Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Packet for COM 08-01-23
CARMEL PLAN COMMISSION INFORMATION PACKET ADLS AMENDMENT CASE NO. PZ-2023-00141 APPLICANT: TM CROWLEY & ASSOCIATES, LLC PROJECT NAME: LAKE CITY BANK REMODEL PROJECT ADDRESS: 1361 SOUTH RANGELINE ROAD Attorney for Petitioner Joseph D. Calderon Barnes &Thornburg LLP 11 South Meridian Street Indianapolis, Indiana 46204 (317) 231-7787 jcalderon@btlaw.com INDEX TO PACKET EXHIBITS Exhibit No. Description 1. Description of Project 2. Location Map 3. Existing Conditions 4. Proposed Site Plan 5. Proposed Landscaping Plan 6. Proposed Floor Plan 7. Proposed Exterior Elevations 8. Proposed Light Fixtures 9. Photometric Plan 10. Proposed Building Signage 11. Proposed Monument Sign 26948342.1 Project Description Lake City Bank Remodel 1361 S. Rangeline Road The project consists of the adaptive re-use of the former Day Furs retail store into a new location for Lake City Bank. The interior of the building will be completely renovated for the new use. The exterior of the building will be modified to be more consistent with other Lake City Bank locations and to provide for ATM and drive-thru functions. The site will be modified to provide vehicular access to the ATM/drive-through, reconfigured parking, improved pedestrian access, bike racks, and additional landscaping. The exterior of the building will have new brick in place of much of the existing siding. Other existing siding areas will be replaced with EIFS (Exterior Insulation Finish System/synthetic stucco). Existing windows will be modified, and more windows will be added. New exterior building mounted lighting will be provided. New signage for Lake City Bank will be provided on the building and on a proposed monument sign. 26957514.1 PAGE 7 EXISTING EXTERIOR CONDITIONS - 06/14/2023 TM CROWLEY LAKE CITY BANK 07/21/2023 LEVEL 1 0" T/O STEEL 9' -8 1/2" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0"LEVEL 2 11' -6 1/2" T/O ROOF 36' -6" LEVEL 1 0" T/O STEEL 9' -8 1/2" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0"LEVEL 2 11' -6 1/2" EXISTING WINDOWS TO BE REPLACED EXISTING GAS METER T/O ROOF 36' -6" LEVEL 1 0" T/O STEEL 9' -8 1/2" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0"LEVEL 2 11' -6 1/2" PORTION OF ROOF CANOPY AND COLUMN/ STONE BASE TO BE REMOVED AND INFILLED T/O ROOF 36' -6" LEVEL 1 0" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0"LEVEL 2 11' -6 1/2" T/O ROOF 36' -6" EXISTING EXTERIOR ELEVATIONS - 06/14/2023 TM CROWLEY LAKE CITY BANK 1/16" = 1'-0"1 EXISTING NORTH ELEVATION 1/16" = 1'-0"2 EXISTING SOUTH ELEVATION 1/16" = 1'-0"3 EXISTING EAST ELEVATION 1/16" = 