HomeMy WebLinkAbout12410 Windsor Dr. Permit Set 7.19.23.pdfMELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision:
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917MELTZER RESIDENCE
VICINITY MAP PROJECT TEAM
ARCHITECTURAL DESIGNER:
Peter Meehan, 847.702.2917
peter@customlivingusa.com
PROJECT MANAGER:
Anthony Giannamore, 317.879.6685
anthony@customlivingusa.com
INTERIOR DESIGNER:
Name, Cell Phone #
email
BROOKSHIRE NEIGHBORHOOD
12410 Windsor Dr
Carmel, IN 46033
Year Built: 1973
Total Existing Square Feet: 3381 SF
Single Story
Finished Basement
REMODEL SQUARE FOOTAGE:
643 SF
SCOPE OF WORK:
Rebuild attached garage, same as
existing, following tree damage to
structure.
Replace front door and windows
following tree damage to structure.
TABLE OF CONTENTS
SHEET NO.PAGE
C1 COVER PAGE
A1 EXISTING/DEMO PLAN
A2 PROPOSED PLAN
A3 EXTERIOR ELEVATIONS
A4 STRUCTURAL DETAILS
M1 M.E.P. PLAN
C1N
NEXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
16070DN
FLOOR JOIST DIRECTIONFLOOR JOIST DIRECTIONFLOOR JOIST DIRECTION22'-8"23'-4"22'-8"
68'-8"7'-4"22'-9 3/4"18'-8"21'-4"22'10'-4"2'-1"3'-1"5'-6"13'-6"6'5'
13'8'-0 1/2"6'-10"5'-7"4'4'-4"13'-3 7/8"12'2'-1"15'-4 1/2"17'48'-8"2'-9"CL
4'
CL
11'-8"CL
4'
CL 10'-7 1/2"
CL
10'-0 1/2"48'-8"D1D1
D4D4
D2D2E2E2
H2H2
PULL DOWN STAIR
DINING ROOM
8' - 1-1/2" C.H. AFF
HARDWOOD
NOOK
8' - 1-1/2" C.H. AFF
HARDWOOD
KITCHEN
8'-1 1/2" C.H. AFF
HARDWOOD
LAUNDRY
8'-1 1/2" C.H. AFF
BATH
8'-1 1/2" C.H. AFF
ENTRY
VAULTED C.H. AFF
TILE
PRIMARY BEDROOM
8' - 1-1/2" C.H. AFF
CARPET
BEDROOM 2
8' - 1-1/2" C.H. AFF
CARPET
BEDROOM 3
8' - 1-1/2" C.H. AFF
CARPET
HALLWAY
8' - 1-1/2" C.H. AFF
CARPET
BATHROOM
8' - 1-1/2" C.H. AFF
DRESSING ROOM
8' - 1-1/2" C.H. AFF
CARPET
CLOSET
8' - 1-1/2" C.H. AFF
CARPET
BATHROOM
8' - 1-1/2" C.H. AFF
CARPET
GREAT ROOM
VAULTED C.H. AFF
HARDWOOD
LINEN
DECK
GARAGE
8' - 1-1/2" C.H. AFF
CONCRETE COURTYARD
D2D2D3D3
D5D5
D6D6
DEMO & PREP PLAN NOTES
NOTE QTY DESCRIPTION
1 REMOVE ALL EXISTING APPLIANCES (SAVE)
2
DEMO EXISTING WINDOW UNIT, PREPARE
OPENING FOR NEW REPLACEMENT WINDOW
UNIT.
1
DEMO EXISTING DOOR UNIT, PREPARE
OPENING FOR NEW REPLACEMENT DOOR
UNIT.
1 WALLS HATCHED IN RED WERE REMOVED
DUE TO TREE DAMAGE DONE TO HOUSE.
1
WALL BETWEEN GARAGE AND HOUSE
REMAINS. ROOF STRUCTURE ABOVE
REMAINS. REPLACE AND/OR SISTER ON
EXISTING ROOF RAFTERS AS
RECOMMENDED BY STRUCTURAL
ENGINEER.
