E24x6024x6024x6024x6024x6024x60PPPPPP47/24 N 47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 E24x6024x6024x6024x6024x6024x6047/24 N24x6024x6024x6024x6047/24 N47/24 NPPPP47/36 E47/24 E47/36 E47/24 E24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 NPIPPP47/36 E 47/24 EP47/36 E 47/24 EP47/36 E 47/24 EP24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 NPIPPP47/36 E 47/24 EP47/36 E 47/24 EP47/36 E 47/24 EPM231-1422M231-1422M231-1422M231-1422M231-1422M231-1422M 231-1422M231-1422M231-1422M231-1422M231-1422M 231-1422M231-1422M231-1422 M231-1422M231-1422M231-142220 20 25 25 25 25 25 25 25 20 25 20 20 20 20 20 20 20 20 25 20 20 2525 25 25 25 25 2025 25 2025 67/48 N 67/24 N67/30 N42/3D42/3D42/3D42/3D42/3D42/3D36/3D 36/3D P P 67/42 E FSF FLT FS 36/2 D BBF30x6067/48 E67/42 E67/48 N67/36 N67/48 N67/42 E FSFFLT FS36/2D BBF30x6067/48 N67/36 N67/30 E67/42 E FSLT FS 36/2D 30x6067/48 E67/42 E67/48 N36/3D67/30 N67/36 N67/42 ETL FS67/36 E67/36 E FSLT67/24 N 24x6667/24 N67/24 N39/24 N39/24 E39/24 EP P 67/48 E36/2D 67/36 E42/3D 42/3 D 36/3 D 36/3 D 36/3D 36/3D42/3D 42/3D42/3D42/3D42/3D42/3D42/3D42/3D 42/3D 42/3D 36/3D36/3D 36/3D36/3D36/3D 36/3D36/3D 36/3D85/12 N8585/24 N80/48 85/24 N85/12 N FS67/48 E 67/30 NPI39/42 EPIPI 67/24 N67/30 N67/30 N67/48 N 67/48 E67/42 E FSFF L T FS 36/2DBBF30x6067/42 E 67/24 N67/30 N67/30 N67/48 N 67/48 E67/42 E FSFF L T FS 36/2DBBF30x6067/42 E PI67/30 N67/30 N67/48 N 67/48 E67/42 E FSFF L T FS 36/2DBBF30x6067/42 E P IPIPI FS FFL T FS36/2DBBF 30x60 67/24 N67/30 N FS FFL T FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/30 N67/42 E 67/48 N67/42 E67/48 N 67/42 E FS FFL T FS36/2DBBF 30x60 67/24 N67/48 N 67/30 N67/42 E FS FFL T FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/48 N 67/30 N67/42 E FS FFL T FS36/2DBBF 30x60 67/24 N67/48 N 67/30 N67/42 E FS FFL T FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/48 N 67/30 N67/42 E FS FFL T FS36/2DBBF 30x60 67/48 N 67/30 N67/42 E FS FFL T FS36/2DBBF 30x60 67/48 E67/42 E67/48 N 67/30 N85/42 N85/42 N85/48 N85/48 N85/48 N85/42 E FS FFL T FS36/2DBBF 30x60 67/24 N67/30 N FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/30 N67/42 E 67/48 N67/42 E67/48 N L T FS36/2DBBF67/42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/48 N 67/30 N67/42 E FS FFL T FS36/2DBBF 30x60 67/24 N67/30 N67/42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/48 N 67/30 N67/42 E FS FFL T FS36/2DBBF 30x60 67/48 N 67/30 N67/42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/48 N 67/30 N39/42 E39/48 E FS FSLT67/36 N67/48 N FF36/2 D BBF30x6039/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E FS FS FS FS FS FS FS FSFFL T36/2 D BBF30x6067 /2 4 N67/30 N67/42 E FSFFLT36/2 D BBF30x6067 /2 4 N67/48 N67/30 N67/42 E67/48 N67/42 E FSFFLT36/2D BBF30x606 7/24 N 67/48 N67/42 E FSFFLT36/2D BBF30x606 7/24 N67/48 N67/30 N67/42 E FSFFL T36/2D BBF30x6067 /2 4 N67/48 N67/30 N67/42 E FS FF LT 36/2DBBF67/2 4 N 67/48 N67/30 N67/42 E FSFFL T36/2 D BBF30x606 7/24 N 67/48 N67/42 N67/48 N67/30 N FSFFL T FS36/2D BBF30x606 7/24 N67/30 N FSF FLT FS 36/2 D BBF30x6067/24 N67/48 E67/42 E67/30 N67/42 E67/48 N67/42 E FSFFLT FS36/2 D BBF30x6067 /2 4 N67/48 N67/30 N67/42 E FSFF LT FS 36/2 D BBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FS FF36/2DBBF 30x60 67 /2 4 N67/48 N67/30 N67/42 E FSF FLT FS 36/2D BBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2D BBF30x606 7/24 N 67/48 N67/42 N67/48 N67/30 N67/42 E FSFF LT FS 36/2D BBF30x6067/24 N67/48 N67/42 N67/48 E67/42 E67/48 N67/30 NPP67/42 E FS FFL T FS36/2DB B F3 0x 6067/24 N 67/48 N67/30 N67/48 E67/42 E67/42 E FS FFLT FS36/2DBBF 3 0x 6067/24 N 67/48 N67/30 N67/42 E FS FF LT FS 36/2DBBF 3 0x 6067/24 N 67/48 E67/42 E67/48 N67/30 N67/42 E FS FFLT FS36/2DB B F30 x60 67/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSFF 36/2DBBF30x6067/24 N67/48 N67/48 E67/42 E67/48 N 67/42 E FS FFLT FS36/2DB B F30 x60 67/24 N 67/48 N67/30 N67/42 E FS FF LT FS 36/2DBBF 3 0x 6067/24 N 67/48 E67/42 E67/48 N67/30 N67/42 E FS FFLT FS36/2DB B F3 0x 6067/24 N 67/48 N67/30 N67/42 E FS FF LT FS 36/2DB B F30 x60 67/24 N 67/48 E67/42 E67/48 N67/30 N67/42 E FS FFLT FS36/2DBBF 3 0x 6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSLT FS B B F30 x60 67/48 E67/42 E67/48 N67/30 N36/2 D 36/2 D CALCULATION AS PER IBC OCCUPANT LOAD FACTORS / TABLE 1004.5 EGRESS PLAN LEGEND SCOPE OF PROJECT BOUNDARY, WHEN PROJECT IS A PARTIAL FLOOR EXISTING PARTITION TO REMAIN NEW PARTITION EXISTING ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS SCOPE OF WORK DOOR AND FRAME OPENING MAX TRAVEL TO AN EXIT COMMON PATH OF TRAVEL DEAD END (ACTUAL) (COMMON PATH OF TRAVEL) X' - Y" (ACTUAL) (COMMON PATH OF TRAVEL) X' - Y" 2 HR FIRE RATED CONSTRUCTION (Fire Rating = 2) 1 HR FIRE RATED CONSTRUCTION (Fire Rating = 1) 1 HR RATED GLAZED FIRE BARRIER (Fire Rating = 1-GL) 2 HR RATED GLAZED FIRE BARRIER (Fire Rating = 2-GL) 1 HR RATED GLAZED FIRE & SMOKE BARRIER (Fire Rating = 1S-GL) S S S S S LEVEL OF EXIT DISCHARGE EXIT SIGN / DIRECTION OF TRAVEL HORIZONTAL EXIT / EXIT ACCESS TO ENCLOSED STAIR FIRE EXTINGUISHER CABINET75' MAX DISTANCEFEC 2-WAY 2-WAY COMMUNICATION EGRESS UNIT FACTOR CALCULATED EGRESS CAPACITY STAIR DESIGNATION EXIT WIDTH UNIT CAP. PROPOSED LOAD STR DR 100 1000.3" / PERS. 0.2" / PERS. OCC # 42" 33" CLEAR (36" PANEL) STAIR A QUANTITY ON PLAN MAXIMUM CAPACITY SERVED COMMENTS MAXIMUM CAPACITY PER FIXTURE TYPE FIXTURE TYPE CALCULATION AS PER IPC FIXTURE RATIOS / TABLE 403.1 FULL FLOOR, EXISTING AND NEW (WHEN PRESENT) COMBINED - 286 p 100 p N/A LEAST QUANTITY CATEGORY IS THE TOTAL FLOOR PLUMBING FIXTURE CAPACITY PLUMBING FIXTURE CAPACITY WATER CLOSETS LAVATORIES DRINKING FACILITIES SERVICE SINKS WOMEN MEN 4 3 142 p 142 p WOMEN MEN 3 3 2 1 142 p 142 p 286 p UNLIMITED UNISEX 0 2 p UNISEX 0 2 p CODE REQUIRES WATER CLOSET QUANTITIES TO BE SERVE EQUAL NUMBERS OF WOMEN AND MEN. AS SUCH, THE LESSER QUANTITY CAPACITY OF EITHER GENDER IS TO BE THE BASELINE CAPACITY THAT IS MULTIPLIED BY TWO FOR THE FULL GENDERED CAPACITY. THIS QUANTITY REPRESENTS THE GENDERED CAPACITY PLUS UNISEX CAPACITY 286 p CODE REQUIRES LAVATORY QUANTITIES TO BE SERVE EQUAL NUMBERS OF WOMEN AND MEN. AS SUCH, THE LESSER QUANTITY CAPACITY OF EITHER GENDER IS TO BE THE BASELINE CAPACITY THAT IS MULTIPLIED BY TWO FOR THE FULL GENDERED CAPACITY. THIS QUANTITY REPRESENTS THE GENDERED CAPACITY PLUS UNISEX CAPACITY HALF OF DRINKING FACILITIES MUST BE TRADITIONAL WATER FOUNTAIN CONFIGURATION ONE PER FLOOR IS REQUIRED 286 p DESIGN OCCUPANT LOAD OF THE NEW PLAN IS BELOW THE MAXIMUM CAPACITY OF THE EGRESS STAIR AND IS THEREFORE COMPLIANT FULL FLOOR DESIGN OCCUPANT LOAD CALCULATED | COUNTED EGRESS STAIR MAXIMUM OCCUPANT LOAD CAPACITY COMPARISON STATEMENT OCCUPANT LOAD COMPLIANCE TOILET ROOMS MAXIMUM OCCUPANT LOAD CAPACITY -285 p - DESIGN OCCUPANT LOAD OF THE NEW PLAN IS BELOW THE MAXIMUM CAPACITY OF THE TOILET ROOMS AND IS THEREFORE COMPLIANT 286 p*XXX p | XXX p 285 p | 234 p VALUES ARE AS TABULATED ELSEWHERE ON THIS SHEET BOTH THE "CALCULATED" AND THE "COUNTED" DESIGN OCCUPANT LOADS ARE LISTED HERE. THE HIGHER FIGURE IS THE PLAN RESPONSIBILITY TO ACCOMMODATE. COMBINED CAPACITY OF ALL STAIR TOWERS AS IDENTIFIED ON EGRESS PLAN ABOVE. CAPACITY AS IDENTIFIED AT "PLUMBING FIXTURE CAPACITY" TABLE ON THIS SHEET. *OCCUPANT LOAD FOR PLUMBING FIXTURES IS PERMITTED TO EQUAL X/X OF OCCUPANT LOAD DETERMINED FOR EGRESS, PER XXXXXX. [ XXXp x X/X = XXXp ] and [ XXXp x X/X = XXXp ] [ XXX + XXX ] TYPE OF SPACE ARE SEATS COUNTED FOR THIS SPACE NUMBER OF ANTICIPATED USERS COUNTED FROM PLAN BASED ON QUANTITY AND TYPE OF SEATS SHOWN AT PLAN PROJECT SCOPE AREA ENCLOSED OFFICES WORKSTATIONS OR OPEN DESKS ENCLOSED CONFERENCE ROOMS RECEPTION AREA GUEST CHAIRS AND RECEPTIONIST ENCLOSED PHONE ROOMS OPEN WORKPLACE INFORMAL HUDDLE AREAS OPEN WORKPLACE INFORMAL LOUNGE FURNITURE OPEN TEAMING BOOTHS WITH BANQUETTES / BENCHES YES ALL BUT ONE CHAIR IS COUNTED, AS ONE CHAIR IS ASSUMED TO E EVENT SPONSOR COUNTED VIA OPEN DESKS -N/A TEMPORARY USE SPACES FOR OCCUPANTS COUNTED VIA OPEN DESKS 0 p 78 p 40 p 0 p 0 p 0 p 0 p 0 p PROJECT SCOPE AREA DESIGN OCCUPANT LOAD BY CALCULATION 118 p COUNT OF ANTICIPATED USERS COMMENTS EMPLOYEE PANTRY OR EMPLOYEE SOCIAL HUB CAFETERIA / DINING ROOM CONFERENCE CENTER BREAK-OUT AREAS OTHER SEATS NOT ACCOUNTED FOR IN ABOVE YES YES NO NO NO NO NO NO NO NO NO - -N/A TEMPORARY USE SPACES FOR OCCUPANTS COUNTED VIA OPEN DESKS TEMPORARY USE SPACES FOR OCCUPANTS COUNTED VIA OPEN DESKS TEMPORARY USE SPACES FOR OCCUPANTS COUNTED VIA OPEN DESKS TEMPORARY USE SPACES FOR OCCUPANTS COUNTED VIA OPEN DESKS -N/A - TRANSITIONAL USE SPACES FOR OCCUPANTS COUNTED VIA CONFERENCE ROOM SEATS 0 p 0 p 0 p 0 p FUNCTIONS OF SPACE ARE ASSUMED VIA BEST PRACTICE EFFORTS BALANCE OF FLOOR AREA, NOT IN SCOPE DESIGN OCCUPANT LOAD BY CALCULATION 116 p TOTAL FLOOR DESIGN OCCUPANT LOAD BY COUNT OF ANTICIPATED USERS 234 p BALANCE OF FLOOR, NOT IN SCOPE TYPE OF SPACE ARE SEATS COUNTED FOR THIS SPACE NUMBER OF ANTICIPATED USERS COUNTED FROM PLAN COMMENTS ADJACENT TENANT SPACE FULL FURNITURE PLAN NOT AVAILABLE. OCCUPANT LOAD USED HERE IS DERIVED BY LOAD FACTOR CALCULATION. 116 p- TEMPORARY USE SPACES FOR OCCUPANTS COUNTED VIA OPEN DESKS FUNCTION OF SPACE OCCUPANT LOAD FACTOR SQUARE FOOT AREA FROM PLAN GROSS OR NET AS INDICATED MINIMUM OCCUPANCY RESPONSIBILITY PER FUNCTION HATCH IDENTIFIER ON PLAN CALCULATION AS PER IBC OCCUPANT LOAD FACTORS / TABLE 1004.5 PROJECT SCOPE AREA BUSINESS AREAS ASSEMBLY STANDING AREAS ASSEMBLY CLASSROOM CHAIRS AREAS ASSEMBLY CONFERENCE / TABLES AND CHAIRS AREAS STORAGE, MECHANICAL AND ELECTRICAL AREAS COMMERCIAL KITCHENS / DISPLAY COOKING EXERCISE AREAS / GYMS LOCKER ROOMS / SHOWER ROOMS 100 GROSS SF 5 NET SF 7 NET SF 15 NET SF 300 GROSS SF 200 GROSS SF 50 GROSS SF 50 GROSS SF 0 NET SF 7,465 GROSS SF 0 NET SF 1,396 NET SF 212 GROSS SF 0 GROSS SF 0 GROSS SF 0 GROSS SF 75 p 93 p 1 p PROJECT SCOPE AREA DESIGN OCCUPANT LOAD BY CALCULATION 169 p FUNCTION OF SPACE OCCUPANT LOAD FACTOR SQUARE FOOT AREA FROM PLAN GROSS OR NET AS INDICATED MINIMUM OCCUPANCY RESPONSIBILITY PER FUNCTION HATCH IDENTIFIER ON PLAN FUNCTIONS OF SPACE ARE ASSUMED VIA BEST PRACTICE EFFORTS BUSINESS AREAS ASSEMBLY CONFERENCE / TABLES AND CHAIRS AREAS STORAGE, MECHANICAL AND ELECTRICAL AREAS 100 GROSS SF 15 NET SF 300 GROSS SF 11,628 GROSS SF 0 NET SF X,XXX GROSS SF 116 p BALANCE OF FLOOR AREA, NOT IN SCOPE DESIGN OCCUPANT LOAD BY CALCULATION 116 p TOTAL FLOOR DESIGN OCCUPANT LOAD BY CALCULATION 285 p CALCULATED DESIGN OCCUPANCY BALANCE OF FLOOR, NOT IN SCOPE AS PER 2012 INTERNATIONAL BUILDING CODE CODE SECTIONS FOR REFERENCE SECTION 303.1.2 SMALL ASSEMBLY SPACES THE FOLLOWING ROOMS AND SPACES SHALL NOT BE CLASSIFIED AS ASSEMBLY OCCUPANCIES: 1. A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS AND ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PART OF THAT OCCUPANCY. 2. A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES THAT IS LESS THAN 750 SQUARE FEET IN AREA AND ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS GROUP B OCCUPANCY OR AS PART OF THAT OCCUPANCY. SECTION 508 MIXED USE AND OCCUPANCY 508.1 GENERAL EACH PORTION OF A BUILDING SHALL BE INDIVIDUALLY CLASSIFIED IN ACCORDANCE WITH SECTION 302.1. WHERE A BUILDING CONTAINS MORE THAN ONE OCCUPANCY GROUP, THE BUILDING OR PORTION THEREOF SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTION 508.2, 508.3 OR 508.4, OR A COMBINATION OF THESE SECTIONS. 508.2 ACCESSORY OCCUPANCIES ACCESSORY OCCUPANCIES ARE THOSE OCCUPANCIES THAT ARE ANCILLARY TO THE MAIN OCCUPANCY OF THE BUILDING OR PORTION THEREOF. ACCESSORY OCCUPANCIES SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 508.2.1 THROUGH 508.2.4. 508.2.1 OCCUPANCY CLASSIFICATION ACCESSORY OCCUPANCIES SHALL BE INDIVIDUALLY CLASSIFIED IN ACCORDANCE WITH SECTION 302.1. THE REQUIREMENTS OF THIS CODE SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY CLASSIFICATION OF THAT SPACE. 508.2.2 ALLOWABLE BUILDING HEIGHT THE ALLOWABLE HEIGHT AND NUMBER OF STORIES OF THE BUILDING CONTAINING ACCESSORY OCCUPANCIES SHALL BE IN ACCORDANCE WITH SECTION 504 FOR THE MAIN OCCUPANCY OF THE BUILDING. 508.2.3 ALLOWABLE BUILDING AREA THE ALLOWABLE AREA OF THE BUILDING SHALL BE BASED ON THE APPLICABLE PROVISIONS OF SECTION 506 FOR THE MAIN OCCUPANCY OF THE BUILDING. AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE THAN 10 PERCENT OF THE FLOOR AREA OF THE STORY IN WHICH THEY ARE LOCATED AND SHALL NOT EXCEED THE TABULAR VALUES FOR NONSPRINKLERED BUILDINGS IN TABLE 506.2 FOR EACH SUCH ACCESSORY OCCUPANCY. 508.2.4 SEPARATION OF OCCUPANCIES NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES AND THE MAIN OCCUPANCY. 508.3 NONSEPARATED OCCUPANCIES BUILDINGS OR PORTIONS OF BUILDINGS THAT COMPLY WITH THE PROVISIONS OF THIS SECTION SHALL BE CONSIDERED AS NONSEPARATED OCCUPANCIES. 508.3.1 OCCUPANCY CLASSIFICATION NONSEPARATED OCCUPANCIES SHALL BE INDIVIDUALLY CLASSIFIED IN ACCORDANCE WITH SECTION 302.1. THE REQUIREMENTS OF THIS CODE SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY CLASSIFICATION OF THAT SPACE. IN ADDITION, THE MOST RESTRICTIVE PROVISIONS OF CHAPTER 9 THAT APPLY TO THE NONSEPARATED OCCUPANCIES SHALL APPLY TO THE TOTAL NONSEPARATED OCCUPANCY AREA. 508.3.1.1 HIGH-RISE BUILDINGS WHERE NONSEPARATED OCCUPANCIES OCCUR IN A HIGH-RISE BUILDING, THE MOST RESTRICTIVE REQUIREMENTS OF SECTION 403 THAT APPLY TO THE NONSEPARATED OCCUPANCIES SHALL APPLY THROUGHOUT THE HIGH-RISE BUILDING. 508.3.2 ALLOWABLE BUILDING AREA, HEIGHT AND NUMBER OF STORIES THE ALLOWABLE BUILDING AREA, HEIGHT, AND NUMBER OF STORIES OF THE BUILDING OR PORTION THEREOF SHALL BE BASED ON THE MOST RESTRICTIVE ALLOWANCES FOR THE OCCUPANCY GROUPS UNDER CONSIDERATION FOR THE TYPE OF CONSTRUCTION OF THE BUILDING IN ACCORDANCE WITH SECTION 503.1. 508.3.3 SEPARATION NO SEPARATION IS REQUIRED BETWEEN NONSEPARATED OCCUPANCIES. AS RELEVANT FOR THE CITY OF INDIANAPOLIS, INDIANA APPLICABLE CODES APPLICABLE CODES: 2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE) 2014 INDIANA MECHANICAL CODE 2009 INDIANA ELECTRICAL CODE 2014 INDIANA FIRE CODE 2012 INDIANA PLUMBING CODE EXISTING BASE BUILDING INFORMATION: EXISTING TYPE OF CONSTRUCTION:TYPE IB NUMBER OF EXISTING STORIES:5 • PROJECT SCOPE DOES NOT CHANGE BASE BUILDING CONSTRUCTION CLASSIFICATION • PROJECT SCOPE DOES NOT CHANGE BASE BUILDING AREA • PROJECT SCOPE DOES NOT CHANGE BASE BUILDING HEIGHT • PROJECT SCOPE DOES NOT INCLUDE ANY ALTERATION TO EXTERIOR BUILDING SKIN • PROJECT SCOPE DOES NOT INCLUDE ANY ALTERATION TO EXISTING INTERIOR EGRESS STAIR TOWERS FIRE RESISTANCE RATING REQUIREMENTS -AS PER TABLE 601: PRIMARY STRUCTURAL FRAME: 2 HOURS EXTERIOR BEARING WALL:2 HOURS INTERIOR BEARING WALL:2 HOURS INTERIOR NONBEARING PARTITION:0 HOURS FLOOR CONSTRUCTION:2 HOURS ROOF CONSTRUCTION:1 HOUR SPRINKLER DECLARATION:EXISTING BUILDING IS FULLY SPRINKLERED MEANS OF EGRESS COMPONENTS THE EGRESS PLAN ON THIS SHEET ILLUSTRATES THAT THE NEW PLAN CONFIGURATION DOES NOT EXCEED EXISTING EGRESS STAIR CAPACITY. PLEASE SEE "OCCUPANT LOAD COMPLIANCE" CHART AT THIS SHEET. THE PLAN COMPLIES WITH THE FOLLOWING CONFIGURATION AND DIMENSIONAL LIMITS: OVERALL LENGTH OF TRAVEL | TABLE 1017.2 =300 FEET, MAX COMMON PATH OF TRAVEL | TABLE 1006.2.1 = 100 FEET, MAX DEAD END CORRIDOR LENGTH | TABLE 1020.4 =50 FEET, MAX CORRIDOR AND PATHWAY WIDTH | TABLE 1020.2 =36 INCHES WIDE, MIN when less than 50 people CORRIDOR AND PATHWAY WIDTH | TABLE 1020.2 =44 INCHES WIDE, MIN when 50 people or greater STAIR CAPACITY FACTOR | SECTION 1005.3.1 =0.20 INCHES PER PERSON, sprinklered building DOOR CAPACITY FACTOR | SECTION 1005.3.2 =0.15 INCHES PER PERSON, sprinklered building DOOR SWINGS IN DIRECTION OF EGRESS =50 PEOPLE or greater TWO MEANS OF EGRESS PROVIDED =50 PEOPLE or greater SLIDING DOORS PROVIDED =10 PEOPLE or fewer MEDIUM CONF. 305 FOCUS 324 STORAGE 323 SMALL CONF. 322 SMALL CONF. 321 WELLNESS 306 LARGE CONF. 320 MEDIUM CONF. 122 BREAK ROOM 302 74' COMMON PATH OF TRAVEL94' COMMON PATH OF TRAVELFE FE FE FE IDF 304 138'-4"5 7 '-3 "NSheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:38 PMLIFE SAFETY PLAN AND CODE OUTLINE G101 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. DNUPDNUP MEDIUM CONF. 305 STORAGE 323 SMALL CONF. 322 SMALL CONF. 321 OPEN OFFICE MEDIUM CONF. 122 OPEN OFFICE LARGE CONF. 320 BREAK ROOM 302 IDF 304 OPEN OFFICE D104 D102 D103 5'-2"9'-3"4'-11" 4'-11"1'-0" D101 D105 D106 1. SEE SHEET G001 FOR GRAPHIC LEGEND INFORMATION. 2. SEE SHEET G002 FOR ADDITIONAL PLAN SPECIFIC GENERAL NOTES. 3. SEE SHEET G010 FOR WALL AND CEILING DEVICE ALIGNMENT DIAGRAMS. PROVIDE ADDITIONAL CONCEALED FRAMING FOR EXACT PLACEMENT. 