HomeMy WebLinkAboutRepublic_Hotel-ARCH-V21 - Sheet - A-204 - EXTERIOR ELEVATIONSFOURTH LEVEL -SOUTH
129'-4"
FIFTH LEVEL -SOUTH
139'-0"
SIXTH LEVEL -SOUTH
148'-8"
SEVENTH LEVEL -
SOUTH
158'-4"
ROOF LEVEL -SOUTH
168'-0"
12345678
MP-2
METAL PANEL CLADDING SYSTEM
MP-1
METAL PANEL CLADDING SYSTEM
FULL HEIGHT MECHANICAL LOUVER
ALUM. STOREFRONT WINDOW SYSTEM
CURTAIN WALL GLAZING SYSTEM
MP-01 GL-01
GL-01
GL-01 2
FOURTH LEVEL -SOUTH
129'-4"
FIFTH LEVEL -SOUTH
139'-0"
SIXTH LEVEL -SOUTH
148'-8"
SEVENTH LEVEL -
SOUTH
158'-4"
ROOF LEVEL -SOUTH
168'-0"
1 2 3 4 5 6 7 8
MP-2
METAL PANEL CLADDING SYSTEM
MP-1
METAL PANEL CLADDING SYSTEM
FULL HEIGHT
MECHANICAL LOUVER
ALUM. STOREFRONT
WINDOW SYSTEM
CURTAIN WALL
GLAZING SYSTEM
GL-02
GL-01 GL-01
GL-02
GL-01
GL-01
2
2
2
FIRST LEVEL
100'-0"
THIRD LEVEL
119'-8"
FOURTH LEVEL -SOUTH
129'-4"
FIFTH LEVEL -SOUTH
139'-0"
SIXTH LEVEL -SOUTH
148'-8"
SEVENTH LEVEL -
SOUTH
158'-4"
ROOF LEVEL -SOUTH
168'-0"
ABCDEFGA.2B.1B.9
A.1
HOTEL DROP-OFF CANOPY
CONNECTOR BRIDGE
CURTAIN WALL GLAZING SYSTEM
CURTAIN WALL GLAZING SYSTEM
METAL HANGER-ROD
CANOPY SUPPORT
GL-02
GL-01
GL-01
MP-01
GL-01 GL-01 GL-01
GL-02
GL-01
2
2
2
2
2
GL-01
2
SHEET TITLE
SHEET NUMBER
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Plumbing Design/Builder
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
PROJECT NO.
SHEET ISSUE
NOT FOR CONSTRUCTION
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
9/23/2021 5:38:15 PMA-204
EXTERIOR
ELEVATIONS
21040.000
Republic Airways
Hotel
12197 N Meridian St.
Carmel, IN 46032
KEYNOTES (SPEC BASED)
3/32" = 1'-0"A-204
A3 SOUTH WING - NORTH ELEVATION
3/32" = 1'-0"A-204
C3 SOUTH WING - SOUTH ELEVATION
3/32" = 1'-0"A-204
E3 WEST ELEVATION
1 BID PACKAGE #1 08/30/21
2 BE#1 ADD#1 09/14/21
09/14/21