Loading...
HomeMy WebLinkAbout12410 Windsor Dr. Permit Set 7.19.23.pdfMELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision: SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917MELTZER RESIDENCE VICINITY MAP PROJECT TEAM ARCHITECTURAL DESIGNER: Peter Meehan, 847.702.2917 peter@customlivingusa.com PROJECT MANAGER: Anthony Giannamore, 317.879.6685 anthony@customlivingusa.com INTERIOR DESIGNER: Name, Cell Phone # email BROOKSHIRE NEIGHBORHOOD 12410 Windsor Dr Carmel, IN 46033 Year Built: 1973 Total Existing Square Feet: 3381 SF Single Story Finished Basement REMODEL SQUARE FOOTAGE: 643 SF SCOPE OF WORK: Rebuild attached garage, same as existing, following tree damage to structure. Replace front door and windows following tree damage to structure. TABLE OF CONTENTS SHEET NO.PAGE C1 COVER PAGE A1 EXISTING/DEMO PLAN A2 PROPOSED PLAN A3 EXTERIOR ELEVATIONS A4 STRUCTURAL DETAILS M1 M.E.P. PLAN C1N NEXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING 16070DN FLOOR JOIST DIRECTIONFLOOR JOIST DIRECTIONFLOOR JOIST DIRECTION22'-8"23'-4"22'-8" 68'-8"7'-4"22'-9 3/4"18'-8"21'-4"22'10'-4"2'-1"3'-1"5'-6"13'-6"6'5' 13'8'-0 1/2"6'-10"5'-7"4'4'-4"13'-3 7/8"12'2'-1"15'-4 1/2"17'48'-8"2'-9"CL 4' CL 11'-8"CL 4' CL 10'-7 1/2" CL 10'-0 1/2"48'-8"D1D1 D4D4 D2D2E2E2 H2H2 PULL DOWN STAIR DINING ROOM 8' - 1-1/2" C.H. AFF HARDWOOD NOOK 8' - 1-1/2" C.H. AFF HARDWOOD KITCHEN 8'-1 1/2" C.H. AFF HARDWOOD LAUNDRY 8'-1 1/2" C.H. AFF BATH 8'-1 1/2" C.H. AFF ENTRY VAULTED C.H. AFF TILE PRIMARY BEDROOM 8' - 1-1/2" C.H. AFF CARPET BEDROOM 2 8' - 1-1/2" C.H. AFF CARPET BEDROOM 3 8' - 1-1/2" C.H. AFF CARPET HALLWAY 8' - 1-1/2" C.H. AFF CARPET BATHROOM 8' - 1-1/2" C.H. AFF DRESSING ROOM 8' - 1-1/2" C.H. AFF CARPET CLOSET 8' - 1-1/2" C.H. AFF CARPET BATHROOM 8' - 1-1/2" C.H. AFF CARPET GREAT ROOM VAULTED C.H. AFF HARDWOOD LINEN DECK GARAGE 8' - 1-1/2" C.H. AFF CONCRETE COURTYARD D2D2D3D3 D5D5 D6D6 DEMO & PREP PLAN NOTES NOTE QTY DESCRIPTION 1 REMOVE ALL EXISTING APPLIANCES (SAVE) 2 DEMO EXISTING WINDOW UNIT, PREPARE OPENING FOR NEW REPLACEMENT WINDOW UNIT. 1 DEMO EXISTING DOOR UNIT, PREPARE OPENING FOR NEW REPLACEMENT DOOR UNIT. 1 WALLS HATCHED IN RED WERE REMOVED DUE TO TREE DAMAGE DONE TO HOUSE. 1 WALL BETWEEN GARAGE AND HOUSE REMAINS. ROOF STRUCTURE ABOVE REMAINS. REPLACE AND/OR SISTER ON EXISTING ROOF RAFTERS AS RECOMMENDED BY STRUCTURAL ENGINEER. 1 DEMO WALL SECTION, PREPARE OPENING FOR NEW WINDOW UNIT. D1D1 D2D2 D3D3 D4D4 D5D5 D6D6 D1D1 D2D2 D3D3 D4D4 D5D5 D6D6 PLUMBING DEMO/DISCONNECT PLAN NOTES NOTE QTY DESCRIPTION 1 SEPARATE PLUMBING PERMIT NOT REQUIRED. 