Loading...
HomeMy WebLinkAboutCHWA201withCanopy 4-12-23820 City Center Drive Carmel, Indiana 46032Project No. 1131-0105/21/2021CARMEL HEALTH & WELLNESS COMPLEXSTATE OFIADINNA R IGE TSEREDRACHITECT No. 19300053ELDWODL.H P E S OJ 1ADDENDUM #106/17/2021REVISIONSA201EXTERIOR ELEVATIONSNORTH ELEVATIONSCALE: 1/8" = 1'-0"1SOUTH ELEVATIONSCALE: 1/8" = 1'-0"2EAST ELEVATION (EXISTING BUILDING)SCALE: 1/8" = 1'-0"4WEST ELEVATIONSCALE: 1/8" = 1'-0"3T. FRAMING18'-0"FINISH FLOOR0'-0"T. CANOPY10'-0"T. SCREEN18'-0"FINISH FLOOR0'-0"T. ROOF DECK10'-0"T. EXISTING BUILDING26'-9"FINISH FLOOR0'-0"T. EXISTING BUILDING26'-9"18'-0"T. ROOF DECK10'-0"FINISH FLOOR0'-0"T. EXISTING BLOCK23'-4"T. CANOPY10'-0"FINISH FLOOR0'-0"T. FRAMING18'-0"T. EXISTING BLOCK23'-4"FINISH FLOOR0'-0"NEWEXIST.NEWEXIST.12"1/2"12"1/2"08 41 13.AT. WINDOW13'-0"T. MECH. SCREEN100AW104 20 00.J13 34 19.DPRECAST SILLPRECAST SILL13 34 19.DPRECAST SILLW1W1W1W1W1W1W1A3011A3012A3021A3022A3002A3001W4W5W3W6W7110C110BNOTE:REFER TO A020 FOR EXTERIOR WALL,FLOOR & ROOF SYSTEM DETAILS.REFER TO A021 FOR INTERIOR WALL TYPESREFER TO A501 FOR:DOOR SCHEDULE & DETAILSOPENING DESIGNATIONDIVISION 3 - CONCRETE03 30 00.AFOOTING - SEE STRUCTURAL DRAWINGS FOR SIZE & REINFORCING INFORMATION03 30 00.BCONCRETE SLAB - SEE STRUCTURAL03 30 00.CCOMPRESSIBLE JOINT FILLER03 30 00.DFORMED CONCRETE POOL,SEE AQ DRAWINGSDIVISION 4 - MASONRY04 20 00.A EXISTING MASONRY 04 20 00.BCONCRETE MASONRY UNIT - SIZE AS NOTED04 20 00.CMORTAR NET04 20 00.DSELF-ADHESIVE FLEXIBLE SHEET FLASHING04 20 00.EADJUSTABLE MASONRY VENEER ANCHOR @16" O.C. VERTICALLY04 20 00.FFLASHING TERMINATION BAR04 20 00.GEXPANSION JOINT, 3/8"04 20 00.H VENT @ 4'-0" O.C. & WHEREINDICATED04 20 00.JDECORATIVE CONCRETE MASONRY FACEBLOCKDIVISION 5 - METALS05 12 00.ASTRUCTURAL STEEL FRAMING MEMBER REF. STRUCTURAL DRAWINGS.05 21 00.ASTEEL JOIST - SEE STRUCTURAL05 31 00.ASTRUCTURAL DECKING - REF. STRUCTURAL DRAWINGS05 40 00.A8" COLD FORMED METAL STUD @ 16" O.C.DIVISION 6 - WOOD AND PLASTIC06 10 00.ASHIM OR WOOD BLOCK AS REQUIRED06 10 00.B2X PRESSURE TREATED WOOD BLOCKING06 10 00.C3/4" TREATED PLYWOOD06 16 00.A 5/8" GLASS - MAT SHEATHING06 40 00.APLAM COUNTER WITH CONCEALED BRACKETS06 40 00.BPLAM RECEPTION DESKDIVISION 7 - THERMAL AND MOISTURE PROTECTION07 14 16.AFLUID APPLIED WATERPROOFING07 21 00.A3" POLYISO INSULATION07 21 00.BCLOSED CELL FOAM INSULATION07 21 00.CACOUSTICAL INSULATION07 27 26.AFLUID APPLIED IMPERMEABLE AIR & VAPORBARRIER.07 27 26.BIMPERMEABLE FLASHING07 53 23.AEPDM ROOFING MEMBRANE07 53 23.B4" POLYISO INSULATION07 53 23.CTAPERED POLYISO INSULATION07 53 23.D1/2" PROTECTION BOARD07 53 23.EVAPOR BARRIER07 62 00.A PREFINISHED METAL COPING07 62 00.BCOUNTER FLASHING07 62 00.C1/8" ALUMINUM BRAKE METAL TRIM07 92 00.AJOINT SEALANT & BACKER ROD07 95 00.AEXPANSION JOINT COVERDIVISION 