1'-0"4 EXISTING WEST ELEVATION EXISTING HALF ROUND WINDOW TO BE REMOVED AND INFILLED EXISTING CONDENSERS TO BE RELOCATED EXISTING WINDOWS TO BE REPLACED EXISTING STOREFRONT TO BE REMOVED AND INFILLED PORTION OF ROOF CANOPY AND COLUMN/ STONE BASE SUPPORTS TO BE REMOVED PORTION OF ROOF CANOPY AND COLUMN/ BASE TO BE REMOVED PAGE 8 07/21/2023 PAGE 4 PLOT DATE (36"x24"): 7/20/2023 11:13 AM DRAWING FILE: P:\2023\00846\D. Drawings\Civil\Exhibits\2023-07-18- Colored Site Exhibit\Colored Site Plan Exhibit - Aerial.dwg 0'20' tm crowley lAkE city bAnk 07/21/2023 oVerAll SIte eXHIBIt w/AerIAl PAGE 5 PLOT DATE (36"x24"): 7/20/2023 11:11 AM DRAWING FILE: P:\2023\00846\D. Drawings\Civil\Exhibits\2023-07-18- Colored Site Exhibit\Colored Site Plan Exhibit.dwg 0'10' oVerAll SIte eXHIBIt tm crowley lAkE city bAnk 07/21/2023 PAGE 6 PLOT DATE (36"x24"): 7/20/2023 11:07 AM DRAWING FILE: P:\2023\00846\D. Drawings\Civil\Exhibits\2023-06-01 - Site-Landscape Exhibits\Conceptual Landscape Exhibit.dwg 0'10' TREES CODE QTY BOTANICAL NAME COMMON NAME COND.SIZE SPACING CK 6 Cladrastis kentukea American Yellowwood B & B 2.5" Cal.As shown SHRUBS CODE QTY BOTANICAL NAME COMMON NAME COND.SIZE SPACING HJ 5 Hydrangea paniculata 'Jane'Little Lime® Panicle Hydrangea CONT.3 GAL.4` O.C. IS 28 Itea virginica `Sprich`Little Henry® Sweetspire CONT.3 GAL.3` O.C. TD 5 Taxus x media `Densiformis`Dense Yew CONT.3 GAL.4` O.C. VS 12 Viburnum dentatum `Synnestvedt`Chicago Lustre® Arrowwood Viburnum CONT.3 GAL.8` O.C. WS 5 Weigela florida `Bokraspiwi`Spilled Wine® Weigela CONT.3 GAL.4` O.C. GRASSES CODE QTY BOTANICAL NAME COMMON NAME COND.SIZE SPACING CA 15 Calamagrostis x acutiflora `Karl Foerster`Feather Reed Grass CONT.3 GAL.3` O.C. PLANT SCHEDULE coNcePtUAl lANDScAPe eXHIBIt tm crowley lAkE city bAnk 07/21/2023 PAGE 9 RF .NIGHT DEPOSIT DEAL DRAWER/ WINDOW276 SF CONFERENCE 629 SF LOBBY 308 SF CASH ROOM 181 SF MANAGER 150 SF OFFICE 150 SF OFFICE 150 SF OFFICE 150 SF OFFICE 521 SF TRAINING ROOM 58 SF WELLNESS 51 SF RR 74 SF TRASH 73 SF VESTIBULE (VAULTED CEILING) CASH RECYCLER ATM 92 SF COPY/PRINT 167 SF STORAGE/MECH. 56 SF IT 336 SF TELLER 353 SF RECEPTION 22' - 3 1/4" 12' - 6 3/4"10' - 5"10' - 5"10' - 5"10' - 5" 20' - 1 1/2"18' - 0 1/2"30' - 4 1/2"6' - 8"12' - 0 1/2"6' - 7 1/4"11' - 2 7/8"7' - 0 1/2"19' - 7" 14' - 0" OVERHEAD CANOPY 23' - 0 5/8"8' - 8" WINDOWS TBD FAUX WINDOWS 3' - 4" 5' - 9" 7' - 4"29' - 1 3/8"9' - 11 1/2"9' - 3 3/4"6' - 5" 5' - 9"12' - 5 1/4"SCHEMATIC DESIGN - 07/21/2023 TM CROWLEY LAKE CITY BANK 3/32" = 1'-0"1 CONCEPTUAL FLOOR PLAN - OPTION 3 ScHemAtIc Floor PlAN LEVEL 1 0" T/O STEEL 9' -8 1/2" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0" NEW