1 NO CURRENT PLUMBING SCOPE OF WORK. P1P1 P2P2 P1P1 P2P2 ELECTRICAL DEMO/DISCONNECT NOTES NOTE QTY DESCRIPTION 1 SEPARATE ELECTRICAL PERMIT NOT REQUIRED. 1 DISCONNECT ALL GARAGE ELECTRICAL DAMAGED BY TREE. EVALUATTE CIRCUITS TO GARAGE FOR REPAIR. E1E1 E2E2 E1E1 E2E2 GENERAL NOTES NOTE QTY DESCRIPTION 1 DUMPSTER AND PORTALET LOCATIONS TO BE DETERMINED ON SITE W/ HOMEOWNERS 1 (TEMPLATE) HOMEOWNERS TO MOVE ALL NECESSARY FURNITURE FROM AREAS OF REMODEL PRIOR TO START OF WORK 1 (TEMPLATE) HOMEOWNERS TO REMOVE ALL WINDOW COVERINGS PRIOR TO START OF WORK 1 (TEMPLATE) HOMEOWNERS TO CLEAR OUT SPACE IN GARAGE FOR STORAGE OF BUILDING MATERIALS PRIOR TO START OF WORK. GN1GN1 GN2GN2 GN3GN3 GN4GN4 GN1GN1 GN2GN2 GN3GN3 GN4GN4 HVAC DEMO/DISCONNECT NOTES NOTE QTY DESCRIPTION 1 SEPARATE HVAC PERMIT NOT REQUIRED. 1 EXISITNG HOOD DUCT TO REMAIN BE REPAIRS DURING MECHANICAL ROUGH-INS H1H1 H2H2 H1H1 H2H2 MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision: SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917GENERAL SITE PREP & DEMO NOTES Install plastic to seal off areas being remodeled from rest of home as necessary. Install floor covering for construction path from door designated as the construction entrance to locations of remodeling as necessary. Install additional floor covering or wall protection as needed over areas close to the areas of construction activity. Install dust control measures on HVAC cold air returns located within the locations of remodeling. Custom Living can provide a HEPA Air Scrubber to aid in airborne dust control from the start of demolition up to priming of new drywall depending on site conditions. Homeowner understands that this will help to reduce airborne dust; however, it will not mitigate it in its entirety. Demolition Contractor(s) are responsible for all labor, for the scope of work specified in the drawings provided by Custom Living. Homeowner understands that Custom Living has only provided a labor and material allowance for the scope of demolition denoted on the drawings. Any additional scope added or uncovered during demolition result in filing a Change Order during construction. Homeowners understand that demolition work will generate dust and noise throughout the house. Custom Living will provide site protection measures to reduce where possible, but Homeowners should not expect 100% containment. EXISTING / DEMO PLAN SCALE: 1/4" = 1'A1 SB3021B15LCB36R3DB24SB36DWB27B27 B36B36B36SB3021B15LCB36R3DB24SB36DWB27B27 B36B36B36HB D02 