8 - DOORS AND WINDOWS08 11 00.A STEEL DOOR & FRAME08 41 13.AALUMINUM STOREFRONT SYSTEMKAWNEER TRIFAB 451 UT WITHINSULPOUR DOORS08 41 13.BEXTERIOR SILL TRIM08 41 13.CINTERIOR SILL TRIM08 41 13.DALUMINUM STOREFRONT WALL TRIM08 44 13.AALUMINUM CURTAINWALL SYSTEMKAWNEER 1600 SYSTEM 1, 6" DEEP08 71 00.ATHRESHOLD08 80 00.AINSULATED GLASS08 90 00.ALOUVERED MECHANICAL SCREENDIVISION 9 - FINISHES09 22 16.A3-5/8" 25 GA. METAL STUD09 22 16.B7/8" METAL FURRING CHANNELS @ 16" O.C.09 29 00.A5/8" TYPE X GYPSUM BOARD09 30 00.ATILE FINISH09 51 13.AACOUSTICAL PANEL CEILINGS09 65 13.ARESILIENT BASE09 65 19.ALVT FLOORING09 68 13.AWALK OFF CARPET09 91 13.AEXTERIOR PAINTED FINISH09 91 23.AINTERIOR PAINTED FINISH09 91 23.BHIGH PERFORMANCE COATING OVER EXISTING CONCRETE TRIM09 96 11.AHIGH PERFORMANCE COATINGDIVISION 10 - SPECIALTIES10 14 19.ADIMENSIONAL LETTER SIGN - PROVIDED BYTENANT, INSTALLED BY G.C.10 14 23.APANEL SIGN - PROVIDED BY TENANT, INSTALLED BY G.C.10 21 13.ATOILET COMPARTMENTSDIVISION 13 - SPECIAL CONSTRUCTION13 34 19.APEMB STRUCTURAL STEEL13 34 19.BPEMB GIRT13 34 19.C6" R49 ROOF PANEL BY PEMB SUPPLIER13 34 19.D4" R31 WALL PANEL BY PEMB SUPPLIER13 34 19.EEXPANSION JOINT SYSTEM BY PEMB13 34 19.FROOF TRIM AND GUTTER SYSTEM BY PEMBKEYNOTESXXXXXX08 41 13.A(VESTIBULE)10 14 19.A04 20 00.J04 20 00.J08 41 13.AA3001A3003A3002A3003COORDINATE WITH EXIST.MECHANICAL UNIT SIZE &CLEARANCE REQUIREMENTS.04 20 00.J13 34 19.C13 34 19.D13 34 19.C08 41 13.A08 90 00.ACOORDINATE WITH EXIST.MECHANICAL UNIT SIZE &CLEARANCE REQUIREMENTS.08 90 00.ACOORDINATE WITH EXIST.MECHANICAL UNIT SIZE &CLEARANCE REQUIREMENTS.08 90 00.ACOORDINATE WITH EXIST.MECHANICAL UNIT SIZE &CLEARANCE REQUIREMENTS.08 90 00.A08 90 00.ASEE MECHANICAL DRAWINGFOR UNIT SIZE. PROVIDEREQUIRED CLEARANCE FORMAINTENANCE.08 90 00.ASEE MECHANICAL DRAWINGFOR UNIT SIZE. PROVIDELOUVERED PANEL ON EASTAND WEST ELEVATION.COORDINATE WITH EXIST.MECHANICAL UNIT SIZE &CLEARANCE REQUIREMENTS.08 90 00.ACOORDINATE WITH EXIST.MECHANICAL UNIT SIZE &CLEARANCE REQUIREMENTS.08 90 00.ACOORDINATE WITH EXIST.MECHANICAL UNIT SIZE &CLEARANCE REQUIREMENTS.08 90 00.A08 90 00.ASEE MECHANICAL DRAWINGSFOR UNIT SIZE. PROVIDELOUVERED PANEL ON EASTAND WEST ELEVATION.08 90 00.ASEE MECHANICAL DRAWINGS.FOR UNIT SIZE. PROVIDE 4'-0"MIN REQUIRED CLEARANCEFOR MAINTENANCE.08 90 00.ASEE MECHANICAL DRAWINGS.FOR UNIT SIZE. PROVIDE 4'-0"MIN REQUIRED CLEARANCEFOR MAINTENANCE.09 91 13.A PAINT NEWELECTRICAL BOXES TOMATCH EXISTING,ADJACENT FINISH.ALTERNATE:PROVIDE ALTERNATE PRICINGTO INSTALL VAPOR BARRIER,FURRING AND METAL PANESON EXISTING WEST WALL.ALTERNATE:PROVIDE ALTERNATE PRICINGTO INSTALL VAPOR BARRIER,FURRING AND METAL PANESON EXISTING WEST WALL.T. EXISTING BLOCK23'-4"3ADDENDUM #308/02/20213SIGNAGE PERPermit #: S-2023-00011 4ASI #5 10/25/202208 41 13.A(ENTRY BEYOND)