EIFS (TYP.) NEW WINDOW TO REPLACE EXISTING NEW 3' X 5' FAUX WINDOWS NEW 3' X 5' FIXED WINDOWS TELLER WINDOW / DEAL DRAWERNIGHT DEPOSIT ATM DRIVE-THRU CANOPY PILASTERS (TYP.) EXIST. STONE SILL EXIST. SPLIT FACE CMU - PREP + PAINT T/O ROOF 36' -6" LEVEL 1 0" T/O STEEL 9' -8 1/2" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0" NEW WINDOW TO REPLACE EXISTING NEW BRICK TO REPLACE EXISITING SIDING (TYP.) NEW EIFS (TYP.) EXISTING GAS METER NEW 3' X 5' FIXED WINDOWS T/O ROOF 36' -6" LEVEL 1 0" T/O STEEL 9' -8 1/2" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0" NEW EIFS RELOCATED CONDENSERS T/O ROOF 36' -6" JOINTS OR REVEALS IN EIFS EIFS LEVEL 1 0" T/O STEEL 9' -8 1/2" TRUSS BEARING HEIGHT 21' -0 5/8" B/O DORMERS 14' -0" GLASS SUNSHADES W/ BRACKET SUPPORTS LAKE CITY BANK SIGNAGE NEW EIFS T/O ROOF 36' -6" JOINTS OR REVEALS IN EIFS EXTERIOR MATERIALS SW 9616 DUMPLING BELDEN CANYON FULL RANGE SMOOTH MODULAR SIZE P1 B1 PROPOSED EXTERIOR ELEVATIONS (COLOR) - 07/21/2023 TM CROWLEY LAKE CITY BANK 1/16" = 1'-0"1 NORTH ELEVATION COLOR 1/16" = 1'-0"2 SOUTH ELEVATION COLOR 1/16" = 1'-0"3 EAST ELEVATION COLOR 1/16" = 1'-0"4 WEST ELEVATION COLOR PAGE 10 PROPOSED EXTERIOR PERSPECTIVES - 07/21/2023 TM CROWLEY LAKE CITY BANK 1 NORTH WEST PERSPECTIVE2SOUTH WEST PERSPECTIVE 4 SOUTH EAST PERSPECTIVE 3 NORTH EAST PERSPECTIVE PAGE 11 PAGE 13 lIgHt FIXtUreS tm crowley lAkE city bAnk Description DOC120 LED for new construction. For remodel projects, see DOC120 LED [For Remodel] version. IP66, Class I. IK07. Marine-grade, die-cast aluminum alloy. 5CE superior corrosion protection including PCS hardware. Silicone CCG® Controlled Compression Gasket. Safety glass lens. Separate IP66 driver housing. CAD-optimized optics for superior illumination and glare control. OLC® One LED Concept. Factory installed LED circuit board. 0-10V Dimming comes standard with luminaire. Optional 2200 K version available, to be specified at time of ordering. Specify product with 7 Digit product code – Finish Color. Accessories, such as mounting, optical, and electrical, must be specified separately. Example: XXX-XXXX – 9004 (Black) + XXX-XXXX (Accessory 1) DOC120 LED [New Construction] Ceiling Luminaires 1/5 WE-EF LIGHTING USA LLC Spec Support Hotline: +1 412 783 0949 | 410-D Keystone Drive | Warrendale PA 15086 U.S.A. | Tel +1 724 742 0030 | info.usa@we-ef.com | www.we-ef.com | 27-03-2023 22:20 Technical modifications and errors excepted Description IP66. Class I. IK08. Marine-grade, die-cast aluminum alloy. 