4. SEE SHEET G002 FOR OPEN CEILING ORGANIZATION GENERAL NOTES AND G011 FOR OPEN CEILING ORGANIZATION GUIDE. GENERAL PLAN NOTES FOCUS 324 STORAGE 323 LARGE CONF. 320 SMALL CONF. 322 SMALL CONF. 321 MEDIUM CONF. 305 OPEN OFFICE OPEN OFFICE 0V3A 1A3A1A3A1A3A1A3A BREAK ROOM 302 MEDIUM CONF. 122 1/A801 0V3A0V3A 0V3A 306 B 6 324 B 1 323 A 7 6'-0"IDF 304 OPEN OFFICE 0V3AC101 C101 C105 C107 WELLNESS 306 5'-0"3'-1"3'-0"5'-3" 319 B 7 0V3A7'-6"1A3AC109 C109 C109 C109 C109 320 B 1 325 C EX 122 C EX 321 C EX 322 C EX 305 C EX 0F3 2A A612 SPECIALTY EQUIPMENT REF UNDER COUNTER REFRIGERATOR REUSE EXISTING DEMOLITION LEGEND EXISTING CONSTRUCTION PARTITION, DOOR, GLAZING AND FRAMES TO REMAIN EXISTING PARTITION, DOOR, GLAZING AND FRAMES TO BE REMOVED AREA NOT IN CONTRACT FLOOR PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION, PARTITION TYPE AS INDICATED ON PLAN EXISTING ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS SCOPE OF WORK NEW CASEWORK/ MILLWORK, COORDINATE ALSO WITH POWER AND DATA PLAN NEW DOOR AND FRAME OPENING NSheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No.Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:18 PMDEMOLITION PLAN AND CONSTRUCTION PLAN- LEVEL 3 A101 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 KEYNOTE LEGEND C101 NEW DEMISING WALL. PROVIDE PAINT AND RUBBER BASE TO MATCH EXISTING. C105 WELLNESS ROOM MILLWORK: PLASTIC LAMINATE LOWER CABINET FRONTS, PLASTIC LAMINATE COUNTERTOP, (1) PLASTIC LAMINATE UNDERCOUNTER REFRIGERATOR NICHE. C107 ALL APPLIANCES WILL BE PROVIDED BY VERIZON AND INSTALLED BY THE GC. C109 REFER TO AV DRAWINGS FOR WALL BLOCKING INFORMATION. D101 EXISTING PARTITION TO BE REMOVED COMPLETE. PROTECT ADJACENT CONSTRUCTION TO REMAIN. D102 REMOVE EXISTING DOOR IN PREPARATION FOR NEW FRAMELESSS OPENING. PROVIDE ADDITIONAL CONCEALED METAL STUD FRAMING TO FORM ROUGH OPENING WITH HEADER IN PREPARATION FOR FINAL GWB FINISH AT ALL FACES. HEADER TO ALIGN WITH SIMILAR HEADERS AT SAME ROOM OR AREA. D103 SELECTIVELY REMOVE EXISTING PARTITION IN PREPARATION FOR INSTALLATION OF DOOR AND METAL DOOR FRAME ASSEMBLY. PROVIDE ADDITIONAL CONCEALED METAL STUD FRAMING TO FORM ROUGH OPENING WITH HEADER IN PREPARATION FOR FINAL METAL DOOR FRAME INSTALLATION. SELECTIVELY REPAIR, INCLUDING SKIM COATING AS NECESSARY, ADJACENT GWB PARTITION SMOOTH TO ELIMINATE DEMOLITION AND INSTALLATION PROCESS. D104 EXISTING DOOR, FRAME AND HARDWARE ASSEMBLY TO BE REMOVED COMPLETE. RETURN ALL DOOR HARDWARE TO TENANT FOR ATTIC STOCK. RETURN DOOR LEAF / LEAVES AND FRAME TO TENANT FOR ATTIC STOCK AT OWNER’S REQUEST. INVENTORY SIZES AND QUANTITIES, LABEL COMPONENTS CLEARLY, PROTECT EDGES AND FACES, AND TEMPORARILY STORE. D105 REMOVE CARPET IN THIS AREA.  RE: CONSTRUCTION PLAN FOR LIMITS OF WELLNESS ROOM AND NEW FLOORING. D106 EXISTING FLOORING TO REMAIN. NEW FLOORING TO BE PLACED OVER EXISTING FLOORING. 1/8" = 1'-0"1 DEMOLITION PLAN - LEVEL 3 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 1/8" = 1'-0"2 CONSTRUCTION PLAN - LEVEL 3 DNUP DNUP 1. SEE SHEET G001 FOR GRAPHIC LEGEND INFORMATION. 2. SEE SHEET G002 FOR ADDITIONAL PLAN SPECIFIC GENERAL NOTES. 3. SEE SHEET G010 FOR WALL AND CEILING DEVICE ALIGNMENT DIAGRAMS. PROVIDE ADDITIONAL CONCEALED FRAMING FOR EXACT PLACEMENT. 4. SEE SHEET G002 FOR OPEN CEILING ORGANIZATION GENERAL NOTES AND G011 FOR OPEN CEILING ORGANIZATION GUIDE. GENERAL PLAN NOTES LARGE CONF. 320 MEDIUM CONF. 122 SMALL CONF. 321 SMALL CONF. 322 STORAGE 323 FOCUS 324 MEDIUM CONF. 305 BREAK ROOM 302 A A R102 R101 R101 R102 A A A A A A A LARGE CONF. 320 MEDIUM CONF. 122 SMALL CONF. 321 SMALL CONF. 322 STORAGE 323 FOCUS 324 MEDIUM CONF. 305 BREAK ROOM 302 R101 R101 2' x 2' GRID AND TILE SYSTEM - EXISTING TO REMAIN MATERIALS FINISHED CEILING HEIGHT, AFF9' -0" ANNOTATIONS REFLECTED CEILING PLAN LEGEND LIGHT FIXTURES 2' x 4' RECESSED LED DIRECT/INDIRECT LIGHT FIXTURE -REFER TO ELECTRICAL DRAWINGS FOR SPECIFICATION EXISTING ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS SCOPE OF WORK DEMOLITION LEGEND EXISTING CONSTRUCTION PARTITION, DOOR, GLAZING AND FRAMES TO REMAIN EXISTING PARTITION, DOOR, GLAZING AND FRAMES TO BE REMOVED AREA NOT IN CONTRACT NSheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:20 PMDEMO REFLECTED CEILING PLAN AND REFLECTED CEILING PLAN - LEVEL 3 A201 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 KEYNOTE LEGEND R101 THERE ARE NO NEW LIGHT FIXTURES. EXISTING FIXTURES TO BE RELOCATED AS NEEDED. R102 EXISTING CEILING TO REMIN HEIGHT IS 9'-0" AFF U.N.O. 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 1/8" = 1'-0" REFLECTED CEILING PLAN - LEVEL 32 1/8" = 1'-0" DEMO REFLECTED CEILING PLAN - LEVEL 31 DNUP P47/24 E47/36 EP47/24 E47/36 EP47/24 E47/36 EPPPPI47/24 E47/36 E47/24 E47/36 E47/24 E47/36 EPI47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 E24x6024x6024x6024x6024x6024x60PPPPPP47/24 N 47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 E24x6024x6024x6024x6024x6024x6047/24 N24x6024x6024x6024x6047/24 N47/24 NPPPP47/36 E47/24 E47/36 E47/24 E24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N 47/24 N47/24 N47/24 NPIPPP47/36 E 47/24 EP47/36 E 47/24 EP47/36 E47/24 EP24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N 47/24 N47/24 N47/24 NPIPPP47/36 E 47/24 EP47/36 E 47/24 EP47/36 E47/24 EP20 20 25 25 25 25 25 25 25 20 25 20 20 20 20 20 20 20 20 25 20 20 2525 25 25 25 25 2025 25 2025 67/48 N 67/24 N67/30 N42/3D42/3D42/3D42/3D42/3D42/3D36/3D 36/3DPP67/42 E FSFFLT FS 36/2 D BBF30x6067/48 E67/42 E67/48 N67/36 N67/48 N67/42 E FSFFLT FS36/2 D BBF30x6067/48 N67/36 N67/30 E67/42 E FSLT FS 36/2 D 30x6067/48 E67/42 E67/48 N36/3D67/30 N67/36 N67/42 ETL FS67/36 E67/36 E FSLT67/24 N 24x6667/24 N67/24 N39/24 N39/24 E39/24 EP P 67/48 E36/2 D 67/36 E42/3D 42/3 D 36/3 D 3 6/3 D 36/3D 36/3D42/3D 42/3D42/3D42/3D42/3D42/3D42/3D42/3D 42/3D 42/3D 36/3D36/3D 36/3D36/3D36/3D36/3D36/3D36/3D85/12 N85/24 N80/48 85/24 N85/ 12 N FS67/ 48 E 67/30 NPI39/42 EPIPI 67/24 N67/30 N67/ 30 N67/ 48 N 67/48 E67/42 E FSFF L T FS 36/2DBBF30x6067/ 42 E 67/24 N67/30 N67/ 30 N67/ 48 N 67/48 E67/42 E FSFF L T FS 36/2DBBF30x6067/ 42 E PI67/30 N67/ 30 N67/ 48 N 67/48 E67/42 E FSFF L T FS 36/2DBBF30x6067/ 42 E PIPIPI FS FFLT FS36/2DBBF 30x60 67/24 N67/30 N FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/30 N67/ 42 E 67/ 48 N67/ 42 E67/ 48 N 67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/48 E67/42 E67/ 48 N 67/30 N85/42 N85/42 N85/48 N85/48 N85/48 N85/42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/30 N FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/30 N67/ 42 E 67/ 48 N67/ 42 E67/ 48 N LT FS36/2DBBF67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/ 48 N 67/30 N67/ 42 E FS FFLT FS36/2DBBF 30x60 67/24 N67/48 E67/42 E67/ 48 N 67/30 N39/42 E39/48 E FS FSLT67/36 N67/48 N FF36/2 D BBF30x6039/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E FS FS FS FS FS FS FS FSFFLT36/2 D BBF30x6067/24 N67/30 N67/42 E FSFFLT36/2 D BBF30x6067/24 N67/48 N67/30 N67/42 E67/48 N67/42 E FSFFLT36/2 D BBF30x6067/24 N 67/48 N67/42 E FSFFLT36/2 D BBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT36/2 D BBF30x6067/24 N67/48 N67/30 N67/42 E FS FF LT 36/2DB B F67/24 N 67/48 N67/30 N67/42 E FSFFLT36/2 D BBF30x6067/24 N 67/48 N67/42 N67/48 N67/30 N FSFFLT FS36/2 D BBF30x6067/24 N67/30 N FSFFLT FS 36/2 D BBF30x6067/24 N67/48 E67/42 E67/30 N67/42 E67/48 N67/42 E FSFFLT FS36/2 D BBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS 36/2 D BBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FS FF36/2DB B F 30x60 67/24 N67/48 N67/30 N67/42 E FSFFLT FS 36/2 D BBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2 D BBF30x6067/24 N 67/48 N67/42 N67/48 N67/30 N67/42 E FSFFLT FS 36/2 D BBF30x6067/24 N67/48 N67/42 N67/48 E67/42 E67/48 N67/30 NPP67/42 E FS FFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N67/48 E67/42 E67/42 E FS FFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N67/42 E FS F F LT FS 36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FS FFLT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSFF 36/2DBBF30x6067/24 N67/48 N67/48 E67/42 E67/48 N 67/42 E FS FFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N67/42 E FS FF LT FS 36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FS FFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N67/42 E FS F F LT FS 36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FS FFLT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSLT FS BBF30x6067/48 E67/42 E67/48 N67/30 N36/2 D 36/2 D CR D RRRR RR RRRR FB (F)C FB (F)C WBB WBB WBBWBBWBBWBBWBBWBB RR CR WBBWBBDNUP LARGE CONF. 320 MEDIUM CONF. 122 BREAK ROOM 302 MEDIUM CONF. 305 FOCUS 324 STORAGE 323 SMALL CONF. 322 SMALL CONF. 321 OPEN OFFICE OPEN OFFICE OPEN OFFICE IDF 304 WELLNESS 306 103 104 109 108 107 106 110 111 112 113 117 116 115 114 118 119 120 123 124 125 126 127 128 134 133 132 131 130 129 138 139 137 136 135 142 152 151 150 149 148 147 146 145 144 143 172 171 170 169 168 167 166 161 160 155 156 157 158 159 162 165 164 163 178 177 176 175 174 173 181 182 179 180 P101 P101 P101 137A 140 141 105 121 1. SEE SHEET G001 FOR GRAPHIC LEGEND INFORMATION. 2. SEE SHEET G002 FOR ADDITIONAL PLAN SPECIFIC GENERAL NOTES. 3. SEE SHEET G010 FOR WALL AND CEILING DEVICE ALIGNMENT DIAGRAMS. PROVIDE ADDITIONAL CONCEALED FRAMING FOR EXACT PLACEMENT. 4. SEE SHEET G002 FOR OPEN CEILING ORGANIZATION GENERAL NOTES AND G011 FOR OPEN CEILING ORGANIZATION GUIDE. GENERAL PLAN NOTES MEDIUM CONF. 305 OPEN OFFICE FOCUS 324 STORAGE 323 SMALL CONF. 322 SMALL CONF. 321 OPEN OFFICE MEDIUM CONF. 122 LARGE CONF. 320 OPEN OFFICE BREAK ROOM 302 IDF 304 WELLNESS 306 LVT 1 LVT 1 CPT 1 PT 2 PT2PT 3 PT2PT2PT2F103 F103 F103 PT 2 PT 1 PT 1 PT 1 PT 1 WB 2 WB 1 WB 1 WB 1 PT 1 WB 1 PT 1 WB 1 WB 1 PT 1 WB 1 PT 1 WB 1 PT 1 WB 1 PT 1 WB 1 PT 3 F104 *C1 FINISH TYPES LEGEND A. NEW WALLS TO BE PT-1,U.N.O. ACCENT PAINT PT-2 TO BE FULL WALL AT PARTITION BEHIND DOOR WHEN DOOR IS IN OPEN POSITION, CORNER-TO-CORNER. B. WHEN ACCENT PAINT IS INSTALLED, PROVIDE COORDINATING COLOR ACCENT WALL BASE. C. PROVIDE NEW WALL BASE AT NEW PARTITIONS. MATCH EXISTING U.N.O. CARPET CARPET TILE MFR: SHAW CONTRACT STYLE: BASALT II TILES COLOR: TRAIL 98505 SIZE: 9" x 36" INSTALLATION: ASHLAR NOTE: PROVIDE 5% ADDITIONAL ATTIC STOCK CONTACT: CARI JOHNSON CARIJOHNSON@SHAWCONTRACT.COM CPT 1 LUXURY VINYL TILE MFR: SHAW CONTRACT STYLE: RESIDE 12 MIL COLOR: INHABIT 94155 SIZE: 6" X 47" INSTALLATION: ASHLAR LOCATION: PANTRY AND WELLNESS NOTE: PROVIDE 5% ADDITIONAL ATTIC STOCK CONTACT:CARI JOHNSON CARI.JOHNSON@SHAWCONTRACT.COM LVT 1 LUXURY VINYL TILE FIELD PAINT MFR: SHERWIN WILLIAMS COLOR: MATCH EXISTING FIELD PAINT COLOR FINISH: MATCH EXISTING FILED PAINT FINISH NOTE: PROVIDE 5% ADDITIONAL ATTIC STOCK ACCENT PAINT MFR: SHERWIN WILLIAMS COLOR: AGREEABLE GRAY, SW 7029 FINISH: EGGSHELL NOTE: PROVIDE 5% ADDITIONAL ATTIC STOCK LOCATION: ACCENT PAINT AT TV WALLS ACCENT PAINT MFR: SHERWIN WILLIAMS COLOR: JUBILEE. SW 6248 FINISH: EGGSHELL NOTE: PROVIDE 5% ADDITIONAL ATTIC STOCK LOCATION: WELLNESS ROOM ACCENT PAINT AND BREAK ROOM PAINT PT 1 PAINT PT 2 PT 3 PLASTIC LAMINATE MFR: FORMICA STYLE: THRUCOLOR COLOR: MOUSE 928 PLASTIC LAMINATE MFR: FORMICA STYLE: THRUCOLOR COLOR: PALOMA POLAR 6698 PL 1 MILLWORK FINISHES PL 2 RUBBER BASE MATCH EXISTING RUBBER BASE MFR: JOHNSONITE STYLE: COVE COLOR: SNOWBOUND NOTE: PROVIDE 5% ADDITIONAL ATTIC STOCK WB 1 WALL BASE WB 2 INDICATES FLUSH FLOOR BOX INDICATES TYPE AS OUTLINED BELOW "(F)" WHEN PRESENT INDICATES FLOOR BOX IS SERVING FURNITURE AND IS TO BE COORDINATED WITH SPECIFIC FURNITURE REQUIREMENTS FOR EXACT PLACEMENT. TYPE A: TYPE B: TYPE C: TYPE D:AV FB AV (F)ADUPLEX DEDICATED DUPLEX POWER / DATA RACEWAY TELE / DATA ROOM SCHEDULER SECURITY CARD READER D POWER AND DATA PLAN LEGEND WALL MOUNTED DEVICES INDICATES RECESSED COLLECTOR WALL BOX FOR AV INSTALLATION INDICATES TYPE AS OUTLINED BELOW TYPE A: TYPE B: TYPE C:AV AWB RR CR AV RECESSED WALL BOX FLUSH BOX RECESSED AT FLOOR NSheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:23 PMPOWER & DATA PLAN AND FINISH PLAN - LEVEL 3 A301 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 KEYNOTE LEGEND *C1 CONSTRUCTION PLAN KEY NOTES F103 ADD ALT: PAINT ALL WALLS WITHIN THE SPACE. F104 MATCH BASE BUILDING FLOOR AND WALL FINISHES IN ALCOVE. P101 BASIS OF DESIGN: LEGRAND CONNECTRAC, FLEX SYSTEM FOR 0 TO 6 CABLES, COLOR DG. 1/8" = 1'-0"2 POWER & DATA PLAN - LEVEL 3 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 1/8" = 1'-0" FINISH PLAN - LEVEL 31 DNUP WELLNESS 306 MEDIUM CONF. 305 FOCUS 324 STORAGE 323 SMALL CONF. 322 SMALL CONF. 321 BREAK ROOM 302 LARGE CONF. 320 MEDIUM CONF. 122 IDF 304 ROOM IDEN TYPE G0 WELLNESS ROOM 306 SUPPORT RM IDEN TYPE J0 IDF 304 ROOM IDEN TYPE G0 BREAKROOM 302 ROOM IDEN TYPE G0 MEDIUM CONFERENCE 305 ROOM IDEN TYPE G0 FOCUS 324 ROOM IDEN TYPE G0 STORAGE 323 ROOM IDEN TYPE G0 SMALL CONFERENCE 322 ROOM IDEN TYPE G0 SMALL CONFERENCE 321 ROOM IDEN TYPE G0 MEDIUM CONFERENCE 122 ROOM IDEN TYPE G0 LARGE CONFERENCE 320 NSheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:24 PMSIGNAGE PLAN - LEVEL 3 A501 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 12" = 1'-0"2 ROOM IDENTIFICATION 12" = 1'-0"1 SUPPORT ROOM ID -SIGN TYPE J.0 1/8" = 1'-0"3 SIGNAGE PLAN - LEVEL 3 1. REFER TO INDICATED DRAWINGS FOR HEAD DETAILS; HEAD CONDITION AS APPLICABLE TO SUPPORT CONDITION. 2. PROVIDE TYPE 'X' GWB AT ALL SMOKE PARTITIONS. 3. SMOKE BARRIERS SHALL RESIST THE PASSAGE OF AIR AT THE RATE OF NOT MORE THAN 5.0 CFM/SF AT BOTH AMBIENT TEMPERATURES & 400 DEG F AT A PRESSURE DIFFERENTIAL OF 0.30" WATER COLUMN. 4. MOISTURE RESISTANT, PAPERLESS, COATED FIBERGLASS MAT WATER RESISTANT GYPSUM WALL BOARD TO BE UTILIZED ON THE OUTER LAYER OF ALL PARTITIONS THAT ARE SCHEDULED TO RECEIVE CERAMIC TILE, PORCELAIN TILE, STONE TILE OR ANY MATERIAL THAT IS SECURE WITH ADHESIVES OR THIN-SET MORTARS. 5. PROVIDE 1/2" CEMENT BOARD AT ALL SHOWER AND TUB LOCATIONS. EXTEND A MINIMUM OF 12 INCHES BEYOND WET AREA AS DEFINED BY SHOWER GLASS, CURTAIN, OR TUB EDGE. 6. AT LARGE FORMAT TILE WITH ANY EDGE GREATER THAN 16", PROVIDE 1/2" CEMENT BACKER BOARD WITH METAL STUDS 33 MIL (20 GA STRUCTURAL) MIN, BRACED AT 48" OC VERTICALLY AND A MAX DEFLECTION OF L/360 OR 1/2" MAX, WHICHEVER IS LESS. 7. MOISTURE RESISTANT GWB TO BE USED AT ALL STAIR SHAFTS, ELEVATOR SHAFTS, HVAC SHAFTS, PLUMBING CHASE, EXTERIOR WALLS, JANITOR CLOSETS, MECHANICAL ROOM INCLUDING BULKHEADS, AND OTHER AREAS WERE MOISTURE COULD OCCUR AND AS SPECIFICALLY SCHEDULED AND/OR NOTED. 8. THE TOP/BOTTOM OF WALL DETAILS ARE BASED ON UL ASSEMBLIES OF TYPICAL CONDITIONS FOR FIRE-RESISTIVE JOINT SYSTEMS. THEY DO NOT DEPICT ALL CONDITIONS OR SYSTEMS THAT MAY OCCUR ON THE PROJECT. PROVIDE EQUIVALENT UL ASSEMBLIES OR AN ENGINEERING JUDGEMENT (EJ) FOR ATYPICAL CONDITIONS AND CONDITIONS NOT DEPICTED IN DETAILS. 9. ALL BRACING AND UNBRACED LENGTHS TO BE DESIGNED AND BASED ON SSMA (STEEL STUD MANUFACTURERS ASSOCIATION) PRODUCT TECHNICAL GUIDE [www.ssma.com]. 