1 DEMO WALL SECTION, PREPARE OPENING
FOR NEW WINDOW UNIT.
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
PLUMBING DEMO/DISCONNECT PLAN NOTES
NOTE QTY DESCRIPTION
1 SEPARATE PLUMBING PERMIT NOT
REQUIRED.
1 NO CURRENT PLUMBING SCOPE OF WORK.
P1P1
P2P2
P1P1
P2P2
ELECTRICAL DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE ELECTRICAL PERMIT NOT
REQUIRED.
1
DISCONNECT ALL GARAGE ELECTRICAL
DAMAGED BY TREE. EVALUATTE CIRCUITS
TO GARAGE FOR REPAIR.
E1E1
E2E2
E1E1
E2E2
GENERAL NOTES
NOTE QTY DESCRIPTION
1 DUMPSTER AND PORTALET LOCATIONS TO
BE DETERMINED ON SITE W/ HOMEOWNERS
1
(TEMPLATE) HOMEOWNERS TO MOVE ALL
NECESSARY FURNITURE FROM AREAS OF
REMODEL PRIOR TO START OF WORK
1
(TEMPLATE) HOMEOWNERS TO REMOVE
ALL WINDOW COVERINGS PRIOR TO START
OF WORK
1
(TEMPLATE) HOMEOWNERS TO CLEAR OUT
SPACE IN GARAGE FOR STORAGE OF
BUILDING MATERIALS PRIOR TO START OF
WORK.
GN1GN1
GN2GN2
GN3GN3
GN4GN4
GN1GN1
GN2GN2
GN3GN3
GN4GN4
HVAC DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE HVAC PERMIT NOT REQUIRED.
1 EXISITNG HOOD DUCT TO REMAIN BE
REPAIRS DURING MECHANICAL ROUGH-INS
H1H1
H2H2
H1H1
H2H2 MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision:
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917GENERAL SITE PREP & DEMO NOTES
Install plastic to seal off areas being remodeled from rest of home as necessary.
Install floor covering for construction path from door designated as the construction
entrance to locations of remodeling as necessary.
Install additional floor covering or wall protection as needed over areas close to the areas
of construction activity.
Install dust control measures on HVAC cold air returns located within the locations of
remodeling.
Custom Living can provide a HEPA Air Scrubber to aid in airborne dust control from the
start of demolition up to priming of new drywall depending on site conditions. Homeowner
understands that this will help to reduce airborne dust; however, it will not mitigate it in its
entirety.
Demolition Contractor(s) are responsible for all labor, for the scope of work specified in
the drawings provided by Custom Living.
Homeowner understands that Custom Living has only provided a labor and material
allowance for the scope of demolition denoted on the drawings. Any additional scope
added or uncovered during demolition result in filing a Change Order during
construction.
Homeowners understand that demolition work will generate dust and noise throughout
the house. Custom Living will provide site protection measures to reduce where possible,
but Homeowners should not expect 100% containment.