5CE superior corrosion protection including PCS hardware. Silicone CCG® Controlled Compression Gasket. CAD-optimized optics for superior illumination and glare control. Integral driver. Advanced thermal management protects LEDs while optimizing lumens output. 0-10V Dimming comes standard with luminaire. Luminaire is factory-sealed and does not need to be opened during installation. Luminaire can be mounted for up or down lighting. Specify product with 7 Digit product code – Finish Color. Accessories, such as mounting, optical, and electrical, must be specified separately. Example: XXX- XXXX-9004 (Black) + XXX-XXXX (Accessory 1) PLS430 LED Surface Mounted Wall Luminaires 1/6 WE-EF LIGHTING USA LLC Spec Support Hotline: +1 412 783 0949 | 410-D Keystone Drive | Warrendale PA 15086 U.S.A. | Tel +1 724 742 0030 | info.usa@we-ef.com | www.we-ef.com | 24-05-2023 10:14 Technical modifications and errors excepted 07/21/2023 PAGE 14 lIgHt FIXtUreS tm crowley lAkE city bAnk Description Surface-mounted wall luminaire. IP66. Class I. IK07. Marine-grade, die-cast aluminum alloy. 5CE superior corrosion protection including PCS hardware. Silicone CCG® Controlled Compression Gasket. Safety glass lens. Two cable entries. CAD-optimized optics for superior illumination and glare control. Integral driver. OLC® One LED Concept. Factory-installed LED circuit board. 0- 10V Dimming comes standard with luminaire. Suitable for Up, Down, or Up/Down light distribution. Supplied with wall plate to fit over 4” recessed junction box. Specify product with 7 Digit product code – Finish Color. Accessories, such as mounting, optical, and electrical, must be specified separately. Example: XXX-XXXX-9004 (Black) + XXX-XXXX (Accessory 1) SLS410 LED Surface Mounted Wall Luminaires 1/6 WE-EF LIGHTING USA LLC Spec Support Hotline: +1 412 783 0949 | 410-D Keystone Drive | Warrendale PA 15086 U.S.A. | Tel +1 724 742 0030 | info.usa@we-ef.com | www.we-ef.com | 20-03-2023 20:12 Technical modifications and errors excepted Description Available as an Impact-Rated Bollard (SC40, PU40), specify impact designation with your order, options below. IP66. Class I. IK10. Marine-grade, all aluminum construction. 5CE superior corrosion protection including PCS hardware. Silicone CCG® Controlled Compression Gasket. Polycarbonate main lens. CAD-optimized indirect optics for superior illumination and glare control. Integral driver in thermally separated compartment. Factory-installed LED circuit board. 