D01 W02 W04 W01D03W01 W03 DN FLOOR JOIST DIRECTIONFLOOR JOIST DIRECTIONFLOOR JOIST DIRECTIONH / ACH / AC H / AC CEILING WP CO/SD SD SD SD SD E1 A3 E1 A3 Elevation 1 E2 A3 E2 A3 Elevation 221'-4"22'10'-0 1/2"25'-0 1/2"18'-4 1/2"24'-1 1/8" CL 10'-1"CL1'-11"CL10'-8"10'-8" CL 9'-5" CL5'-3 1/4"F1F1 BM1BM1 I3I3 I2I2 D2D2 D3D3 F2F2 DINING ROOM 8' - 1-1/2" C.H. AFF HARDWOOD NOOK 8' - 1-1/2" C.H. AFF HARDWOOD KITCHEN 8'-1 1/2" C.H. AFF HARDWOOD LAUNDRY 8'-1 1/2" C.H. AFF BATH 8'-1 1/2" C.H. AFF ENTRY VAULTED C.H. AFF TILE PRIMARY BEDROOM 8' - 1-1/2" C.H. AFF CARPET BEDROOM 2 8' - 1-1/2" C.H. AFF CARPET BEDROOM 3 8' - 1-1/2" C.H. AFF CARPET HALLWAY 8' - 1-1/2" C.H. AFF CARPET BATHROOM 8' - 1-1/2" C.H. AFF DRESSING ROOM 8' - 1-1/2" C.H. AFF CARPET CLOSET 8' - 1-1/2" C.H. AFF CARPET BATHROOM 8' - 1-1/2" C.H. AFF CARPET GREAT ROOM VAULTED C.H. AFF HARDWOOD LINEN DECK GARAGE 9' - 1-1/2" C.H. AFF CONCRETE COURTYARD PULL DOWN STAIR F3F3 F4F4 F5F5 F2F2 F6F6 ST1ST1 ST1ST1 ST2ST2 ST3ST3 EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING EXTERIOR DOOR SCHEDULE - 1ST FLOOR NUMBER FLOOR DESCRIPTION QTY R/O SUPPLIER D01 1 HINGED 1 38"X86 1/4" D02 1 GARAGE-SLAB 1 194"X87" D03 1 DOUBLE HINGED 1 55"X82 1/4" WINDOW SCHEDULE - 1ST FLOOR NUMBER FLOOR DESCRIPTION QTY R/O TOP EGRESS TEMPERED SUPPLIER W01 1 DOUBLE CASEMENT 2 30"X59"87" W02 1 DOUBLE CASEMENT 1 40"X59"94 1/8" W03 1 FIXED GLASS 1 57"X20"80" W04 1 DOUBLE CASEMENT 1 40"X59"80" FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 FRAME NEW EXTERIOR GARAGE WALLS AS SHOWN ON TOP OF EXISTING GARAGE FOUNDATION. 2 FRAME NEW WINDOW ROUGH OPENING PER WINDOW SPECIFICATIONS. INSTALL NEW WINDOW UNITS IN NEW OPENINGS. 1 FRAME NEW GARAGE DOOR ROUGH OPENING PER GARAGE DOOR SPECIFICATIONS AND STRUCTURAL ENGINEER REQUIREMENTS. GARAGE DOOR COMPANY TO INSTALL GARAGE DOOR. 1 FRAME NEW DOOR ROUGH OPENING PER DOOR SPECIFICATIONS AND STRUCTURAL ENGINEER REQUIREMENTS. INSTALL NEW EXTERIOR DOOR IN NEW ROUGH OPENING. 1 FRAME NEW HIP ROOF SYSTEM SAME AS ORIGINAL DESIGN. 1 FRAME NEW ATTIC ACCESS OPENING IN CEILING RAFTERS. PREP FOR ATTIC PULL DOWN STAIRS SIMILAR TO EXISTING ORIGINAL ACCESS. F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRECAULK ALL MECHANICAL OPENINGS PER MUNICIPAL CODE REQUIREMENTS 1 INSTALL NEW BLOWN FIBERGLASS INSULATION IN ENTIRE ATTIC ABOVE GARAGE, KITCHEN, AND DINING ROOM AREAS. 