EXISTING / DEMO PLAN
SCALE: 1/4" = 1'A1
SB3021B15LCB36R3DB24SB36DWB27B27 B36B36B36SB3021B15LCB36R3DB24SB36DWB27B27 B36B36B36HB
D02
D01
W02 W04
W01D03W01
W03
DN
FLOOR JOIST DIRECTIONFLOOR JOIST DIRECTIONFLOOR JOIST DIRECTIONH / ACH / AC
H / AC
CEILING
WP
CO/SD
SD
SD
SD
SD
E1
A3
E1
A3
Elevation 1
E2
A3
E2
A3
Elevation 221'-4"22'10'-0 1/2"25'-0 1/2"18'-4 1/2"24'-1 1/8"
CL
10'-1"CL1'-11"CL10'-8"10'-8"
CL
9'-5"
CL5'-3 1/4"F1F1
BM1BM1
I3I3
I2I2
D2D2
D3D3
F2F2
DINING ROOM
8' - 1-1/2" C.H. AFF
HARDWOOD
NOOK
8' - 1-1/2" C.H. AFF
HARDWOOD
KITCHEN
8'-1 1/2" C.H. AFF
HARDWOOD
LAUNDRY
8'-1 1/2" C.H. AFF
BATH
8'-1 1/2" C.H. AFF
ENTRY
VAULTED C.H. AFF
TILE
PRIMARY BEDROOM
8' - 1-1/2" C.H. AFF
CARPET
BEDROOM 2
8' - 1-1/2" C.H. AFF
CARPET
BEDROOM 3
8' - 1-1/2" C.H. AFF
CARPET
HALLWAY
8' - 1-1/2" C.H. AFF
CARPET
BATHROOM
8' - 1-1/2" C.H. AFF
DRESSING ROOM
8' - 1-1/2" C.H. AFF
CARPET
CLOSET
8' - 1-1/2" C.H. AFF
CARPET
BATHROOM
8' - 1-1/2" C.H. AFF
CARPET
GREAT ROOM
VAULTED C.H. AFF
HARDWOOD
LINEN
DECK
GARAGE
9' - 1-1/2" C.H. AFF
CONCRETE COURTYARD
PULL DOWN STAIR
F3F3
F4F4
F5F5
F2F2
F6F6
ST1ST1
ST1ST1
ST2ST2
ST3ST3
EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
EXTERIOR DOOR SCHEDULE - 1ST FLOOR
NUMBER FLOOR DESCRIPTION QTY R/O SUPPLIER
D01 1 HINGED 1 38"X86 1/4"
D02 1 GARAGE-SLAB 1 194"X87"
D03 1 DOUBLE HINGED 1 55"X82 1/4"
WINDOW SCHEDULE - 1ST FLOOR
NUMBER FLOOR DESCRIPTION QTY R/O TOP EGRESS TEMPERED SUPPLIER
W01 1 DOUBLE CASEMENT 2 30"X59"87"
W02 1 DOUBLE CASEMENT 1 40"X59"94 1/8"
W03 1 FIXED GLASS 1 57"X20"80"
W04 1 DOUBLE CASEMENT 1 40"X59"80"
FRAMING PLAN NOTES
NOTE QTY DESCRIPTION
1
FRAME NEW EXTERIOR GARAGE WALLS AS
SHOWN ON TOP OF EXISTING GARAGE
FOUNDATION.
2
FRAME NEW WINDOW ROUGH OPENING
PER WINDOW SPECIFICATIONS. INSTALL
NEW WINDOW UNITS IN NEW OPENINGS.
1
FRAME NEW GARAGE DOOR ROUGH
OPENING PER GARAGE DOOR
SPECIFICATIONS AND STRUCTURAL
ENGINEER REQUIREMENTS. GARAGE DOOR
COMPANY TO INSTALL GARAGE DOOR.
1
FRAME NEW DOOR ROUGH OPENING PER
DOOR SPECIFICATIONS AND STRUCTURAL
ENGINEER REQUIREMENTS. INSTALL NEW
EXTERIOR DOOR IN NEW ROUGH OPENING.
1 FRAME NEW HIP ROOF SYSTEM SAME AS
ORIGINAL DESIGN.
1
FRAME NEW ATTIC ACCESS OPENING IN
CEILING RAFTERS. PREP FOR ATTIC PULL
DOWN STAIRS SIMILAR TO EXISTING
ORIGINAL ACCESS.
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
INSULATION PLAN NOTES
NOTE QTY DESCRIPTION
1
FOAM AND FIRECAULK ALL MECHANICAL
OPENINGS PER MUNICIPAL CODE
REQUIREMENTS
1
INSTALL NEW BLOWN FIBERGLASS
INSULATION IN ENTIRE ATTIC ABOVE
GARAGE, KITCHEN, AND DINING ROOM
AREAS.