0-10V Dimming comes standard with luminaire. Pre-wired post complete with cable connecting box and fuse for mains connection. Specify product with 7 Digit product code – Finish Color. Accessories, such as mounting, optical, and electrical, must be specified separately. Example: XXX- XXXX-9004 (Black) + XXX-XXXX (Accessory 1) ZFY230 LED-FT II Bollards and Pathway Luminaires 2/6 WE-EF LIGHTING USA LLC Spec Support Hotline: +1 412 783 0949 | 410-D Keystone Drive | Warrendale PA 15086 U.S.A. | Tel +1 724 742 0030 | info.usa@we-ef.com | www.we-ef.com | 06-04-2023 16:43 Technical modifications and errors excepted 07/21/2023 PAGE 15 lIgHt FIXtUreS tm crowley lAkE city bAnk DATE:LOCATION: TYPE:PROJECT: CATALOG #: A B C D E 8.7" 9.7" 3.9" 7.0" 5.0" 221mm 246mm 99mm 178mm 127mm F G H 10.4" 11.0" 5.9" 264mm 279mm 150mm Weight 6.5 lbs (2.95 kgs) 7 11 5 4 9.73 5.85 10.37 8.73 7 11 5 4 9.73 5.85 10.37 8.73 A F G H C B D E RWL1 RWL1 with Integral Back Box N O P 15.4" 16.0" 5.5" 391mm 406mm 140mm I J K L M 14.0" 15.0" 3.9" 12.0" 5.0" 356mm 381mm 99mm 305mm 127mm Weight 16.5 lbs (7.48 kgs) 15.37 16 5.54 15 3.88 12 5 15.37 16 5.54 15 3.88 12 5 N O I J K P L M RWL2 RWL2 with Integral Back Box Type 2 Mounting Height: 30ft Type 3 Type 4WType 4F currentlighting.com/beacon © 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. Page 5 of 7 Rev 01/19/23 Ratio_Wall_Spec_Sheet_R01 RATIO Wall RWL1/RWL2 LED WALLPACK DIMENSIONS PHOTOMETRY 07/21/2023 PAGE 12 PHotometrIc PlAN tm crowley lAkE city bAnk Scale: 1 inch= 10 Ft.SITE LIGHTING - PLAN VIEW LT3 LT3 LT4LT4LT4LT4LT4 LT2 LT2 OVERHEADCANOPY LT1 LT1 LT1 LT1 LT2 MH: 5.7 LT2 MH: 5.7 MH: 9 LT4 MH: 9 LT4 LT4 MH: 9 MH: 9 LT4 MH: 9 LT4 MH: 0 LT1 MH: 0LT1 MH: 0LT1 LT1 MH: 0 LT4 MH: 11.5 LT4 MH: 11.5 LT4 MH: 11.5 LT4 MH: 11.5 LT4 MH: 11.5 LT4 MH: 11.5 MH: 11.5 LT4 LT4 MH: 11.5 MH: 11.5 LT4LT4 MH: 11.5 MH: 5.7LT2 MH: 5.7LT2 LT5 MH: 15 LT3 MH: 8 LT3 MH: 8 LT2MH: 6.7 MH: 6.7 LT2 LT4 MH: 8.5 0.3 0.1 1.1 0.9 0.7 0.61.7 0.41.1 0.2 0.1 0.1 0.0 0.0 0.0 0.51.21.0 0.8 1.1 1.1 0.6 1.40.9 0.2 0.8 0.8 1.2 1.0 0.7 0.90.6 1.40.1 1.9 3.9 7.4 5.57.1 2.02.6 1.0 0.9 0.7 0.5 0.3 0.23.06.30.4 7.0 3.1 3.6 7.6 5.32.3 0.9 6.3 1.9 1.3 4.6 7.3 2.94.1 0.3 1.2 0.4 0.5 0.7 0.60.2 0.40.1 0.4 0.4 0.3 0.3 0.3 0.30.5 0.00.3 0.2 0.2 0.2 0.2 0.5 0.1 0.3 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.00.3 0.0 0.4 0.1 0.1 0.2 1.2 1.2 0.0 0.0 0.3 0.9 0.3 0.3 0.3 0.3 0.3 0.30.3 0.40.7 0.7 0.6 0.5 0.40.3 0.3 0.1 0.6 0.3 0.2 0.1 0.10.9 0.1 1.2 0.1 0.3 0.4 8.6 5.4 3.0 0.00.2 0.1 0.2 0.1 0.1 0.0 0.60.1 1.0 0.3 0.9 8.8 5.3 2.8 1.60.1 0.0 1.0 0.6 0.3 0.2 0.1 1.7 0.02.9 0.1 0.1 0.3 0.8 8.1 4.9 0.10.1 0.9 0.6 0.3 0.2 0.1 0.1 1.20.1 1.70.1 0.2 0.4 8.6 5.4 1.2 0.0 12.8 0.3 5.2 17.8 13.8 3.317.9 18.211.9 5.9 3.5 2.1 1.4 1.1 0.99.418.2 0.4 0.0 0.1 0.1 0.2 6.17.8 0.29.9 4.2 16.1 16.3 3.4 2.11.0 0.3 0.2 0.1 0.1 0.0 0.0 0.6 0.2 0.9 0.8 8.7 5.0 2.5 1.6 1.20.1 0.6 0.1 0.1 0.0 0.0 0.0 0.1 0.30.3 0.68.4 4.8 2.4 1.6 1.2 0.3 0.1 0.00.