10. PROVIDE THE APPROPRIATE HEAD CONNECTION DETAIL BASED ON FIRE RATING AND ON CONNECTION CONDITION AT DECK OR BEAM. GENERAL NOTES FOR INTERIOR PARTITIONS BOTTOM OF STRUCTURE FIRE RATING TAG:RATING:UL DESIGN: 0A NON RATED 1A 1 HR U419, U465 SILL CEILING HEAD PARTITION WIDTH LEGEND WIDTH TAG STUD WIDTH OVERALL WIDTH 2 2 1/2"3 3/4" 3 3 5/8"4 7/8" 4 4"5 1/4" 6 6"7 1/4" OVERALL WIDTH MTL STUDS SPACED @ 16" OC, UON PROVIDE TRACK ANCHORAGE AS REQUIRED TO MEET LOADS AND CRITERIA FOR EACH SPECIFIC CONDITION. AT A MINIMUM USE 1/8" PAF AT 1-1/4" MIN EMBEDMENT, WITHIN 2" OF ENDS AND MATCHING STUD SPACING OC MAX MTL BOTTOM RUNNER TRACK CONT ACOUSTICAL SEALANT, BOTH SIDES OF PTN AT RATED PARTITIONS AND AT NON-RATED PARTITIONS. RATED ASSEMBLY TO BE BASED ON UL BW-S-0013 -JOINT SYSTEMS CONCRETE FLOOR SLAB, UON TYPE 0A: 5/8" GWB, (1) LAYER EACH SIDE TYPE 1A: 5/8" TYPE 'X' GWB, (1) LAYER EACH SIDE • PROVIDE MIL THICKNESS AS REQUIRED TO MEET LIMITING HEIGHT, LOADING AND DEFLECTION CRITERIA SEE HEAD DETAILS ON SHEET A611 PLAN SAFB PER MODIFIER "A" SUSPENDED CEILING WHERE OCCURS 1/2"APPROXIMATE STC RANGE: 36-40 WITHOUT SAFB 41-45 W/ SAFB PER MODIFIER "A" • DEFLECTION TO BE BASED ON L/240 UNLESS OTHERWISE NOTED. • FOR TILE, STONE, ELEVATOR WALL, ETC., SEE SPECIFICATION FOR DEFLECTION REQUIREMENTS. WALL / BARRIER / PARTITION FIRE/SMOKE RESISTANCE RATING PARTITION TYPE TAG MTL STUD WIDTH TAG OPTIONAL MODIFIER TAGS 2 S B 3 REFER TO PARTITION TYPE DETAIL INDICATED BY TAG. FOR EXAMPLE: TAG "A" = SEE "TYPE A" DETAIL. INDICATES THE MTL STUD NOM WIDTH, REFER TO "MTL STUD WIDTH LEGEND" BELOW, UON ON PARTITION TYPE DETAIL. REFER TO THE "FIRE/SMOKE RESISTANCE RATING LEGEND" BELOW FOR THE CLASSIFICATION. REFER TO THE "MODIFIER LEGEND" BELOW; NOTES APPLY TO THE FULL EXTENT OF EACH PARTITION WHERE SO TAGGED. MODIFIER LEGEND THE FOLLOWING NOTES APPLY TO THE FULL EXTENT OF EACH PARTITION, WHERE "MODIFIER" CHARACTER(S) ARE SHOWN ON THE TAG: TAG DESCRIPTION A PROVIDE SAFB: 2" THK AT 2-1/2" STUD; 3" THK AT 3-5/8", 4", 5" AND 6" STUDS, UON. B PROVIDE IMPACT/ABUSE RESISTANT GWB COMPLYING WITH HARD BODY IMPACT CLASSIFICATION LEVEL 3 IN LIEU OF INNER LAYER OF GWB ON OUTER SIDE OF STAIR OR ELEVATOR ENCLOSURE OR 2 LAYERS OF IMPACT RESISTANT BOARD, EACH OF WHICH COMPLIES WITH HARD BODY IMPACT CLASSIFICATION LEVEL 2. G GROUT ALL CMU VOIDS SOLID FIRE/SMOKE RESISTANCE RATING LEGEND THE COMPLETE ASSEMBLY OF EACH PARTITION WITH A FIRE/SMOKE RATING TAG SHALL COMPLY WITH ALL REQUIREMENTS OF THE FIRE-RESISTANCE/SMOKE BARRIER RATING CLASSIFICATION: MTL STUD WIDTH LEGEND TAG STUD WIDTH 0 7/8" FURRING CHANNEL 1 1-5/8" 2 2-1/2" 3 3-5/8" LEGEND FOR INTERIOR GWB & CMU PARTITIONS A B TAG FIRE RATING CLASSIFICATION 0 NON-RATED 1 1 HOUR FIRE RESISTANCE 2 2 HOUR FIRE RESISTANCE 3 3 HOUR FIRE RESISTANCE 4 4 HOUR FIRE RESISTANCE TAG FIRE/SMOKE RATING CLASSIFICATION 0S NON-RATED SMOKE PARTITION 1S 1 HOUR FIRE-RESISTANT SMOKE BARRIER 2S 2 HOUR FIRE-RESISTANT SMOKE BARRIER 3S 3 HOUR FIRE-RESISTANT SMOKE BARRIER 4S 4 HOUR FIRE-RESISTANT SMOKE BARRIER TAG MASONRY WIDTH 04 3-5/8" 06 5-5/8" 08 7-5/8" 10 9-5/8" 12 11-5/8" TAG STUD WIDTH 4 4" 5 5" 6 6" MASONRY WIDTH LEGEND LIMITING HEIGHTS TABLE TABLE BASED ON STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) GUIDE FOR COMPOSITE INTERIOR PARTITION CONSTRUCTION WITH SINGLE LAYER OF 5/8" GWB AT BOTH SIDES OF PARTITION ASSEMBLY FOR FULL HEIGHT. TABLE BASED ON C-STUD COLD-FORMED STEEL FRAMING WITH 1-1/4" FLANGE WIDTH. WHEN STEEL STUD DIMENSIONS, SPACINGS, GAUGES, DEFLECTION CRITERIA, OR GWB COVERAGE DO NOT MATCH THIS LIMITING HEIGHTS TABLE, ENGINEER SUCH PARTITIONS SEPARATELY. 25 GAUGE (18 MILS) 16" O.C.24" O.C. 10'-1"8'-9" 20 GAUGE (30 MILS) 16" O.C.24" O.C. 10'-9"9'-4"1-5/8" WEB DEPTH LIMITING HEIGHT CRITERIA = L/240* DEFLECTION at 5 PSF** 12'-10"11'-3"14'-5"12'-7"2-1/2" 15'-2"13'-2"16'-7"14'-6"3-5/8" 15'-11"13'-8"17'-8"15'-5"4" 20'-1"16'-4"24'-7"21'-6"6" *NOTE:WHEN INTERIOR PARTITION FINISH IS STONE, TILE, OR OTHER RIGID OR BRITTLE FINISH FACE MATERIAL, DEFLECTION CRITERIA TO BE L/360, FOR WHICH THIS LIMITING HEIGHTS TABLE IS NOT APPLICABLE. ENGINEER SUCH PARTITIONS SEPARATELY. **NOTE:WHERE PARTITION PRESSURE CRITERIA IS TO EXCEED 5 PSF PER SPECIFICATIONS, SUCH AS ATRIUM WALLS, STAIR WALLS, SHAFT WALLS WITH PHYSICAL SLAB ON ONE SIDE ONLY, USE 10 PSF, FOR WHICH THIS LIMITING HEIGHTS TABLE IS NOT APPLICABLE. ENGINEER SUCH PARTITIONS SEPARATELY. FIRE RATING: TYPE 0V NON RATED SILL PLAN HEAD 1/2"STC-35, NIC-30 W/ 3" MINERAL WOOL BATT & ACOUSTIC SEALANT TAG STUD WIDTH OVERALL WIDTH 2 2 1/2"3 3/4" 3 3 5/8"4 7/8" 4 4"5 1/4" 6 6"7 1/4" BOTTOM OF STRUCTURE PROVIDE TRACK ANCHORAGE AS REQUIRED TO MEET LOADS AND CRITERIA FOR EACH SPECIFIC CONDITION. AT A MINIMUM USE 1/8" PAF AT 1-1/4" MIN EMBEDMENT, WITHIN 2" OF ENDS AND MATCHING STUD SPACING OC MAX MTL BOTTOM RUNNER TRACK CONCRETE FLOOR SLAB, UON SUSPENDED CEILING SYSTEM *PROVIDE MIL THICKNESS AS REQUIRED TO MEET LIMITING HEIGHT CRITERIA AS "COMPOSITE ASSEMBLY" 4" MINIMUM ACOUSTICAL BLANKET, MINIMUM OF 24" ON EACH SIDE OF PARTITION UON WIRE HANGER AND HANGER ANCHORAGE DEVICE DIAGONAL AND VERTICAL BRACE AT 48" OC. SIZE AND GAUGE AS REQUIRED TO MEET LIMITING UNBRACED LENGTH AT 5 PSF APPLIED AT HEAD OF WALL SAFB PER MODIFIER "A" CONT ACOUSTICAL SEALANT CEILING PANEL HOLD-DOWN CLIP PTN ATTACHMENT CLIP CEILING TEE OVERALL WIDTH MTL STUDS SPACED @ 16" 5/8" GWB, (1) LAYER EACH SIDE (2) #8 STMS PER CLIP, ATTACHING TO PTN TRACK (2) #10 STMS ATTACHING BRACE, CLIP AND TEE VERTICAL BRACE CONT NEOPRENE CLOSURE STRIP FIRE RATING: TYPE 0F NOT RATED SILL PLAN CEILING HEAD TAG STUD WIDTH OVERALL WIDTH 2 2 1/2"3 1/8" 3 3 5/8"4 1/4" 4 4"4 5/8" 6 6"6 5/8" BOTTOM OF STRUCTURE • PROVIDE MIL THICKNESS AS REQUIRED TO MEET LIMITING HEIGHT CRITERIA AS "NON- COMPOSITE ASSEMBLY BRACED @ 48" OC" MINIMUM MTL 'U' CHANNEL LATERAL BRACING, TYP MTL CLIP ANGLE, TYP PROVIDE TRACK ANCHORAGE AS REQUIRED TO MEET LOADS AND CRITERIA FOR EACH SPECIFIC CONDITION. AT A MINIMUM USE 1/8" PAF AT 1-1/4" MIN EMBEDMENT, WITHIN 2" OF ENDS AND MATCHING STUD SPACING OC MAX MTL BOTTOM RUNNER TRACK CONT ACOUSTICAL SEALANT CONCRETE FLOOR SLAB, UON 5/8" GWB, (1) LAYER ON FINISH SIDE SAFB PER MODIFIER "A" SUSPENDED CEILING WHERE OCCURS 1/2"OVERALL WIDTH • DEFLECTION TO BE BASED ON L/240 UNLESS OTHERWISE NOTED. • FOR TILE, STONE, ETC., SEE SPECIFICATION FOR DEFLECTION REQUIREMENTS. Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:25 PMPARTITION TYPES LEGEND AND DETAILS A610 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 3" = 1'-0"A TYPE A: FULL HEIGHT: 0- & 1-HR RATED 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 3" = 1'-0"V TYPE V: CEILING HEIGHT: NON RATED 3" = 1'-0"F TYPE F: FULL HT FURRING: NON RATED RATED CONCRETE AND MTL DECK FLOOR SLAB STRUCTURAL BEAM SPRAY-ON FIREPROOFING MTL Z-CHANNELS, 1-1/2" X 20 GA MIN AT 16" OR 24" OC TO MATCH STUD SPACING MAX SEE PLANS FOR PARTITION TYPES PROVIDE UL ASSEMBLIES OR ENGINEERED SYSTEM AT ALL RATED PARTITIONS DRYWALL SCREW, TYP; ATTACH BOTH SIDES OF GWB TO STUDS ONLY CONT FIRE & SMOKE RATED SPRAY-ON SEALANT SYSTEM, BOTH SIDES OF PTN; OVERLAP MIN 1/2" ONTO GWB & SPRAY-ON FIREPROOFING, TYP PROVIDE Z -CHANNEL ANCHORAGE AS REQUIRED TO MEET LOADS AND CRITERIA FOR EACH SPECIFIC CONDITION. AT A MINIMUM USE 1/8" PAF TO FULLY ENGAGE INTO STEEL ADDITIONAL LAYERS OF GWB PER PTN TYPE SAFB IF APPLICABLE PER PTN TYPE WEB STIFFENER TO MEET LIMITING HEIGHT REQUIREMENTS IF REQUIRED SHEET MTL SCREW, TYP RATED CONCRETE AND MTL DECK FLOOR SLAB STRUCTURAL BEAM SPRAY-ON FIREPROOFING MTL Z CHANNELS, 1-1/2" X 20 GA MIN AT 16" OR 24" TO MATCH STUD SPACING, SIZED AS REQD FOR CANTILEVER REQUIREMENTS SEE PLANS FOR PARTITION TYPES PROVIDE UL ASSEMBLIES OR ENGINEERED SYSTEM AT ALL RATED PARTITIONS DRYWALL SCREW, TYP; ATTACH BOTH SIDES OF GWB TO STUDS ONLY AT NON-RATED PTNS: CONT ACOUSTIC SEALANT ON INSULATION AT RATED PTNS: CONT FIRE & SMOKE RATED SPRAY-ON SEALANT SYSTEM, OVERLAP MIN 1" ONTO GWB; EXTEND TO B/MTL DECK BETWEEN STRAPS MIN 2" WIDE 16 GA GALV STL STRAPS AT 16" OR 24" OC TO MATCH STUD SPACING MIN 1/8" PAF, 1-1/4" MIN EMBEDMENT, TYP SHEET MTL SCREW, TYP MINERAL WOOL FIRE SAFING, COMPRESSED TO FILL OPENING PROVIDE Z -CHANNEL ANCHORAGE AS REQUIRED TO MEET LOADS AND CRITERIA FOR EACH SPECIFIC CONDITION. AT A MINIMUM USE 1/8" PAF TO FULLY ENGAGE INTO STEEL ADDITIONAL LAYERS OF GWB PER PTN TYPE SAFB IF APPLICABLE PER PTN TYPE AT NON-RATED PTNS: CONT ACOUSTIC SEALANT ON INSULATION AT RATED PTNS: CONT FIRE & SMOKE RATED SPRAY-ON SEALANT SYSTEM, OVERLAP MIN 1" ONTO GWB WEB STIFFENER TO MEET LIMITING HEIGHT REQUIREMENTS IF REQUIRED MTL STUD SIZED TO FIT BETWEEN SPRAY-ON FIREPROOFING AND INSIDE FACE OF GWB; PROVIDE TOP AND BOTTOM RUNNER TRACKS AND SAFB IF APPLICABLE PER PTN TYPE ENCASE Z CHANNELS IN 1" THICK SPRAY-ON FIREPROOFING AFTER SEALANT INSTALLATION FIRE RATED CONTROL JOINT RATED CONCRETE AND MTL DECK FLOOR SLAB MIN 2" WIDE 16 GA GALV STL STRAPS AT 16" OR 24" OC TO MATCH STUD SPACING MAX PROVIDE TRACK ANCHORAGE AS REQUIRED TO MEET LOADS AND CRITERIA FOR EACH SPECIFIC CONDITION. AT A MINIMUM USE 1/8" PAF AT 1 1/4" MIN EMBEDMENT. 2" FROM EACH END AND TO MATCH STUD SPACING OC MAXIMUM SEE PLANS FOR PARTITION TYPES SHEET MTL SCREW, TYP DRYWALL SCREW, TYP; ATTACH BOTH SIDES OF GWB TO STUDS ONLY ADDITIONAL LAYERS OF GWB PER PTN TYPE SAFB IF APPLICABLE PER PTN TYPE CONT ELASTOMERIC SEALANT ON INSULATION BOTH SIDES AT PTNS WITH SAFB MINERAL WOOL INSULATION; OVERLAP MIN 1" ONTO GWB; EXTEND TO BOTTOM OF MTL DECK BETWEEN STRAPS WEB STIFFENER TO MEET LIMITING HEIGHT REQUIREMENTS IF REQUIRED RATED CONCRETE AND MTL DECK FLOOR SLAB SEE PLANS FOR PARTITION TYPES DRYWALL SCREW, TYP; ATTACH BOTH SIDES OF GWB TO STUDS ONLY ADDITIONAL LAYERS OF GWB PER PTN TYPE SAFB IF APPLICABLE PER PTN TYPE PROVIDE TRACK ANCHORAGE AS REQUIRED TO MEET LOADS AND CRITERIA FOR EACH SPECIFIC CONDITION. AT A MINIMUM USE 1/8" PAF AT 1 1/4" MIN EMBEDMENT. 2" FROM EACH END AND TO MATCH STUD SPACING OC MAXIMUM WEB STIFFENER TO MEET LIMITING HEIGHT REQUIREMENTS IF REQUIRED CONT ACOUSTIC SEALANT ON INSULATION BOTH SIDES OF PTN @ PTNS WITH SAFB MINERAL WOOL INSULATION, OVERLAP MIN 1" ONTO GWB Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:26 PMPARTITION DETAILS A611 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 3" = 1'-0"2A TYP RATED PTN HEAD AT STRUCTURAL BEAM 3" = 1'-0"2B TYP RATED PTN HEAD AT STRUCTURAL BEAM 3" = 1'-0"1A TYP NON-RATED GWB PTN HEAD PARALLEL TO METAL DECK 3" = 1'-0"1B TYP NON-RATED GWB PTN HEAD PERPENDICULAR TO METAL DECK NOTE: SEE PREVIOUS SHEET FOR "GENERAL NOTES FOR INTERIOR PARTITIONS" 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. C-H STUD FASTEN J-TRACK HERE ON BOTH SIDES EXTEND ANCHOR BRACKET 6" MAX BEYOND LAST ATTACHMENT POINT (2) BACK TO BACK MTL STUDS @ 12" OC @ ALL HANGING LOADS ATTACH ANCHOR BRACKET TO EA MTL STUD W/ MIN (3) #8 SELF-TAP SHEET MTL SCREW @ 24" OC, TYP MTL ANCHOR BRACKET: 6" MIN CONT UNPUNCHED MTL STUD, 33 MIL MIN, COPE FLANGES AT EA VERTICAL MTL STUD, SPAN (2) STUDS MIN TOP TRACK -SLIP HEAD -USE NO FASTENER TO SECURE STUDS. SECURE AS PER HEAD DETAILS STUDS PER PARTITION TYPE BOTTOM TRACK SECURED TO HORIZONTAL STUD WITH SMS FASTENERS AT 12" OC MAX AND 6" FROM ENDS HEADER ASSEMBLY TO MEET SPAN AND LOADING REQUIREMENTS, SECURED TO VERTICAL STUDDOUBLE STUD WHERE REQUIRED HORIZONTAL STUD SECURED TO TOP TRACK WITH SMS FASTENERS AT 12" OC MAX AND 6" FROM ENDS TOP TRACK -NOT A SLIP HEAD; SECURED TO VERTICAL STUD WITH FOLDED ENDS STUDS PER PARTITION TYPE SMS FASTENERS AS REQUIRED SMS FASTENERS AS REQUIRED SMS FASTENERS AS REQUIRED REINFORCING STUD 3'-0" TO 6'-6" MAX 3'-0" TO 6'-6" MAX TYP MTL TOP RUNNER TRACK TYP HEADER AT FRAMED OPENING: -RUNNER TRACK UP TO 36" WIDE -RUNNER TRACK WITH STUD REINFORCEMENT FROM 3'-0" TO 6'-6" -PROVIDE BOX BEAM AND RUNNER TRACK FOR ALL OPENING GREATER THAN 6'-6" MTL ANCHOR BRACKETS FOR PARTITION MTD HANDRAILS/GRAB BARS: SPAN (2) MTL STUDS MIN @ EA ATTACHMENT POINT MTL ANCHOR BRACKETS FOR PARTITION MOUNTED CASEWORK & EQUIP: CONT FULL LENGTH OF ASSEMBLY, SPAN (3) MTL STUDS MIN, COORD LOCATION W/ CASEWORK/EQUIP & MFR MOUNTING INSTRUCTIONS, LOCATE MTL ANCHOR BRACKETS AT CL OF ATTACH PT, UON. SEE DETAIL AT THIS SHEET. LINE OF FINISH CEILING UNDERSIDE OF STRUCTURAL SLAB OR MTL DECK DOOR OPNG @ FULL HT PTN AIR TRANSFER OPENING (NO DUCTWORK) TYP CORNER: (3) MTL STUDS MIN ANCHOR BRACKETS CORNER TYP MTL BOTTOM RUNNER TRACK, ATTACH W/ MIN 1/8" PAF SPACED TO MATCH STUD SPACING, 1-1/4" MIN EMBEDMENT, TYP DOUBLE MTL STUDS AT ALL DOOR JAMBS, AND AIR TRANSFER OPENINGS. ADJUST AND ADD STUDS AS REQUIRED 2"x2"x33 MILS MTL ANCHOR ANGLE, FULL WIDTH OF MTL STUD AT MTL STUDS 33 MILS OR GREATER FLOOR SLAB6" MIN, TYPVARIES6" MAX THIS IS NOT A SLIP HEAD CONDITION; ATTACH STUD TO TRACK 3'-0" TO 6'-6" MAX DUCT OPENING TYP MTL TOP RUNNER TRACK TYP SILL AT OPNG: -MTL RUNNER TRACK AT OPENING UNDER 3'-0" -RUNNER TRACK WITH MTL STUD FOR OPENINGS FROM 3'-0" TO 6'-6" -PROVIDE BOX BEAM FOR OPENINGS GREATER THAN 6'-6" TO ACCOMMODATE LATERAL DEFLECTION REQUIREMENTS TYP MTL BOTTOM RUNNER TRACK: ATTACH W/ MIN 1/8" PAF SPACED TO MATCH STUD SPACING, 1-1/4" MIN EMBEDMENT, TYP FOR DUCTS / DAMPERS THAT EXCEED 36" X 36", IN EITHER DIRECTION, ADD DOUBLE STUDS AS REQUIRED TO CONFORM TO DUCT / DAMPER SIZE AND REQUIREMENTS FOR FIRESAFING ANGLES THIS IS NOT A SLIP HEAD CONDITION; ATTACH STUD TO TRACK TYP SLIP HEAD CONDITION DOUBLE TRACK AND STUD ASSEMBLY. PROVIDE BOX BEAM AS REQUIRED FOR SPANS > 6'-6" TYP SILL AT OPNG: -MTL RUNNER TRACK AT OPENING UNDER 3'-0" -RUNNER TRACK WITH MTL STUD FOR OPENINGS FROM 3'-0" TO 6'-6" -PROVIDE BOX BEAM FOR OPENINGS GREATER THAN 6'-6" TO ACCOMMODATE LATERAL DEFLECTION REQUIREMENTS MINIMUM DIMENSION: -FOR DUCTS / DAMPERS FROM 8" TO 18" WIDE = 6" MINIMUM -FOR DUCTS / DAMPERS FROM 18" TO 3'-0" WIDE = 12" -FOR DUCTS FROM 3'-0" TO 6'-6" WIDE = 1'-6" -FOR DUCTS THAT EXCEED 6'-6" COORDINATE REQUIRED ACCESS REQUIREMENTS WITH DUCT / DAMPER INSTALLATION. HEADER TRACK COPED TO ENGAGE STUD 3'-0" TO 6'-6" MAX DUCT OPENING FOR STACKED AND DIFFERENT WIDTH DUCTS TYP SILL AT OPNG: -MTL RUNNER TRACK AT OPENING UNDER 3'-0" -RUNNER TRACK WITH MTL STUD FOR OPENINGS FROM 3'-0" TO 6'-6" -PROVIDE BOX BEAM FOR OPENINGS GREATER THAN 6'-6" TO ACCOMMODATE LATERAL DEFLECTION REQUIREMENTS THIS IS NOT A SLIP HEAD CONDITION; ATTACH STUD TO TRACK TYP SLIP HEAD CONDITION DOUBLE TRACK AND STUD ASSEMBLY. PROVIDE BOX BEAM AS REQUIRED FOR SPANS > 6'-6" MINIMUM DIMENSION: -FOR DUCTS / DAMPERS FROM 8" TO 18"" WIDE = 6" MINIMUM -FOR DUCTS / DAMPERS FROM 18" TO 3'-0" WIDE = 12" -FOR DUCTS FROM 3'-0" TO 6'-6" WIDE = 1'-6" -FOR DUCTS THAT EXCEED 6'-6" COORDINATE REQUIRED ACCESS REQUIREMENTS WITH DUCT / DAMPER INSTALLATION. FOR DUCTS THAT EXCEED 36" X 36", IN EITHER DIRECTION, ADD ADDITIONAL DOUBLE STUD FRAMING TO FRAME OPENING TO SIZE REQUIRED TO PROVIDE FOR DAMPER FIRESAFING ANGLES DAMPER OR DUCT ASSEMBLY. PROVIDE CLEARANCES AND ATTACHMENTS AS REQUIRED BY UL ASSEMBLIES DAMPER OR DUCT ASSEMBLY. PROVIDE CLEARANCES AND ATTACHMENTS AS REQUIRED BY UL ASSEMBLIES TRIM STUD RETURN TO INSTALL PLYWOOD TIGHT TO INSIDE FACE OF STUD MTL STUDS @ 16" OC, TYP ATTACH PLYWOOD TO EA MTL STUD AND ANGLE W/ MIN (2) #8 SELF-TAP SHEET MTL SCREWS AT 12" OC, TYP 3/4" FRTW PLYWOOD, TYP 4" LONG 2"X2" 16GA (64 MIL) ANGLE ATTACHED TO MTL STUDS AT 12" OC VERTICALLY, TYP 3/4" FRTW PLYWOOD, TYP 4" LONG 2"X2" 16GA (64 MIL) ANGLE ATTACHED TO MTL STUDS AT 12" OC VERTICALLY, TYP SEE PLANS AND PARTITION TYPES FOR GWB ATTACH PLYWOOD TO EA MTL STUD AND ANGLE W/ MIN (2) #8 SELF-TAP SHEET MTL SCREWS AT 12" OC, TYP J-TRACK TOP RUNNER MINIMUM DIMENSION: -FOR DUCTS / DAMPERS FROM 8" TO 18" WIDE = 6" MINIMUM -FOR DUCTS / DAMPERS FROM 18" TO 3'-0" WIDE = 12" -FOR DUCTS FROM 3'-0" TO 6'-6" WIDE = 18" -FOR DUCTS THAT EXCEED 6'-6" COORDINATE REQUIRED ACCESS REQUIREMENTS WITH DUCT / DAMPER INSTALLATION. SLIP HEAD CONNECTION, TYP. J-TRACK HEADER WITH ENDS SLOTTED TO FIT INTO C-H STUDS -PROVIDE MIL THICKNESS AS REQUIRED FOR OPENING UP TO 6'-0". -PROVIDE BOX BEAM REINFORCEMENTS FOR OPENINGS OVER 6'-0" TO SUPPORT SPAN AND DEFLECTION REQUIREMENTS DAMPER OR DUCT ASSEMBLY. PROVIDE CLEARANCES AND ATTACHMENTS AS REQUIRED BY UL ASSEMBLIES J-TRACK FOLDED AS SHOWN TO SLIP INTO VOID. ATTACH TO J-TRACK HEADER. PROVIDE FASTENERS AT LEG OVERLAPS. J-TRACK BOTTOM RUNNER -PROVIDE MIL THICKNESS AS REQUIRED FOR OPENING UP TO 6'-0". -PROVIDE BOX BEAM REINFORCEMENT FOR OPENINGS OVER 6'-0" TO SUPPORT SPAN AND DEFLECTION REQUIREMENTS METAL STUDS, TYP 3C A612 CONTROL JOINT, BOTH SIDES OF PARTITION 2 HR RATED PARTITION UON 1/2" CONTROL JOINT, BOTH SIDES OF PARTITION 1 HR RATED PARTITION UON 1/2" MINERAL WOOL FIRE SAFING, COMPRESSED TO FILL OPENING CONTROL JOINT, BOTH SIDES OF PARTITION NON RATED PARTITION UON 1/2" SEE PLANS FOR PARTITION TYPES MTL STUD, BOTH SIDES OF JOINT MINERAL WOOL FIRE SAFING, COMPRESSED TO FILL OPENING MTL STUD, BOTH SIDES OF JOINT CONTROL JOINT 1 HR RATED SHAFTWALL PARTITION UON 1/2" MINERAL WOOL FIRE SAFING, COMPRESSED TO FILL OPENING NON RATED FURRING SEE PLANS FOR PARTITION TYPES MTL J RUNNER, BOTH SIDES OF JOINT CONT FIRE SEALANT DRYWALL SCREW, TYP CONTROL JOINT 2 HR RATED SHAFTWALL PARTITION UON 1/2" MINERAL WOOL FIRE SAFING, COMPRESSED TO FILL OPENING MTL J RUNNER, BOTH SIDES OF JOINT CONT FIRE SEALANT, TYP DRYWALL SCREW, TYP DRYWALL SCREW, TYP MTL STUD, BOTH SIDES OF JOINT DRYWALL SCREW, TYP DRYWALL SCREW, TYP CONT FIRE SEALANT, BOTH SIDES OF PARTITION CONTROL JOINT 1 HR RATED SHAFTWALL PARTITION UON 1/2" TWO LAYERS 5/8" TYPE SCX GWB MTL J RUNNER, BOTH SIDES OF JOINT DRYWALL SCREW, TYP CONTROL JOINT 2 HR RATED SHAFTWALL PARTITION UON 1/2" TWO LAYERS 5/8" TYPE SCX GWB SEE PLANS FOR PARTITION TYPES PROVIDE UL ASSEMBLIES OR ENGINEERED SYSTEM AT ALL RATED PARTITIONS MTL J RUNNER, BOTH SIDES OF JOINT DRYWALL SCREW, TYP CONT FIRE SEALANT CONT FIRE SEALANT CONT FIRE SEALANT, BOTH SIDES OF PARTITION CONT FIRE SEALANT, TYP HIGHER PRIORITY PARTITION LOWER PRIORITY PARTITION TAPE AND JOINT COMPOUND HIGHER PRIORITY PARTITION LOWER PRIORITY PARTITION TAPE AND JOINT COMPOUND HIGHER PRIORITY PARTITION LOWER PRIORITY PARTITION TAPE AND JOINT COMPOUND EQUAL PRIORITY PARTITIONS EQUAL PRIORITY PARTITIONS PARTITION PRIORITY LEGEND 3 HOUR SHAFTWALL 1 -HIGHEST 3 HOUR PARTITION 1 2 HOUR SHAFTWALL 2 2 HOUR PARTITION 2 1 HOUR SHAFTWALL 3 1 HOUR PARTITION 3 SMOKE PARTITION 4 NON-RATED PARTITION 5 -LOWEST T INTERSECTION -UNEQUAL PRIORITY PARTITION T INTERSECTION -UNEQUAL PRIORITY PARTITION X