1 INSTALL NEW R-15 FIBERGLASS BATT INSULATION IN ALL NEW EXTERIOR WALLS AND WALL BETWEEN GARAGE AND HOUSE. I1I1 I2I2 I3I3 I1I1 I2I2 I3I3 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 EXISTING INTERIOR DRYWALL FINISH NOTES; (WALLS) SMOOTH-LEVEL 4, (CEILINGS) SMOOTH-LEVEL 4 1 INSTALL NEW DRYWALL ON ALL NEWLY FRAMED WALLS. PATCH ALL AREAS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. MATCH EXISTING DRYWALL FINISH. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. 1 INSTALL NEW DRYWALL ON ALL CEILINGS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. MATCH EXISTING CEILING FINISH IN HOME. GARAGE CEILING DRYWALL TO BE KNOCK DOWN TEXTURE. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. D1D1 D2D2 D3D3 D1D1 D2D2 D3D3 EXTERIOR SIDING & TRIM NOTES NOTE QTY DESCRIPTION 2 MATCH WINDOW TRIM TO OTHER EXISTING WINDOWS. TRIM IS 1X8 ROUGH CEDAR APPLIED OVER BRICK. MATCH ANGLE DETAIL FOR WINDOW LINTEL. 1 GARAGE DOOR TRIM TO BE ROUGH SAWN CEDAR 1 ALL SOFFIT AND GUTTER BOARD TO BE ROUGH SAWN CEDAR TO MATCH EXISTING. ST1ST1 ST2ST2 ST3ST3 ST1ST1 ST2ST2 ST3ST3 BRICK & MASONRY PLAN NOTES NOTE QTY DESCRIPTION 1 NEW BRICK VENEER TO BE INSTALLED ON NEWLY FRAMED WALLS. FINAL SCOPE TO BE DETERMINED FOLLOWING DEMO. MATCH EXISTING BRICK DETAILS WITH SOLDIER COURSE ACROSS THE TOP OF WALL AND QUOINS ON FRONT CORNERS. BM1BM1BM1BM1 NMELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision: SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Order during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. PROPOSED FLOOR PLAN SCALE: 1/4" = 1'A2 SOUTH ELEVATIONE3E3 WEST ELEVATIONE4E4 FRONT ELEVATIONE1E1 SIDE ELEVATIONE2E2 MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision: SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917EXTERIOR ELEVATIONS & DETAILS SCALE: 1/2" = 1' ***VERIFY SCALE ACCURACY A3 TTTTTTT VENTED SOFFIT WOOD FRIEZE BOARD MASONRY TIE BRICK VENEER ASPHAULT SHINGLE ROOF ROOFING MEMBRANE FLASHING FASCIA 2x8 RAFTERS @ 16" O.C. 2x8 CEILING JOISTS @ 16" O.C. GUTTER EXISTING CONCRETE SLAB EXISTING 4" COMPACTED GRAVEL BASE 2X4 TREATED SILL PLATE 1/2" ANCHOR BOLT @ 6' O.C. SILL SEAL EXISTING 8" CMU FOUNDATION WALL EXISTING GARAGE FOOTING 4" BRICK VENEER WEEP HOLES 1" AIR GAP 2x4 DOUBLE TOP PLATE 2X4 WALL STUDS @ 16" O.C. 3/4" OSB SHEATHING BRICK LEDGE GRADE 9'-1 1/2" CEILING HEIGHT 1'-4"9'-1 1/2"HEADER- DOUBLE 2X8 (UNLESS NOTED OTHERWISE) DOUBLE TOP PLATE KING STUD CRIPPLE STUD TREATED BOTTOM PLATE O.C. 4" CONCRETE SLAB EXISTING 2X8 CEILING JOISTS @ 16" O.C.MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision: SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917WALL SECTIONS & STRUCTURAL FRAMING DETAILS A4 WALL SECTION SCALE: 2" = 1'TYPICAL WALL