1
INSTALL NEW R-15 FIBERGLASS BATT
INSULATION IN ALL NEW EXTERIOR WALLS
AND WALL BETWEEN GARAGE AND HOUSE.
I1I1
I2I2
I3I3
I1I1
I2I2
I3I3
DRYWALL PLAN NOTES
NOTE QTY DESCRIPTION
1
EXISTING INTERIOR DRYWALL FINISH
NOTES; (WALLS) SMOOTH-LEVEL 4,
(CEILINGS) SMOOTH-LEVEL 4
1
INSTALL NEW DRYWALL ON ALL NEWLY
FRAMED WALLS. PATCH ALL AREAS
NECESSARY FROM DEMO AND MECHANICAL
ROUGH INS. MATCH EXISTING DRYWALL
FINISH. FINAL SCOPE TO BE DETERMINED
FOLLOWING MECHANICAL ROUGH INS.
1
INSTALL NEW DRYWALL ON ALL CEILINGS
NECESSARY FROM DEMO AND MECHANICAL
ROUGH INS. MATCH EXISTING CEILING
FINISH IN HOME. GARAGE CEILING
DRYWALL TO BE KNOCK DOWN TEXTURE.
FINAL SCOPE TO BE DETERMINED
FOLLOWING MECHANICAL ROUGH INS.
D1D1
D2D2
D3D3
D1D1
D2D2
D3D3
EXTERIOR SIDING & TRIM NOTES
NOTE QTY DESCRIPTION
2
MATCH WINDOW TRIM TO OTHER EXISTING
WINDOWS.
TRIM IS 1X8 ROUGH CEDAR APPLIED OVER
BRICK. MATCH ANGLE DETAIL FOR
WINDOW LINTEL.
1 GARAGE DOOR TRIM TO BE ROUGH SAWN
CEDAR
1
ALL SOFFIT AND GUTTER BOARD TO BE
ROUGH SAWN CEDAR TO MATCH
EXISTING.
ST1ST1
ST2ST2
ST3ST3
ST1ST1
ST2ST2
ST3ST3
BRICK & MASONRY PLAN NOTES
NOTE QTY DESCRIPTION
1
NEW BRICK VENEER TO BE INSTALLED ON
NEWLY FRAMED WALLS. FINAL SCOPE TO
BE DETERMINED FOLLOWING DEMO.
MATCH EXISTING BRICK DETAILS WITH
SOLDIER COURSE ACROSS THE TOP OF
WALL AND QUOINS ON FRONT CORNERS.
BM1BM1BM1BM1
NMELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision:
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917GENERAL PROPOSED PLAN NOTES
Framing contractors are responsible for all labor, for the scope of work specified on the
drawings provided by Custom Living.
Owner understands that Custom Living has only provided a labor and material allowance
for the scope of Rough Carpentry work specified on the drawings. Any additional work
added or uncovered during this scope will be filed as a Change Order during
construction
Owner understands that the drywall allowance is based on an estimated board count and
square footage take-off. A final walk through with a drywall contractor after framing and
mechanical rough-ins will be necessary to finalize drywall installation and finish budgets.
Final drywall touch-ups will follow countertop installation.
PROPOSED FLOOR PLAN
SCALE: 1/4" = 1'A2
SOUTH ELEVATIONE3E3
WEST ELEVATIONE4E4
FRONT ELEVATIONE1E1
SIDE ELEVATIONE2E2 MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision:
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917EXTERIOR ELEVATIONS & DETAILS
SCALE: 1/2" = 1'
***VERIFY SCALE ACCURACY
A3
TTTTTTT
VENTED SOFFIT
WOOD FRIEZE BOARD
MASONRY TIE
BRICK VENEER
ASPHAULT SHINGLE ROOF
ROOFING MEMBRANE
FLASHING
FASCIA
2x8 RAFTERS @ 16" O.C.
2x8 CEILING JOISTS @ 16" O.C.
GUTTER
EXISTING CONCRETE SLAB
EXISTING 4" COMPACTED
GRAVEL BASE
2X4 TREATED SILL PLATE
1/2" ANCHOR BOLT @ 6' O.C.