INTERSECTION -UNEQUAL PRIORITY PARTITION T INTERSECTION -EQUAL PRIORITY PARTITION X INTERSECTION -EQUAL PRIORITY PARTITION NOTE: MAINTAIN GYPSUM WALL BOARD ON HIGHER PRIORITY WALL AT INTERSECTION WITH LOWER PRIORITY WALL AS INDICATED. NOTE: NUMBER OF LAYERS INDICATED IS REPRESENTATIVE OF THE NUMBER OF LAYERS OF GYPSUM WALL BOARD FOR PRIORITY AT INTERSECTION. SEE ACTUAL PARTITION TYPES FOR NUMBER OF LAYERS AND DETAIL REQUIREMENTS. ALTERNATE X INTERSECTION -EQUAL PRIORITY PARTITION ALTERNATE T INTERSECTION -EQUAL PRIORITY PARTITION EQUAL PRIORITY PARTITION MINERAL WOOL IN 1/2" GAP TAPE AND JOINT COMPOUND OUTER LAYER 1/2" GAP ON INNER LAYER FILLED WITH INTUMESCENT SEALANT EQUAL PRIORITY PARTITION MINERAL WOOL IN 1/2" GAP TAPE AND JOINT COMPOUND OUTER LAYER 1/2" GAP ON INNER LAYER FILLED WITH INTUMESCENT SEALANT 3-5/8"w X 2-1/2"d X 1/8" EXTRUDED ALUM CHANNEL. FINISH TO MATCH EXISTING MULLION. MINERAL WOOL FIRE SAFING INSULATION COMPRESSED TO FILL OPENING CURTAIN WALL SYSTEM TYP VERTICAL MULLION 5/8"d EXTRUDED ALUM Z-REVEALS; COPE TOP AND BOTTOM TO ENGAGE CLG SYSTEM AND ENCLOSURE AT SILL. FINISH LEG TO MATCH MULLION. EDGE OF SLAB BELOW, VIF LINE OF ALUM SILL EXTENSION AND FIRESTOPPING COVER FRTW BLOCKING SEALANT AND BACKER ROD, TYP TAPING COMPOUND, TYP SEE PLANS FOR PTN TYPE 1" MIN 1" OVERLAP Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:27 PMPARTITION FRAMING DETAILS A612 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 3" = 1'-0"3C J-TRACK C-H STUD 1 1/2" = 1'-0"2C TYP METAL STUD ANCHOR BRACKET/GROUND 1 1/2" = 1'-0"2E CONNECTION DETAIL AT DUCT, BORROWED HM LITES, AND MISCELLANEOUS OPENINGS 1/2" = 1'-0"1D TYP METAL 'C' STUD FRAMING DIAGRAM 1 1/2" = 1'-0"2D TYP METAL STUD WOOD BLOCKING DETAIL 1/2" = 1'-0"1E TYP SHAFTWALL FRAMING DIAGRAM FOR DUCT AND DAMPER PENETRATIONS 3" = 1'-0"3E TYPICAL PTN CONTROL JOINTS DET 1 1/2" = 1'-0"2B TYPICAL PTN INTERSECTIONS 3" = 1'-0"2A PTN TERMINATION AT MULLION NOTE: SEE PREVIOUS SHEET FOR "GENERAL NOTES FOR INTERIOR PARTITIONS" 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. DOOR PANEL AND FRAME TYPE DIAGRAMS DOOR TYPE AS SCHED FRAME TYPE 01 DOOR OPENING DOOR TYPE F FLUSH PANEL HARDWARE SETS HARDWARE TYPE EX EXISTING DOOR AND FRAME TO REMAIN INDICATES EXISTING HARDWARE SET. REPLACE ANY NON-FUNCTIONING OR BROKEN DEVICES AT THIS LOCATION WITH NEW TO MATCH EXISTING. NEW HARDWARE FUNCTIONS TO MATCH EXISTING HARDWARE FUNCTION AND KEYING AT SAME DOOR (i.e. AN EXISTING LOCKING DOOR IS TO RECEIVE A NEW SIMILARLY LOCKING HARDWARE SET). HARDWARE TYPE 1 -SINGLE FLUSH DOOR-PASSAGE (DOOR 320) TYPICAL OFFICE HINGES:(4) MATCH EXISTING OFFICE PASSAGE SET:(1) MATCH EXISTING FLOOR STOP:(1) MATCH EXISTING SILENCERS:(3) MATCH EXISTING HARDWARE TYPE 6 -SINGLE FLUSH DOOR-PRIVACY LOCKING (DOOR 306) HINGES:(4) MATCH EXISTING PRIVACY LOCK SET (1) MATCH EXISTING WITH "OCCUPIED" INDICATOR: OVERHEAD CLOSER:(1) MATCH EXISTING WALL STOP:(1) MATCH EXISTING SILENCERS:(3) MATCH EXISTING NOTE: MOUNT CLOSER TO "INSIDE" FACE OF DOOR. NO EXPOSED FASTENERS AT EITHER FACE OF DOOR. CLOSER HOUSING TO BE CUSTOM FINISHED TO MATCH DOOR FINISH. NOTE: COORDINATE WALL STOP / BUMPER LOCATION WITH HANDSET SPINDLE. PROVIDE ADDITIONAL CONCEALED BLOCKING IN PARTITION FOR IMPACT SUPPORT. HARDWARE TYPE 7 -SINGLE SWING DOOR -ELECTRIC STRIKE LOCK (DOOR 319) HINGES:(4) MATCH EXISTING FAIL SECURE LOCK:(1) ELECTRIC STRIKE SURFACE CLOSER::(1) MATCH EXISTING FLOOR STOP:(1) MATCH EXISTING SILENCERS:(3) MATCH EXISTING POWER SUPPLY FOR CARD READER (1): POWER SUPPLY FOR ELECTRIC STRIKE (1): NOTE: BALANCE OF ELECTRONIC HARDWARE (INCLUDING CARD READER, MONITORING SWITCH, REQUEST TO EXIT BUTTON, MOTION SENSOR, ETC.) TO BE SPECIFIED BY SECURITY VENDOR. CONTRACTOR TO PROVIDE FULLY FUNCTIONING ASSEMBLY AT PROJECT COMPLETION. OPENING CODE PANEL TYPE MAT'L FINISH No. OF LEAVES WIDTH NOMINAL SIZE HEIGHT THCKNSRATING DOOR JAMB COMMENTS FRAME TYPE MAT'L FINISH A AS PER CODE TAGGED AT EACH DOOR LOCATION ON CONSTRUCTION PLANS DOOR AND OPENING LEGEND B C ABBREVIATIONS AL ALUMINUM EX EXISTING GL GLASS HM HOLLOW METAL MLLWRK MILLWORK MTL METAL PT PAINT SC SOLID CORE DOOR STC SOUND TRANSMISSION CLASS STL STEEL WD WOOD HEADGENERAL DESCRIPTION RELOCATED EXISTING MATCH EXISTING EXISTING OPENING NOTES SECTIONS -----------EXISTING DOOR REINSTALLED-- ------------- -------------EXISTING TO REMAIN MATCH EXISTING 2"1/2"1/2" 1 15/16"1 15/16"DOOR HEIGHT AS SCHEDULEDPTN TYPE AS INDICATED PROVIDE FRAMING AS INDICATED BY MTL STUD FRAMING DIAGRAMS FRAME AS SCHEDULED DOOR TYPE AS SCHEDULED LINE OF ASSEMBLY BEYOND GASKET AS SCHEDULED5/8"2"1/2"1/2"4" UON 1 15/16"1 15/16"INTERSECTING PTN WHERE OCCURS DOOR WIDTH AS SCHEDULED PTN TYPE AS INDICATED PROVIDE FRAMING AS INDICATED BY MTL STUD FRAMING DIAGRAMS FRAME AS SCHEDULED ATTACH W/ MIN (2) #8 STMS HM FRAME WALL ANCHORS, MIN (3) PER JAMB GASKET AS SCHEDULED DOOR TYPE AS SCHEDULED 1/2" MIN GWB PENETRATION TYP 5/8" Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:28 PMDOOR, FRAME, HARDWARE LEGENDS, AND DETAILS A620 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 6" = 1'-0"1 HEAD DETAIL 6" = 1'-0"3 JAMB DETAIL PL-01 MILLWORK BASE AS SCHEDULED PL-02 COUNTERTOP 5'-0"10'-0"MAX2'-10"EQUIP. VERIFY W/3'-1" RE-USE EXISTING REF LOCK FLOOR FINISH TO EXTEND BELOW COVE WALL BASE. RESILIENT SHOWN FOR REFERENCE -ACTUAL FLOOR FINISH MAY BE DIFFERENT. TOP EDGES OF RESILIENT BASE CONFIGURATIONS TO ALIGN THROUGHOUT. SCHEDULED PARTITION. ALIGN STRAIGHT BASE AT CARPET COVE BASE AT RESILIENT OR HARD SURFACE FLOORING CARPET FINISH TO COVER BOTTOM OF STRAIGHT WALL BASE. CARPET-TO-CARPET TIGHT JOINT. CENTER BELOW DOOR THICKNESS WHEN PRESENT. WHEN ADJACENT CARPET THICKNESS DIFFERENCE IS GREATER THAN 1/4", PROVIDE BUILT-UP UNDERLAYMENT TO YIELD EVEN TRANSITION. SCHEDULED CARPET FINISH. SCHEDULED CARPET FINISH. INDICATES DOOR IN CLOSED POSITION WHEN PRESENT. EXTRUDED RESILIENT REDUCER STRIP, CONTINUOUS. CENTER BELOW DOOR THICKNESS WHEN PRESENT. RESILIENT TILE OR SHEET FLOOR FINISH. SCHEDULED CARPET FINISH. INDICATES DOOR IN CLOSED POSITION WHEN PRESENT. RECTANGULAR PULL. SEE TYP PULL MOUNTING GUIDE AT THIS SHEET.2'-10"3"4"PARTITION TYPE. SEE PLAN 4" TALL CONT BACKSPLASH UON AT ELEV. CLEAR SEALANT AT JOINT COUNTERTOP AS SHOWN ON ELEVATION MULTIPLE HOLE AND 1/4" HEAVY- DUTY PIN SUPPORTS AT 3" OC 3/4" MDF ADJ SHELF, PLAM FINISH ALL SIDES AND EDGES FULL OVERLAY CONCEALED HINGES CABINET SWING DOOR, PLAM FINISH AT FACES AND EDGES CONT PLAM BASE ON FINISHED MDF BACKER FL FINISH. SEE PLAN CONT WD CLEATS TOP AND BOTTOM AT FULL FINISH MDF BACK PANEL. METAL ANCHOR BRACKETS IN PARTITION CABINET BODY 2'-0"2"INTERIOR CABINET TO BE WHITE MELAMINE PREPARE FOR ELECTRICAL DEVICE PLACEMENT Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING Prepared For Project No: PERMIT & CONSTRUCTION 4.21.2023 AREA OF WORK 2023-05-09 1:02:29 PMELEVATIONS AND DETAILS A801 Verizon Indianapolis 250 E. 96th Street, 3rd Floor Indianapolis, Indiana VERIZON 23.09600.00 Client Location 2023 717 North Harwood Street Suite 2850, LB 8 Dallas, TX 75201 USA t +1 214 720 6000 www.hok.com Hellmuth, Obata & Kassabaum, Inc. 3/8" = 1'-0"1 WELLNESS VANITY 6" = 1'-0"3 RESILIENT WALL BASE 6" = 1'-0"4 CARPET TO CARPET 6" = 1'-0"5 CARPET TO RESILIENT FLOOR 1 1/2" = 1'-0"2 DOOR BASE CABINET Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001M-1Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DNUPUPDNWELLNESS306MEDIUMCONF.305FOCUS324STORAGE323SMALLCONF.322SMALLCONF.321MEDIUMCONF.305LARGECONF.320OPEN OFFICEOPEN OFFICEOPEN OFFICELEVEL 3 FLOOR PLAN - MECHANICAL, DEMOLITIONSCALE: 1/8" = 1'-0"NEX. 8"ØEX. 10/14 EX. 16/14EX. 14/14 TTTTTTTTTTEX. 6"Ø EX. 6"ØEX. 10"ØEX. 8"ØEX. 8"ØEX. 10"ØEX. 14"ØEX. 8"ØEX. 10"Ø EX. 10"ØEX. 14"ØEX. 10"Ø EX. 10"Ø EX. 10"ØEX. 12"ØEX. 12"ØEX. 12"ØEX. 12"ØEX. 14"ØEX. 14"ØEX. 8"ØEX. 6"ØEX. 8"ØEX. 6"ØEX. 10"ØEX. 6"ØEX. 8"ØEX. 14/12EX. 10"ØEX. 10"ØEX. 10"ØEX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.NEW CAPNEW CAPNOTES INDICATED BY NUMBER IN :1. EXISTING SUPPLY AIR DUCT SHOWN "HATCHED" AND ALL RELATED SUPPORTS TO BEREMOVED.2. INSTALL INSULATED SHEET METAL CLOSURE OVER EXISTING DUCT OPENING. SET IN FULLBEAD OF MASTIC AND SECURE IN PLACE WITH SHEET METAL SCREWS 6" O.C. MAX. SPACING.3. EXISTING 24X24 LAY-IN SUPPLY AIR DIFFUSER TO BE REMOVED AND/OR RELOCATED. REFERTO SHEET M-2 FOR REVISED DIFFUSER LOCATION.4. EXISTING 24" LAY-IN LINEAR SLOT DIFFUSER TO BE REMOVED AND/OR RELOCATED. REFER TOSHEET M-2 FOR REVISED SLOT DIFFUSER LOCATION.5. EXISTING 24X12 LAY-IN EGG-CRATE RETURN AIR GRILLE TO BE RELOCATED. REFER TO SHEETM-2 FOR REVISED GRILLE LOCATION.6. EXISTING WALL MOUNTED DIGITAL THERMOSTAT TO BE RELOCATED.7. EXISTING WALL MOUNTED DIGITAL THERMOSTAT TO REMAIN. PROTECT DURINGCONSTRUCTION.8. REMOVE EXISTING SUPPLY AIR DUCT FLEXIBLE DUCT AND ALL RELATED SUPPORTS BACK TOMANUAL BALANCING DAMPER, VERIFY EXACT LOCATION.9. EXISTING ABANDONED 10" Ø DUCT ABOVE CEILING TO BE REMOVED COMPLETELY.GENERAL DEMOLITION NOTES:1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING CONDITIONS ATTHE JOBSITE PRIOR TO BEGINNING DEMOLITION AND BRING TO THE TEAM'S ATTENTION ANYDISCREPANCIES.2. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION WORK OF THIS PROJECTWHICH IS RELATED TO HIS FIELD.3. ITEMS REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BEREMOVED FROM THE JOBSITE BY THE CONTRACTOR AND DISPOSED OF IN ACCORDANCE WITHTHE AUTHORITY HAVING JURISDICTION (AHJ). ANY ITEM DEEMED AS "REGULATED" SUCH ASREFRIGERANT, BALLAST, AND SIMILAR SHALL HAVE DOCUMENTATION REQUIRED BY THE AHJPROVIDED BY THE CONTRACTOR TO THE PROJECT TEAM.4. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, PATCHING, REPAIRING, ANDPAINTING ANY STRUCTURE DAMAGED DUE TO THE DEMOLITION WORK OF THIS PROJECTRELATED TO HIS FIELD OR THE INSTALLATION OF REQUIRED ITEMS INSTALLED UNDER THEPROJECT RELATED TO HIS FIELD WITH MATERIALS AND METHODS TO MATCH EXISTING AND ASAPPROVED BY THE ARCHITECT.5. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY ITEM RELATED TO HISFIELD REQUIRED BY THE DEMOLITION WORK OF THIS PROJECT.EXISTING CONDITIONS NOTE:1. EXISTING CONDITIONS WERE TAKEN FROM THE OWNERS RECORD DRAWINGS. IT SHALL BETHE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOBSITE PRIOR TO BID DATE AND TOASCERTAIN EXISTING CONDITIONS. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OFTHE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PERPLANS AND SPECIFICATIONS, ALL AT NO ADDITIONAL COST TO OWNER OR ENGINEER.1TYPICAL225633344389671TYPICAL62(RELOCATE /FIELD VERIFYEXACT LOCATION)LEVEL 3 FLOOR PLAN -MECHANICAL,DEMOLITION3PERMIT & CONSTRUCTION04/21/2023 Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001M-2Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DNUPUPDNLEVEL 3 FLOOR PLAN - MECHANICAL, NEWSCALE: 1/8" = 1'-0"NEX. 8"ØEX. 10/14 EX. 16/14EX. 14/14 TTTTTTTEX. 6"Ø EX. 6"ØEX. 10"ØEX. 14"ØEX. 8"ØEX. 14"ØEX. 10"Ø EX. 10"Ø EX. 10"Ø12"ØEX. 12"ØEX. 12"ØEX. 12"ØEX. 14"ØEX. 14"ØEX. 8"ØEX. 6"ØEX. 8"ØEX. 6"ØEX. 10"ØEX. 6"ØEX. 8"ØEX. 10"ØEX. 10"ØEX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.EX. F.C.U.MDTTTNEW 10"Ø10"Ø10"Ø8"ØNOTES INDICATED BY NUMBER IN :1. NEW FLEX. SUPPLY AIR DUCT TRANSITION AS REQUIRED AND EXTEND TO DIFFUSER.2. RELOCATED 24X24 LAY-IN SUPPLY AIR DIFFUSER. PROVIDE TRANSITION COLLAR AS REQUIREDTO CONNECT TO FLEX. DUCT.3. RELOCATED 24" LAY-IN LINEAR SLOT DIFFUSER.4. RELOCATED 24X12 LAY-IN RETURN AIR GRILLE.5. NEW 24X12 LAY-IN RETURN AIR GRILLE, TYPE "A". MODIFY CEILING GRID & TILE TO ACCEPT NEWGRILLE.6. RELOCATED WALL MOUNTED DIGITAL THERMOSTAT. EXTEND CONTROL CONDUCTORS TOEXISTING ABOVE CEILING FCU.7. INSTALL NEW SUPPLY AIR DUCT FLEXIBLE DUCT SIZED TO MATCH EXISTING. EXTEND TOEXISTING MANUAL BALANCING DAMPER, VERIFY EXACT LOCATION.NEWNEWNEWNEW1TYPICAL222355AIR OUTLET AND GRILLE SCHEDULECONTROL DAMPEROR DEVICETYPE OUTLETMTG. FRAMETYPE OFDEFLECTROLVOLUMEREMARKSTYPE OF FACEDESIGN.AMFG.RETURNN/ANOT REQUIREDLAY-INEGG CRATE GRILLETITUS 50F451/2"X1/2"X1/2" ALUMINUM CORE ONLY, WHITE FINISH6667WELLNESS306MEDIUMCONF.305FOCUS324STORAGE323SMALLCONF.322SMALLCONF.321MEDIUMCONF.305LARGECONF.320OPEN OFFICEOPEN OFFICEOPEN OFFICELEVEL 3 FLOOR PLAN -MECHANICAL, NEW504/21/2023PERMIT & CONSTRUCTION3 Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001FP-1Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DNUPUPDNLEVEL 3 FLOOR PLAN - FIRE PROTECTION SYSTEMSCALE: 1/8" = 1'-0"NGENERAL DEMOLITION NOTES:1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING CONDITIONS ATTHE JOBSITE PRIOR TO BEGINNING DEMOLITION AND BRING TO THE TEAM'S ATTENTION ANYDISCREPANCIES.2. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION WORK OF THIS PROJECTWHICH IS RELATED TO HIS FIELD.3. ITEMS REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BEREMOVED FROM THE JOBSITE BY THE CONTRACTOR AND DISPOSED OF IN ACCORDANCE WITHTHE AUTHORITY HAVING JURISDICTION (AHJ). ANY ITEM DEEMED AS "REGULATED" SUCH ASREFRIGERANT, BALLAST, AND SIMILAR SHALL HAVE DOCUMENTATION REQUIRED BY THE AHJPROVIDED BY THE CONTRACTOR TO THE PROJECT TEAM.4. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, PATCHING, REPAIRING, ANDPAINTING ANY STRUCTURE DAMAGED DUE TO THE DEMOLITION WORK OF THIS PROJECTRELATED TO HIS FIELD OR THE INSTALLATION OF REQUIRED ITEMS INSTALLED UNDER THEPROJECT RELATED TO HIS FIELD WITH MATERIALS AND METHODS TO MATCH EXISTING AND ASAPPROVED BY THE ARCHITECT.5. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY ITEM RELATED TO HISFIELD REQUIRED BY THE DEMOLITION WORK OF THIS PROJECT.EXISTING CONDITIONS NOTE:1. EXISTING CONDITIONS WERE TAKEN FROM THE OWNERS RECORD DRAWINGS. IT SHALL BETHE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOBSITE PRIOR TO BID DATE AND TOASCERTAIN EXISTING CONDITIONS. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OFTHE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PERPLANS AND SPECIFICATIONS, ALL AT NO ADDITIONAL COST TO OWNER OR ENGINEER.JRELOCATERELOCATERELOCATERELOCATERELOCATENEWNOTES INDICATED BY NUMBER IN :1. REMOVE EXISTING SPRINKLER HEAD DURING DEMOLITION AND RELOCATE EXISTINGSPRINKLER HEAD AS INDICATED IN CENTER OF NEW CEILING TILE. EXTEND 1" SUPPLY ASREQUIRED.2. NEW SPRINKLER HEAD TO MATCH BUILDING STANDARD. PROVIDE NEW TAP OFF EXISTINGBRANCH LINE AND EXTEND NEW 1" SUPPLY.GENERAL NOTES:1. LIGHT FIXTURES AND HVAC GRILLES SHOWN FOR INFORMATION AND COORDINATIONPURPOSES.NEW OR RELOCATED FIRE SPRINKLERSYMBOLDESCRIPTIONFIRE SPRINKLER LEGENDEXISTING FIRE SPRINKLERFIRE PROTECTION AND SPRINKLER SYSTEM:THE EXISTING AREA TO BE REMODELED IS PROTECTED BY AN EXISTING FIRE SPRINKLER SYSTEM.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE JOB SITE AND FIELD VERIFY THEEXISTING SPRINKLER LAYOUT. HE SHALL PROVIDE &/OR RELOCATE HEADS INTO NEWCEILING/AREAS SHOWN.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE SHOP DRAWINGS, HYDRAULIC &OTHER CALCULATIONS REQUIRED TO OBTAIN THE APPROVAL OF THE LOCAL BUILDINGINSPECTION AUTHORITY, LOCAL FIRE DEPARTMENT, AND THE BUILDING INSURANCE CARRIER'SAPPROVAL OF THE FIRE SYSTEM AS PROPOSED PRIOR TO BEGINNING WORK.CONTRACTOR SHALL SUBMIT TO THE CONSULTANT ELECTRONIC SHOP DRAWINGS APPROVED BYTHE ABOVE PARTIES. THE SHOP DRAWINGS SHALL CONSIST OF ILLUSTRATIONS, SCHEDULES,PERFORMANCE CHARTS, INSTRUCTIONS, BROCHURES, DIAGRAMS, AND COMPLETE SHOPDRAWINGS OF THE PROPOSED WORK AND ANY OTHER INFORMATION REQUIRED TO ILLUSTRATETHE SYSTEM HAS BEEN COORDINATED AND WILL FUNCTION AS A UNIT.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ARRANGE FOR AND PAY ALL COST INCONNECTION WITH ALL ACCEPTANCE TESTS FOR THE RENOVATED SYSTEM. THE SPRINKLERWORK SHALL BE MODIFIED, ADDED, ETC., AS REQUIRED TO OBTAIN AN APPROVAL OF THEINSTALLED WORK BY THE ABOVE AUTHORIZED INCLUDING THE STATE OF INDIANA.IN ADDITION TO THE WORK COMPLYING WITH ALL LOCAL AND ORDINANCES, THE WORK SHALLCOMPLY WITH THE FOLLOWING:(1) CITY FIRE DEPARTMENT STANDARDS(2) REGULATIONS OF THE 2014 INDIANA FIRE CODE (IFC 2012).(3)NATIONAL FIRE PROTECTIONS ASSOCIATION STANDARDS: NFPA13 - SPRINKLER SYSTEM.PENDENT SPRINKLER HEADNO SCALE1" DROPCON. PENDENT BRASSFINISH, HEAD SHALL BECENTER OF TILEBRANCH PIPEEX. FIRE SPRINKLERBRANCH LINE, VERIFYLOCATION211111NEW 1"LEVEL 3 FLOOR PLAN -FIRE PROTECTIONSYSTEM3PERMIT & CONSTRUCTION04/21/2023 Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001E-1Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DNUPUPDNLEVEL 3 FLOOR PLAN - ELECTRICAL LIGHTING, DEMOLITIONSCALE: 1/8" = 1'-0"NGENERAL DEMOLITION NOTES:1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING CONDITIONS ATTHE JOBSITE PRIOR TO BEGINNING DEMOLITION AND BRING TO THE TEAM'S ATTENTION ANYDISCREPANCIES.2. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION WORK OF THIS PROJECTWHICH IS RELATED TO HIS FIELD.3. ITEMS REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BEREMOVED FROM THE JOBSITE BY THE CONTRACTOR AND DISPOSED OF IN ACCORDANCE WITHTHE AUTHORITY HAVING JURISDICTION (AHJ). ANY ITEM DEEMED AS "REGULATED" SUCH ASREFRIGERANT, BALLAST, AND SIMILAR SHALL HAVE DOCUMENTATION REQUIRED BY THE AHJPROVIDED BY THE CONTRACTOR TO THE PROJECT TEAM.4. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, PATCHING, REPAIRING, ANDPAINTING ANY STRUCTURE DAMAGED DUE TO THE DEMOLITION WORK OF THIS PROJECTRELATED TO HIS FIELD OR THE INSTALLATION OF REQUIRED ITEMS INSTALLED UNDER THEPROJECT RELATED TO HIS FIELD WITH MATERIALS AND METHODS TO MATCH EXISTING AND ASAPPROVED BY THE ARCHITECT.5. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY ITEM RELATED TO HISFIELD REQUIRED BY THE DEMOLITION WORK OF THIS PROJECT.EXISTING CONDITIONS NOTE:1. EXISTING CONDITIONS WERE TAKEN FROM THE OWNERS RECORD DRAWINGS. IT SHALL BETHE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOBSITE PRIOR TO BID DATE AND TOASCERTAIN EXISTING CONDITIONS. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OFTHE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PERPLANS AND SPECIFICATIONS, ALL AT NO ADDITIONAL COST TO OWNER OR ENGINEER.MD J1. EXISTING CEILING AND LIGHT FIXTURES TO REMAIN. MAINTAIN EXISTING SWITCHING.2. EXISTING RECESSED LIGHT FIXTURES TO BE REMOVED.3. EXISTING SWITCH CONTROLLING ROOM LIGHTING CIRCUIT TO BE REMOVED.4. EXISTING CEILING MOUNTED EMERGENCY LIGHT TO BE REMOVED.5. EXISTING LIGHT FIXTURES ALONG WITH ALL RELATED CONDUIT AND CONDUCTORS TOBE REMOVED COMPLETELY BACK TO PANELBOARD OR LAST ACTIVE DEVICE INCEILING TO REMAIN. VERIFY EXISTING CIRCUIT AND MAINTAIN INTEGRITY OF EXISTINGLIGHTING TO REMAIN.6. EXISTING LIGHT FIXTURE TO BE RELOCATED. REFER TO SHEET E-2 FOR NEW FIXTURELOCATION.7. EXISTING CEILING MTD. EXIT LIGHT FIXTURE TO BE RELOCATED.8. EXISTING OPEN OFFICE LIGHT SWITCHES TO BE REMOVED. REFER TO SHEET E-3 FORNEW SWITCH LOCATION.9. THIS CONTRACTOR SHALL PAY ALL COSTS TO BUILDING LANDLORD APPROVED FIREALARM SYSTEM CONTRACTOR TO REMOVE EXISTING WALL MOUNTED FIRE ALARMSTROBE. REFER TO SHEET E-3 FOR NEW FIRE ALARM SYSTEM REQUIREMENTS.NOTES INDICATED BY NUMBER IN :11112TYP. OF 6334EX. LIGHT FIXTURESSHOWN "CROSSHATCHED"TO BE REMOVED, TYP.THROUGHOUT5EX. WALL CONSTRUCTIONSHOWN "DASHED" TO BEREMOVED, REFER TO ARCH, TYP.661E77VEX. FIRE ALARMSTROBE TO BEREMOVED9LEVEL 3 FLOOR PLAN -ELECTRICAL LIGHTING,DEMOLITION3 PERMIT & CONSTRUCTION04/21/2023 Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001E-2Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DNUPUPDN102103104105106107108109110111112113114115116117118119120121122123124125126127128134133132131130129138139137136135150140141142143144145146147148149151152153154155156157162163168167166165164161158159160172173174171170169178177176175LEVEL 3 FLOOR PLAN - ELECTRICAL POWER, DEMOLITIONSCALE: 1/8" = 1'-0"NGENERAL DEMOLITION NOTES:1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING CONDITIONS ATTHE JOBSITE PRIOR TO BEGINNING DEMOLITION AND BRING TO THE TEAM'S ATTENTION ANYDISCREPANCIES.2. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION WORK OF THIS PROJECTWHICH IS RELATED TO HIS FIELD.3. ITEMS REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BEREMOVED FROM THE JOBSITE BY THE CONTRACTOR AND DISPOSED OF IN ACCORDANCE WITHTHE AUTHORITY HAVING JURISDICTION (AHJ). ANY ITEM DEEMED AS "REGULATED" SUCH ASREFRIGERANT, BALLAST, AND SIMILAR SHALL HAVE DOCUMENTATION REQUIRED BY THE AHJPROVIDED BY THE CONTRACTOR TO THE PROJECT TEAM.4. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, PATCHING, REPAIRING, ANDPAINTING ANY STRUCTURE DAMAGED DUE TO THE DEMOLITION WORK OF THIS PROJECTRELATED TO HIS FIELD OR THE INSTALLATION OF REQUIRED ITEMS INSTALLED UNDER THEPROJECT RELATED TO HIS FIELD WITH MATERIALS AND METHODS TO MATCH EXISTING AND ASAPPROVED BY THE ARCHITECT.5. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY ITEM RELATED TO HISFIELD REQUIRED BY THE DEMOLITION WORK OF THIS PROJECT.EXISTING CONDITIONS NOTE:1. EXISTING CONDITIONS WERE TAKEN FROM THE OWNERS RECORD DRAWINGS. IT SHALL BETHE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOBSITE PRIOR TO BID DATE AND TOASCERTAIN EXISTING CONDITIONS. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OFTHE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PERPLANS AND SPECIFICATIONS, ALL AT NO ADDITIONAL COST TO OWNER OR ENGINEER.AVJPPPPPPPPPPPPCLG(2)(2)(2)64"64"64"JJDJPJPJPJJJPDDJPJD JDJPJPJ DJPJDJP J DPPPPCR(2)60"JAV60"60"AV60"AV60"60"60"60"(3)AV60"60"1. CONTRACTOR SHALL REMOVE COMPLETELY ALL ELECTRICAL DEVICES SHOWNCROSSHATCHED AND ALL RELATED CONDUITS & CONDUCTORS BACK TO ELECTRICALPANEL SERVING SAME OR LAST ACTIVE DEVICE IN CIRCUIT TO REMAIN. VERIFYEXISTING CIRCUIT AND MAINTAIN INTEGRITY OF EXISTING RECEPTACLES TO REMAIN.2. EXISTING POWER AND DATA J-BOX SERVING FURNITURE SYSTEM TO BE REMOVED.THIS CONTRACTOR TO DISCONNECT POWER FROM FURNITURE AND OWNER TORETAIN "WHIP" CONNECTION CABLES.3. EXISTING A/V CABINET TO BE REMOVED BY OTHERS.4. EXISTING POWERED WHITEBOARD TO BE REMOVED BY OTHERS.5. EXISTING MOTORIZED PROJECTION SCREEN AND WALL SWITCH TO BE REMOVED.6. EXISTING OVERHEAD PROJECTOR TO BE REMOVED BY OTHERS.7. EXISTING POWER / DATA / AV SERVING EXISTING WALL MOUNTED MONITORS TO BEREMOVED AS REQUIRED FOR INSTALLATION OF NEW MONITORS AND MOUNTINGHARDWARE. REFER TO NEW POWER PLAN AND AV DRAWINGS FOR NEW ROUGH-INREQUIREMENTS.8. EX. CARD READER TO BE REMOVED BY OTHERS. THIS CONTRACTOR SHALL REMOVEWALL BOX AND CONDUIT BACK TO SOURCE.NOTES INDICATED BY NUMBER IN :EX. WALL CONSTRUCTIONSHOWN "DASHED" TO BEREMOVED, REFER TO ARCH, TYP.34562EX. FURNITURESHOWN DASHEDTO BE REMOVEDBY OTHERSEX. ELECTRICAL DEVICESSHOWN "CROSSHATCHED"TO BE REMOVED, TYP.THROUGHOUT1EX. ELECTRICAL DEVICESSHOWN "CROSSHATCHED"TO BE REMOVED, TYP.THROUGHOUT1LEVEL 3 FLOOR PLAN -ELECTRICAL POWER,DEMOLITION77773 PERMIT & CONSTRUCTION04/21/2023 Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001E-3Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DNUPUPDNLEVEL 3 FLOOR PLAN - ELECTRICAL LIGHTING, DEMOLITIONSCALE: 1/8" = 1'-0"NJ1. EXISTING CEILING AND LIGHT FIXTURES TO REMAIN. MAINTAIN EXISTING SWITCHING.2. NEW WALL MOUNTED SWITCH WITH OCCUPANCY SENSOR. DEVICE SHALL BECAPABLE OF AUTOMATICALLY TURNING OFF ALL LIGHTS IN ROOM NO MORE THAN 30MINUTES AFTER THE AREA HAS BEEN VACATED.3. WALL MOUNTED WALL SWITCH / DIMMER, EQUAL TO ACUITY CONTROLS MODEL NO."SPODM-D" FOR AUTO ON / OFF, DIMMING OPERATION.4. CEILING MOUNTED OCCUPANCY DETECTOR. EQUAL TO ACUITY CONTROLS MODEL NO."CM 9". PROVIDE ALL RELAYS, POWER SUPPLIES, WIRING, ETC. AS REQUIRED TOPROVIDE MOTION CONTROLLED SWITCHING OF THE FIXTURES IN THIS ROOM; AND TOPROVIDE MANUALLY CONTROLLED DIMMING OR SWITCHING BY THE SWITCH AT THEDOOR.5. CONNECT TO EXISTING AREA LIGHTING CIRCUIT.6. RECONFIGURE RELOCATED LAY-IN LIGHT FIXTURES AND CONNECT TO EXISTING ROOMSWITCHED CIRCUIT.7. RELOCATED LAY-IN FLUORESCENT LIGHT FIXTURE. CLEAN AND RE-LAMP PRIOR TORE-INSTALLATION.8. RECONFIGURE ROOM LIGHTING CIRCUIT AS REQUIRED FOR NEW LIGHT FIXTURELAYOUT.9. NEW EXIT LIGHT TO MATCH BUILDING STANDARD. CONNECT TO EXISTING BUILDINGEMERGENCY LIGHTING CIRCUIT.10. RELOCATED EXIT LIGHT. CONNECT TO EXISTING BUILDING EMERGENCY LIGHTINGCIRCUIT.11. NEW WALL MOUNTED LIGHT SWITCH SERVES OPEN OFFICE AREA. EXTEND ANDCONNECT TO EXISTING FIXTURES SWITCHED CIRCUIT.12. CONTRACTOR IS TO PROVIDE ALL COST TO FIRE ALARM COMPANY TO PROVIDE ANDINSTALL NEW VISUAL ALARM STROBE IN LARGE CONFERENCE ROOM, PER AHJ.CURRENT FIRE ALARM SYSTEM TO BE MODIFIED TO ADD NEW DEVICE TO BUILDINGFIRE ALARM SYSTEM. FIRE ALARM CONTRACTOR TO BE APPROVED BY BUILDINGLANDLORD.13. WALL MOUNTED WALL SWITCH / DIMMER, EQUAL TO ACUITY CONTROLS MODEL NO."SPODM-D SA" FOR MANUAL ON / OFF, DIMMING OPERATION.NOTES INDICATED BY NUMBER IN :1111AAAAAAAAADMM 2234556777758876EE9109VOLTAGEREMARKSLAMP TYPEMTG.FIXTURE TYPEMANUFACTURER AND CAT. NO.LIGHTING FIXTURE SCHEDULEMARKANOTE 1LED3500K LED2X4 LAY-INWATTAGELITHONIA STAKS 2X4 AL06 SWW731.5NOTES:1. CONTRACTOR TO FIELD VERIFY AND MATCH BUILDING STANDARD.LIGHTING PLAN GENERAL NOTES:1. VERIFY EXACT CEILING CONSTRUCTION WITH ARCHITECTURAL REFLECTEDCEILING PLAN AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARYMOUNTING HARDWARE.2. ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIREDSTRUCTURAL SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED ISSUE OFTHE INTERNATIONAL BUILDING CODE, AS WELL AS ANY LOCAL CODES.3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGNCHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIESBETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL PLANSSHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TOORDERING EXIT SIGNS.4. MC CABLE IS NOT PERMITTED.5. VERIFY ALL DEVICES' LOCATION AND FINISH COLOR WITH ARCHITECT.6. MAINTAIN EXISTING LIGHTING CIRCUIT INTEGRITY IN AREAS NOT AFFECTED BYWORK OF THIS PROJECT.EMERGENCY LIGHTING NOTE:1. EMERGENCY CIRCUITS FROM LIFE SAFETY SYSTEM CURRENTLY SERVE LIFESAFETY LIGHTING FIXTURES. THESE CIRCUITS SHALL BE REUSED FOR LIFE SAFETYLIGHTING UNDER THIS PROJECT. UNDER NO CONDITIONS SHALL INDEPENDENTBATTERY PACK / INVERTER FIXTURES BE USED.(R)(R)(R)(R)(R)VNEW FIRE ALARMSTROBE12WELLNESS306MEDIUMCONF.305FOCUS324STORAGE323SMALLCONF.322SMALLCONF.321MEDIUMCONF.305LARGECONF.320OPEN OFFICEOPEN OFFICEOPEN OFFICELEVEL 3 FLOOR PLAN -ELECTRICAL LIGHTING,NEWD133 PERMIT & CONSTRUCTION04/21/2023 Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001E-4Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DNUPUPDN102103104105106107108109110111112113114115116117118119120121122123124125126127128134133132131130129138139137136135150140141142143144145146147148149151152153154155156157162163168167166165164161158159160172173174171170169178177176175LEVEL 3 FLOOR PLAN - ELECTRICAL POWER, NEWSCALE: 1/8" = 1'-0"NJPPPPPPPPPPPP(2)64"64"64"JDJPJPJPJJJPDDJPJDJDJPJPJDJPJDPPPPCR(2)J1. NEW POWER AND DATA CONNECTIONS FOR WALL MTD. MONITORS. EXTEND NEWPOWER CIRCUIT INDICATED TO EXISTING CIRCUITS MADE AVAILABLE BY DEMOLITIONWORK OF THIS PROJECT. REFER TO TYPICAL CONFERENCE ROOM ROUGH-IN - AVELEVATION DETAILS, SHEET E-5 AND A/V DRAWINGS FOR REQUIREMENTS.2. NEW 4"Ø CORE HOLE FLOOR PENETRATION IN EXISTING CONCRETE FLOOR.COORDINATE THE EXACT LOCATION OF CORE HOLE PRIOR TO STARTING WORK.INSTALL NEW MULTI SERVICE POWER / DATA SURFACE STYLE POKE THRU DEVICEEQUAL TO WIREMOLD RC3 SERIES CAT. NO. RC3ATCBK. DEVICE SHALL HAVE (1) ONE20A. DUPLEX RECEPTACLE AND (1) ONE COMMUNICATION DEVICE FOR DATACOMMUNICATION. DEVICE SHALL BE SUITABLE FOR USE ON CARPET FLOOR. FINISHCOLOR SHALL BE BLACK.3. REFER TO A/V DRAWINGS FOR NEW MONITOR AV AND DATA ROUGH-IN LOCATION.CONTRACTOR TO SUPPLY AND INSTALL 2-GANG X 2-1/4" DEEP J-BOX WITH PLASTERRING. INSTALL (1) 1-1/2" CONDUIT STUB UP WITH PULL STRING AND NYLON BUSHINGSFROM J- BOX TO 6" ABOVE CEILING. REFER TO A/V DRAWINGS FOR EXACT LOCATIONAND REQUIREMENTS.4. REUSE EXISTING POWER CIRCUIT MADE AVAILABLE BY DEMOLITION WORK OF THISPROJECT.5. EXTEND AND CONNECT TO EXISTING ROOM POWER CIRCUIT.6. NEW VERIZON CARD READER AT SINGLE DOOR. REFER TO DETAILS, SHEET E-5 FORREQUIREMENTS.7. FOR AV TOUCH PANEL (PROVIDED BY OTHERS): CONTRACTOR TO PROVIDE TWO GANGBOX 48" A.F.F., PROVIDE 1" CONDUIT TO ACCESSIBLE AREA ABOVE CEILING, PROVIDEWITH PULL STRING.8. EXISTING COMMUNICATIONS / DATA OUTLET MOUNTED ON WALL FOR DATACONNECTION TO TABLE THROUGH NEW SURFACE MTD. CABLE MANAGEMENT SYSTEMTO BE PROVIDED BY THIS CONTRACTOR. REFER TO ARCH. FOR SPECIFICATIONS.DATA CABLING BY OTHERS.9. NEW SURFACE MTD. CABLE MANAGEMENT SYSTEM SERVES CONFERENCE TABLEDATA / COMM. FEEDS., REFER TO ARCH. DRAWINGS FOR PRODUCT SPECIFICATIONS.10. PROVIDE 1-1/2" C. WITH PULL STRING UNDER FLOOR FOR AV CONNECTION BETWEENPOKE THRU AND WALL MOUNTED TV / MONITOR. REFER TO AV DRAWINGS FORREQUIREMENTS. PROVIDE A SEPARATE 3/4" C. FOR POWER BETWEEN POKE THRUAND WALL MOUNTED TV / MONITOR.NOTES INDICATED BY NUMBER IN :11F2VERIFY WITH ARCH. EXACTLOCATION OF RECEPTACLESPRIOR TO ROUGH-IN, TYPICALTHROUGHOUT33344554444WELLNESS306MEDIUMCONF.305FOCUS324STORAGE323SMALLCONF.322SMALLCONF.321MEDIUMCONF.305LARGECONF.320OPEN OFFICEOPEN OFFICEOPEN OFFICECR6CR6LEVEL 3 FLOOR PLAN -ELECTRICAL POWER,NEWJ7J7J7J7J78910J819J73 PERMIT & CONSTRUCTION04/21/2023 Sheet NumberOriginal drawing is 42 x 30. Do not scale contents of this drawing.Sheet TitleProject No:No. DescriptionDateCOPYRIGHT C 2023ABILENE, TEXASCONSULTING ENGINEERSWTA, INC.WTA - T-23001WTA T-23001E-5Professional SealsProjectKey Plan1VerizonIndianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaAll reproduction & intellectual property rights reserved © 2023717 North Harwood StreetSuite 3300, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.Prepared ForVERIZONIn Association with90% REVIEW SET03/31/20232 BID ISSUE SET04/07/2023DATA/IT OUTLET, MOUNTED 18" A.F.F. UNLESS OTHERWISEINDICATE THE NUMBER OF CONDUCTORSCONDUIT "HOME RUN" TO PANEL (HASH MARKSSYMBOLDESCRIPTIONDUPLEX RECEPTACLE - IN WALL +18" A.F.F. OR ASSPST WALL SWITCHJUNCTION BOX WITH COVERELECTRIC MOTOR JNOTED.ELECTRICAL SYMBOL LEGENDFFLOOR MOUNTED DUPLEX RECEPTACLEEMERGENCY EXIT LIGHTEDOUBLE DUPLEX RECEPTACLE, WALL MOUNTED AT+18" A.F.F. OR AS NOTED.NOTED.2x4 LED LIGHTING FIXTURE (TYPE "A")CEILING MOUNTEDADLIGHT CONTROL DIMMERINDICATED BY HATCHINGEXISTING ITEMS TO BE REMOVED ARE SECURITY SYSTEM CARD KEY READERCRAUDIO/VISUAL WALL MTD. OUTLET BOX, ALL MOUNTED 18" A.F.F.,WITH PULL STRING TO ABOVE CEILINGAVLARGER THAN PIPEPIPE SLEEVE TOBE 2 PIPE SIZESFIRE SEALANT, 3MFIREDAM 150CLASSIFIED PER ASTME814 (UL1479) ANDASTM E119 (UL263)WHERE REQUIRED FORFIRE RATED ASSEMBLYWALLSPECIFICATIONSEAL PERSCALE: NONEFOR NON-FIRE RATEDWALL ASSEMBLYOCCUPANCY SENSOR (CEILING MOUNTED)SINGLEGANG BOXRECESSEDTRIM PLATETP160 OR TP161DS 150iBACKPLATEFLEXIBLEMETALCONDUIT(IN WALL)TO 12"x12"JUNCTION BOX90 DEGREEFLEXIBLEMETALCONDUITCONNECTORMOUNTING DS 150i WITH TRIMPLATEON A SINGLE GANG RECESSED BOXMOUNTING DS 150i WITH BLANK3 GANG PLATE ON WIREMOLD SURFACE BOXMOUNTING DS 150i ON 12"x12"x6"JUNCTION BOX LOCATED ABOVE DOORDS 150i12"x12"x6"JUNCTION BOXTO 12"x12"JUNCTION BOXCONDUIT(SURFACE)SPECIFICATIONSCONDUIT AND WIRING TOACCESS SYSTEM CENTRALEQUIPMENT LOCATIONINPUT POWER: 12 OR 24 VDC OR AC; 35 mA @ 12 VDC; 38 mA @ 24 VDC; 38 mA AVG. @ 12 VAC, 45 mA AVG. @ 24 VAC.THE ENCLOSURE MEASUREMENTS ARE 1.50 in. H., BY 6.25 in. W., BY 1.50 in. D. (3.8 cm h., 15.8 cm W., 3.8 cm D.).USE RUBBER ORPLASTIC GROMMETAT WIRE ENTRANCETO JUNCTION BOX7"1 3/4"SST DS BACKBOXEMT CONNECTORDS 150IDETAIL - MD-03NO SCALEREX MOTION STANDARD MOUNTING42112346"5PLAN VIEWELEVATION6USE ONLY WHEN SPECIFIEDAND ELECTRIC STRIKE - 1D-02NO SCALESINGLE DOOR WITH CARD READERCARD READER, INDALA FLEXPASS LINEAR SERIESFAIL SECURE 24VDC ELECTRIC DOOR STRIKE - FOLGER ADAM MODEL 260,4REQUEST TO EXIT MOTION SENSOR, DETECTION SYSTEMS MODEL DS-150i13COMMENTSSELECT MODEL TO SUIT APPLICATIONDOOR MONITORING SWITCH, SENTROL MODEL 1076W (CONCEALED) ORSENTROL MODEL 2507A (SURFACE, TO BE MOUNTED ON SECURE SIDE OF DOOR)2SELECT MODEL TO SUIT APPLICATION300 OR 700 SERIES OR HES 960012" X 12" X 6" JUNCTION BOX5DEVICE NAME AND MANUFACTURER'S IDENTIFICATIONDEVICENO.SEE DETAIL MD-03LOCAL AUDIBLE ALARM DEVICE WHERE REQUIRED, VERIFY6SELECT MODEL TO SUIT APPLICATIONSELECT MODEL TO SUIT APPLICATIONGENERAL NOTES:1. ALL CONDUIT SHALL BE SIZED INACCORDANCE WITH THE NATIONALELECTRIC CODE.2. JUNCTION BOXES AND CONDUITS SHALLBE MOUNTED OR FASTENED ON THESECURE SIDE OF THE DOOR.3. BEST ENGINEERING JUDGEMENT SHALLBE UTILIZED IN APPLYING THESEDETAILS IN ORDER TO MEET THEDESIGN INTENT.4. ALL DIMENSIONS ARE APPROXIMATE.CONCEALED FLEXIBLECONDUITFINISHED CEILING(WHERE APPLICABLE)53CONDUIT AND WIRINGTO ACCESS SYSTEMCENTRAL EQUIPMENTLOCATION6SECURESIDENON-SECURESIDE3'-6" AFF1. LOCAL AUDIBLE SHALL SOUND WHEN DOOR IS OPENED WITHOUT VALID CARD READER OR REQUEST TO EXIT.2. LOCAL AUDIBLE SHALL SOUND WHEN DOOR IS HELD OPEN BEYOND PROGRAMMED TIME LIMIT.3. LOCAL AUDIBLE SHALL CEASE SOUNDING AFTER 60 SECONDS.4. LOCAL AUDIBLE SHALL BE BY-PASSABLE WITH LOCAL KEY SWITCH WHERE SPECIFIED, VERIFY.LOCAL ALARM SEQUENCE OF OPERATION:(VIEWED FROM NON-SECURED SIDE)1'-0"DUPLEX RECEPTACLE.REFER TO SPECIFICATIONS.TYPICAL.SINGLE GANGWALL BOX. TYPICAL.DUPLEX WALL PLATESCALE: NONERECEPTACLESWITCHLA - 1LA - 1CIRCUIT NUMBER,TYPICALVINYL APPLIEDCIRCUIT I.D. LABELSINGLE GANGWALL BOX. TYPICAL.SWITCH WALL PLATECOVER AND DEVICE PLATESSHALL BE ONE PIECE ANDSCREW FASTENED, TYP.LABEL OUTLETS ANDSWITCHES WITH PANEL ANDCIRCUIT SERVING OUTLETAND SWITCHESSCALE: NONEPARTITION WALLW/ GYPBOARDLC18" OR AS NOTED CEILING HEIGHTVARIES, VERIFY4-11/16" SQUAREJ-BOX WITH 3/4"KNOCKOUTSTRIM RING OR COVERPLATE AS REQUIREDTURN CONDUIT OUT INDIRECTION OF INTERIORCORRIDORPULL STRING IN 3/4"CONDUIT (OR ASNOTED OTHERWISE)INSULATED BUSHINGON END OF CONDUITCOMMUNICATIONSROUGH IN DETAILTYPICAL PIPE THRUWALL PENETRATIONTYPICAL DEVICEMOUNTING DETIALFDATA/IT AND POWER OUTLET BOX, FLOOR MOUNTED.MMOTION CONTROL LIGHT SWITCHELECTRICAL SYMBOLSLEGEND AND DETAILSRECCESSED BOXES (1-DUPLEX ELEC. & 1-DUALGANG DATA WITH PLASTERRING) BY THIS CONTRACTOR(1) 1-1/2" C. FROMBACKBOXES TO 6"ABOVE ACCESSIBLECEILING BY THISCONTRACTOR50" DISPLAY, MOUNTINGHARDWARE, & WEBEXMINI BY OTHERS(1) 1-1/2" C. BY THISCONTRACTOR(1) DUAL GANG WALLBOX WITH PLASTERRING BY THISCONTRACTORFINISHED FLOORCEILING LINEDUAL 65" DISPLAY,MOUNTING HARDWARE,& WEBEX BY OTHERSFINISHED FLOORCEILING LINERECCESSED BOXES (1- DUPLEXELEC. & 1- DUAL GANG DATA WITHPLASTER RING); TYP. FOR EA.MONITOR; BY THIS CONTRACTOR(1) 1-1/2" C. FROMBACKBOXES TO 6" ABOVEACCESSIBLE CEILING,(TYP. FOR EA. MONITOR)BY THIS CONTRACTOR(1) DUAL GANG WALLBOX WITH PLASTERRING BY THISCONTRACTORTERMINATE WITHINSULATEDBUSHINGTERMINATE WITHINSULATEDBUSHINGJJ-BOX BY THISCONTRACTORJRECCESSED BOXES (1- DUPLEXELEC. & 1- DUAL GANG DATA WITHPLASTER RING); TYP. FOR EA.MONITOR; BY THIS CONTRACTORTERMINATE WITHINSULATEDBUSHING, TYP.