FRAMING SCALE: 1/2" = 1' REFRIGERATOR OUTLET MICROWAVE OUTLET DISHWASHER POWER SUPPLY HOOD VENT POWER SUPPLY GARBAGE DISPOSAL POWER SUPPLY COOKTOP POWER SUPPLY CLOTHES DRYER OUTLET CLOTHES WASHER OUTLET 110V OUTLET 220/240V OUTLET GFCI OUTLET OUTDOOR OUTLET LOW VOLTAGE TRANSFORMER SINGLE POLE SWITCH DIMMER SWITCH 3-WAY SWITCH 4-WAY SWITCH GD WALL SWITCH GD COUNTERTOP AIR SWITCH LOW VOLTAGE LIGHTING SWITCH TIMER SWITCH OCCUPANCY SWITCH SURFACE MOUNT LIGHT FIXTURE 4" RECESSED CAN LIGHT 6" RECESSED CAN LIGHT 6" RECESSED CAN/FAN UNIT EXHAUST FAN ONLY EXHAUST FAN W/ LIGHT WALL MOUNTED SCONCE / LIGHT CEILING FAN LOW VOLTAGE LIGHT SMOKE DETECTOR CARBON MONOXIDE DETECTOR SMOKE/CARBON MONOXIDE MOTION SENSOR CEILING SPEAKER GAS SHUT-OFF KEY MAIN WATER SHUT-OFF LAUNDRY BOX FROST PROOF HOSE BIB CLEAN OUT TILE-IN DRAIN FLOOR DRAIN COLD AIR RETURN FLOOR FLOOR SUPPLY REGISTER CEILING CEILING SUPPLY REGISTER WALL WALL SUPPLY REGISTER EXTERIOR WALL EXHAUST VENT T THERMOSTAT DRYER BOX ELECTRICAL KEY PLUMBING KEY HVAC KEY HB DNH / ACH / AC H / AC CEILING WP CO/SD SD SD SD SD LV1LV1 H1H1 E1E1 E7E7 E6E6 E5E5 E4E4 DINING ROOM 8' - 1-1/2" C.H. AFF HARDWOOD NOOK 8' - 1-1/2" C.H. AFF HARDWOOD KITCHEN 8'-1 1/2" C.H. AFF HARDWOOD LAUNDRY 8'-1 1/2" C.H. AFF BATH 8'-1 1/2" C.H. AFF ENTRY VAULTED C.H. AFF TILE PRIMARY BEDROOM 8' - 1-1/2" C.H. AFF CARPET BEDROOM 2 8' - 1-1/2" C.H. AFF CARPET BEDROOM 3 8' - 1-1/2" C.H. AFF CARPET HALLWAY 8' - 1-1/2" C.H. AFF CARPET BATHROOM 8' - 1-1/2" C.H. AFF DRESSING ROOM 8' - 1-1/2" C.H. AFF CARPET CLOSET 8' - 1-1/2" C.H. AFF CARPET BATHROOM 8' - 1-1/2" C.H. AFF CARPET GREAT ROOM VAULTED C.H. AFF HARDWOOD LINEN DECK GARAGE 9' - 1-1/2" C.H. AFF CONCRETE COURTYARD E7E7 E6E6 E8E8 E10E10 E9E9 NPROPOSED ELECTRICAL PLAN NOTES NOTE QTY DESCRIPTION 1 VERIFY EXISTING SMOKE AND CO DETECTORS MEET CURRENT CODE REQUIREMENTS. HOMEOWNERS UNDERSTAND THAT IF EXISTING FIXTURES NEED TO BE BROUGHT UP TO CODE, THERE WILL BE AN ADDITIONAL COST. THIS WILL BE DETERMINED ON A FIELD WALK. 1 VERIFY ALL INSTALLED GFCI OUTLETS MEET CURRENT CODE REQUIREMENTS. 1 VERIFY EXISTING PANEL SIZING WILL SUPPORT PROPOSED ELECTRICAL. HOMEOWNERS UNDERSTAND IF THE PANEL NEEDS TO BE UPDATED, THERE WILL BE AN ADDITIONAL COST. 1 REFEED 220 V CIRCUIT FOR DRYER. 1 PROVIDE ROUGH IN AND FINISH FOR (1) SWITCH IN EXISTING LOCATION AS SHOWN CONNECTED TO (2) NEW KEYLESS BULB FIXTURES AS SHOWN. DEVICE STYLE AND COLOR SHOWN. ALL SWITCHES TO BE STANDARD HEIGHT U.N.O. ALL SPECIALTY DEVICES AS SHOWN ON PRINTS. 