SILL SEAL
EXISTING 8" CMU
FOUNDATION WALL
EXISTING GARAGE FOOTING
4" BRICK VENEER
WEEP HOLES
1" AIR GAP
2x4 DOUBLE TOP PLATE
2X4 WALL STUDS @ 16" O.C.
3/4" OSB SHEATHING
BRICK LEDGE
GRADE
9'-1 1/2" CEILING HEIGHT
1'-4"9'-1 1/2"HEADER-
DOUBLE 2X8 (UNLESS
NOTED OTHERWISE)
DOUBLE
TOP PLATE
KING STUD
CRIPPLE STUD
TREATED
BOTTOM PLATE
O.C.
4" CONCRETE
SLAB
EXISTING 2X8 CEILING
JOISTS @ 16" O.C.MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision:
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917WALL SECTIONS & STRUCTURAL FRAMING DETAILS A4
WALL SECTION
SCALE: 2" = 1'TYPICAL WALL FRAMING
SCALE: 1/2" = 1'
REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER SUPPLY
COOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE SWITCH
DIMMER SWITCH
3-WAY SWITCH
4-WAY SWITCH
GD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY SWITCH
SURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON MONOXIDE
MOTION SENSOR
CEILING SPEAKER
GAS SHUT-OFF KEY
MAIN WATER SHUT-OFF
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
COLD AIR RETURN
FLOOR FLOOR SUPPLY REGISTER
CEILING CEILING SUPPLY REGISTER
WALL WALL SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
T THERMOSTAT
DRYER BOX
ELECTRICAL KEY
PLUMBING KEY
HVAC KEY
HB
DNH / ACH / AC
H / AC
CEILING
WP
CO/SD
SD
SD
SD
SD
LV1LV1
H1H1
E1E1
E7E7
E6E6
E5E5
E4E4
DINING ROOM
8' - 1-1/2" C.H. AFF
HARDWOOD
NOOK
8' - 1-1/2" C.H. AFF
HARDWOOD
KITCHEN
8'-1 1/2" C.H. AFF
HARDWOOD
LAUNDRY
8'-1 1/2" C.H. AFF
BATH
8'-1 1/2" C.H. AFF
ENTRY
VAULTED C.H. AFF
TILE
PRIMARY BEDROOM
8' - 1-1/2" C.H. AFF
CARPET
BEDROOM 2
8' - 1-1/2" C.H. AFF
CARPET
BEDROOM 3
8' - 1-1/2" C.H. AFF
CARPET
HALLWAY
8' - 1-1/2" C.H. AFF
CARPET
BATHROOM
8' - 1-1/2" C.H. AFF
DRESSING ROOM
8' - 1-1/2" C.H. AFF
CARPET
CLOSET
8' - 1-1/2" C.H. AFF
CARPET
BATHROOM
8' - 1-1/2" C.H. AFF
CARPET
GREAT ROOM
VAULTED C.H. AFF
HARDWOOD
LINEN
DECK
GARAGE
9' - 1-1/2" C.H. AFF
CONCRETE COURTYARD
E7E7
E6E6
E8E8
E10E10
E9E9
NPROPOSED ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1
VERIFY EXISTING SMOKE AND CO
DETECTORS MEET CURRENT CODE
REQUIREMENTS. HOMEOWNERS
UNDERSTAND THAT IF EXISTING FIXTURES
NEED TO BE BROUGHT UP TO CODE, THERE
WILL BE AN ADDITIONAL COST. THIS WILL
BE DETERMINED ON A FIELD WALK.
1 VERIFY ALL INSTALLED GFCI OUTLETS
MEET CURRENT CODE REQUIREMENTS.
1
VERIFY EXISTING PANEL SIZING WILL
SUPPORT PROPOSED ELECTRICAL.
HOMEOWNERS UNDERSTAND IF THE PANEL
NEEDS TO BE UPDATED, THERE WILL BE AN
ADDITIONAL COST.