(1) 1-1/2" C. FROMBACKBOXES TO 6" ABOVEACCESSIBLE CEILING,(TYP. FOR EA. MONITOR)BY THIS CONTRACTORDUAL 98" DISPLAY,MOUNTING HARDWARE,& WEBEX BY OTHERSCEILING LINEJ-BOX BY THISCONTRACTOR(1) DUAL GANG WALLBOX WITH PLASTERRING BY THISCONTRACTOR(1) 1-1/2" C. FROM WALLBOX TO UNDERSIDE OFTABLE BY THISCONTRACTORFINISHED FLOORREFER TO ARCH. DWGS. FORFINISH AT TABLE (STUB-UP INTOFLOOR BOX FROM BELOW FLOOR)TYPICAL SMALL CONF. ROOMREFER TO A/V DRAWINGSFOR ROUGH-IN DIMENSIONSREFER TO A/V DRAWINGSFOR ROUGH-IN DIMENSIONSREFER TO A/V DRAWINGSFOR ROUGH-IN DIMENSIONSCOMBINATION DATA, A/V OUTLET BOX, WALL MTD.18" A.F.F. UNLESS OTHERWISE NOTEDSCALE: NONETYPICAL CONFERENCE ROOM - AV ELEVATION DETAILSTYPICAL MEDIUM CONF. ROOMTYPICAL LARGE CONF. ROOM3 PERMIT & CONSTRUCTION04/21/2023 01AV-001AUDIO VISUAL DRAWING LIST, GENERAL NOTES AND SYMBOLS02AV-103AUDIOVISUAL FLOOR PLAN - LEVEL 303AV-203AUDIOVISUAL CEILING PLAN - LEVEL 304AUDIO VISUAL ELEVATIONS ROOM 321 - SMALL CONFERENCE ROOM05AV-401AUDIO VISUAL ELEVATIONS ROOM 322 - SMALL CONFERENCE ROOM06AV-402AUDIO VISUAL ELEVATIONS ROOM 122 - MEDIUM CONFERENCE ROOM07AV-403AUDIO VISUAL ELEVATIONS ROOM 305 - MEDIUM CONFERENCE ROOM08AV-404AUDIO VISUAL ELEVATIONS ROOM 320 - EXTRA LARGE CONFERENCE ROOMDwgSeqDrawingNumberDrawingTitleVERIZONA U D I O V I S U A L S Y S T E M S D E S I G NI N S T R U C T I O N SINDIANAPOLIS, IN250 E 96TH STREETINDIANAPOLIS, IN 46240AV-405AUDIOVISUAL SYSTEM DIAGRAM - SMALL CONFERENCE ROOM - 321AUDIOVISUAL SYSTEM DIAGRAM - SMALL CONFERENCE ROOM - 322AUDIOVISUAL SYSTEM DIAGRAM - MEDIUM CONFERENCE ROOM - 122AUDIOVISUAL SYSTEM DIAGRAM - MEDIUM CONFERENCE ROOM - 305AUDIOVISUAL SYSTEM DIAGRAM - EXTRA LARGE CONFERENCE ROOM - 320AV-501AV-502AV-503AV-504AV-5050910111213ROOM RESERVATION INSTALLATION DETAIL FOR NAVIGATOR SOLUTIONAV-30114Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL DRAWINGLIST, GENERAL NOTESAV-001AND SYMBOLS DNUPP 47/24 E47/36 EP 47/24 E47/36 EP 47/24 E47/36 EPP P PI47/24 E47/36 E47/24 E47/36 E47/24 E47/36 EPI4 7 / 2 4 N 47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 E24x6024x6024x6024x6024x6024x60PP P PP P 4 7 / 2 4 N 47/24 N47/24 N47/24 N4 7 / 2 4 N 47/24 N47/24 N47/24 E24x6024x6024x6024x6024x6024x6047/24 N24x6024x6024x60 24x6047/24 N47/24 NPPPP47/36 E 47/24 E 47/36 E 47/24 E 24x6024x6024x6024x6024x6024x6047/24 E47/24 N4 7 / 2 4 N47/24 N47/24 N4 7 / 2 4 N 4 7 / 2 4 N 4 7 / 2 4 N PIPP P47/36 E47/24 EP 47/36 E47/24 EP47/36 E47/24 EP24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N4 7 / 2 4 N 47/24 N47/24 N47 / 2 4 N 4 7 / 2 4 N PIP P P 47/36 E47/24 EP 47/36 E47/24 EP 47/36 E47/24 EP20202525252525252520252020202020202020252020252525252525202525202567/ 4 8 N67/24 N67/30 N42/3D42/3D42/3D42/3D42/3D42/3D36/3D36/3DP P 67/42 E FSF F LT FS36/2DBBF30x6067/ 4 8 E 67/ 4 2 E 67/48 N67/36 N67/48 N67/42 E FSFFLT FS36/2DBBF30x6067/48 N67/36 N67/30 E67/42 E FSLT FS36/2D30x6067/48 E67/ 4 2 E 67/48 N36/3D67/30 N67/36 N67/42 ETL FS67/36 E67/36 E FSLT67/24 N24x6667/24 N67/24 N 39/24 N39/24 E39/24 EPP67/48 E36/2D67/36 E42/3D42/3D36/3D36/3D36/3D36/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D36/3D36/3D36/3D36/3D3 6 / 3 D 3 6 / 3 D 36/3D36/3D85/12 N85/24 N80/4885/24 N85/12 N FS 67/48 E67/30 NPI39/42 EPI PI67/24 N67/30 N67/30 N67/48 N67/48 E 67/42 E FS FFLT FS36/2DBBF 30x60 67/42 E67/24 N67/30 N67/30 N67/48 N67/48 E 67/42 E FS FFLT FS36/2DBBF 30x60 67/42 EPI67/30 N67/30 N67/48 N67/48 E 67/42 E FS FFLT FS36/2DBBF 30x60 67/42 EPI PIPI FSFF L T FS 36/2DBBF30x6067/24 N67/30 N FSFFLT FS36/2DBBF30x6067/24 N 67/48 E67/42 E67/30 N 67/42 E67/48 N67/42 E67/48 N67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 E67/42 E67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 E67/42 E67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/48 E67/42 E67/48 N67/30 N 85/42 N85/42 N85/48 N85/48 N85/48 N85/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/30 N FSFFLT FS36/2DBBF30x6067/24 N 67/48 E67/42 E67/30 N 67/42 E67/48 N67/42 E67/48 NLT FS36/2D BBF67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 E67/42 E67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 E67/42 E67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 E67/42 E67/48 N67/30 N 39/42 E39/48 E FS FSLT67/36 N67/48 NFF36/2DBBF30x6039/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E FS FS FS FS FS FS FS FSFFLT36/2DBBF30x6067/24 N67/30 N67/42 E FSFFLT36/2DBBF30x606 7 / 2 4 N67/48 N67/30 N67/42 E67/48 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT36/2DBBF30x606 7 / 2 4 N67/48 N67/30 N67/42 E FSFFLT36/2DBBF6 7 / 2 4 N 67/48 N67/30 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N FSFFLT FS36/2DBBF30x6067/24 N67/30 N FSFFLT FS 36/2DBBF30x6067/24 N67/ 4 8 E67/42 E67/30 N67/42 E67/48 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/ 3 0 N 67/42 E FSF F L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFF36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFL T FS 36/2DBBF30x6067/24 N67/ 4 8 E 67/ 4 2 E67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSF F LT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/ 4 8 E 67/ 4 2 E 67/48 N67/30 NPP67/42 E FS FFLT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/48 E67/42 E67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/ 4 8 N 67/30 N67/42 E FSFFLT FS36/2DBBF30 x 6 0 67/24 N67/48 E67/42 E67/48 N67/30 N67/ 4 2 E FS FFLT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSFF36/2DBBF30x6067/24 N67/48 N67/48 E67/42 E67/48 N67/42 E FS FFLT FS36/2DB B F30x60 67/24 N67/48 N67/30 N67/ 4 2 E FS FFLT FS36/2DBBF3 0 x 6 0 67/24 N67/48 E67/42 E67/ 4 8 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/ 4 8 N 67/30 N67/42 E FSFFLT FS36/2DB B F 3 0 x 6 0 67/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FS FFLT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E F S LT FSBBF3 0 x 6 0 67/48 E67/42 E67/48 N67/30 N36/2D36/2DCRDRRRRR R RR RRLARGE CONF.320MEDIUM CONF.122BREAK ROOM302MEDIUM CONF.305FOCUS324STORAGE323SMALL CONF.322SMALL CONF.321OPEN OFFICEOPEN OFFICEOPEN OFFICEIDF304WELLNESS3061AUDIOVISUAL FLOOR PLANRRSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL FLOORPLANAV-103LEVEL 3TWO (2) WALL MOUNTED 98"SAMSUNG DISPLAYS WITHARTICULATING WALLMOUNTSCISCO WEBEX SPEAKERTRACK 60 WALL MOUNTBELOW DISPLAYSTWO (2) WALL MOUNTED 55"SAMSUNG DISPLAYS WITHLOW PROFILE WALL MOUNTSCISCO WEBEX ROOM KITCAMERA WALL MOUNTBELOW DISPLAYSONE (1) WALL MOUNTED 50"SAMSUNG DISPLAY WITHLOW PROFILE WALL MOUNTCISCO WEBEX ROOM BARCAMERA WALL MOUNTABOVE DISPLAYCISCO WEBEX TOUCH 10TOUCH PANELCISCO WEBEX TOUCH 10TOUCH PANELCISCO WEBEX TOUCH 10TOUCH PANELONE (1) WALL MOUNTED 50"SAMSUNG DISPLAY WITHLOW PROFILE WALL MOUNTCISCO WEBEX ROOM BARCAMERA WALL MOUNTABOVE DISPLAYSCISCO WEBEX TOUCH 10TOUCH PANELTWO (2) WALL MOUNTED 65"SAMSUNG DISPLAYS WITHLOW PROFILE WALL MOUNTSCISCO WEBEX TABLEMICROPHONECISCO WEBEX TABLEMICROPHONECISCO WEBEX TOUCH 10TOUCH PANELCISCO WEBEX ROOM KITCAMERA WALL MOUNTBELOW DISPLAYSTHREE (3) CISCO WEBEXTABLE MICROPHONES DNUPLARGE CONF.320MEDIUM CONF.122SMALL CONF.321SMALL CONF.322STORAGE323FOCUS324MEDIUM CONF.305BREAK ROOM302RR101R1021AUDIOVISUAL CEILING PLANOCSOCSOCSOCSOCSOCSOCSSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL CEILINGPLANAV-203LEVEL 3EIGHT (8) CEILING MOUNTED6.5" JBL SPEAKERSOCCUPANCY SENSOROCCUPANCY SENSOROCCUPANCY SENSOROCCUPANCY SENSOROCCUPANCY SENSOROCCUPANCY SENSOROCCUPANCY SENSOR FINISHED CEILINGGLASS - DOOR FRAME CUTOUT WITH GROMMETREQUIRED. CABLE ACCESS THROUGH EITHER SIDE.PROVIDE PULL STRINGGENERAL NOTES:FILM ON GLASS BEHIND BRACKETPROVIDED BY OTHERS.A SINGLE 30 FT CORD CUT IN HALF AND IS USEDFOR TWO (2) NAVIGATORS. RJ-45 END ATNAVIGATOR.CISCO NAVIGATOR WALL VERSION148 PART NUMBERPROCURED BYINSTALLED BYCISCOCS-T10-WM-K9=ATSGAV CONTRACTOR2VzSensorVERIZON OCCUPANCY SENSOR (MICRO USB)3VERIZONVZ-SENSORVERIZON WIFI GATEWAY (PoE)4VERIZONVZ-GATEWAYVERIZON WIFI RELAY (MICRO USB)5VERIZONVZ-RELAYPoE SPLITTER WITH MICRO-USB PLUG - ISOLATED 12W - 5V 2.4AMP6aVIGITRONVi00103RX25FT CAT6 ETHERNET NETWORK PATCH CABLE - BLACK7nFLEXONSURFACE MOUNT BOX W/ DATA JACK8SMKYSJWH01P0CATEGORY 6 UTP KEYSTONE JACK - WHITE9KJCT06WH001030FT THIN PATCH CORD - BLACK101 FT CAT6 ETHERNET NETWORK PATCH CABLE - BLACK1112CAT6 CABLE, IDF PATCH PANEL/PATCH CORDS BYLOW VOLTAGE (LV) CONTRACTOR.AV CONTRACTORAV CONTRACTORAV CONTRACTORAV CONTRACTORAV CONTRACTORAV CONTRACTORLV CONTRACTORLV CONTRACTORAV CONTRACTORAV CONTRACTORAV CONTRACTORVzSensorVzSensorADAFRUIT3785INSIGHTVIGITRON Vi00103 NETMUX ETHERNET PoE PORT MULTIPLEXER (COMBINER)INSIGHT6bVIGITRONVi00103TXAV CONTRACTORVIGITRON Vi00103 NETMUX ETHERNET PoE PORT MULTIPLEXER (SPLITTER)INSIGHTnFLEXONnFLEXONnFLEXONnFLEXONnFLEXON3 FT CAT6 ETHERNET NETWORK PATCH CABLE - BLACKOWNERnFLEXONnFLEXONnFLEXONnFLEXONnFLEXONnFLEXONVERIZONVERIZONVERIZONVERIZONAV CONTRACTORAV CONTRACTORAV CONTRACTORLV CONTRACTORLV CONTRACTORAV CONTRACTORAV CONTRACTORAV CONTRACTORAV CONTRACTORA.B.C.D.A1A148 RGOSOS5979125911812101076b1195986aROOM W/ WEBEXRESERVABLE ROOMW/O WEBEXOPEN AREANON RESERVABLE ROOMSWITCHPATCH PANELIDFMANUFACTURERITEM NO.DESCRIPTIONLOW VOLTAGE CONTRACTOR TO INSTALL SURFACEMOUNT NEAR DOOR IN ENCLOSED ROOMS.E.PC06UPBK0250PC06UPBK0300PC06UPBK0010PC06UPBK0030LV CONTRACTORnFLEXONnFLEXONLV CONTRACTORDATA DROP PRICE BYVENDOR13CAT6 ETHERNET CABLE FROM NEAREST IDF AND CEILING DATA JACKCAT6 CABLECAT6 CABLECAT6 CABLECAT6 CABLECAT6 CABLESheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONROOM RESERVATIONINSTALLATION DETAILFOR NAVIGATOR SOLUTIONAV-301 Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL ELEVATIONSROOM 321 - SMALLCONFERENCE ROOMAV-401ONE (1) DUAL GANG WITH PLASTERRING BY GCWALL MOUNTED UPS WITHMOUNTING BRACKETONE (1) WALL MOUNTED 50"DIAG. DISPLAYDISPLAY WALL MOUNT BRACKETASSEMBLYCISCO WEBEX ROOM BARCAMERA WALL MOUNT ABOVEDISPLAYPLYWOOD BACKINGWALL REINFORCEMENT BY GCRECESSED BOXES. DUPLEX ELEC, GANG DATA WITH PLASTER RING BY GCONE (1) 1 12" CONDUITFROM BACKBOXES TO ABOVEACCESIBLE CEILING BY GC Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL ELEVATIONSROOM 322 - SMALLCONFERENCE ROOMAV-402ONE (1) DUAL GANG WITH PLASTERRING BY GCWALL MOUNTED UPS WITHMOUNTING BRACKETONE (1) WALL MOUNTED 50"DIAG. DISPLAYDISPLAY WALL MOUNT BRACKETASSEMBLYCISCO WEBEX ROOM BARCAMERA WALL MOUNT ABOVEDISPLAYPLYWOOD BACKINGWALL REINFORCEMENT BY GCRECESSED BOXES. DUPLEX ELEC, GANG DATA WITH PLASTER RING BY GCONE (1) 1 12" CONDUITFROM BACKBOXES TO ABOVEACCESIBLE CEILING BY GC 1ELEVATION 1Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL ELEVATIONSROOM 122 - MEDIUMCONFERENCE ROOMAV-403TWO (2) WALL MOUNTED 55"DIAG. DISPLAYSTWO (2) 1 12" CONDUITFROM BACKBOXES TO ABOVEACCESIBLE CEILING BY GCPLYWOOD WALL BACKINGREINFORCEMENTWALL MOUNTED UPS WITHMOUNTING BRACKETRECESSED BOXES. DUPLEX ELEC,DUAL GANG DATA WITH PLASTERRING BY GCARCHITECT TO PROVIDE FINISH ATTABLE (STUB-U FROM FLOORBELOW)WALL MOUNTED CISCO WEBEX KITCAMERADISPLAY WALL MOUNT BRACKETASSEMBLY2 GANG BOX BY 2-1/4" DEEP WITHCOVER AND 1-1/2" CONDUITS(BETWEEN ALL BACK BOXES)2 GANG BOX x 2-1/414" DEEP WITHPLASTER RING AND 1-1/2" CONTINUOSCONDUIT TO UNDERSIDE OF TABLERECESSED BOXES. DUPLEX ELEC,DUAL GANG DATA WITH PLASTERRING BY GC 1ELEVATION 1Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL ELEVATIONSROOM 305 - MEDIUMCONFERENCE ROOMAV-404TWO (2) WALL MOUNTED 65"DIAG. DISPLAYSTWO (2) 1 12" CONDUITFROM BACKBOXES TO ABOVEACCESIBLE CEILING BY GCPLYWOOD WALL BACKINGREINFORCEMENTWALL MOUNTED UPS WITHMOUNTING BRACKETRECESSED BOXES. DUPLEX ELEC,DUAL GANG DATA WITH PLASTERRING BY GCARCHITECT TO PROVIDE FINISH ATTABLE (STUB-U FROM FLOORBELOW)WALL MOUNTED CISCO WEBEX KITCAMERADISPLAY WALL MOUNT BRACKETASSEMBLY2 GANG BOX BY 2-1/4" DEEP WITHCOVER AND 1-1/2" CONDUITS(BETWEEN ALL BACK BOXES)2 GANG BOX x 2-1/414" DEEP WITHPLASTER RING AND 1-1/2"CONTINUOS CONDUIT TOUNDERSIDE OF TABLERECESSED BOXES. DUPLEX ELEC,DUAL GANG DATA WITH PLASTERRING BY GC 1ELEVATION 1Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL ELEVATIONSROOM 320 - EXTRA LARGEAV-405CONFERENCE ROOMPLYWOOD WALL BACKINGREINFORCEMENTTWO (2) WALL MOUNTED 98"DIAG. DISPLAYS TWO (2) 1 14" CONDUIT FROM BOX TO6" ABOVE ACCESIBLE CEILINGARCHITECT TO PROVIDE FINISH ATTABLE (STUB-U FROM FLOORBELOW)POWER AMPLIFIER MOUNTED TOWALLCISCO WEBEX PRO CODECWALL MOUNTED UPS WITHMOUNTING BRACKETCISCO WEBEX SPEAKERTRACKCAMERADISPLAY WALL MOUNT BRACKETASSEMBLY2 GANG BOX x 2-1/414" DEEP WITH PLASTERRING AND1-1/2" CONTINUOS CONDUIT TOUNDERSIDE OF TABLE2 GANG BOX BY 2-1/4" DEEP WITHCOVER AND 1-1/2" CONDUITS(BETWEEN ALL BACK BOXES)RECESSED BOXES. DUPLEX ELEC,DUAL GANG DATA WITH PLASTERRING BY GCRECESSED BOXES.DUPLEX ELEC,DUAL GANG DATA WITH PLASTERRING BY GC DC INHDMI INHDMIUSB 1USB-CHDMI OUT 1HDMIHDMI OUT 2HDMIMIC IN 1JACKLAN 1RJ-45LAN 2RJ-45SAMSUNGDISPLAYSCR321/DISP-01QM50RHDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-103P-104RS-232CTBCISCOTOUCH PANELSCR321/TP-01TOUCH 10COMMERCIAL ELECTRICPOWER STRIPSCR321/PS-01YLPT-43POWER 1POWER 2POWER 3POWER 4POWER 5POWER 6P-103APCUPSSCR321/UPS-01SCL500RM1UCAC INAC OUT 1AC OUT 2AC OUT 3AC OUT 4AC INP-101MAINS POWERP-102NETWORKRJ-45CLIENT LANN-104P-103SCR321 - TABLE TOPSCR321 - FRONT WALLCLIENT LANN-102V-101P-104SCR321/PS-01USB 2USB-ACISCOCODECSCR321/COD-01WEBEX ROOM BARSCR321/PS-01TO SCR321/COD-01TO SCR321/DISP-01LANRJ-45CLIENT LANN-101Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL SYSTEMDIAGRAM - SMALLCONFERENCE ROOM - 321AV-501 DC INHDMI INHDMIUSB 1USB-CHDMI OUT 1HDMIHDMI OUT 2HDMIMIC IN 1JACKLAN 1RJ-45LAN 2RJ-45SAMSUNGDISPLAYSCR322/DISP-01QM50RHDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-203P-204RS-232CTBCISCOTOUCH PANELSCR322/TP-01TOUCH 10COMMERCIAL ELECTRICPOWER STRIPSCR322/PS-01YLPT-43POWER 1POWER 2POWER 3POWER 4POWER 5POWER 6P-203APCUPSSCR322/UPS-01SCL500RM1UCAC INAC OUT 1AC OUT 2AC OUT 3AC OUT 4AC INP-201MAINS POWERP-202NETWORKRJ-45CLIENT LANN-204P-203SCR322 - TABLE TOPSCR322 - FRONT WALLCLIENT LANN-202V-201P-204SCR322/PS-01USB 2USB-ACISCOCODECSCR322/COD-01WEBEX ROOM BARSCR322/PS-01TO SCR322/COD-01TO SCR322/DISP-01LANRJ-45CLIENT LANN-201Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL SYSTEMDIAGRAM - SMALLCONFERENCE ROOM - 322AV-502 CAB-MIC-EXT-J=CISCOMICROPHONEMCR122/MIC-01MICROPHONEMIC OUTCISCOCODECMCR122/COD-01WEBEX ROOM KITDC INHDMI INHDMIUSB 1USB-AHDMI OUT 1HDMIHDMI OUT 2HDMIMIC IN 1JACKLAN 1RJ-45LAN 2RJ-45SAMSUNGDISPLAYMCR122/DISP-01QM55RHDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-303P-304RS-232CTBCISCOTOUCH PANELMCR122/TP-01TOUCH 10COMMERCIAL ELECTRICPOWER STRIPMCR122/PS-01YLPT-43POWER 1POWER 2POWER 3POWER 4POWER 5POWER 6P-303APCUPSMCR122/UPS-01SCL500RM1UCAC INAC OUT 1AC OUT 2AC OUT 3AC OUT 4AC INP-301MAINS POWERP-302NETWORKRJ-45CLIENT LANN-305P-303MCR122 - TABLE TOPMCR122 - FRONT WALLCLIENT LANN-302V-301P-304USB 2MICRO-USBTO MCR122/COD-01TO MCR122/DISP-01V-302HDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-304P-305RS-232CTBMCR122/PS-01SAMSUNGDISPLAYMCR122/DISP-02QM55RP-305TO MCR122/DISP-02AUDIO OUTJACKMIC IN 2JACKA-301MCR122/PS-01MCR122/PS-01LANRJ-45CLIENT LANN-301Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL SYSTEMDIAGRAM - MEDIUMCONFERENCE ROOM - 122AV-503 CAB-MIC-EXT-J=CISCOMICROPHONEMCR305/MIC-01MICROPHONEMIC OUTCISCOCODECMCR305/COD-01WEBEX ROOM KITDC INHDMI INHDMIUSB 1USB-AHDMI OUT 1HDMIHDMI OUT 2HDMIMIC IN 1JACKLAN 1RJ-45LAN 2RJ-45SAMSUNGDISPLAYMCR305/DISP-01QM65RHDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-403P-404RS-232CTBCISCOTOUCH PANELMCR305/TP-01TOUCH 10LANRJ-45COMMERCIAL ELECTRICPOWER STRIPMCR305/PS-01YLPT-43POWER 1POWER 2POWER 3POWER 4POWER 5POWER 