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.10.0 0.0 0.0 0.0 0.00.0 0.00.0 0.1 0.1 0.1 0.1 0.0 0.3 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.00.00.00.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.10.1 0.2 0.2 0.2 0.10.1 0.10.1 0.1 0.1 0.1 0.0 0.0 0.0 0.10.1 0.0 0.1 0.1 0.1 0.1 0.20.1 0.0 0.1 0.1 0.1 0.1 0.1 0.10.1 0.20.2 0.1 0.1 0.1 0.20.0 0.20.2 0.2 0.1 0.1 0.1 0.4 1.1 0.20.2 0.1 0.1 0.1 0.1 0.1 0.1 0.20.2 0.20.2 0.2 0.2 0.2 0.20.0 0.2 0.1 0.1 0.1 0.1 0.1 0.10.1 0.10.1 0.1 0.1 0.1 0.1 0.1 0.10.10.0 0.0 0.0 0.0 0.0 0.0 0.10.0 0.10.0 0.0 0.0 0.0 0.0 0.10.0 0.10.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.10.0 0.1 0.4 0.1 0.0 0.0 0.1 0.1 0.00.1 0.00.1 0.1 0.1 0.1 0.10.1 0.1 0.10.0 0.10.10.00.10.10.10.10.10.10.10.1 0.10.1 0.10.10.10.10.10.10.10.10.10.10.10.0 0.0 0.1 0.0 0.2 0.00.00.00.00.00.00.00.00.00.00.0 0.1 0.0 0.0 0.00.00.00.0 0.00.00.00.10.10.10.10.1 0.0 0.0 0.0 1.5 0.10.10.10.10.10.10.10.10.10.1 2.6 0.1 0.10.00.00.00.00.00.00.0 0.00.00.10.10.2 0.1 0.1 0.00.00.00.00.00.0 0.00.00.10.10.10.10.1 0.1 0.0 0.20.20.20.20.10.10.10.10.10.10.10.1 0.1 0.0 0.0 0.00.00.00.00.00.00.00.00.00.00.0 0.00.0 0.00.0 0.00.00.00.00.00.00.00.00.00.0 0.0 0.0 0.0 0.00.00.00.00.00.00.00.00.00.00.00.00.0 0.0 0.0 0.00.00.00.00.00.00.00.00.00.00.00.0 0.0 0.1 0.00.00.0 0.00.00.00.00.00.00.00.00.1 0.0 0.1 0.0 0.10.00.00.00.00.00.00.00.00.00.00.0 0.1 0.0 0.00.00.00.00.00.00.00.00.00.00.00.00.0 0.0 0.1 0.00.00.00.00.00.00.00.00.00.00.00.0 0.0 6.8 0.0 2.03.610.66.01.30.94.419.220.419.820.4 0.1 19.8 3.51.53.610.70.31.20.80.30.10.10.00.0 0.7 21.5 0.1 1.01.61.10.50.20.20.20.10.10.10.00.0 7.1 0.0 0.1 0.20.30.50.70.91.01.21.42.05.110.9 0.2 0.0 6.2 0.0 0.10.0 0.00.10.10.20.30.50.81.11.5 0.3 3.8 0.7 1.30.30.10.10.0 0.00.10.10.20.30.60.9 2.1 0.0 0.20.30.60.81.11.21.62.23.02.30.60.2 0.1 0.1 5.5 0.00.00.10.20.30.50.91.21.41.83.04.2 0.1 0.30.3 0.10.10.00.00.00.00.00.0 0.00.10.1 0.1 0.2 10.1 0.40.40.40.50.50.60.60.40.40.40.40.4 0.1 0.2 0.20.20.30.30.40.30.10.20.20.20.20.2 1.3 0.20.1 0.10.10.20.20.30.30.30.30.20.20.20.2 0.2 1.0 0.30.40.50.60.70.70.91.11.61.61.22.2 0.20.8 1.11.61.20.60.51.02.12.62.72.72.6 0.3 0.2 1.6 0.3 1.4 0.4 0.1 0.30.30.40.50.60.70.70.70.60.40.30.0 0.4 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.40.1 0.0 10.1 10.10.51.00.6 9.41.9 2.3 3.8 10.3 1.9 4.5 7.4 10.7 1.9 9.5 4.2 15.6 7.9 2.6 1.7 3.6 6.1 5.2 0.4 10.3 2.2 2.0 13.3 8.4 0.8 1.5 1.9 0.6 6.3 22.2 1.9 14.0 13.5 2.6 2.4 4.3 2.0 9.6 27.5 29.1 6.4 16.5 14.3 4.3 7.1 5.8 10.9 1.3 2.7 6.9 0.5 fc 1 fc 0.25 fc 0.25 fc0.1 fc 0.1 fc 0.5 fc1 fc PHOTOMETRIC PLAN DESIGNED BY ESL-SPECTRUMWWW.ESL-SPECTRUM.COM PHONE: 317.951.2300 ESL-Spectrum's