1 REFEED 220 V CIRCUIT FOR DRYER.
1
PROVIDE ROUGH IN AND FINISH FOR (1)
SWITCH IN EXISTING LOCATION AS SHOWN
CONNECTED TO (2) NEW KEYLESS BULB
FIXTURES AS SHOWN. DEVICE STYLE AND
COLOR SHOWN. ALL SWITCHES TO BE
STANDARD HEIGHT U.N.O. ALL SPECIALTY
DEVICES AS SHOWN ON PRINTS.
2
PROVIDE ROUGH IN AND FINISH FOR (6)
INTERIOR WALL OUTLETS IN NEW
LOCATIONS AS SHOWN. PROVIDE ROUGH IN
AND FINISH FOR (1) INTERIOR CEILING
OUTLETS IN NEW LOCATIONS AS SHOWN.
PROVIDE ROUGH IN AND FINISH FOR (1)
EXTERIOR WALL OUTLETS IN NEW
LOCATIONS AS SHOWN.
DEVICE STYLE AND COLOR SHOWN. ALL
OUTLETS TO BE STANDARD HEIGHT U.N.O.
ALL DEVICES TO BE STANDARD OUTLETS
U.N.O. (CALL OUT ANY SPECIALTY OUTLET
LOCATIONS OR DEVICES IN SEPARATE
NOTES)
2
PROVIDE FINISH FOR (5) EXTERIOR COACH
LIGHTS IN EXISTING LOCATIONS AS SHOWN.
FIXTURES TO BE PROVIDED BY
HOMEOWNERS. HOMEOWNERS
UNDERSTAND THE TYPE OF FIXTURE
SELECTED MAY HAVE AN EFFECT ON
INSTALLATION COST.
1
PROVIDE ROUGH IN AND FINISH FOR (1)
NEW EXTERIOR MOTION FLOOD LIGHT AT
CORNER OF GARAGE WALL. WIRED TO BE
HOT.
1 REFEED DEDICATED CIRCUIT TO
REFRIGERATOR.
1 VERIFY ELECTRICAL CIRCUITS IN BACK
HALLWAY ARE ACTIVE AND WORKING.
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
PROPOSED LOW VOLTAGE PLAN NOTES
NOTE QTY DESCRIPTION
1
ADJUST WIRING OF DOORBELL
DEPENDING ON NEW FRONT DOOR
INSTALLATION.
LV1LV1LV1LV1
PROPOSED HVAC PLAN NOTES
NOTE QTY DESCRIPTION
1 REWORK HOOD EXHAUST PIPING TO MEET
CODE.H1H1H1H1
PROPOSED PLUMBING PLAN NOTES
NOTE QTY DESCRIPTION
1 NO CURRENT PLUMBING SCOPE.P1P1P1P1 MELTZER RESIDENCEGarage Rebuild12410 Windsor DrCarmel, IN 46033Date:Revision:
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/19/23
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: PETER MEEHANE: peter@customlivingusa.comC: 847.702.2917PROPOSED M.E.P. PLAN
SCALE: 1/4" = 1'M1
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering calculation
necessary for correct sizing of new equipment and
ductwork being supplied, fabricated and installed for the
project.
HVAC ductwork installed in unconditioned areas to be
insulated and sealed per Building Code Standards.
HVAC contractor to start, test, and balance any new
equipment and ductwork to assure proper operation of
new systems.
Final plumbing materials selected may have an affect on
the final Plumbing Material and Installation Budgets.
Owners understand that if additional plumbing, electrical or
ductwork is found in walls being deleted that is not
included on the plans there will be a Change Order during
construction to relocate as necessary.
Owners understand that during mechanical rough-ins there
will be times when the water service will be shut off to
areas in the home.
Plumbing and Lighting fixtures supplied by Owner will not
be warranted by Custom Living
Plumbing and Lighting fixtures supplied by Owner must be
selected and on-site prior to start of mechanical rough-ins.