6P-403APCUPSMCR305/UPS-01SCL500RM1UCAC INAC OUT 1AC OUT 2AC OUT 3AC OUT 4AC INP-401MAINS POWERP-402NETWORKRJ-45CLIENT LANN-405P-403MCR305 - TABLE TOPMCR305 - FRONT WALLCLIENT LANN-402V-401P-404USB 2MICRO-USBTO MCR305/COD-01TO MCR305/DISP-01V-402HDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-404P-405RS-232CTBSAMSUNGDISPLAYMCR305/DISP-02QM65RP-405TO MCR305/DISP-02AUDIO OUTJACKMIC IN 2JACKA-401MCR305/PS-01MCR305/PS-01MCR305/PS-01CLIENT LANN-401Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL SYSTEMDIAGRAM - MEDIUMCONFERENCE ROOM - 305AV-504 CISCOPTZ CAMERAXLC320/CAM-01SPEAKERTRACK 60HDMI OUT 1HDMIHDMI OUT 2HDMILAN 1RJ-45LAN 2RJ-45LAN 3RJ-45CISCOCODECXLC320/COD-01WEBEX PROHDMI OUT 1HDMIHDMI IN 1HDMIHDMI IN 2HDMIHDMI IN 3HDMIHDMI IN 4HDMIHDMI IN 5HDMILAN 1RJ-45LAN 2RJ-45LAN 3RJ-45LAN 4RJ-45LAN 5RJ-45MIC/LINE IN 1PHXMIC/LINE IN 2PHXMIC/LINE IN 3PHXMIC/LINE IN 4PHXMIC/LINE IN 5PHXMIC/LINE IN 6PHXMIC/LINE IN 7PHXMIC/LINE IN 8PHXHDMI OUT 2HDMIHDMI OUT 3HDMILINE OUT 1PHXLINE OUT 2PHXLINE OUT 3PHXLINE OUT 4PHXLINE OUT 5PHXLINE OUT 6PHXAC INCOMTBCISCOTOUCH PANELLCR/TP-01TOUCH 10LANRJ-45AC INCLIENT LANN-502JBL/HARMANAMPLIFIERXLC320/AMP-01CSA180Z-U-USAMP OUTTBINPUT 1TBAC INLANRJ-45OFE LANN-506P-503HDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-504P-504RS-232CTBSAMSUNGDISPLAYXLC320/DISP-01QM98FHDMI IN 1HDMIHDMI IN 2HDMILANRJ-45AC INCLIENT LANN-505P-506RS-232CTBSAMSUNGDISPLAYXLC320/DISP-02QM98F#1SPEAKERTAP:7.5W#2SPEAKER#3SPEAKER#4#5SPEAKER#6SPEAKERS-504S-503S-502S-501S-505S-506#7SPEAKER#8SPEAKERS-507S-508SPEAKERTAP:7.5WTAP:7.5WTAP:7.5WTAP:7.5WTAP:7.5WTAP:7.5WTAP:7.5WXLC320 - CEILINGXLC320 - FRONT WALLXLC320 - TABLE TOPP-507XLC320/UPS-02P-503APCUPSXLC320/UPS-01SCL500RM1UCAC INAC OUT 1AC OUT 2AC OUT 3AC OUT 4P-501MAINS POWERNETWORKRJ-45CLIENT LANN-507P-504TO XLC320/COD-01TO XLC320/DISP-01P-506TO XLC320/DISP-02P-507TO XLC320/AMP-01P-502P-502TO XLC320/CAM-01XLC320/UPS-01V-502V-501V-503V-504A-501A-502A-504N-503APCUPSXLC320/UPS-02SCL500RM1UCAC INAC OUT 1AC OUT 2AC OUT 3AC OUT 4P-505MAINS POWERNETWORKRJ-45CLIENT LANN-508XLC320/UPS-01XLC320/UPS-02XLC320/UPS-01CLIENT LANN-501CISCOTABLE MICROPHONEXLC320/MIC-01TABLE MICROPHONEAUDIO OUTCISCOTABLE MICROPHONEXLC320/MIC-02TABLE MICROPHONEAUDIO OUTCISCOTABLE MICROPHONEXLC320/MIC-03TABLE MICROPHONEAUDIO OUTA-503Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved © 2022No.DescriptionDatePrepared ForProject No:INDIANAPOLISDOWNSIZING250 E 96TH STREETIndianapolis, IN 46240VERIZON22.09612.0004/05/2023LOW VOLTAGE ENGINEER (AV/IT/SEC)1220G Airport Freeway, #418Bedford, TX 76022Tel 347.751.4453Dallas, TX, 75201, USAt+1 214 720 6000f+1 214 720 6005717 North Harwood StreetHellmuth, Obata & Kassabaum, L.P.Suite 3300, LB8ISSUED FOR BID04/21/2023ISSUED FOR PERMIT & CONSTRUCTIONAUDIOVISUAL SYSTEMDIAGRAM - EXTRA LARGECONFERENCE ROOM - 320AV-505 Issued for Bid04/07/2023OSAVMRRAVIssued for Permit and Construction04/21/2023Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.COMMUNICATIONSNOTES, SYMBOLS ANDDRAWING LISTTC-0011Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 DNUPP47/24 E47/36 EP47/24 E47/36 EP47/24 E47/36 EPPPPI47/24 E47/36 E47/24 E47/36 E47/24 E47/36 EPI47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N4 7 / 2 4 E 24x6024x6024x6024x6024x6024x60PPPPPP47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N4 7 / 2 4 E 24x6024x6024x6024x6024x6024x6047/24 N24x60 24x6024x6024x6047/24 N47/24 NPPPP47/36 E47/24 E47/36 E47/24 E24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 NPIPPP47/36 E47/24 EP47/36 E47/24 EP47/36 E47/24 EP24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 NPIPPP47/36 E47/24 EP47/36 E47/24 EP47/36 E47/24 EP20202525252525252520252020202020202020252020252525252525202525202567/48 N67 / 2 4 N 67/ 3 0 N 42/3D4 2 / 3 D 42/3D42/3D42/3D42/3D3 6 / 3 D 36/3DPP67/42 E FSFFLT FS36/2DBBF30x6067/48 E67/42 E67/48 N67/36 N67/48 N67/42 E FSF F L T F S 36/2DBBF30x6067/48 N67/ 3 6 N 67/30 E67/42 E FSLT FS36/2D30x6067/48 E67/42 E67/48 N36/3D67/30 N67/36 N67/ 4 2 E TL FS67/36 E67/36 E FSL T 67/24 N24x6667/24 N 67/24 N39/24 N39/24 E39/24 EPP67/48 E36/2D67/36 E 42/3D42/3D36/3D36/3D3 6 / 3 D 3 6 / 3 D 42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D36/3D36/3D3 6 / 3 D 3 6 / 3 D 36/3D36/3D36/3D36/3D85/12 N 85/24 N80/4885/24 N 85/12 N FS67/48 E67/30 NPI39/42 EPIPI67/24 N 67/30 N 67/30 N67/48 N67/48 E67/42 E FSFFLT FS36/2DBBF30x6067/42 E67/24 N67/30 N 67/30 N67/48 N67/48 E67/42 E FSFFLT FS36/2DBBF30x6067/42 EPI 67/30 N 67/30 N67/48 N67/48 E67/42 E FSFFLT FS36/2DBBF30x6067/42 EPIPIPI FSFFLT FS36/2DBBF30x6067/24 N67/30 N FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/30 N67/42 E67/48 N67/42 E67/48 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/48 E67/42 E 67/48 N67/30 N85/42 N85/42 N85/48 N85/48 N85/48 N85/42 E FSFFLT FS36/2DBBF30x6067/24 N67/30 N FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/30 N67/42 E67/48 N67/42 E67/48 NLT FS36/2DBBF67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N39/42 E39/ 4 8 E FS FSLT67/36 N67/48 NF F 36/2DBBF30x6039/42 E39/48 E39/42 E39/48 E39/ 4 2 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E FS FS FS FS FS FS FS FSF F LT36/2DBBF30x6067/24 N67/30 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E67/48 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSF F LT36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT36/2DBBF67/24 N67/48 N67/30 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N FSF F L T FS 36/2DBBF30x6067/24 N67/30 N FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/ 3 0 N67/42 E67/48 N67/42 E FSF F LT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSF F 36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSF F LT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067 / 2 4 N 67/48 N67/42 N67/48 E67/42 E67/48 N67/ 3 0 N PP67/42 E FSFFLT FS3 6 / 2 D BBF30x6067/24 N67/48 N67/30 N67/48 E67/42 E67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/ 4 8 N 67/42 N67/48 N67/30 N67/42 E FS FF36/2DB B F30x60 67/24 N67/48 N67/48 E67/42 E67/48 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSLT FSBBF30x6067/48 E67/42 E67/48 N67/30 N36/2D36/2DLARGE CONF.320MEDIUM CONF.122BREAK ROOM302MEDIUM CONF.305FOCUS324STORAGE323SMALL CONF.322SMALL CONF.321OPEN OFFICEOPEN OFFICEOPEN OFFICEIDF304WELLNESS306102103104105106107108109110111112113114115116117118119120121122123124125126127128134133132131130129138139137136135150140141142143144145146147148149151152153154155156157162163168167166165164161158159160172173174171170169178177176175AVRRRRRRRRRRRRAVAV AVAV AVAV AV0/3AV0/2REFER TO DRAWING TC.401FOR MORE INFORMATION 3/0 4/0 4/0 2/00/101-305:A01-305:B01-305:C01-305:D01-305:E01-305:F01-305:G 0/201-324:A 2/0 3/0 0/40/101-322:A01-322:B01-322:C01-322:D 3/0 0/40/101-321:C01-321:B01-321:A01-306:A01-306:BN 0/20/1 0/2 0/3 2/0 3/001-122:C01-122:D01-122:E01-122:A01-122:B0/1 0/3 0/2 0/20/101-320:A01-320:B01-320:C01-320:DSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.COMMUNICATIONSLEVEL 3 FLOOR PLANTC-1031Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 85/12 N 67/36 E 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 85/24 N 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T FF FF FF FF 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/42 E 67/48 E S F 24x60 BBF BBF FF FF FF FF 24x60 L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/30 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/48 E67/42 ES F30x60BBFBBF67/48 ES F30x60BBF67/42 E67/48 ES F30x60BBF67/42 E67/48 ES F30x6067/42 E67/24 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 NS FL TS FL TS FL TS FL T24x60BBFFFFFFFFF24x60BBF67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N42/3D42/3DS FL TS FL TS FL TS F36/2DFFFFFF42/3D42/3D42/3DCONF85/12 NS FL TS F30x60FFBBFS F30x60BBFBBF80/48S F30x60S F30x60BBF67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/42 E67/48 NS FL T30x60FFBBF30x60BBFBBF30x6030x60BBF67/48 NS F30x60FFBBF67/42 E67/42 E67/48 NS F30x60BBFBBF67/48 NS F30x6067/42 E67/42 E67/48 NS F30x60BBF42/3DFF67/42 ES FL TS FS FS FS F67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 EBBF30x6030x60BBFBBF30x6067/42 E67/48 NS FL T67/48 NS F67/42 E67/42 E67/48 NS F67/48 NS F67/42 E67/24 N42/3D42/3D42/3D36/3D36/3DSTAIRSRESTROOMRESTROOMELEVELEVSTAIRSELEVOFFICEOFFICECONFOFFICEOFFICEPLOTTEROFFICEOFFICECONFCONFCONF85/48 N85/42 N85/42 N85/48 N39/24 E39/24 N39/24 E36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2DS FBBFL T24x6636/2D36/2D36/2D42/3D42/3D39/48 E39/42 E39/48 E39/48 E39/42 E39/42 E39/42 E39/42 E39/48 E39/48 E39/42 E39/42 E39/48 EFFFF39/42 E39/48 EFFFF67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/24 N67/30 N67/30 N67/30 N36/3D67/24 N67/24 NF36/3DS FTTFL TS FTLFL TFFFFFFFFFFFFFF67/42 EBBF30x6067/48 N67/42 N67/36 E67/48 N67/42 N67/48 NS36/2D36/2D36/3D36/3D36/2D36/2D36/3D36/2D36/2D67/48 E67/42 E36/3D36/3D36/2DFF36/2D36/2DF85/42 E85/48 N F30x60L TF67/42 EFBBF67/48 NBBF30x60S FSL TF67/42 ES F67/48 N67/42 EF30x60BBF30x60L TBBF S67/48 N 67/42 EF67/42 EF67/42 ES67/48 N 67/48 NF30x6030x60BBFF67/36 NBBFF67/48 N67/48 N SFL T67/42 EBBFBBFF30x60F67/42 EF67/42 E30x60SFL TBBFF BBF30x60F30x60BBF 67/48 N67/48 N67/42 E67/48 NFFFF TFFL T30x60BBFF30x60S67/48 NS67/42 E 67/42 E67/24 N 67/24 N67/30 NLS 30x6067/42 E S 67/48 N67/36 E67/24 N 67/42 E67/48 N67/48 NS67/42 E 36/2D30x6036/2D 67/48 E67/30 N 67/30 N67/30 N67/24 N BBF 67/30 N BBF24x6024x60BBF24x60FF67/42 EBBFF 67/48 NBBF SSL T67/42 EBBFF30x60 BBF 24x60BBFBBF24x60 BBFFBBF F30x60 24x6024x60FFFFF 30x60SS67/42 E67/48 NSL TSL TS FL T67/48 N BBF24x 60 BBF 24x6 0 5S67/42 EF67/48 NSBBF30x60 24x6024x6024x6 0 BBFBBFBBF 24x6 0 BBF BBFBBF24x6024x6067/30 N67/30 N67/24 N67/24 N67/30 N 67/24 N 67/48 N67/42 N67/42 N 67/48 N67/48 N 67/42 N36/2D 36/2D36/2D 24x6024x6 0 24x6 0 BBF 24x60BBFBBF 24x60BBFBBF67/42 E67/48 EF L T67/42 E 67/48 EFL T67/42 E67/48 EFS F36/2DFF36/2DBBFFFBBFFLF BBF24x6030x6036/2D 67/24 N 36/2D36/2D 67/30 N BBF BBF 24x60BBF24x6024x6067/24 N67/30 N67/24 N 67/30 N 67/42 E36/2D 67/42 E 67/48 E67/48 ES 36/3D 36/3D FFFFFT67/42 ES F L T67/48 E36/2D36/2D 36/2D36/2D36/2DF36/2D30x60BBF 36/2D 36/2D36/2DF F67/42 E67/42 EBBFBBF30x6067/48 N67/48 NF30x60F67/42 E67/42 E67/42 E67/48 N67/48 N67/48 N67/24 N30x6030x6030x6067/48 NS67/48 NBBFSFBBF67/42 E67/42 E67/42 EBBFBBFFS67/48 N67/48 N30x6030x60F67/48 N67/42 E67/48 N67/48 NF67/42 EF67/48 NBBFS F30x60BBF36/3D36/3D30x6036/3D67/42 E36/2DBBFBBF30x6036/3D67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/30 N67/24 N67/30 NFF67/24 N67/48 E67/48 E67/30 N67/48 E67/42 E67/42 ESL TSSLS FL T67/42 E67/48 EFL67/42 ESLFFFF67/42 E67/42 E67/48 E67/48 E42/3DF42/3D67/24 NFFFFF85/24 N67/24 N67/48 N67/36 N67/30 N67/30 N67/30 N67/24 N67/30 N67/24 N67/30 N67/30 N67/24 N67/24 N67/24 NFFSTLSSSSSTTLSFFTSLSS S SSTTFFFFSSSLSSLSSSSFFFFLLLTSSTS S ST S S FF L TCRCRCRCR= CARD READER12111310149158167164176311541917230832122232531724262728b28a381032937319303134321223336351051061131141211231241081111161191251041071121151201361263181386162581021091101171186012959id_305320137134137A1351271281333163C.013S.02213153S.013S.033V.023V.03id_3021433C.02142139132130146140203141521443V.01id_301145147141321131148307id_304149322151183133123103098687888916830690171170167150323166153169165300301303302304178181182179180175174157176177158163159162160161154155173156305CROpen Area340COMMUNICATIONSLEVEL 3 DEMOFLOOR PLANTC-103DSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.DRAWING NOTES:1.DEMO EXISTING POWER, DATA AND BACKINGFOR DISPLAYS IN ROOMS 122, 305, 320, 321 & 322.2.NEW POWER, DATA AND BACKING SHALL BEBUILT OUT PER AV-4XX DRAWINGS.1Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 DNUPLARGE CONF.320MEDIUM CONF.122SMALL CONF.321SMALL CONF.322STORAGE323FOCUS324MEDIUM CONF.305BREAK ROOM302ARR102R101AAAAAAAOSAPAPAPAPAP03-AP:0503-AP:0403-AP:0303-AP:0203-AP:01Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.COMMUNICATIONSLEVEL 3 REFLECTEDCEILING PLANTC-2031Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 APAPAPAPAPAPAPAP= WIRELESS ACCESS POINT85/12 N 67/36 E 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 85/24 N 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T FF FF FF FF 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/42 E 67/48 E S F 24x60 BBF BBF FF FF FF FF 24x60 L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/30 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/48 E67/42 ES F30x60BBFBBF67/48 ES F30x60BBF67/42 E67/48 ES F30x60BBF67/42 E67/48 ES F30x6067/42 E67/24 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 NS FL TS FL TS FL TS FL T24x60BBFFFFFFFFF24x60BBF67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N42/3D42/3DS FL TS FL TS FL TS F36/2DFFFFFF42/3D42/3D42/3DCONF85/12 NS FL TS F30x60FFBBFS F30x60BBFBBF80/48S F30x60S F30x60BBF67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/42 E67/48 NS FL T30x60FFBBF30x60BBFBBF30x6030x60BBF67/48 NS F30x60FFBBF67/42 E67/42 E67/48 NS F30x60BBFBBF67/48 NS F30x6067/42 E67/42 E67/48 NS F30x60BBF42/3DFF67/42 ES FL TS FS FS FS F67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 EBBF30x6030x60BBFBBF30x6067/42 E67/48 NS FL T67/48 NS F67/42 E67/42 E67/48 NS F67/48 NS F67/42 E67/24 N42/3D42/3D42/3D36/3D36/3DSTAIRSRESTROOMRESTROOMELEVELEVSTAIRSELEVOFFICEOFFICECONFOFFICEOFFICEPLOTTEROFFICEOFFICECONFCONFCONF85/48 N85/42 N85/42 N85/48 N39/24 E39/24 N39/24 E36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2DS FBBFL T24x6636/2D36/2D36/2D42/3D42/3D39/48 E39/42 E39/48 E39/48 E39/42 E39/42 E39/42 E39/42 E39/48 E39/48 E39/42 E39/42 E39/48 EFFFF39/42 E39/48 EFFFF67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/24 N67/30 N67/30 N67/30 N36/3D67/24 N67/24 NF36/3DS FTTFL TS FTLFL TFFFFFFFFFFFFFF67/42 EBBF30x6067/48 N67/42 N67/36 E67/48 N67/42 N67/48 NS36/2D36/2D36/3D36/3D36/2D36/2D36/3D36/2D36/2D67/48 E67/42 E36/3D36/3D36/2DFF36/2D36/2DF85/42 E 85/48 N F30x 60 L TF67/42 EFBBF67/48 NBBF 30x60S F S L TF67/42 ES F67/48 N67/42 EF30x60BBF 30x60L TBBF S67/48 N67/42 EF67/42 E F67/42 ES67/48 N67/48 N F30x60 30x60BBFF 67/36 NBBFF67/48 N67/48 N SFL T67/42 EBBFBBFF30x60F67/42 EF67/42 E30x60SFL TBBFF BBF30x60F30x60BBF67/48 N67/48 N67/42 E67/48 NFFFFTFFL T30x 60 BBFF30x60S67/48 NS67/42 E 67/42 E67/24 N 67/24 N67/30 N LS30x6067/42 E S67/48 N67/36 E67/24 N 67/42 E67/48 N67/48 NS67/42 E 36/2D30x6036/2D67/48 E 67/30 N67/30 N 67/30 N67/24 N BBF 67/30 NBBF24x 60 24x60BBF24x60FF67/42 EBBFF 67/48 NBBF SSL T67/42 EBBFF30x60 BBF24x60BBFBBF24x 60 BBFFBBFF30x60 24x6024x60FFFF F30x60SS67/42 E67/48 NSL TS L TS FL T67/48 NBBF24x60 BBF 24x 60 5S67/42 EF67/48 NSBBF 30x6024x6024x6024x60BBFBBF BBF 24x 60 BBF BBF BBF24x6024x6067/30 N67/30 N67/24 N 67/24 N67/30 N67/24 N67/48 N67/42 N67/42 N67/48 N67/48 N67/42 N36/2D 36/2D 36/2D 24x6 0 24x6 0 24x 60 BBF24x60BBF BBF24x60BBFBBF67/42 E67/48 EFL T67/42 E 67/48 EFL T67/42 E67/48 EFS F36/2DFF36/2DBBFFFBBFFLFBBF24x6030x6036/2D 67/24 N 36/2D36/2D 67/30 NBBF BBF 24x60BBF24x6024x6067/24 N 67/30 N67/24 N67/30 N67/42 E 36/2D 67/42 E67/48 E67/48 ES36/3D36/3D FFFFFT67/42 ES F L T67/48 E 36/2D36/2D 36/2D 36/2D36/2D F36/2D30x60BBF 36/2D36/2D 36/2DFF67/42 E67/42 EBBFBBF30x6067/48 N67/48 NF30x60F67/42 E67/42 E67/42 E67/48 N67/48 N67/48 N67/24 N30x6030x6030x6067/48 NS67/48 NBBFSFBBF67/42 E67/42 E67/42 EBBFBBFFS67/48 N67/48 N30x6030x60F67/48 N67/42 E67/48 N67/48 NF67/42 EF67/48 NBBFS F30x60BBF36/3D36/3D30x6036/3D67/42 E36/2DBBFBBF30x6036/3D67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/30 N67/24 N67/30 NFF67/24 N67/48 E67/48 E67/30 N67/48 E67/42 E67/42 ESL TSSLS FL T67/42 E67/48 EFL67/42 ESLFFFF67/42 E67/42 E67/48 E67/48 E42/3DF42/3D67/24 NFFFFF85/24 N67/24 N67/48 N67/36 N67/30 N67/30 N67/30 N67/24 N67/30 N67/24 N67/30 N67/30 N67/24 N67/24 N67/24 NFFS TLSSSSSTTLSFFTSLS S S SSTTFFFFSSSLSSLSSSSFFFFLLLTSSTS S ST S S FF L T 12111310149158167164176311541917230832122232531724262728b28a381032937319303134321223336351051061131141211231241081111161191251041071121151201361263181386162581021091101171186012959id_305320137134137A1351271281333163C.013S.02213153S.013S.033V.023V.03id_3021433C.02142139132130146140203141521443V.01id_301145147141321131148307id_304149322151183133123103098687888916830690171170167150323166153169165300301303302304178181182179180175174157176177158163159162160161154155173156305APAPAPAPAPAPAPAPAPAPAPAPCOMMUNICATIONSLEVEL 3 REFLECTEDCEILING DEMO PLANTC-203DSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.DRAWING NOTES:1.DEMO ALL EXISTING AP DEVICES AND ASSOCIATED BACKING ANDCABLING IN AREAS NOT SHADED.2.EXISTING AP DEVICES IN RETAINED SPACE (SHADED AREA)SHALL NOT BE REMOVED UNTIL NEW AP DEVICES ARE INSTALLEDAND OPERATIONAL. CLIENT WILL NOTIFY CONTRACTOR WHENEXISTING AP DEVICES CAN BE REMOVED.1Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 