services are for estimation purposes only, and are not warranties.Final design and illumination levels must be determined and specified by an electrical engineer.Field results may differ from computer predictions because of many uncontrollable factors and adverse test conditions such as:line voltage variations, lamp performance, product manufacturing tolerances, jobsite conditions, and other unrecoverable light-loss factors. THE FIXTURE TYPE(S) AND LAMPING(S) SPECIFIED ON THIS LAYOUT MUST BE USED IN ORDER TO MEET THE EXACT CRITERIA AND PERFORMANCE DATA SHOWN.IES RECOMMENDED ILLUMINANCE TARGETS USED WHERE APPLICABLE. CALCULATIONS ARE MAINTAINED HORIZONTAL ILLUMINANCE FIGURES IN FOOT-CANDLES POINTS SHOWN ARE AT GRADEFIXTURE MOUNTING HEIGHTS ARE SPECIFIED NEXT TO FIXTURES AS "MH" Calculation Summary Project: 20230119-HG LAKE CITY BANK CARMEL - SITE LIGHTING 6-13-23 Label CalcType Units Luminaire Schedule Project: 20230119-HG LAKE CITY BANK CARMEL - SITE LIGHTING 6-13-23 Symbol Qty Label Arrangement Avg Max Lum. Watts Lum. Lumens LLF Manufacturer Description4LT1Single2010700.850 WE-EF 117-0202 6 LT2 Single 31 1680 0.850 WE-EF 131-9877 2 LT3 Single 41 2878 0.850 WE-EF 131-9662 16 LT4 Single 28 2297 0.850 WE-EF 134-6207 1 LT5 Single 36.9 4662 0.850 BEACON RWL1-48L-35-4K7-4W-UNV Min Avg/Min Max/Min LANDSCAPE AREA_Grade Illuminance Fc 6.89 29.1 0.4 17.23 72.75 SITE_Grade Illuminance Fc 0.87 21.5 0.0 N.A.N.A. RENDER IMAGE 1: NTS RENDER IMAGE 2: NTS 07/21/2023 PAGE 16 BUIlDINg moUNteD SIgNAge tm crowley lAkE city bAnk 07/21/2023 ARTWORK APPROVED BY: APPROVAL DATE: C A R M E L - W E S T E L E V AT I O N PMS 541 BLUESCALE: 1/8”=1' & 1/4”=1’DATE: 06122023FILE: LCB Carmel W ElevChannel Letters B.cdrDue to the limitations of the printing process, printed colors can vary from actual colors.All drawings/designs/derivatives: 2023, Vanadco Signs, Inc., All Rights Reserved. Individual Internally Illuminated LED Channel Letters Black Trim Cap, Black Returns and 3M Dual Color Perforated Black Vinylon White Faces (Lights White an Night) 60.7 Sq Ft38"24" 230" PAGE 17 moNUmeNt SIgN tm crowley lAkE city bAnk 07/21/2023 18"4'-0" 1'-8" ARTWORK APPROVED BY: APPROVAL DATE: C A R M E L PMS 541 BLUESCALE: 1/2”=1’DATE: 061223 Rev. 071923FILE: LCB Carmel Monument B.cdr Due to the limitations of the printing process, printed colors can vary from actual colors.All drawings/designs/derivatives: 2023, Vanadco Signs, Inc., All Rights Reserved. Internally Illuminated Monument Sign - Routed Faces with Push-Through LogoSurface Applied Vinyl Graphics Translucent PMS 541 Blue Logo & 3M Dual Color Perforated Black Vinyl on Letters 3’-6" 3"6” 6'-0"