2 PROVIDE ROUGH IN AND FINISH FOR (6) INTERIOR WALL OUTLETS IN NEW LOCATIONS AS SHOWN. PROVIDE ROUGH IN AND FINISH FOR (1) INTERIOR CEILING OUTLETS IN NEW LOCATIONS AS SHOWN. PROVIDE ROUGH IN AND FINISH FOR (1) EXTERIOR WALL OUTLETS IN NEW LOCATIONS AS SHOWN. DEVICE STYLE AND COLOR SHOWN. ALL OUTLETS TO BE STANDARD HEIGHT U.N.O. ALL DEVICES TO BE STANDARD OUTLETS U.N.O. (CALL OUT ANY SPECIALTY OUTLET LOCATIONS OR DEVICES IN SEPARATE NOTES) 2 PROVIDE FINISH FOR (5) EXTERIOR COACH LIGHTS IN EXISTING LOCATIONS AS SHOWN. FIXTURES TO BE PROVIDED BY HOMEOWNERS. HOMEOWNERS UNDERSTAND THE TYPE OF FIXTURE SELECTED MAY HAVE AN EFFECT ON INSTALLATION COST. 1 PROVIDE ROUGH IN AND FINISH FOR (1) NEW EXTERIOR MOTION FLOOD LIGHT AT CORNER OF GARAGE WALL. WIRED TO BE HOT. 1 REFEED DEDICATED CIRCUIT TO REFRIGERATOR. 1 VERIFY ELECTRICAL CIRCUITS IN BACK HALLWAY ARE ACTIVE AND WORKING. E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E7E7 E8E8 E9E9 E10E10 E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E7E7 E8E8 E9E9 E10E10 PROPOSED LOW VOLTAGE PLAN NOTES NOTE QTY DESCRIPTION 1 ADJUST WIRING OF DOORBELL DEPENDING ON NEW FRONT DOOR INSTALLATION. LV1LV1LV1LV1 PROPOSED HVAC PLAN NOTES NOTE QTY DESCRIPTION 1 REWORK HOOD EXHAUST PIPING TO MEET CODE.H1H1H1H1 PROPOSED PLUMBING PLAN NOTES NOTE QTY DESCRIPTION 1 NO CURRENT PLUMBING SCOPE.P1P1P1P1 MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision: SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917PROPOSED M.E.P. PLAN SCALE: 1/4" = 1'M1 GENERAL M.E.P NOTES HVAC Contractor is responsible for engineering calculation necessary for correct sizing of new equipment and ductwork being supplied, fabricated and installed for the project. HVAC ductwork installed in unconditioned areas to be insulated and sealed per Building Code Standards. HVAC contractor to start, test, and balance any new equipment and ductwork to assure proper operation of new systems. Final plumbing materials selected may have an affect on the final Plumbing Material and Installation Budgets. Owners understand that if additional plumbing, electrical or ductwork is found in walls being deleted that is not included on the plans there will be a Change Order during construction to relocate as necessary. Owners understand that during mechanical rough-ins there will be times when the water service will be shut off to areas in the home. Plumbing and Lighting fixtures supplied by Owner will not be warranted by Custom Living Plumbing and Lighting fixtures supplied by Owner must be selected and on-site prior to start of mechanical rough-ins.