403938371615141335113410330936122021222324444546474817411842194308320731063005290428032702262501ORGANIZERPATCH CORDSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.COMMUNICATIONSINSTALLATION DETAILSTC-3011Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 Scale: 3/4" = 1'-0"LEVEL 3 - IDF ROOM FLOOR PART PLAN1Scale: 3/4" = 1'-0"LEVEL 3 - IDF ROOM PATHWAY RCP PART PLAN2Scale: 1 1/2" = 1'-0"EQUIPMENT RACK ELEVATIONAACOMMUNICATIONSLEVEL 3 - IDF ROOMPART PLANS ANDELEVATIONSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.TC-4011Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 CAMCRELDCIssued for Bid04/07/2023ESMIssued for Permit and Construction04/21/2023Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.SECURITYNOTES, SYMBOLS ANDDRAWING LISTSC-0011Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 DNUPP47/24 E47/36 EP47/24 E47/36 EP47/24 E47/36 EPPPPI47/24 E47/36 E47/24 E47/36 E47/24 E47/36 EPI47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47 / 2 4 N 47/24 E24x6024x6024x6024x6024x6024x60PPPPPP47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N4 7 / 2 4 E 24x6024x6024x6024x6024x6024x6047/24 N24x60 24x6024x6024x6047/24 N47/24 NPPPP47/36 E47/24 E47/36 E47/24 E24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 NPIPPP47/36 E47/24 EP47/36 E47/24 EP47/36 E47/24 EP24x6024x6024x6024x6024x6024x6047/24 E47/24 N47/24 N47/24 N47/24 N47/24 N47/24 N47/24 NPIPPP47/36 E47/24 EP47/36 E47/24 EP47/36 E47/24 EP20202525252525252520252020202020202020252020252525252525202525202567/48 N67/24 N67/ 3 0 N 42/3D4 2 / 3 D 4 2 / 3 D42/3D42/3D42/3D3 6 / 3 D 36/3DPP67/42 E FSFFLT FS36/2DBBF30x6067/48 E67/42 E67/48 N67/36 N67/48 N67/42 E FSF F L T FS 36/2DBBF30x6067/48 N67/ 3 6 N 67/30 E67/42 E FSLT FS36/2D30x6067/48 E67/42 E67/48 N3 6 / 3 D67/30 N67/36 N67/42 ETL FS67/36 E67/36 E FS LT67/24 N24x6667/24 N 67/24 N39/24 N39/24 E39/24 EPP67/48 E36/2D67/36 E 42/3D42/3D36/3D36/3D36/3D36/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D42/3D36/3D36/3D36/3D3 6 / 3 D 36/3D36/3D36/3D36/3D85/12 N 85/24 N80/4885/24 N 85/12 N FS67/48 E67/30 NPI39/42 EPIPI67/24 N 67/30 N 67/30 N67/48 N67/48 E67/42 E FSFFLT FS36/2DBBF30x6067/42 E67/24 N67/30 N 67/30 N67/48 N67/48 E67/42 E FSFFLT FS36/2DBBF30x6067/42 EPI 67/30 N 67/30 N67/48 N67/48 E67/42 E FSFFLT FS36/2DBBF30x6067/42 EPIPIPI FSFFLT FS36/2DBBF30x6067/24 N67/30 N FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/30 N67/42 E67/48 N67/42 E67/48 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N 67/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/48 E67/42 E 67/48 N67/30 N85/42 N85/42 N85/48 N85/48 N85/48 N85/42 E FSFFLT FS36/2DBBF30x6067/24 N67/30 N FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/30 N67/42 E67/48 N67/42 E67/48 NLT FS36/2DBBF67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/48 N67/30 N 67/42 E FSFF L T FS 36/2DBBF30x6067/24 N67/48 E67/42 E 67/48 N67/30 N39/ 4 2 E39/48 E FS FSLT67/36 N67/48 NF F 36/2DBBF30x6039/42 E39/48 E 39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E39/42 E39/48 E FS FS FS FS FS FS FS FSF F LT36/2DBBF30x6067/24 N67/30 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E67/48 N67/42 E FSF F LT36/2DBBF30x6067/24 N67/48 N67/42 E FSF F LT36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT36/2DBBF67/24 N67/48 N67/30 N67/42 E FSFF LT36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N FSF F L T FS36/2DBBF30x6067/24 N67/30 N FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/30 N67/42 E67/48 N67/42 E FSFFL T FS 36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/ 3 0 N 67/42 E FSF F 36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSF F L T FS 36/2DBBF30x6067/24 N67/48 N67/42 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/42 N67/48 E67/42 E67/48 N67/30 NPP67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/48 E67/42 E67/42 E FSFFLT FS3 6 / 2 D BBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/ 4 2 N 67/48 N67/30 N67/42 E FSFF36/2DBBF30 x 6 0 67/24 N67/ 4 8 N67/48 E67/42 E67/48 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 E67/42 E67/48 N67/30 N67/42 E FSFFLT FS36/2DBBF30x6067/24 N67/48 N67/ 4 2 N 67/48 N67/30 N67/42 E FSLT FSBBF30x6067/48 E67/42 E67/48 N67/30 N36/2D36/2DCRDRRRRRRRRRRPT(F)CPT(F)CWBBWBBWBBWBBWBBWBBWBBWBBWBBWBBLARGE CONF.320MEDIUM CONF.122BREAK ROOM302MEDIUM CONF.305FOCUS324STORAGE323SMALL CONF.322SMALL CONF.321OPEN OFFICEOPEN OFFICEOPEN OFFICEIDF304WELLNESS306102103104105106107108109110111112113114115116117118119120121122123124125126127128134133132131130129138139137136135150140141142143144145146147148149151152153154155156157162163168167166165164161158159160172173174171170169178177176175CRDCESMCRCRDCESMCRCRSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.SECURITYLEVEL 3 FLOOR PLANSC-1031Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 85/12 N 67/36 E 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 85/24 N 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T FF FF FF FF 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/42 E 67/48 E S F 24x60 BBF BBF FF FF FF FF 24x60 L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/30 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/48 E67/42 ES F30x60BBFBBF67/48 ES F30x60BBF67/42 E67/48 ES F30x60BBF67/42 E67/48 ES F30x6067/42 E67/24 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 NS FL TS FL TS FL TS FL T24x60BBFFFFFFFFF24x60BBF67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N42/3D42/3DS FL TS FL TS FL TS F36/2DFFFFFF42/3D42/3D42/3DCONF85/12 NS FL TS F30x60FFBBFS F30x60BBFBBF80/48S F30x60S F30x60BBF67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/42 E67/48 NS FL T30x60FFBBF30x60BBFBBF30x6030x60BBF67/48 NS F30x60FFBBF67/42 E67/42 E67/48 NS F30x60BBFBBF67/48 NS F30x6067/42 E67/42 E67/48 NS F30x60BBF42/3DFF67/42 ES FL TS FS FS FS F67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 EBBF30x6030x60BBFBBF30x6067/42 E67/48 NS FL T67/48 NS F67/42 E67/42 E67/48 NS F67/48 NS F67/42 E67/24 N42/3D42/3D42/3D36/3D36/3DSTAIRSRESTROOMRESTROOMELEVELEVSTAIRSELEVOFFICEOFFICECONFOFFICEOFFICEPLOTTEROFFICEOFFICECONFCONFCONF85/48 N85/42 N85/42 N85/48 N39/24 E39/24 N39/24 E36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2DS FBBFL T24x6636/2D36/2D36/2D42/3D42/3D39/48 E39/42 E39/48 E39/48 E39/42 E39/42 E39/42 E39/42 E39/48 E39/48 E39/42 E39/42 E39/48 EFFFF39/42 E39/48 EFFFF67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/24 N67/30 N67/30 N67/30 N36/3D67/24 N67/24 NF36/3DS FTTFL TS FTLFL TFFFFFFFFFFFFFF67/42 EBBF30x6067/48 N67/42 N67/36 E67/48 N67/42 N67/48 NS36/2D36/2D36/3D36/3D36/2D36/2D36/3D36/2D36/2D67/48 E67/42 E36/3D36/3D36/2DFF36/2D36/2DF85/42 E85/48 N F30x60L TF67/42 EFBBF67/48 NBBF30x60S FSL TF67/42 ES F67/48 N67/42 EF30x60BBF30x60L TBBF S67/48 N 67/42 EF67/42 EF67/42 ES67/48 N 67/48 NF30x6030x60BBFF67/36 NBBFF67/48 N67/48 N SFL T67/42 EBBFBBFF30x60F67/42 EF67/42 E30x60SFL TBBFF BBF30x60F30x60BBF 67/48 N67/48 N67/42 E67/48 NFFFF TFFL T30x60BBFF30x60S67/48 NS67/42 E 67/42 E67/24 N 67/24 N67/30 NLS 30x6067/42 E S 67/48 N67/36 E67/24 N 67/42 E67/48 N67/48 NS67/42 E 36/2D30x6036/2D 67/48 E67/30 N 67/30 N67/30 N67/24 N BBF 67/30 N BBF24x6024x60BBF24x60FF67/42 EBBFF 67/48 NBBF SSL T67/42 EBBFF30x60 BBF 24x60BBFBBF24x60 BBFFBBF F30x60 24x6024x60FFFFF 30x60SS67/42 E67/48 NSL TSL TS FL T67/48 N BBF24x 60 BBF 24x6 0 5S67/42 EF67/48 NSBBF30x60 24x6024x6024x6 0 BBFBBFBBF 24x6 0 BBF BBFBBF24x6024x6067/30 N67/30 N67/24 N67/24 N67/30 N 67/24 N 67/48 N67/42 N67/42 N 67/48 N67/48 N 67/42 N36/2D 36/2D36/2D 24x6024x6 0 24x6 0 BBF 24x60BBFBBF 24x60BBFBBF67/42 E67/48 EF L T67/42 E 67/48 EFL T67/42 E67/48 EFS F36/2DFF36/2DBBFFFBBFFLF BBF24x6030x6036/2D 67/24 N 36/2D36/2D 67/30 N BBF BBF 24x60BBF24x6024x6067/24 N67/30 N67/24 N 67/30 N 67/42 E36/2D 67/42 E 67/48 E67/48 ES 36/3D 36/3D FFFFFT67/42 ES F L T67/48 E36/2D36/2D 36/2D36/2D36/2DF36/2D30x60BBF 36/2D 36/2D36/2DF F67/42 E67/42 EBBFBBF30x6067/48 N67/48 NF30x60F67/42 E67/42 E67/42 E67/48 N67/48 N67/48 N67/24 N30x6030x6030x6067/48 NS67/48 NBBFSFBBF67/42 E67/42 E67/42 EBBFBBFFS67/48 N67/48 N30x6030x60F67/48 N67/42 E67/48 N67/48 NF67/42 EF67/48 NBBFS F30x60BBF36/3D36/3D30x6036/3D67/42 E36/2DBBFBBF30x6036/3D67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/30 N67/24 N67/30 NFF67/24 N67/48 E67/48 E67/30 N67/48 E67/42 E67/42 ESL TSSLS FL T67/42 E67/48 EFL67/42 ESLFFFF67/42 E67/42 E67/48 E67/48 E42/3DF42/3D67/24 NFFFFF85/24 N67/24 N67/48 N67/36 N67/30 N67/30 N67/30 N67/24 N67/30 N67/24 N67/30 N67/30 N67/24 N67/24 N67/24 NFFSTLSSSSSTTLSFFTSLSS S SSTTFFFFSSSLSSLSSSSFFFFLLLTSSTS S ST S S FF L TCRCRCR= CARD READER12111310149158167164176311541917230832122232531724262728b28a381032937319303134321223336351051061131141211231241081111161191251041071121151201361263181386162581021091101171186012959id_305320137134137A1351271281333163C.013S.02213153S.013S.033V.023V.03id_3021433C.02142139132130146140203141521443V.01id_301145147141321131148307id_304149322151183133123103098687888916830690171170167150323166153169165300301303302304178181182179180175174157176177158163159162160161154155173156305Open Area340SECURITYLEVEL 3 DEMOFLOOR PLANSC-103DSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.DRAWING NOTES:1.DEMO EXISTING CARD READERS AND ITSASSOCIATED BACKING AND CABLING INDICATEDON DRAWING.1Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 DNUPLARGE CONF.320MEDIUM CONF.122SMALL CONF.321SMALL CONF.322STORAGE323FOCUS324MEDIUM CONF.305BREAK ROOM302ARR102R101AAAAAAASheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.SECURITYLEVEL 3 REFLECTEDCEILING PLANSC-2031Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 C= SECURITY CAMERA85/12 N 67/36 E 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 85/24 N 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T FF FF FF FF 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/24 N 67/42 E 67/48 E S F 24x60 BBF BBF FF FF FF FF 24x60 L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/42 E 67/48 E S F L T 67/30 N 67/30 N 67/24 N 67/30 N 67/24 N 67/30 N 67/48 E67/42 ES F30x60BBFBBF67/48 ES F30x60BBF67/42 E67/48 ES F30x60BBF67/42 E67/48 ES F30x6067/42 E67/24 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 NS FL TS FL TS FL TS FL T24x60BBFFFFFFFFF24x60BBF67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N67/24 N67/30 N42/3D42/3DS FL TS FL TS FL TS F36/2DFFFFFF42/3D42/3D42/3DCONF85/12 NS FL TS F30x60FFBBFS F30x60BBFBBF80/48S F30x60S F30x60BBF67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 N67/42 E67/48 NS FL T30x60FFBBF30x60BBFBBF30x6030x60BBF67/48 NS F30x60FFBBF67/42 E67/42 E67/48 NS F30x60BBFBBF67/48 NS F30x6067/42 E67/42 E67/48 NS F30x60BBF42/3DFF67/42 ES FL TS FS FS FS F67/48 N67/48 N67/42 E67/42 E67/48 N67/48 N67/42 E67/42 E67/48 EBBF30x6030x60BBFBBF30x6067/42 E67/48 NS FL T67/48 NS F67/42 E67/42 E67/48 NS F67/48 NS F67/42 E67/24 N42/3D42/3D42/3D36/3D36/3DSTAIRSRESTROOMRESTROOMELEVELEVSTAIRSELEVOFFICEOFFICECONFOFFICEOFFICEPLOTTEROFFICEOFFICECONFCONFCONF85/48 N85/42 N85/42 N85/48 N39/24 E39/24 N39/24 E36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2D36/2DS FBBFL T24x6636/2D36/2D36/2D42/3D42/3D39/48 E39/42 E39/48 E39/48 E39/42 E39/42 E39/42 E39/42 E39/48 E39/48 E39/42 E39/42 E39/48 EFFFF39/42 E39/48 EFFFF67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/24 N67/30 N67/30 N67/30 N36/3D67/24 N67/24 NF36/3DS FTTFL TS FTLFL TFFFFFFFFFFFFFF67/42 EBBF30x6067/48 N67/42 N67/36 E67/48 N67/42 N67/48 NS36/2D36/2D36/3D36/3D36/2D36/2D36/3D36/2D36/2D67/48 E67/42 E36/3D36/3D36/2DFF36/2D36/2DF85/42 E85/48 NF 30x60L TF67/42 EFBBF67/48 NBBF30x60S FSL TF67/42 ES F67/48 N67/42 EF30x60BBF 30x60L TBBFS67/48 N 67/42 EF67/42 EF67/42 ES67/48 N67/48 N F30x6030x60 BBFF67/36 NBBFF67/48 N67/48 N SFL T67/42 EBBFBBFF30x60F67/42 EF67/42 E30x60SFL TBBFFBBF30x60F30x60BBF 67/48 N67/48 N67/42 E67/48 NFFFFTFF L T30x6 0 BBFF 30x60S67/48 NS 67/42 E 67/42 E67/24 N 67/24 N67/30 NLS30x6067/42 E S67/48 N67/36 E67/24 N 67/42 E67/48 N67/48 NS67/42 E36/2D30x6036/2D67/48 E67/30 N 67/30 N67/30 N 67/24 N BBF 67/30 NBBF24x6 0 24x60BBF24x6 0 FF67/42 EBBFF 67/48 NBBF SSL T67/42 EBBFF30x60 BBF 24x60BBFBBF 24x6 0 BBFFBBF F30x60 24x6024x60FFFFF30x60SS 67/42 E67/48 NSL TSL TS FL T67/48 NBBF24x60BBF24x60 5S67/42 EF67/48 NSBBF30x6024x60 24x6024x6 0 BBFBBF BBF 24x 60 BBFBBFBBF24x6024x6067/30 N67/30 N67/24 N 67/24 N67/30 N67/24 N 67/48 N67/42 N67/42 N67/48 N67/48 N67/42 N36/2D 36/2D 36/2D 24x 60 24x60 24x60BBF24x60BBF BBF 24x60BBFBBF67/42 E67/48 EFL T67/42 E67/48 EFL T67/42 E67/48 EFS F36/2DFF36/2DBBF FFBBFFLF BBF24x6030x6036/2D67/24 N 36/2D36/2D 67/30 NBBF BBF 24x60BBF 24x6024x6067/24 N67/30 N67/24 N67/30 N67/42 E36/2D67/42 E67/48 E67/48 ES36/3D36/3DFFFFFT67/42 ES F L T67/48 E36/2D36/2D36/2D36/2D36/2D F36/2D 30x60BBF36/2D 36/2D36/2DF F67/42 E67/42 EBBFBBF30x6067/48 N67/48 NF30x60F67/42 E67/42 E67/42 E67/48 N67/48 N67/48 N67/24 N30x6030x6030x6067/48 NS67/48 NBBFSFBBF67/42 E67/42 E67/42 EBBFBBFFS67/48 N67/48 N30x6030x60F67/48 N67/42 E67/48 N67/48 NF67/42 EF67/48 NBBFS F30x60BBF36/3D36/3D30x6036/3D67/42 E36/2DBBFBBF30x6036/3D67/24 N67/24 N67/24 N67/30 N67/30 N67/30 N67/30 N67/24 N67/30 NFF67/24 N67/48 E67/48 E67/30 N67/48 E67/42 E67/42 ESL TSSLS FL T67/42 E67/48 EFL67/42 ESLFFFF67/42 E67/42 E67/48 E67/48 E42/3DF42/3D67/24 NFFFFF85/24 N67/24 N67/48 N67/36 N67/30 N67/30 N67/30 N67/24 N67/30 N67/24 N67/30 N67/30 N67/24 N67/24 N67/24 NFFSTLSSSSSTTLSFFTSLSS S SSTTFFFFSSSLSSLSSSSFFFFLLLTSSTS S ST S S FF L T12111310149158167164176311541917230832122232531724262728b28a381032937319303134321223336351051061131141211231241081111161191251041071121151201361263181386162581021091101171186012959id_305320137134137A1351271281333163C.013S.02213153S.013S.033V.023V.03id_3021433C.02142139132130146140203141521443V.01id_301145147141321131148307id_304149322151183133123103098687888916830690171170167150323166153169165300301303302304178181182179180175174157176177158163159162160161154155173156305CCSECURITYLEVEL 3 REFLECTEDCEILING DEMO PLANSC-203DSheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.1Issued for Bid04/07/2023DRAWING NOTES:1.DEMO EXISTING SECURITY CAMERAS AND ITSASSOCIATED BACKING AND CABLING INDICATEDON DRAWING.2Issued for Permit and Construction04/21/2023 UNSECURE SIDESPECIFICATION - GENERALSPECIFICATION - PRODUCTS21345678910APPLICABLE STANDARDSSPECIFICATION - EXECUTIONELECTRICAL REQUIREMENTSFUNCTIONAL NARRATIVESheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.SECURITYTYPICAL DOORELEVATIONSSC-3011Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023 NOTE: JUNCTION BOX SHALLBE PROVIDED BY ELECTRICALCONTRACTOR.4"6"6"6"x6"x4" NEMA 1 JUNCTION BOX USEDTO ROUTE CABLING FROM EACHDEVICE LOCATION TO NEARESTACCESSIBLE CABLE TRAY.3.31"4.37"1.10"FURNISH AND INSTALL CARDREADER, SURFACE MOUNTED@ 42" A.F.F. (TYP.)2C/22AWGREDEOL ResistorWHTREDBLKWHTBLKREDBLKNOTES:1.SECURITY INTEGRATOR IS TOFURNISH AND INSTALL END OFLINE RESISTORS (EOLR) NEARDEVICE LOCATION.2.EOLR LOCATED WITHIN ACCESSCONTROL PANEL WILL NOT BEEXCEPTED.FINISHED FLOORNOTE: ALL ARCHITECTURALGRAPHIC REPRESENTATIONSARE FOR REFERENCE ONLY.SWITCH UNITMAGNETIC UNIT3/4" CONDUIT TO OVERHEADJUNCTION BOX (BY EC)2C/22AWG UNSHIELDED3/4" RECESSED MAGNETICDOOR CONTACT DRILLEDTHRU FRAMEDOOR; PER ARCH'L516" (MAX)SECUREDSIDEUNSECUREDSIDEWALL; PER ARCH'LFRAME; PER ARCH'LFRONTNOTE: ALL ARCHITECTURALGRAPHIC REPRESENTATIONSARE FOR REFERENCE ONLY.TO JUNCTION BOX4C/18AWG UNSHIELDED CABLEFRAME; PER ARCH'LSCHEDULED DOOR(BY DIVISION 8)POWER TRANSFERHINDGE (BY DIVISION 8)DOOR CABLE HARNESS(BY DIVISION 8)SIDEFINISHED FLOORFRONTNOTE: ALL ARCHITECTURALGRAPHIC REPRESENTATIONSARE FOR REFERENCE ONLY.4C/18AWGUNSHIELDEDCABLEFRAME; PER ARCH'LSCHEDULED DOOR(BY DIVISION 8)DOOR CABLE HARNESS(BY DIVISION 8)SIDEFINISHED FLOORELECTRIC MORTISELOCK (BY DIVISION 8)42"A.F.F.NOTE: ALL ARCHITECTURALGRAPHIC REPRESENTATIONSARE FOR REFERENCE ONLY.FRONT6C/22AWG O.A. SHIELDED4"x2 1/8" METALIC SINGLEGANG BACK BOX (BY EC)WALL; PER ARCH'LCARD READERUNSECUREDSIDE3/4" CONDUIT TO OVERHEADJUNCTION BOX (BY EC)FINISHED FLOORSOFTWARE HOUSENOTE: ALL ARCHITECTURALGRAPHIC REPRESENTATIONARE FOR REFERENCES ONLYACCESSIBLE CEILING,PER ARCH'LFURNISH AND INSTALLCATEGORY 6 UTP CABLEJ-HOOK (TYPICAL)CEILING SLABFURNISH AND INSTALLIP CAMERASECURITYTYPICAL INSTALLATIONDETAILSSC302Sheet NumberOriginal is 42 x 30. Do not scale contents of this drawing.Sheet TitleProfessional SealsKey PlanIn Association withProjectAll reproduction & intellectual property rights reserved ©No.DescriptionDatePrepared ForProject No:Verizon Indianapolis250 E. 96th Street, 3rd FloorIndianapolis, IndianaVERIZON23.09600.00Client Location2023717 North Harwood StreetSuite 2850, LB 8Dallas, TX 75201 USAt +1 214 720 6000 www.hok.comHellmuth, Obata & Kassabaum, Inc.1Issued for Bid04/07/20232Issued for Permit and Construction04/21/2023